There is a constant need for the reduction of operational and
maintenance costs of large sized synchronous generators. The most efficient
way of reducing these costs would be continuous monitoring of the condition of these generators. This allows for early detection of the degeneration of the generators health, facilitating a proactive response, minimizing downtime, and maximizing productivity. There are many techniques and tools available, which are used to monitor the condition of these machines and prolonging their life span. Stator winding faults of synchronous generator are considered serious problems because of the damage associated with high currents and high cost of maintenance. A high speed bias differential relay is normally used to detect three phase, phase to phase and double phase to ground faults. Detection of single line to ground faults depends on the generator grounding type which can be classified into low and high impedance grounding. In case of low impedance grounding, a differential relay can detect and provide protection of only about, 95% of the windings. However, for high impedance grounding, ground faults are not normally detectable by the differential relay because the fault current is usually less than the sensitivity of the relay. In such case, an over-voltage relay connected across the grounding resistor has been used to sense the zero sequence voltage. This relay should be set to avoid tripping of normal unbalance which yields reduced sensitivity. 50 In this work, Computational Intelligence based approaches for identifying Stator Earth Fault and Inter-Turn fault of Synchronous Generator are proposed. The detector uniquely responds to the winding inter-turn fault and Stator Earth Fault with remarkable high sensitivity. Discrimination of different percentage of winding affected by these faults is provided via ANN or GA-BPN or ANFIS which are given with eight dimensional input vector. This input vector is obtained from features extracted from DWT of faulty current leaving the generator phase winding for the case of Inter-Turn fault. For stator earth fault protection subharmonic injection technique is followed. So the neutral current of the generator is taken for structuring input vector. Training data for ANN, GA-BPN and ANFIS are generated via a simulation of generator with these faults using MATLAB Simulink. The proposed algorithm using ANFIS is giving satisfied performance than ANN and GABPN with selected statistical data of decomposed levels of faulty current
Digital Filmmaking: The Ultimate Guide to Web Video Production for Beginners and Non-Professionals, Learn Useful Tips and Advice on How You Can Create, Film and Edit Your Videos