V200R003
BOM 31250477
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support
and service. If you purchase the products from the sales agent of Huawei Technologies Co.,
Ltd., please contact our sales agent. If you purchase the products from Huawei
Technologies Co., Ltd. directly, Please feel free to contact our local office, customer care
center or company headquarters.
Website: http://www.huawei.com
All other trademarks and trade names mentioned in this document are the
property of their respective holders.
Notice
The information in this document is subject to change without notice. Every effort
has been made in the preparation of this document to ensure accuracy of the
contents, but all statements, information, and recommendations in this document
do not constitute the warranty of any kind, express or implied.
Release Notes
Related Manuals
The related manuals and usages of the Quidway NetEngine20E Series Routers are
listed in the following table.
Manual Content
It introduces the installation of NE20E Series
Quidway NetEngine20E Routers, including the board installation, the cable
Series Routers Installation installation, the NE20E start, the hardware
Manual maintenance, the label specification and the
grounding specification.
It introduces the NE20E Series Routers hardware,
Quidway NetEngine20E
including the equipment introduction, the power
Series Routers Hardware
module, the heat dissipation system, the board, the
Description
equipment cable and some appendixes.
Operation Manual is organized into eight volumes
and every volume has many chapters, including the
overview of the volume and the configuration of the
attributes. The appendix introduces the
Quidway NetEngine20/20E abbreviations in the volume.
Series Routers Operation
Manual Every attribute configuration contains introduction,
configuration tasks, maintenance, configuration
examples and troubleshooting.
It is organized into eight volumes as given below:
It describes the configuration of the system
management and the reliability, including the
establishment of the configuration environment, the
System Volume basic configuration, the user login, the file
management, the system maintenance, NTP,
SNMP, backup center, VRRP, reliability, GR and
abbreviations.
Organization
Chapter 2 Power Supply describes the DC and AC power module according to the
outline, the front panel, the function and the technical specifications of the power
module.
Chapter 4 Board introduces the classification of the board, the slot allocation, the
interface types and the allocation on the board. And it also describes every board
according to the function, the front panel, the interface description, the attributes and
technical specifications.
Appendixes A to C contain the following three appendixes: the Indicator List, the
Board List, and the acronym and Abbreviation. In the daily maintenance, you can
quickly look up the related information about the device by the appendixes.
Index collates important keywords used in this manual to help the reader to access
the required information quickly.
Intended Audience
Conventions
I. General conventions
Convention Description
Arial Normal paragraphs are in Arial.
Eye-catching symbols are also used in the manual to highlight the points worthy of
special attention during the operation. They are defined as follows:
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
ii
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
iii
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
iv
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview
Chapter 1 Overview
The chapter introduces the structure, the system configuration and the physical
specifications of Quidway NetEngine20E Series Routers.
1.1 Introduction
At present, NE20E only has NE20E-8 with adopts the modularized structure and
provides the High-speed Interface Card (HIC) and the Flexible Interface Card (FIC).
The hardware structure of the NE20E provides the following maintainable attributes:
z Supports hot swap.
z Adopts the backplane in the middle. The boards are inserted in the backplane
horizontally. The structure is convenient for the configuration and maintenance.
z The fan is located on the left of the router backplane. It uses multiple fans to
carry out the ventilation for the requirements of heat dissipation.
Besides, NE20E has effective monitoring system. It manages and maintains the
whole system by the main control module on the Routing Process Unit (RPU). RPU
can manage, monitor and maintain the board, the fan module and the power
module.
NE20E abide by the Electro Magnetic Compatibility (EMC) and the Underwriter
Laboratories Inc. (UL). The whole system reaches the module-class shield level.
Every handle is made of steel sheet to isolate the electromagnetic wave of boards.
1.2 Structure
The NE20E-8 adopts the backplane in the middle and the integrated chassis with
the board inserted horizontally. The chassis is 6 U (1 U = 44.45 mm) high and can
be mounted in a 19-inch standard cabinet or on the workbench.
1-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview
I. Front Panel
1 2
AC
LIN
AC
LIN
AC
LIN
AL
R
N
FA
PW
PW 1
1
R 2
TX
TX
R
T
T
PU
PU
PU
K
ES
1
N
M
X
R
R
10
1
2
ET
SYS RUN PRN LINK LINK
NPU MST ALM ACT ACT
CompactFlash CARD RPU
10/100BASE TX AUX CONSOLE 10/100/1000MEthernet 0 10/100/1000MEthernet 1
AC
LIN
AC
LIN
AC
LIN
PW
PW 1
1
AL
R
N
FA
R 2
TX
TX
R
K
K
PU
PU
PU
ES
1
N
M
X
R
R
9
1
2
ET
SYS RUN PRN LINK LINK
NPU MST ALM ACT ACT
10/100BASE TX AUX CONSOLE 10/100/1000MEthernet 0 10/100/1000MEthernet 1 CompactFlash CARD RPU
LINK 7 8
LINK LINK
ACT ACT
2FE 2FE 4SAE 4SAE
0 10Base-T/100Base-TX 1 0 1 ACT 2 3
8*EI-120ohm 8*EI-120ohm 5 6
LINK LINK LINK LINK
ACT ACT ACT ACT
8EIA 0 1 2 3 4 5 6 7 8EIA 8EIA 8EIA
R
TX
0
3 4
X
LINK LINK LINK
ACT ACT ACT
2FE 10Base-T/100Base-TX 2FE RT-HIC-1POS
0 1
1 3 5 7
LIN
LIN
1 2
R
R
TX
TX
0
1
X
X
K
RT-HIC-2POS RT-HIC-8FE
AC
AC
0 2 4 6
T
11 10 9 8 7 6 5 4 3
2. RPU 1-slot 9 3.ESD-preventive wrist strap
1. RPU 2-slot 10
jack
4. FIC/HIC interface 5. FIC/HIC interface module 6. FIC interface module slot 6
module slot 2 slot 4
7. FIC interface module 8. FIC interface module slot 9. FIC interface module slot 5
slot 8 7
10. FIC/HIC interface 11. FIC/HIC interface
module slot 3 module slot 1
Figure 1-1 Front panel of the NE20E-8 router
1 2 3 4 5 6 7 8
R
AL
U
M
N
FAN NPU
R
AL
U
M
N
D o nt u s e th is h a n d le
to lif t s u b ra c k
CA U T IO N
NPU
DO NO T
TO UC H T HE
FAN L EAVE S
BEF OR E T HE Y
S L O W DO WN
A
R
AL
C
UN
OK
100-240V
A
R
AL
C
UN
OK
100-240V
11 10 9
1. Fan module 2.NPU 1 3. NPU 2
4.Filler panel 5.Filler panel 6. Power module 1 (PWR1)
7.Power module 2 9. AD Power interface
8. Grounding screw
(PWR2)
11. ESD-preventive wrist
10. Power switch
strap jack
Figure 1-2 Rear panel of the NE20E-8 router
1-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview
Power module It is located in the two slots at the backplane Refer to Chapter
bottom. Every cabinet must be configured 2 Power
with two power modules and one 1+1 Supply.
backup. The NE20E provides the AC power
module and the DC power module.
Cable It contains the power cable, fiber and the Refer to Chapter
external whole-set cable. 6 Cable.
Item NE20E-8
Number of slots 12
Maximum number of
8
interface boards
Fan backup Redundancy backup 2 x 4
1-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview
Item NE20E-8
SDRAM 512 M (default), can be extended to 2G
NVRAM 512 KB
Flash 64 MB
Packet transmission rate 6 Mpps
Note:
z Synchronous Dynamic Random Access Memory (SDRAM) specifies the memory
that stores the communication data between the system and CPU.
z As the storage medium of the significant files, Non-Volatile Random Access
Memory (NVRAM) stores the configuration files and the record of the system
running state.
z Flash memory functions as the major file storage medium to store the operating
system and the application program files.
z Boot ROM stores the boot program file when the system is started.
Item NE20E-8
Cabinet Structure Integrated cabinet, 6 U
Height
263.9 mm
(H)
Width
Dimension 436.2 mm
(W)
Depth
480.0 mm
(D)
1-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview
Item NE20E-8
Rated voltage range: 100 V AC to 240 V AC; 50/60Hz
AC
Input Maximum voltage range: 90 V AC to 264 V AC; 50/60Hz
voltage Rated voltage range: 48 V DC
DC
Maximum voltage range: 72 V DC to 36 V DC
Maximum configuration
32 Kg
weight
Maximum power
320 W
consumption
Module RPU 30 W
consumpti
on NPU 58 W
Storage temperature 40 to 70
Note:
z The measurement point of the temperature and humidity is 1.5 m over the floor
and 0.4 m in front of the cabinet. There should be no protection board at the front
or back of the cabinet.
z Short-term operation means that the continuous working time does not exceed
48 hours and the accumulated time per year does not exceed 15 days.
1-5
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module
The chapter introduces the appearance and the front panel of the power module, the
function and the technical parameters of the NE20E-8.
2.1.1 Appearance
The NE20E-8 provides two types of the power module, that is, the AC input and the
DC input. The appearance of the AC power module is shown in Figure 2-1. And the
appearance of the DC power module is shown in Figure 2-2.
AC
AL
R
U
M
N
O
K
The appearance of the front panel of the AC power module is shown in Figure 2-3.
The appearance of the front panel of the DC power module is shown in Figure 2-4.
2-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module
100-240V
100-240V
-48~-60V
-48~-60V
Table 2-1 Relationship of the terminal block connection of the power input cable
Identifier of
Input cable Input cable
the terminal Input cable interface
name color
block
Protection
PGND grounding Kelly Need not to be connected.
cable
Note:
z RTN: Return
z NEG: Negative
z PGND: Protection Ground
As shown in Table 2-2 and Table 2-3, the running state of the power module is
available from the indicators of the RPU front panel.
2-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module
The running state of the power module is available from the indicators of the RPU
front panel. For details, refer to RPU of Chapter 4 Board.
2.2 Functions
The NE20E-8 provide two types of the power modules, that is, the AC input and the
DC input. The power modules are inserted in the backplane from the back.
2-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module
Usually, two power modules work in the redundancy backup mode. The AC and the
DC power modules are the PSR550-A and the PSR550-D power respectively. The
power line adopts the -48V feeder cable of D 3PIN.
Note:
If you want to install an NE20E in the communication equipment room, you need to
make sure that the power distribution cabinet can provide the lightning protection box
or arrester against the current of 20 KA and above.
Weight 1.5 kg
Input rated 100 V AC to 240 V AC
voltage AC
50/60 Hz
Input
voltage DC -48 V DC to -60 V DC
Maximum 85 V AC to 264 V AC
input AC
current 50/60 Hz
Input
surge DC -36V DC to -72V DC
current
2-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module
2-5
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 3 Heat Dissipation System
This chapter introduces the fan function, the fan appearance, the front panel and the
technical specifications of the NE20E-8.
3.1.1 Appearance
The fan of the NE20E-8 is located on the left of the cabin backplane. It ventilates the
panel and dissipates the heat. The fan supports the hot swap.
The fan module contains the fan frame and the fan components. The appearance of
the fan module is shown in Figure 3-1.
3-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 3 Heat Dissipation System
FAN
DO NOT
TOUCH TH E
FAN LE AVE S
BEFORE THEY
SLOW DOWN
The indicators for warning the state of the fan module are located on the RPU front
panel. The indicators of the fan module on the RPU are described in Table 3-1.
3.2 Functions
The rev of the fan module is controlled by the RPU. The fans working normally can
keep NE20E-8 working in the normal temperature. Its functions contain:
z The fan module can modify the rev automatically. It configures two parameters,
the low-temperature threshold and the high-temperature threshold. The
low-temperature threshold and the high-temperature threshold correspond with
the revs of 100% and 50% respectively. For the operation requirements on the
temperature, see Chapter 1 Product Overview.
3-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 3 Heat Dissipation System
z As the failure of a fan does not affect the operation of other fans, the system can
still be able to operate in the normal temperature.
z The system sends out rotation stop alarm signals in case any fan fails.
The heat dissipation system of the NE20E-8 dissipates the heat by ventilating the
NE20E-8. From the top, you can see the air flow enters the NE20E-8 from left and
comes out from right. The air flow inside the NE20E-8 is shown in Figure 3-3.
Item Specifications
Dimensions 259.45 mm (H) x 47.70 mm (W) x 462.65 mm (D)
Power
38.4 W
consumption
Maximum
blast 75 Pa
pressure
Maximum 3
921.6 m /h
blast volume
Maximum
60 dB
noise
Maximum
3800 RPM
rev
Operating
voltage 7.0 V to 13.8 V DC
range
Operating
12 V DC
voltage
3-3
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
ii
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Chapter 4 Board
The chapter introduces the board classification, the board appearance and the
interface type and describes the technical details of the every board, including:
z Functions
z Board
z Interface attributes
4.1 Introduction
From the introduction in the chapter, you can know the board classification, the
board appearance, the interface type and the interface distribution on the board.
I. Board Classification
4-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Note:
The NE20E router with the host software version of VRP5.30-23134002 or later
supports application of the HSSI interface.
RPU 10
RPU 9
FIC FIC 7 8
FIC FIC 5 6
FIC HIC/FIC 3 4
HIC/FIC HIC/FIC 1 2
The RPU can be only inserted into the slots 9 and 10 on the top of the front panel of
the chassis. The NPU can be only inserted into the two slots on the top of the rear
panel of the chassis
4-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
HIC can only be inserted into the slots 1, 2 or 4. The FIC can be inserted into the
slots 1 to 8.
Caution:
Wear an ESD-preventive wrist strap and keep it well-grounded whenever you touch
the board to prevent the ESD from damaging the board.
Warning:
Do not let your eyes near or stare at the optical interface or the fiber interface. The
laser bean is harmful to your eyes.
The appearances of RPU, NPU and HIC/FIC are respectively shown in Figure 4-2,
Figure 4-3 and Figure 4-4. Take the 8E1A as the example.
1 2 3
PW PW
R1 R
2
13 12 11 10 9 8 7 7 6 5 4
4-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
6 5 4 3 2
1 2
7 6 5 4 3
Name Dimensions
RPU 399.15 mm (W) x 236 mm (D) x 35.06 mm (H)
NPU 372.45 mm (W) x 238 mm (D) x 35.06 mm (H)
All interfaces are integrated on the board and imported from the board. The interface
distributions on the board are shown in Table 4-2.
4-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Single-mode long
1000Base haul optical RT-HIC-1GE
FX interface
Ethernet LC RT-HIC-2GE
optical Single-mode ultra
interface long haul optical RPU
interface
Multi-mode
Opitcal
optical interface
interface
Single-mode
1ATM-OC3SM
optical interface
155M
Single-mode long
ATM
haul optical SC 1ATM-OC3SML
optical
interface
interface
Multi-mode
1ATM-OC3MM
optical interface
Single-mode
short haul optical
interface
Multi-mode
optical interface
4-5
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
4.2 RPU
This section introduces the functions of Routing Process Unit (RPU), the board, the
interface and the technical specifications.
RPU is located in either of two slots on the bottom of the case-shape cabinet. The
RPU is inserted in the front panel and corresponds with the NPU in the system.
4.2.1 Functions
RPU is the system main control board of the NE20E. It consists of PowerPC
processor, the system controller bridge, the storage and other attached devices.
RPU monitors the system ports, manages the equipment and processes various
software protocols. It is the significant component of the NE20E.
4-6
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
The panel appearance is shown in Figure 4-5. The components are described in
Table 4-3.
LI
AC
N
K
T
LI
AC
N
1
K
T
TX
R
1
X
LINK
10/100BASE TX AUX CONSOLE ACT
10/100/1000M Ethernet 1
AC
LIN
AC
LIN
AC
LIN
0
1
AL
FA
T
K
K
PU
PU
PU
PU
PU
TX
TX
R
ES
M
1
X
X
1
ET
N
N 1
R 2
R
AL
FA
PU
PU
PU
PU
ES
PU
M
N
2
ET
4-7
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
4-8
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
4.2.3 Interfaces
The interfaces on the RPU and their usage are shown in Table 4-4.
4-9
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Item Description
It indicates the local debugging serial port.
It can be connected with the terminal end of characters or
the serial ports of the local PC. And the terminal emulation
program can be operated on the PC.
Console port
It can be used as the CLI and also be use for the board or
system debugging, testing, the serial port printing, the
background operation, the troubleshooting and the online
upgrading.
Compact Flash
It is reserved as the interface.
CARD
Attribute Description
Connector type RJ45
Standard RS-232
4-10
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Attribute Description
Connector type RJ45
Standard Asynchronous EIA/TIA-232
Baud rate 300 to 115200 bps
PPP
Supported
SLIP
protocol
MP
3) The attributes of the 10/100Base-TX Ethernet port are shown in Table 4-7.
Attribute Description
Connector type RJ45
Ethernet_II
Supported Ethernet_SNAP
frame format IEEE 802.2
IEEE 802.3
Attribute Description
Connector type SFP optical module
Number of
2 1
interfaces
Supported Ethernet_II
frame format Ethernet_SNAP
4-11
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Attribute Description
10M/100Mbps autosensing
Working mode
Full duplex
Supported
network IP
protocol
The technical specifications of the RPU board are shown in Table 4-9.
Parameter Description
Silkscreen RPU
Power
35 W
consumption (W)
4.3 NPU
This section introduces the functions of Network Process Unit (NPU), the board and
the technical specifications of the NE20E.
The board is located in the back slot on the bottom of the case-shape cabinet. NPU
is inserted in the system from the back and corresponds with the RPU.
4.3.1 Functions
NPU consists of the network processor module, the FPGA module, the storage
module and the other attached devices. The board implements the expedited
forwarding of the data packet, including the IP forwarding, MPLS forwarding,
multicast forwarding and QoS. The forwarding rate can reach 6 Mpps.
4-12
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
z Encapsulates and decapsulates the data frame after the data of HIC and FIC
enters the network process module. Encapsulates and decapsulates the data
frame after the high speed interface control packets enter the network process
module.
z Periodically detects the state of the network process module and queries the
board version.
z Updates the logical device of EPLD and FPGA and implements the online loop
and the offline loop of FPGA in the board.
z Monitors the temperature.
z Support the reset of the service interface board and other main modules.
z Supports the CABWatch debugging tool provided by the IBM.
M
N
Component Description
It indicates the running LED. Constant ON means NPU works
RUN (green) normally. Constant OFF means NPU is not in position or has
failed.
ALM (red) It indicates the alarm LED. Constant ON means NPU has fialed.
4-13
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Parameter Description
Silkscreen NPU
Power
58 W
consumption (W)
4.4.1 Functions
10/100Base-TX Ethernet electrical interface module provides the Fast Ethernet (FE)
interface that is used to enable the connection between routers and the LAN.
Silkscreen Description
2FE
4-14
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Silkscreen Description
RT-HIC-2FE
RT-HIC-4FE
RT-HIC-8FE
LED Description
OFF means the link is not connected and ON means the link is
LINK
connected.
Attribute Description
Connector type RJ45
4-15
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Attribute Description
Full duplex/Half-duplex
Operating mode
10M/100 Mbit/s auto-negotiation
Ethernet_II
Supported frame format
Ethernet_SNAP
100Base-FX Ethernet optical interface modules of NE20E series routers are shown
as follows:
z 1-port 100Base-FX Ethernet Multi-mode optical interface module (1MFX)
z 2-port 100Base-FX Ethernet signle/Multi-mode optical interface module
(RT-HIC-2FE-SFP)
z 4-port 100Base-FX Ethernet signle/Multi-mode optical interface module
(RT-HIC-4FE-SFP)
z 8-port 100Base-FX Ethernet signle/Multi-mode optical interface module
(RT-HIC-8FE-SFP)
4.5.1 Functions
100Base-FX Ethernet optical interface module provides the optical interface. The
optical interface enables the routers to communicate with the LAN based on the
quite high realiability and high transmission quality of the fiber.
Silkscreen Description
1MFX
4-16
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Silkscreen Description
RT-HIC-2FE
-SFP
RT-HIC-4FE
-SFP
RT-HIC-8FE
-SFP
100Base-FX Ethernet optical interface attributes are shown in Table 4-17. The SFP
optical module is configured separately and its attributes are shown in Table 4-18.
Item Description
Duplex mode Full duplex
Rate 155 Mbit/s
Applicable standard IEEE 802.3u
4-17
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Item Description
Ethernet_II
Supported frame format
Ethernet_SNAP
Supported network protocol IP
Description
100M single-mode
100M multi-mode optical
Item optical interface
interface module
module
100Base-FX
100Base-FX
Connector type SC
Maximum
15 km 2 km
transmission distance
4.6.1 Functions
1000Base-X Ethernet optical interface module provides the Gigabit Ethernet (GE)
optical interface that enables the communication between routers and the LAN.
4-18
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Silkscreen Description
RT-HIC-1GE
RT-HIC-2GE
Attributes of 1000Base-X Ethernet electrical interface are shown in Table 4-21. The
SFP optical module is configured separately and its attributes are shown in Table
4-22.
Description
Item
2GE 1GE
Connector
LC
type
Interface
2 1
number
4-19
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Description
Item
2GE 1GE
Rate 1.25 Gbit/s
Standard
IEEE 802.3z
compliance
Ethernet_II
Frame format
Ethernet_SNAP
Network
IP
protocol
Description
1000M 1000MS
1000M 1000M
Single-mode ingle-mode
Single-mod Multi-mode
long haul ultra long
e optical optical
Item optical haul optical
interface interface
interface interface
module module
module
1000Base-L 1000Base-S module
1000Base-L
X X 1000Base-LX X
Connector type LC LC LC LC
Minim
Transmitt -9.5 dBm -9.5 dBm -4 dBm -3 dBm
um
ing
power Maxim
-3 dBm -4dBm 1 dBm 2 dBm
um
Minim
Receiver -24 dBm -21 dBm -30 dBm -30 dBm
um
sensitivit
y Maxim
-20.5 dBm -18 dBm -21 dBm -23 dBm
um
Maximum
transmission 10 km 500 m 40 km 70 km
distance
4-20
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
4.7.1 Functions
4-21
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Silkscreen Description
4E1
4E1A
4E1B
4E1-F
4CE1A
4CE1B
4CT1
4-22
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Silkscreen Description
8CE1A
8CE1B
8E1A 8*E1-120ohm
LINK
LINK
ACT ACT
8E1A 8E1A
8E1B
8CT1
4-23
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Attribute Description
Connector type DB-68
75 coaxial cable
Line interface
120 shielded twisted pair cable
75
coaxial 500 m
cable
Maximum
transmit 120
distance shielded
twisted 150 m
pair
cable
ITU-T G.703
Interface standard
G.704
PPP
MP
Supported protocol
Frame Relay
MFR
The channelized E3 interface module only has one type at present, that is, the
1-port channelized E3 module (1cE3).
4.8.1 Functions
4-24
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
z In E3 operating mode, transmit and process E3 high speed data flows; provide
access to E3 data flows.
z In cE3 operating mode, provide N X 64 kbit/s (N=1, 2, , 31) low speed access
services.
Note:
E3 means the thrice primary rate (34.368 Mbit/s) of E series in the time division
multiplexing system. One channel of E3 can be channelized into 16 E1 through
twice demultiplexing processes: E23 (E2 to E3 multiplexing/E3 to E2 demultiplexing
process, here referred to the demultiplexing process) and E12 (E1 to E2
multiplexing/E2 to E1 demultiplexing process, here referred to the demultiplexing
process). Each E1 supports both E1 and cE1 operating modes.
1cE3
LED Description
OFF means the link is not connected and ON means the link is
LINK
connected.
4-25
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Description
Attribute
1cE3
Connector type SMB
Supported network
IP
protocol
PPP
Frame Relay
Supported protocol HDLC
MP
MFR
There is only one kind of synchronous serial interface module, that is, 4-port
enhanced high-speed synchronous serial interface card (4SAE).
4.9.1 Functions
4SAE supports the synchronous working mode. Its main function is to receive, send
and process the synchronous serial data flow and to support the modes of Data
Terminal Equipments (DTE) and the Data Circuit-terminating Equipments (DCE).
4-26
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
The 4SAE card is connected with a Modem and serves as a dialing port. In this case,
you need to set the appropriate baud rate.
The synchronous serial port can work in either DTE mode or DCE mode. Two
directly-connected devices work in DTE mode and DCE mode respectively. In this
case, the DCE device offers the synchronous clock and specifies the baud rate,
while the DTE device receives the synchronous clock and carries out
communication based on the specified baud rate.
Generically, the router serves as a DTE device. For the type (DCE or DTE) of the
device connected with the router, refer to the manual accompanying the device.
For the specified device types, you can see Table 4-29.
In different working modes, the synchronous serial port supports different electric
signal standards and baud rates. The set baud rate and the selected cable
determine the maximum transmission distance of the signal. For the relationship
between cable type, baud rate and maximum transmission distance of signals, see
Table 4-30.
V.24 V.35
4-27
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
V.24 V.35
64000 20 56000 60
115200 10 64000 50
- - 2048000 30
Note:
If the V.24 cable is used, the SA baud rate cannot exceed 64 kbit/s.
Silkscrern Description
4SAE
4-28
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Attribute Description
Connector type DB-28
PPP
HDLC
Supported protocol Frame Relay
MFR
MP
Note:
If the synchronous serial port is connected with a converter, it can offer X.21,
EIA/TIA-449, or EIA-530 interface.
4-29
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
4.10.1 Functions
ATM 155M optical interface module provides the system with the ATM interface. The
functions of the interface are as follows:
z Supports the two frame formats, SDH and SONET.
z Allows scrambling in data transmission.
z Supports both line clock (used when working as DTE interface) and internal
clock (used when working as DCE interface).
z Supports the test measures of local cell loopback, local payload loopback and
remote loopback.
z Supports the hardware flow control and the software resetting.
Silkscreen Description
1ATM-OC3
MM
1ATM-OC3
SM
1ATM-OC3
SML
4-30
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Attributes of ATM 155M optical interface module are shown in Table 4-36. The SFP
optical module is separately configured in the interface module and its attributes are
shown in Table 4-37.
Attribute Description
Connector
SC
type
Interface
155 Mbit/s
rate
Interface
SONET/SDH
standard
ATM Traffic Constant Bit Rate (CBR)
Supported rt_Variable Bit Rate-Real Time (VBR)
services
type nrt_Variable Bit Rate-Non Real Time (VBR)
Unspecified Bit Rate (UBR)
IPoA
Supported IPoEoA
protocol PPPoA
PPPoEoA
4-31
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Table 4-37 Attributes of the optical module with the ATM 155M optical interface
module
Description
The ATM over E3 interface module of the NE20E only has one type, that is, 1-port
ATM over E3 module (1AE3).
4.11.1 Functions
The functions of The ATM over E3 interface module in the system are as follows:
z Supports two ATM cell mapping modes: ATM Direct Mapping (ADM) and
Physical Layer Convergence Protocol (PLCP).
z Allows scrambling in data transmission.
z Supports both line clock (used when working as DTE interface) and internal
clock (used when working as DCE interface).
z Supports the test measures of local cell loopback, local payload loopback and
remote loop.
4-32
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Note:
It is recommended to install only one ATM over E3 interface module on each
Quidway router because multiple such interface modules may affect the
performances of some key services.
Silkscreen Description
1AE3
Item Description
Connector
type SMB (34.368M electrical Interface)
4-33
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Item Description
Interface
75 coaxial cable
cable
Maximum
transmission 100 m
distance
Standard
ITU-T G.703
compliance
Supported IPoEoA
protocol PPPoA
PPPoEoA
Supported
CBR, UBR, nrt_VBR and rt_VBR
service type
4.12.1 Functions
Packet over SDH (POS) interface is a high-speed transport interface which takes
the SONET/SDH network as the transport interface. In sending direction, the POS
interface encapsulates IP data packets received from the NP with the PPP protocol
or HDLC protocol, and then maps the encapsulated data packets to the payload of
the SONET/SDH frame for transmission on the optical network. In receiving
direction, the POS interface receives optical signals, processes them through
reverse operations, and then sends them to the NP.
The POS interface board can be used to connect NE20E routers and SONET/SDH
devices together, or connect NE20E routers directly.
4-34
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
One POS interface module can be channelized into E1 channels, and can provide
63 E1 channels or T1 channels.
Silkscreen Description
1CPOS(E)
RT-HIC-1P
OS
RT-HIC-2P
OS
RT-HIC-4P
OS
4-35
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Item Description
Rate 155 Mbit/s
Unchannelized: 155 Mbit/s and full-duplex
Operating mode
channelized: 63 E1 channels or 84 T1 channels
STM-1/OC-3c SONET/SDH
Applicable standard
IETF RFC1619/1661/1662
Supported network
IP
protocol
PPP
HDLC
Supported protocols
Frame Relay
MFR
4-36
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Description
HSSI interface module of the NE20E series routers are shown as follows:
z 1-port HSSI interface (1HSSI)
z 2-port HSSI interface (2HSSI)
4.13.1 Functions
High Speed Serial Interface (HSSI) is connected by the HSSI cable. In the sending
direction, the IP data packet is PPP or HDLC encapsulated and sent to the HSSI
interface line after being transmitted into the ECL level serial data. In the receiving
direction, the serial ECL level data is transmitted into the TTL level and is processed
with the HDLC frame. Extract the IP data packet in the reverse process and forward
the IP data packet.
The NE20E with the HSSI interface can be connected to the DCE equipment
(CSU/DSU) as the DTE equipment or connected with the DTE equipment back to
back.
4-37
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
z The HSSI interface level is ECL. The highest rate is 52 Mbps and the farthest
transmission distance is 50 inches (15 m).
z Support two loop working modes, that is, the physical chip self-loop and the line
self-loop.
z The interface supports many link layer protocols, such as PPP and HDLC.
z Supports the auto-identification of DTE and DCE and chooses the clock
automatically.
Silkscreen Description
1HSSI
2HSSI
4-38
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board
Item Description
Type HSSI electrical interface
Rate 52 Mbit/s
Working mode Unchannelized: 51.84M
Standard
Compliant with STS-1
compliance
Supported
IP
network protocol
4-39
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Chapter 5 Cable
This chapter introduces the types, the structure and technical parameters of the
external cable used by the NE20E.
The external cables and their usage are shown in Table 5-1.
Channelized/U
Used to connect Refer to
nchannelized
channelized/unchannelized E1/T1 Channelized/Unchannelize
E1/T1 interface
interface to the related equipment. d E1/T1 Interface Cable.
cable
Synchronous
Used to connect the serial interface Refer to Synchronous
serial interface
to the related equipment. Serial Interface Cable.
cable
5-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5.1.1 Introduction
The DC power cable contains the 48 V power cable NEG (), the power grounding
cable RTN (+) and the power protection grounding cable PGND. The power cable
transfers the 48 V DC power from the DC distribution equipment to the terminal
block of the NE20E power module, supplying power for the NE20E equipment.
Note:
The PGND cable of the power does not need to be connected. But the protection
grounding cable located on the back of the power module needs to be well
connected with the protection grounding cable of the chassis.
5.1.2 Structure
The wiring terminal of the NE20E power module is the OT bare pressure terminal.
The outline of DC power cable is shown in Figure 5-1.
1 Main label 2
5-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5.2.1 Introduction
Alternating Current (AC) power cable ranges from 85 V AC to 264 V AC and 50/60
Hz.
The power cable transmits the AC to the terminal block of the NE20E power module
to supply power to the whole NE20E.
5.2.2 Structure
The NE20E AC power cable includes not only Chinese standard AC power cable but
also the local-standard cable in Europe, North America and UK.
5.3.1 Introduction
The console cable is used to connect the NE20E console port to the serial port of
the console device for transmitting configuration data of the equipment.
The console cable is an 8-core shielded cable. One end uses the RJ45 connector
that is connected to the console port of the MPU. The other end has two connectors
with DB9 female and DB25 female respectively, and is connected with the serial port
of the computer. You can choose one of them to plug into the computer serial port
according to the actual condition.
5.3.2 Structure
5-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
D B 25 Fe male
8 P8C PLU G
A B
Pos.1 Pos.8
DB9 Fe male
Enlar ged C side
Pos.1
Pos.1 C
Pos.9
The pin assignments of the console port cables are shown in Table 5-2.
5.4.1 Introduction
The auxiliary (AUX) port cable is used to connect the NE20E AUX port to the
Modem for remote transmission of configuration data.
The AUX port cable is an 8-core shielded cable. One end uses the RJ45 connector
that is connected to the AUX port of the RPU. The other end has two connectors
5-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
with the DB9 (female) and DB25 (female) respectively, and is connected with the
computer serial port. You can choose one of them to plug into the computer serial
port according to the actual condition.
5.4.2 Structure
As shown in Figure 5-2, the structure of the AUX cable is the same as that of the
console cable. The pin assignments of the AUX cables are shown in Table 5-3.
2 20 4 DTR
3 2 3 TXD
4 8 1 DCD
5 - 7 5 GND
6 3 2 RXD
7 6 6 DSR
8 5 8 CTS
5.5.1 Introduction
The Ethernet cable contains two types: the straight-through cable and the crossover
cable. All are 3 m long.
I. Straight-through Cable
Straight through cable is also called standard cable. The wire sequences of the
twisted pairs crimped in the RJ45 connectors at both ends are the same. It is used
for connecting a terminal device (PC or the router) to a HUB or a LAN Switch. The
cables delivered with the equipment are straight-through cables.
Crossover cable is also called direct connection cable. The wire sequences of the
twisted pairs crimped in the RJ45 connectors at both ends are different. It is used for
connecting two terminal devices (PC or the router).
5-5
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5.5.2 Structure
Both straight-through cable and the crossover cable adopt shield cables and RJ45
connectors. The pin assignments are shown in Figure 5-3 and Figure 5-4.
RJ45 RJ45
1 1
2 2
3 3
6 6
RJ45 RJ45
1 1
2 2
3 3
6 6
The pin assignments of straight-through cable and crossover cable are respectively
shown in Table 5-4 and Table 5-5.
2 TX- Orange 2
4 - Blue - 4
5 - White (Blue) - 5
6 RX- Green 6
7 - White (Brown) - 7
8 - Brown - 8
5-6
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
2 TX- Orange 6
4 - Blue - 4
5 - White (Blue) - 5
6 RX- Green 2
7 - White (Brown) - 7
8 - Brown - 8
Note:
Refer to the above table to differentiate and produce two Ethernet cables. Arrange
the line order according to the above chromatogram strictly, or the communication
quality can be affected though the two ends are well connected.
5.6.1 Introduction
NE20E uses the SFP optical module on different optical interface. The
corresponding optical fiber is shown as Table 5-6.
Table 5-6 Relationship between the interface type and corresponding optical fiber
Fiber
Optical
Interface type transmission Length
Connectors
mode
ATM 155M Single-mode/multi
SC/PC 5 m, 10 m, 20 m
optical interface -mode
5-7
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
SFP is in plug-in type. Both multi-mode module and single-mode module can be
plugged on the interface board. Different optical modules and optical connectors
need different fiber. The multi-mode interface module connects with the multi-mode
fiber; the single-mode module connects with the singlemode fiber.
The interfaces of ATM 155M and Ethernet optical module is equipped with SC
optical connector as shown in Figure 5-5. Therefore, you are recommended to use
the fiber with SC/PC optical connector. In addition, the optical interfaces of Gigabit
Ethernet optical interface module and POS optical interface module should apply LC
optical connector as shown in Figure 5-6. Therefore, you are recommended to use
the fiber LC/PC with optical connector.
5-8
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
The plugging or unplugging of LC/PC and SC/PC optical connectors only needs
axial operation instead of rotation. The operation procedures and precautions are as
follows:
When plugging the fiber connector, you should be careful to align the fiber head
with the optical interface, and push in the fiber with proper force.
When pulling the fiber out, you should press the clip first, and then pull the fiber
connector slightly and then plug out the connector.
The NE20E offers two kinds of 4-port interface cables as shown in Figure 5-7 and
Figure 5-8, that is, 4-port E1-F/cE1 coaxial cable and 4-port E1-F/cE1 shielded
twisted pair cable respectively for 75 unshielded interface module and 120
shielded interface module. E1 cable and cE1 cable are completely compatible.
5-9
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
L ab e l 8
L ab e l 7
L ab e l 6
L ab e l 5
L ab e l 4
L ab e l 3
L ab e l 2
L ab e l 1
Pos.1 Pos.68
HPDB 68 male
P0
Dark blue*4
RJ45 connector
Metal shell
X1 X2 X3 X4
Pos.1 Pos.8
The pin assignments of 4E1/4CE1 cables are shown in Table 5-7 and Table 5-8.
5-10
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
2 AGND - -
3 TxTip3 NO.4 transmits
4 TxRing3 NO.4 transmits
5 AGND - -
6 AGND - -
10 - - -
11 TxTip2 NO.3 transmits
12 TxRing2 NO.3 transmits
13 AGND - -
14 AGND - -
19 TxTip1 NO.2 transmits
20 TxRing1 NO.2 transmits
21 AGND - -
22 AGND - -
27 TxTip0 NO.1 transmits
29 AGND - -
30 AGND - -
35 AGND - -
36 RxShield3 - -
37 RxTip3 NO.4 receives
38 RxRing3 NO.4 receives
43 AGND - -
44 RxShield2 - -
45 RxTip2 NO.3 receives
46 RxRing2 NO.3 receives
51 AGND - -
52 RxShield1 - -
53 RxTip1 NO.2 receives
5-11
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
55 AGND - -
59 AGND - -
60 RxShield0 - -
61 RxTip0 NO.1 receives
62 RxRing0 NO.1 receives
67 AGND - -
68 AGND - -
Table 5-8 The pine assignments of 4E1-F/4cE1 shielded twisted pair cable
1 AGND - - -
2 AGND - - -
3 TxTip3 RxTip3 4
4 TxRing3 RxRing3 5
36 RxShield3 TxShield3 3
37 RxTip3 TxTip3 1
38 RxRing3 TxRing3 2
7 TxShield3 RxShield3 6
5 AGND - - -
6 AGND - - -
11 TxTip2 RxTip2 4
12 TxRing2 RxRing2 5
44 RxShield2 TxShield2 3
45 RxTip2 TxTip2 1
46 RxRing2 TxRing2 2
15 TxShield2 RxShield2 6
13 AGND - - -
14 AGND - - -
19 TxTip1 RxTip1 4
5-12
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
52 RxShield1 TxShield1 3
53 RxTip1 TxTip1 1
54 RxRing1 TxRing1 2
23 TxShield1 RxShield1 6
21 AGND - - -
22 AGND - - -
26 TxShield0 RxShield0 6
27 TxTip0 RxTip0 4
28 TxRing0 RxRing0 5
60 RxShield0 TxShield0 3
61 RxTip0 TxTip0 1
62 RxRing0 TxRing0 2
30 AGND - - -
35 AGND - - -
43 AGND - - -
51 AGND - - -
59 AGND - - -
67 AGND - - -
68 AGND - - -
The NE20E offers two kinds of 8-port interface cables as shown in Figure 5-9 and
Figure 5-10. They are the 8-port E1-F/CE1 coaxial cable and the 8-port E1-F/CE1
shielded twisted pair cable. And they are matchable with the 75 unshielded
interface module and the 120 shielded interface module respectively. E1 and CE1
cable are compatible.
5-13
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
A direction
HUAWEI
Back Side Logo
Main label
Quidway
The pin assignments of 8E1/8CE1 cables are shown in Table 5-9 and Table 5-10.
2 DGND - - -
47 CAB_ID0 - - -
5-14
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5 PGND - - -
6 PGND - - -
13 PGND - - -
14 PGND - - -
21 PGND - - -
22 PGND - - -
30 PGND - - -
29 PGND - - -
5-15
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
35 PGND - - -
39 PGND - - -
43 PGND - - -
51 PGND - - -
59 PGND - - -
67 DGND - - -
68 DGND - - -
Table 5-10 The pin assignments of 8E1-F/8cE1/8cT1 shielded twisted pair cable
2 DGND - - -
3 TxTip3 TxTip3 4
4 TxRing3 TxRing3 5
7 TxShield3 TxShield3 6
36 RxShield3 RxShield3 3
37 RxTip3 RxTip3 1
5-16
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5 PGND - - -
6 PGND - - -
11 TxTip2 TxTip2 4
12 TxRing2 TxRing2 5
15 TxShield2 TxShield2 6
44 RxShield2 RxShield2 3
45 RxTip2 RxTip2 1
46 RxRing2 RxRing2 2
13 PGND - - -
14 PGND - - -
19 TxTip1 TxTip1 4
20 TxRing1 TxRing1 5
23 TxShield1 TxShield1 6
52 RxShield1 RxShield1 3
53 RxTip1 RxTip1 1
54 RxRing1 RxRing1 2
21 PGND - - -
22 PGND - - -
27 TxTip0 TxTip0 4
28 TxRing0 TxRing0 5
31 TxShield0 TxShield0 6
60 RxShield0 RxShield0 3
61 RxTip0 RxTip0 1
62 RxRing0 RxRing0 2
30 PGND - - -
29 PGND - - -
9 TxTip7 TxTip7 4
10 TxRing7 TxRing7 5
8 TxShield7 TxShield7 6
40 RxShield7 RxShield7 3
5-17
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
42 RxRing7 RxRing7 2
17 TxTip6 TxTip6 4
18 TxRing6 TxRing6 5
16 TxShield6 TxShield6 6
48 RxShield6 RxShield6 3
49 RxTip6 RxTip6 1
50 RxRing6 RxRing6 2
25 TxTip5 TxTip5 4
26 TxRing5 TxRing5 5
24 TxShield5 TxShield5 6
56 RxShield5 RxShield5 3
57 RxTip5 RxTip5 1
58 RxRing5 RxRing5 2
33 TxTip4 TxTip4 4
34 TxRing4 TxRing4 5
32 TxShield4 TxShield4 6
64 RxShield4 RxShield4 3
65 RxTip4 RxTip4 1
66 RxRing4 RxRing4 2
35 PGND - - -
39 PGND - - -
43 PGND - - -
51 PGND - - -
59 PGND - - -
67 DGND - - -
68 DGND - - -
CT1 interface module of NE20E applies the 100 shielded twisted pair cable.
5-18
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
4CT1cable outline is shown in Figure 5-8. The pin assignments are shown in Table
5-8. 8CT1cable outline is shown in Figure 5-10. The pin assignments are shown in
Table 5-10.
5.8.1 Introduction
1cE3 interface module provide two SMB interfaces which are respectively
connected to the Tx end and Rx end of the peer device. The interfaces work in
75-ohm unbalanced transfer mode and are connected with the peer device through
a pair of 75-ohm unbalanced coaxial cables.
5.8.2 Structure
5.9.1 Introduction
Every 4SAE interface is 28-core connectors. One end is DB28 connector to connect
with the router and the other end differs according to the network segment. Both are
3 m long.
5-19
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5.9.2 Structure
5-20
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5-21
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
1 TxD+ 2 TxD
19 RxD+ 3 RxD
5-22
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
13 RTS+ 4 RTS
23 CTS+ 5 CTS
27 DTR+ 20 DTR
25 DSR+ 6 DSR
17 RxC+ 17 RxC
3 TxC+ 15 TxC
15 TxCE+ 24 ETC
11 DCD+ 8 DCD
22 LL 18 LIST
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
19 RxD+ 2 TxD
1 TxD+ 3 RxD
23 CTS+ 4 RTS
13 RTS+ 5 CTS
25 DSR+ 20 DTR
27 DTR+ 6 DSR
15 TxCE+ 17 RxC
3 TxC+ 15 TxC
17 RxC+ 24 ETC
11 DCD+ 8 DCD
22 LL 18 LIST
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - A Circuit GND
5-23
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
21 GND - B Shield GND
1 TxD+ P SD+
2 TxD- S SD-
19 RxD+ R RD+
20 RxD- T RD-
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - A Circuit GND
21 GND - B Shield GND
19 RxD+ P TxD+
20 RxD- S TxD-
1 TxD+ R RxD+
2 TxD- T RxD-
23 CTS+ C RTS
13 RTS+ D CTS
25 DSR+ H DTR
27 DTR+ E DSR
15 TxCE+ V SCR+
16 TxCE+ X SCR-
3 TxC+ Y SCT+
4 TxC+ AA SCT-
17 RxC+ U SCTE+
18 RxC- W SCTE-
11 DCD+ F RLSD
22 LL J LL
5-24
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 8 Circuit GND
21 GND - 1 Shield GND
13 RTS+ 3 Control+
14 RTS- 10 Control-
23 CTS+ 5 Indication+
24 CTS- 12 Indication -
19 RxD+ 4 Receiver+
20 RxD- 11 Receiver-
1 TxD+ 2 Transmit+
2 TxD- 9 Transmit-
17 RxC+ 6 Timing+
18 RxC- 13 Timing-
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 8 Circuit GND
21 GND - 1 Shield GND
13 RTS+ 5 Indication+
14 RTS- 12 Indication -
23 CTS+ 3 Control+
24 CTS- 10 Control-
19 RxD+ 2 Transmit+
20 RxD- 9 Transmit-
1 TxD+ 4 Receiver+
2 TxD- 11 Receiver-
15 TxCE+ 6 Timing+
16 TxCE- 13 Timing-
5-25
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 19 Circuit GND
21 GND - 1 Shield GND
27 DTR+ 12 TR+
28 DTR- 30 TR -
25 DSR+ 11 DM+
26 DSR- 29 DM-
13 RTS+ 7 RS+
14 RTS- 25 RS-
23 CTS+ 9 CS+
24 CTS- 27 CS-
11 DCD+ 13 RR+
12 DCD- 31 RR-
22 LL/LL 10 LL
19 RxD+ 6 RD+
20 RxD- 24 RD-
1 TxD+ 4 SD+
2 TxD- 22 SD-
15 TxCE+ 17 TT+
16 TxCE- 35 TT-
17 RxC+ 8 RT+
18 RxC- 26 RT-
3 TxC+ 5 ST+
4 TxC- 23 ST-
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 19 Circuit GND
21 GND - 1 Shield GND
27 DTR+ 11 DM+
5-26
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
28 DTR- 29 DM-
25 DSR+ 12 TR+
26 DSR- 30 TR -
13 RTS+ 9 CS+
14 RTS- 27 CS-
23 CTS+ 7 RS+
24 CTS- 25 RS-
11 DCD/DCD+ 13 RR+
12 DCD/DCD- 31 RR-
22 LL/LL 10 LL
19 RxD+ 4 SD+
20 RxD- 22 SD-
1 TxD+ 6 RD+
2 TxD- 24 RD-
15 TxCE+ 8 RT+
16 TxCE- 26 RT-
17 RxC+ 17 TT+
18 RxC- 35 TT-
3 TxC+ 5 ST+
4 TxC- 23 ST-
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
27 DTR+ 20 DTR+
28 DTR- 23 DTR-
25 DSR+ 6 DSR+
26 DSR- 22 DSR -
13 RTS+ 4 RTS+
5-27
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
14 RTS- 19 RTS-
23 CTS+ 5 CTS+
24 CTS- 13 CTS-
11 DCD/DCD+ 8 DCD+
12 DCD/DCD- 10 DCD-
22 LL/LL 18 LL
19 RxD+ 3 RxD+
20 RxD- 16 RxD-
1 TxD+ 2 TxD+
2 TxD- 14 TxD-
15 TxCE+ 24 TxCE+
16 TxCE- 11 TxCE-
17 RxC+ 17 RxC+
18 RxC- 9 RxC-
3 TxC+ 15 TxC+
4 TxC- 12 TxC-
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
25 DSR+ 20 DTR+
26 DSR- 23 DTR-
27 DTR+ 6 DSR+
28 DTR- 22 DSR -
23 CTS+ 4 RTS+
24 CTS- 19 RTS-
13 RTS+ 5 CTS+
14 RTS- 13 CTS-
11 DCD/DCD+ 8 DCD+
5-28
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
12 DCD/DCD- 10 DCD-
22 LL/LL 18 LL
1 TxD+ 3 RxD+
2 TxD- 16 RxD-
19 RxD+ 2 TxD+
20 RxD- 14 TxD-
17 RxC+ 24 TxCE+
18 RxC- 11 TxCE-
15 TxCE+ 17 RxC+
16 TxCE- 9 RxC-
3 TxC+ 15 TxC+
4 TxC- 12 TxC-
Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
25 DSR+ 20 DTR+
26 DSR- 23 DTR-
27 DTR+ 6 DSR+
28 DTR- 22 DSR -
23 CTS+ 4 RTS+
24 CTS- 19 RTS-
13 RTS+ 5 CTS+
14 RTS- 13 CTS-
11 DCD/DCD+ 8 DCD+
12 DCD/DCD- 10 DCD-
22 LL/LL 18 LL
1 TxD+ 3 RxD+
2 TxD- 16 RxD-
5-29
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Signal
DB-28 Signal DB-25 Signal
Direction
19 RxD+ 2 TxD+
20 RxD- 14 TxD-
17 RxC+ 24 TxCE+
18 RxC- 11 TxCE-
15 TxCE+ 17 RxC+
16 TxCE- 9 RxC-
3 TxC+ 15 TxC+
4 TxC- 12 TxC-
5.10.1 Introduction
The outward interface of 1AE3 has two SMB plugs, corresponding to Tx and Rx
respectively. The interface is the 75 unbalanced transmission mode, connecting
with the remote device by the 75 balanced coaxial cable. The lengths of cables
are 15 m and 30 m respectively. Users can choose the cable in the whole set of the
external cables the according to their needs.
5.10.2 Structure
5-30
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
5.11.1 Introduction
High Speed Serial Interface cable has two types, that is, the DTE-to-DCE cable
(HSSI Interface Cable) and the DTE-to-DTE (Null Modem Cable). All are 3 m long.
I. DTE-to-DCE Cable
DTE-to-DCE cable is the straight-through cable. The line sequences of the twisted
pairs in the (DB-50) SCSI-II connectors of the two ends are the same. They are
used for the connection between the HSSI interface and the communication device
in the middle.
DTE-to-DTE cable is the crossover cable. The line sequences of the twisted pairs in
the (DB-50) SCSI-II connectors of the two ends are different. They are used for the
back-to-back connection among the DTE devices.
5.11.2 Structure
DTE-to-DCE cable and DTE-to-DTE cable are both the shielded twisted pair cables.
They adopt the (DB-50) SCSI-II and have the similar pin assignments as shown in
Figure 5-23.
A B
W1
A B
Label
X0 X1
5-31
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
Table 5-22 The pin assignments of the DTE-to-DCE cable (HSSI Interface Cable)
(DB50) (DB50)S
Relation Color Signal Direction Signal
SCSI-II CSI-II
White 1 SG 1 SG
Pair 1 -
Blue 26 SG 26 SG
White 2 RT+ 2 RT+
Pair 2 Orang
27 RT- 27 RT-
e
Black 13 SG 13 SG
Pair 13 -
Green 38 SG 38 SG
ancillary ancillary to
Pair 14 Black 14 - 14
to DCE DCE
5-32
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
(DB50) (DB50)S
Relation Color Signal Direction Signal
SCSI-II CSI-II
ancillary ancillary to
Brown 39 39
to DCE DCE
ancillary ancillary to
Black 15 15
to DCE DCE
Pair 15 -
ancillary ancillary to
Gray 40 40
to DCE DCE
ancillary ancillary to
Yellow 16 16
to DCE DCE
Pair 16 -
ancillary ancillary to
Blue 41 41
to DCE DCE
ancillary ancillary to
Yellow 17 17
to DCE DCE
Pair 17 -
Orang ancillary ancillary to
42 42
e to DCE DCE
ancillary ancillary to
Yellow 18 18
to DCE DCE
Pair 18 -
ancillary ancillary to
Green 43 43
to DCE DCE
Yellow 19 SG 19 SG
Pair 19
Brown 44 SG 44 SG
ancillary
ancillary
Yellow 20 from 20
from DCE
DCE
Pair 20 -
ancillary
ancillary
Gray 45 from 45
from DCE
DCE
ancillary
ancillary
Violet 21 from 21
from DCE
DCE
Pair 21 -
ancillary
ancillary
Blue 46 from 46
from DCE
DCE
ancillary
ancillary
Violet 22 from 22
from DCE
DCE
Pair 22 -
ancillary
Orang ancillary
47 from 47
e from DCE
DCE
ancillary
ancillary
Pair 23 Violet 23 from - 23
from DCE
DCE
5-33
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
(DB50) (DB50)S
Relation Color Signal Direction Signal
SCSI-II CSI-II
ancillary
ancillary
Green 48 from 48
from DCE
DCE
ancillary
ancillary
Violet 24 from 24
from DCE
DCE
Pair 24 -
ancillary
ancillary
Brown 49 from 49
from DCE
DCE
Violet 25 SG 25 SG
Pair 25 -
Gray 50 SG 50 SG
Table 5-23 The pin assignments of the DTE-to-DTE cable (Null Modem Cable)
(DB50)SC (DB50)SC
Relation Color Signal Direction Signal
SI-II SI-II
White 1 SG - 1 SG
Pair 1
Blue 26 SG - 26 SG
Not
White 5 LC+ 10 LA+
connect
Pair 5
Not
Gray 30 LC- 35 LA-
connect
Not
Red 6 ST+ 6 ST+
connect
Pair 6
Not
Blue 31 ST- 31 ST-
connect
Red 7 SG - 7 SG
Pair 7
Orange 32 SG - 32 SG
5-34
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
(DB50)SC (DB50)SC
Relation Color Signal Direction Signal
SI-II SI-II
Loopb
Loopbac
ack(no
k(not
Black 12 t - 12
connecte
conne
d)
cted)
Pair 12
Loopb
Loopbac
ack(no
k(not
Orange 37 t - 37
connecte
conne
d)
cted)
Black 13 SG - 13 SG
Pair 13
Green 38 SG - 38 SG
Not
Black 14 - 14 Not used
used
Pair 14
Not
Brown 39 - 39 Not used
used
Not
Black 15 - 15 Not used
used
Pair 15
Not
Gray 40 - 40 Not used
used
Not
Yellow 16 - 16 Not used
used
Pair 16
Not
Blue 41 - 41 Not used
used
Not
Yellow 17 - 17 Not used
used
Pair 17
Not
Orange 42 - 42 Not used
used
5-35
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable
(DB50)SC (DB50)SC
Relation Color Signal Direction Signal
SI-II SI-II
Not
Yellow 18 - 18 Not used
used
Pair 18
Not
Green 43 - 43 Not used
used
Yellow 19 SG - 19 SG
Pair 19
Brown 44 SG - 44 SG
Not
Yellow 20 - 20 Not used
used
Pair 20
Not
Gray 45 - 45 Not used
used
Not
Violet 21 - 21 Not used
used
Pair 21
Not
Blue 46 - 46 Not used
used
Not
Violet 22 - 22 Not used
used
Pair 22
Not
Orange 47 - 47 Not used
used
Not
Violet 23 - 23 Not used
used
Pair 23
Not
Green 48 - 48 Not used
used
Not
Violet 24 - 24 Not used
used
Pair 24
Not
Brown 49 - 49 Not used
used
Violet 25 SG - 25 SG
Pair 25
Gray 50 SG - 50 SG
Note:
Refer to the above table to differ and produce two Ethernet cables. Arrange the line
order according to the above chromatogram strictly.
5-36
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators
The status and description of RPU indicators are shown in Table A-1.
A-1
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators
The status and description of NPU indicators are shown in Table A-2.
Name Description
It indicates the running LED. Constant ON means NPU works
RUN (Green) normally. Constant OFF means NPU is not in position or has
failed.
It indicates the alarm LED. Constant ON means NPU has
ALM (Red)
failed.
The status and description of HIC/FIC indicators are shown in Table A-3.
A-2
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators
Name Description
OFF means the link is not connected and ON means the link is
LINK (Green)
connected.
A-3
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators
The running state of the power module is available from the indicators of the RPU
front panel. The status and description of the indicators are shown in Table A-6.
Table A-6 Indicators of the power module on the RPU front panel
A-4
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
B.1 Boards
B-1
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
B.2 RPU
Attribute Description
Connector type RJ-45
Standard RS-232
Baud rate 9600 bps to 115200 bps
9600 bps by default
Attribute Description
Connector type RJ-45
Standard Asynchronous EIA/TIA-232
Baud rate 300 to 115200 bps
B-2
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Attribute Description
PPP
Supported
SLIP
protocol
MP
The attributes of the 10/100Base-TX Ethernet port are shown in Table B-4.
Attribute Description
Connector type RJ-45
Standard MDI
Ethernet_II
Supported Ethernet_SNAP
frame format IEEE 802.2
IEEE 802.3
10/100 Mbps autosensing
Operating
Full duplex
mode
Half-duplex
Supported
network IP
protocol
Attribute Description
Connector type SFP optical module
Number of
2 1
interfaces
Supported Ethernet_II
frame format Ethernet_SNAP
10M/100Mbps autosensing
Working mode
Full duplex
Supported
network IP
protocol
B-3
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
The attributes of the 10/100Base-TX FE Electrical Interface are shown in Table B-6.
Attribute Description
Connector type RJ45
The attributes of the 100Base-FX Ethernet optical interface are shown in Table B-8.
Item Description
SFP optical interface. For the module
Interface type
configuration, see Table B-8.
Duplex mode Full duplex
Rate 155 Mbit/s
Applicable standard IEEE 802.3u
Ethernet_II
Supported frame format
Ethernet_SNAP
B-4
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Description
100M single-mode
100M multi-mode optical
Item optical interface
interface module
module
100Base-FX
100Base-FX
Connector type SC SC
Transmitt Minimum -15 dBm -19 dBm
ing
power Maximum -8 dBm -14 dBm
The attributes of the 1000Base-X Ethernet optical interface are shown in Table B-9.
Description
Item
2GE 1GE
Interface
2 1
number
Duplex mode Full duplex
Rate 1.25 Gbit/s
Standard
IEEE 802.3z
compliance
Ethernet_II
Frame format
Ethernet_SNAP
Network
IP
protocol
B-5
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Description
1000M 1000MS
1000M 1000M
Single-mode ingle-mode
Single-mod Multi-mode
long haul ultra long
e optical optical
Item optical haul optical
interface interface
interface interface
module module
module
1000Base-L 1000Base-S module
1000Base-L
X X 1000Base-LX X
Connector type LC LC LC LC
Minim
Transmitt -9.5 dBm -9.5 dBm -4 dBm -3 dBm
um
ing
power Maxim
-3 dBm -4dBm 1 dBm 2 dBm
um
Minim
Receiver -24 dBm -21 dBm -30 dBm -30 dBm
um
sensitivit
y Maxim
-20.5 dBm -18 dBm -21 dBm -23 dBm
um
Maximum
transmission 10 km 500 m 40 km 70 km
distance
Attribute Description
75 coaxial cable
Line interface
120 shielded twisted pair cable
B-6
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Attribute Description
75
coaxial 500 m
Maximum cable
transmit 120
distance shielded
150 m
twisted
pair cable
ITU-T G.703
Interface standard
G.704
PPP
MP
Supported protocol
Frame Relay
MFR
The attributes of the synchronous serial port are shown in Table B-12.
Attribute Description
B-7
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Attribute Description
PPP
HDLC
Supported protocol Frame Relay
MFR
MP
The attributes of the synchronous serial port are shown in Table B-13.
Attribute Description
Interface
155 Mbit/s
rate
Interface
SONET/SDH
standard
ATM Traffic Constant Bit Rate (CBR)
Supported rt_Variable Bit Rate-Real Time (VBR)
services
type nrt_Variable Bit Rate-Non Real Time (VBR)
Unspecified Bit Rate (UBR)
B-8
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Attribute Description
IPoA
Supported IPoEoA
protocol PPPoA
PPPoEoA
Table B-14 Attributes of the optical module with the ATM 155M optical interface
Description
Maximum transmission
2 km 15 km 30 km
distance
Item Description
Connector
SMB (34.368M electrical Interface)
type
Interface
75 coaxial cable
cable
Maximum
transmission 100 m
distance
B-9
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Item Description
Standard
ITU-T G.703
compliance
Rate 34.368 Mbit/s
IPoA
Supported IPoEoA
protocol PPPoA
PPPoEoA
Supported
CBR, UBR, nrt_VBR and rt_VBR
service type
Item Description
Supported network
IP
protocol
PPP
HDLC
Supported protocols
Frame Relay
MFR
B-10
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards
Description
Connector type LC LC LC LC
Item Description
Type HSSI electrical interface
Rate 52 Mbit/s
Working mode Unchannelized: 51.84M
Standard
Compliant with STS-1
compliance
Supported
IP
network protocol
B-11
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents
Table of Contents
i
Hardware Description
Quidway NetEngine20E Series Routers Appendix C Acronyms and Abbreviations
A
AC Alternating Current
ATM Advanced Traffic Management
AUX Auxiliary (port)
C
CPU Central Processing Unit
CSU Channel service unit
D
DC Direct Current
DCD Data Carrier Detect
DCE Data Circuit-terminating Equipment
DSR Data Set Ready
DSU Data Service Unit
DTE Data Terminal Equipments
DTR Data Terminal Ready
E
EMC Electro Magnetic Compatibility
EPLD Erasable Programmable Logic Device
F
FE Fast Ethernet
FIC Flexible Interface Card
FPGA Field Programmable Gate Array
G
GE Gigabit Ethernet
GND Ground
C-1
Hardware Description
Quidway NetEngine20E Series Routers Appendix C Acronyms and Abbreviations
H
HDLC High-level Data Link Control
HIC High-speed Interface Card
I
IEEE Institute of Electrical and Electronics Engineers
IETF Internet engineering task force
IP Internet Protocol
ISDN Integrated Services Digital Network
L
LAN Local Area Network
LC Lucent Connector
LD Laser Diode
LED Light-emitting diode
M
MFR Multiple Frame Relay
MP Multilink Protocol
MPLS Multiprotocol Label Switching
MTBF Mean Time Between Failure
MTTR Mean Time To Repair
N
NEG Negative
NPU Network Process Unit
NVRAM Non-Volatile Random Access Memory
O
ODF Optical Distribution Frame
P
PC Personal Computer
PGND Protection Ground
C-2
Hardware Description
Quidway NetEngine20E Series Routers Appendix C Acronyms and Abbreviations
Q
QoS Quality of Service
R
RH Relative Humidity
RJ45 Registered Jack 45
RPM Round Per Minute
RPU Routing Process Unit
S
SA Security Association
SC Square Connector
SDH Synchronous Digital Hierarchy
SDRAM Synchronous Dynamic Random Access Memory
SFP Small Form-Factor Pluggable
SLIP Serial Line Internet Protocol
SMB Sub-miniature B
SNAP Sub Network Access Point
SONET Synchronous Optical Network
ST Segment Type
U
UBR Unspecified Bit Rate
UL Underwriter Laboratories Inc.
V
VBR Variable Bit Rate
C-3
Hardware Description
Quidway NetEngine20E Series Routers Index
Index
i-1
Hardware Description
Quidway NetEngine20E Series Routers Index
H R
HIC, 1-1, 4-3 relationship between the interface type and
corresponding optical fiber, 5-7
I RPU, 1-1, 3-2, 4-6, 4-7, 4-8, 4-9, A-1, B-2
L T
LPU technical parameter
indicator, A-3 fan module, 3-3
NPU NPU
O technical parameter, 4-14
pin assignment
DTE-to-DCE cable, 5-32 X
RS530 DCE cable, 5-29 X.21 DCE cable, 5-21, 5-25
V.24 DCE cable, 5-23 X.21 DTE cable, 5-21, 5-25
V.24 DTE cable, 5-22
i.
i-2