Sie sind auf Seite 1von 128

HUAWEI

Quidway NetEngine20E Series Routers


Hardware Description

V200R003

Huawei Technologies Proprietary


Quidway NetEngine20E Series Routers
Hardware Description

Manual Version 03 (2007-06-15)

Product Version V200R003

BOM 31250477

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support
and service. If you purchase the products from the sales agent of Huawei Technologies Co.,
Ltd., please contact our sales agent. If you purchase the products from Huawei
Technologies Co., Ltd. directly, Please feel free to contact our local office, customer care
center or company headquarters.

Huawei Technologies Co., Ltd.

Address: Administration Building, Huawei Technologies Co., Ltd.,

Bantian, Longgang District, Shenzhen, P. R. China

Postal Code: 518129

Website: http://www.huawei.com

Huawei Technologies Proprietary


Copyright Huawei Technologies Co., Ltd. 2007. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any


means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co.,


Ltd.

All other trademarks and trade names mentioned in this document are the
property of their respective holders.

Notice

The information in this document is subject to change without notice. Every effort
has been made in the preparation of this document to ensure accuracy of the
contents, but all statements, information, and recommendations in this document
do not constitute the warranty of any kind, express or implied.

Huawei Technologies Proprietary


About This Manual

Release Notes

The version of product corresponded with the manual is V200R003.

Related Manuals

The related manuals and usages of the Quidway NetEngine20E Series Routers are
listed in the following table.

Manual Content
It introduces the installation of NE20E Series
Quidway NetEngine20E Routers, including the board installation, the cable
Series Routers Installation installation, the NE20E start, the hardware
Manual maintenance, the label specification and the
grounding specification.
It introduces the NE20E Series Routers hardware,
Quidway NetEngine20E
including the equipment introduction, the power
Series Routers Hardware
module, the heat dissipation system, the board, the
Description
equipment cable and some appendixes.
Operation Manual is organized into eight volumes
and every volume has many chapters, including the
overview of the volume and the configuration of the
attributes. The appendix introduces the
Quidway NetEngine20/20E abbreviations in the volume.
Series Routers Operation
Manual Every attribute configuration contains introduction,
configuration tasks, maintenance, configuration
examples and troubleshooting.
It is organized into eight volumes as given below:
It describes the configuration of the system
management and the reliability, including the
establishment of the configuration environment, the
System Volume basic configuration, the user login, the file
management, the system maintenance, NTP,
SNMP, backup center, VRRP, reliability, GR and
abbreviations.

Huawei Technologies Proprietary


Manual Content
It describes various interfaces and configurations of
the protocols in the link layer, such as Ethernet
interface, serial port, E-carrier and T-carrier, POS
Access Volume and cPOS, virtual interface, VLAN, PPP and MP,
X.25 and LAPB, frame relay, HDLC, ATM, fast
feeling, interface flap control, PPPoE and
abbreviations.
It describes the configurations of IP-related
services, including the IP address, ARP, DNS,
IP Services Volume DHCP, IP performance, IP unicast policy route,
ACL, IPv6 basic, IPv6 application, NAT-PT, IPv6
over IPv4 tunnel and abbreviations.
It describes the configurations of routing protocols,
including static route, RIP, RIPng, OSPF, OSPFv3,
IP Routing Volume IS-IS, BGP, BGP4+, routing policy, IP Multicast
Overview, IGMP, PIM, MSDP, MBGP, multicast
policy and abbreviations.

MPLS Volume It describes MPLS, MPLS TE and abbreviations.

It describes VPN configurations, including VPN


tunnel management, L2TP protocol, GRE protocol,
VPN Volume
BGP/MPLS IP VPN, MPLS L2VPN and
VPN-Instance application, VPLS and abbreviations.

It introduces the QoS configuration of the HIC and


the FIC, including traffic management, traffic
shaping, congestion management, congestion
QoS Volume avoidance, class-based QoS, link efficiency
mechanism, frame relay QoS, ATM QoS, MPLS
QoS, QoS optimized configuration of the FIC, VLAN
QoS, TE QoS and abbreviations.
It describes the configuration of the security
attributes, including AAA and user management,
Security Volume
firewall, NAT, port mirroring, abbreviations and
attribute table of RADIUS and HWTACACS.
The command reference is organized into eight
chapters mapping with the corresponding volume of
Quidway NetEngine20/20E the operation manual. It gives explanation for the
Series Routers Command commands of system, access, IP service, IP
Reference routing, MPLS, VPN, QoS and security. The
appendix provides the index of all these
commands.

Organization

The manual is named the Quidway NetEngine20E Series Routers Hardware


Description. Its contents are as follows:

Huawei Technologies Proprietary


Chapter 1 Overview describes the device structure, the system configuration and the
physical parameter.

Chapter 2 Power Supply describes the DC and AC power module according to the
outline, the front panel, the function and the technical specifications of the power
module.

Chapter 3 Heat Dissipation System describes the system according to the


introduction, the outline, the front panel, the function and the technical specifications
of the fan.

Chapter 4 Board introduces the classification of the board, the slot allocation, the
interface types and the allocation on the board. And it also describes every board
according to the function, the front panel, the interface description, the attributes and
technical specifications.

Chapter 5 Cable introduces the external cable introduction. It introduces it according


to the introduction, the structure and the technical specification.

Appendixes A to C contain the following three appendixes: the Indicator List, the
Board List, and the acronym and Abbreviation. In the daily maintenance, you can
quickly look up the related information about the device by the appendixes.

Index collates important keywords used in this manual to help the reader to access
the required information quickly.

Intended Audience

The manual is intended for the following readers:


z Network administrators
z Network engineers
z Configuration operators

Conventions

I. General conventions

Convention Description
Arial Normal paragraphs are in Arial.

Boldface Headings are in Boldface.

Terminal Display is in Courier New. The information


Courier New entered by users on the terminal or that needing attentions
in Terminal Display is in bold Courier New.

Huawei Technologies Proprietary


II. Symbols

Eye-catching symbols are also used in the manual to highlight the points worthy of
special attention during the operation. They are defined as follows:

Caution, Warning, Danger: Means reader be extremely careful during the


operation.

Note, Comment, Tip, Knowhow, Thought: Means a complementary


description.

Huawei Technologies Proprietary


Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Chapter 1 Overview ....................................................................................................................... 1-1


1.1 Introduction ........................................................................................................................ 1-1
1.2 Structure ............................................................................................................................ 1-1
1.3 System Configuration and Physical Specifications............................................................ 1-3
1.3.1 System Configuration.............................................................................................. 1-3
1.3.2 Physical Specifications............................................................................................ 1-4

Chapter 2 Power Module .............................................................................................................. 2-1


2.1 Appearance and Front Panel............................................................................................. 2-1
2.1.1 Appearance ............................................................................................................. 2-1
2.1.2 Front Panel.............................................................................................................. 2-1
2.2 Functions ........................................................................................................................... 2-3
2.3 Technical Specifications .................................................................................................... 2-4

Chapter 3 Heat Dissipation System............................................................................................. 3-1


3.1 Appearance and Front Panel............................................................................................. 3-1
3.1.1 Appearance ............................................................................................................. 3-1
3.1.2 Front Panel.............................................................................................................. 3-2
3.2 Functions ........................................................................................................................... 3-2
3.3 Technical Specifications .................................................................................................... 3-3

Chapter 4 Board............................................................................................................................. 4-1


4.1 Introduction ........................................................................................................................ 4-1
4.1.1 Board Classification and Slot Distribution ............................................................... 4-1
4.1.2 Board Appearance .................................................................................................. 4-3
4.1.3 Interface Types and Distribution on the Board........................................................ 4-4
4.2 RPU ................................................................................................................................... 4-6
4.2.1 Functions................................................................................................................. 4-6
4.2.2 Front Panel.............................................................................................................. 4-7
4.2.3 Interfaces................................................................................................................. 4-9
4.2.4 Interface Attributes ................................................................................................ 4-10
4.2.5 Technical Specifications........................................................................................ 4-12
4.3 NPU ................................................................................................................................. 4-12
4.3.1 Functions............................................................................................................... 4-12
4.3.2 Front Panel............................................................................................................ 4-13
4.3.3 Technical Specifications........................................................................................ 4-14
4.4 10/100Base-TX Electrical Interface Module .................................................................... 4-14
4.4.1 Functions............................................................................................................... 4-14
4.4.2 Front Panel............................................................................................................ 4-14

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

4.4.3 Interface Attributes ................................................................................................ 4-15


4.5 100Base-FX Ethernet Optical Interface Module .............................................................. 4-16
4.5.1 Functions............................................................................................................... 4-16
4.5.2 Front Panel............................................................................................................ 4-16
4.5.3 Interface Attributes ................................................................................................ 4-17
4.6 1000Base-X Ethernet Optical Interface Module .............................................................. 4-18
4.6.1 Functions............................................................................................................... 4-18
4.6.2 Front Panel............................................................................................................ 4-18
4.6.3 Interface Attributes ................................................................................................ 4-19
4.7 Channelized/Unchannelized E1/T1 Interface Module ..................................................... 4-21
4.7.1 Functions............................................................................................................... 4-21
4.7.2 Front Panel............................................................................................................ 4-21
4.7.3 Interface Attributes ................................................................................................ 4-24
4.8 Channelized E3 Interface Modules.................................................................................. 4-24
4.8.1 Functions............................................................................................................... 4-24
4.8.2 Front Panel............................................................................................................ 4-25
4.8.3 Interface Attributes ................................................................................................ 4-26
4.9 Synchronous Serial Port Module ..................................................................................... 4-26
4.9.1 Functions............................................................................................................... 4-26
4.9.2 Front Panel............................................................................................................ 4-28
4.9.3 Interface Attributes ................................................................................................ 4-29
4.10 ATM 155M Optical Interface Module ............................................................................. 4-30
4.10.1 Functions............................................................................................................. 4-30
4.10.2 Front Panel.......................................................................................................... 4-30
4.10.3 Interface Attributes .............................................................................................. 4-31
4.11 ATM Over E3 Interface Module ..................................................................................... 4-32
4.11.1 Functions............................................................................................................. 4-32
4.11.2 Front Panel.......................................................................................................... 4-33
4.11.3 Interface Attributes .............................................................................................. 4-33
4.12 Channelized or Unchannelized POS Optical Interface Modules ................................... 4-34
4.12.1 Functions............................................................................................................. 4-34
4.12.2 Front Panel.......................................................................................................... 4-35
4.12.3 Interface Attributes .............................................................................................. 4-36
4.13 HSSI Interface Module................................................................................................... 4-37
4.13.1 Functions............................................................................................................. 4-37
4.13.2 Front Panel.......................................................................................................... 4-38
4.13.3 Interface Attributes .............................................................................................. 4-38

Chapter 5 Cable ............................................................................................................................. 5-1


5.1 DC Power Cable ................................................................................................................ 5-2
5.1.1 Introduction.............................................................................................................. 5-2
5.1.2 Structure.................................................................................................................. 5-2
5.2 AC Power Cable ................................................................................................................ 5-3

Huawei Technologies Proprietary

ii
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

5.2.1 Introduction.............................................................................................................. 5-3


5.2.2 Structure.................................................................................................................. 5-3
5.3 Console Port Cable............................................................................................................ 5-3
5.3.1 Introduction.............................................................................................................. 5-3
5.3.2 Structure.................................................................................................................. 5-3
5.4 Auxiliary Port Communication Cable ................................................................................. 5-4
5.4.1 Introduction.............................................................................................................. 5-4
5.4.2 Structure.................................................................................................................. 5-5
5.5 Ethernet Cable ................................................................................................................... 5-5
5.5.1 Introduction.............................................................................................................. 5-5
5.5.2 Structure.................................................................................................................. 5-6
5.6 Optical Fiber....................................................................................................................... 5-7
5.6.1 Introduction.............................................................................................................. 5-7
5.6.2 Optical Connector ................................................................................................... 5-8
5.7 Channelized/Unchannelized E1/T1 Interface Cable.......................................................... 5-9
5.7.1 4E1-F/4CE1 Interface Cable ................................................................................... 5-9
5.7.2 8E1-F/8CE1 Interface Cable ................................................................................. 5-13
5.7.3 4CT1/8CT1 Interface Cable .................................................................................. 5-18
5.8 Channelized E3 Interface Cable ...................................................................................... 5-19
5.8.1 Introduction............................................................................................................ 5-19
5.8.2 Structure................................................................................................................ 5-19
5.9 Synchronous Serial Interface Cable ................................................................................ 5-19
5.9.1 Introduction............................................................................................................ 5-19
5.9.2 Structure................................................................................................................ 5-20
5.10 ATM over E3 Interface Cable ........................................................................................ 5-30
5.10.1 Introduction.......................................................................................................... 5-30
5.10.2 Structure.............................................................................................................. 5-30
5.11 HSSI Cable .................................................................................................................... 5-31
5.11.1 Introduction.......................................................................................................... 5-31
5.11.2 Structure.............................................................................................................. 5-31

Appendix A List of Indicators ......................................................................................................A-1


A.1 Board Indicators ................................................................................................................A-1
A.1.1 RPU Indicators........................................................................................................A-1
A.1.2 NPU Indicators........................................................................................................A-2
A.1.3 HIC/FIC Indicators ..................................................................................................A-2
A.2 Fan Module Indicators.......................................................................................................A-3
A.3 Power Module Indicators...................................................................................................A-3

Appendix B List of Boards ...........................................................................................................B-1


B.1 Boards ...............................................................................................................................B-1
B.2 RPU ...................................................................................................................................B-2
B.3 10/100Base-TX FE Electrical Interface Module ................................................................B-4
B.4 100Base-FX Ethernet Optical Interface Module................................................................B-4

Huawei Technologies Proprietary

iii
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

B.5 1000Base-X Ethernet Optical Interface Module................................................................B-5


B.6 Channelized or Unchannelized E1/T1 Interface Module...................................................B-6
B.7 Synchronous Serial Port Module.......................................................................................B-7
B.8 ATM 155M Optical Interface Module.................................................................................B-8
B.9 ATM Over E3 Interface Module.........................................................................................B-9
B.10 Channelized or Unchannelized POS Optical Interface Module ....................................B-10
B.11 HSSI Interface Module ..................................................................................................B-11

Appendix C Acronyms and Abbreviations .................................................................................C-1

Huawei Technologies Proprietary

iv
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Chapter 1 Overview ....................................................................................................................... 1-1


1.1 Introduction ........................................................................................................................ 1-1
1.2 Structure ............................................................................................................................ 1-1
1.3 System Configuration and Physical Specifications............................................................ 1-3
1.3.1 System Configuration.............................................................................................. 1-3
1.3.2 Physical Specifications............................................................................................ 1-4

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview

Chapter 1 Overview

The chapter introduces the structure, the system configuration and the physical
specifications of Quidway NetEngine20E Series Routers.

1.1 Introduction

Huaweis Quidway NetEngine20E Series Routers (hereafter referred to as NE20E


for short) is designed according to the roadmap of designing other high-end routers
developed by Huawei. It is targeted at the carrier aggregation layer and the
enterprise backbone layer network based on its own advantages, such as high
performance, double Routing Process Units (RPU), double Network Process Units
(NPU) and hot backup.

At present, NE20E only has NE20E-8 with adopts the modularized structure and
provides the High-speed Interface Card (HIC) and the Flexible Interface Card (FIC).

The hardware structure of the NE20E provides the following maintainable attributes:
z Supports hot swap.
z Adopts the backplane in the middle. The boards are inserted in the backplane
horizontally. The structure is convenient for the configuration and maintenance.
z The fan is located on the left of the router backplane. It uses multiple fans to
carry out the ventilation for the requirements of heat dissipation.
Besides, NE20E has effective monitoring system. It manages and maintains the
whole system by the main control module on the Routing Process Unit (RPU). RPU
can manage, monitor and maintain the board, the fan module and the power
module.

NE20E abide by the Electro Magnetic Compatibility (EMC) and the Underwriter
Laboratories Inc. (UL). The whole system reaches the module-class shield level.
Every handle is made of steel sheet to isolate the electromagnetic wave of boards.

1.2 Structure

The NE20E-8 adopts the backplane in the middle and the integrated chassis with
the board inserted horizontally. The chassis is 6 U (1 U = 44.45 mm) high and can
be mounted in a 19-inch standard cabinet or on the workbench.

Huawei Technologies Proprietary

1-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview

I. Front Panel

1 2

AC

LIN

AC

LIN

AC

LIN
AL

R
N

FA

PW
PW 1

1
R 2

TX

TX

R
T

T
PU
PU

PU

K
ES

1
N
M

X
R
R
10

1
2

ET
SYS RUN PRN LINK LINK
NPU MST ALM ACT ACT
CompactFlash CARD RPU
10/100BASE TX AUX CONSOLE 10/100/1000MEthernet 0 10/100/1000MEthernet 1

AC

LIN

AC

LIN

AC

LIN
PW
PW 1

1
AL

R
N

FA

R 2

TX

TX

R
K

K
PU
PU

PU

ES

1
N
M

X
R
R
9
1
2

ET
SYS RUN PRN LINK LINK
NPU MST ALM ACT ACT
10/100BASE TX AUX CONSOLE 10/100/1000MEthernet 0 10/100/1000MEthernet 1 CompactFlash CARD RPU

LINK 7 8
LINK LINK
ACT ACT
2FE 2FE 4SAE 4SAE
0 10Base-T/100Base-TX 1 0 1 ACT 2 3

8*EI-120ohm 8*EI-120ohm 5 6
LINK LINK LINK LINK
ACT ACT ACT ACT
8EIA 0 1 2 3 4 5 6 7 8EIA 8EIA 8EIA

R
TX
0
3 4

X
LINK LINK LINK
ACT ACT ACT
2FE 10Base-T/100Base-TX 2FE RT-HIC-1POS
0 1

1 3 5 7
LIN

LIN

1 2
R

R
TX

TX
0

1
X

X
K

RT-HIC-2POS RT-HIC-8FE
AC

AC

0 2 4 6
T

11 10 9 8 7 6 5 4 3
2. RPU 1-slot 9 3.ESD-preventive wrist strap
1. RPU 2-slot 10
jack
4. FIC/HIC interface 5. FIC/HIC interface module 6. FIC interface module slot 6
module slot 2 slot 4
7. FIC interface module 8. FIC interface module slot 9. FIC interface module slot 5
slot 8 7
10. FIC/HIC interface 11. FIC/HIC interface
module slot 3 module slot 1
Figure 1-1 Front panel of the NE20E-8 router

II. Rear Panel

1 2 3 4 5 6 7 8
R

AL
U

M
N

FAN NPU
R

AL
U

M
N

D o nt u s e th is h a n d le

to lif t s u b ra c k
CA U T IO N
NPU

DO NO T
TO UC H T HE
FAN L EAVE S
BEF OR E T HE Y
S L O W DO WN
A

R
AL
C

UN
OK

100-240V
A

R
AL
C

UN
OK

100-240V

11 10 9
1. Fan module 2.NPU 1 3. NPU 2
4.Filler panel 5.Filler panel 6. Power module 1 (PWR1)
7.Power module 2 9. AD Power interface
8. Grounding screw
(PWR2)
11. ESD-preventive wrist
10. Power switch
strap jack
Figure 1-2 Rear panel of the NE20E-8 router

NE20E-8 is designed as an integrated cabinet. For the details of its main


components and introduction, see Table 1-1.

Huawei Technologies Proprietary

1-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview

Table 1-1 Components of NE20E-8

Name Introduction Description


Fan module It is located on the left of the backplane and Refer to Chapter
used for the heat dissipation. Every cabinet 3 Heat
must be configured with one fan module. Dissipation
System.
Card It has four types, that is, RPU, NPU, the FIC Refer to Chapter
and the HIC, which can be inserted into the 5 Board.
board slot.

Power module It is located in the two slots at the backplane Refer to Chapter
bottom. Every cabinet must be configured 2 Power
with two power modules and one 1+1 Supply.
backup. The NE20E provides the AC power
module and the DC power module.

Cable It contains the power cable, fiber and the Refer to Chapter
external whole-set cable. 6 Cable.

1.3 System Configuration and Physical Specifications

1.3.1 System Configuration

The system configuration data is shown in Table 1-2.

Table 1-2 Data table of system configuration

Item NE20E-8
Number of slots 12
Maximum number of
8
interface boards
Fan backup Redundancy backup 2 x 4

DC and AC power supply modules for the 1+1


Power backup
redundancy backup respectively
One AUX port
One Console port
Fixed interface
One 10/100BASE-TX Ethernet interface
Two 10/100/1000M Ethernet interfaces
PowerPC 7447
CPU processor
967 MHz
Boot ROM 512 KB x 2

Huawei Technologies Proprietary

1-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview

Item NE20E-8
SDRAM 512 M (default), can be extended to 2G

NVRAM 512 KB
Flash 64 MB
Packet transmission rate 6 Mpps

Switching capacity 16 Gbps


Transmission attribute 1GE wire speed transmission
Mean Time Between
More than 51.8 years
Failure (MTBF)
Mean Time To Repair
Less than 30 minutes
(MTTR)
Availability More than 0.99999

Note:
z Synchronous Dynamic Random Access Memory (SDRAM) specifies the memory
that stores the communication data between the system and CPU.
z As the storage medium of the significant files, Non-Volatile Random Access
Memory (NVRAM) stores the configuration files and the record of the system
running state.
z Flash memory functions as the major file storage medium to store the operating
system and the application program files.
z Boot ROM stores the boot program file when the system is started.

1.3.2 Physical Specifications

The physical specifications of the NE20E are shown in Table 1-3.

Table 1-3 Physical specifications

Item NE20E-8
Cabinet Structure Integrated cabinet, 6 U
Height
263.9 mm
(H)
Width
Dimension 436.2 mm
(W)
Depth
480.0 mm
(D)

Huawei Technologies Proprietary

1-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 1 Overview

Item NE20E-8
Rated voltage range: 100 V AC to 240 V AC; 50/60Hz
AC
Input Maximum voltage range: 90 V AC to 264 V AC; 50/60Hz
voltage Rated voltage range: 48 V DC
DC
Maximum voltage range: 72 V DC to 36 V DC
Maximum configuration
32 Kg
weight

Maximum power
320 W
consumption

Module RPU 30 W
consumpti
on NPU 58 W

Operating Long term 0 to 45


temperatu
re Short term 5 to 55

Storage temperature 40 to 70

Relative Long term 5% RH to 85% RH (non-condensing)


humidity Short term 0% RH to 95% RH (non-condensing)
Storage relative
0% RH to 95% RH
humidity
Long-term operating
< 3000 m
altitude
Storage altitude < 5000 m

Note:
z The measurement point of the temperature and humidity is 1.5 m over the floor
and 0.4 m in front of the cabinet. There should be no protection board at the front
or back of the cabinet.
z Short-term operation means that the continuous working time does not exceed
48 hours and the accumulated time per year does not exceed 15 days.

Huawei Technologies Proprietary

1-5
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Chapter 2 Power Module .............................................................................................................. 2-1


2.1 Appearance and Front Panel............................................................................................. 2-1
2.1.1 Appearance ............................................................................................................. 2-1
2.1.2 Front Panel.............................................................................................................. 2-1
2.2 Functions ........................................................................................................................... 2-3
2.3 Technical Specifications .................................................................................................... 2-4

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module

Chapter 2 Power Module

The chapter introduces the appearance and the front panel of the power module, the
function and the technical parameters of the NE20E-8.

2.1 Appearance and Front Panel

2.1.1 Appearance

The NE20E-8 provides two types of the power module, that is, the AC input and the
DC input. The appearance of the AC power module is shown in Figure 2-1. And the
appearance of the DC power module is shown in Figure 2-2.
AC

AL
R
U

M
N
O
K

Figure 2-1 Appearance of the AC power supply module

Figure 2-2 Appearance of the DC power supply module

2.1.2 Front Panel

The appearance of the front panel of the AC power module is shown in Figure 2-3.
The appearance of the front panel of the DC power module is shown in Figure 2-4.

Huawei Technologies Proprietary

2-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module

100-240V

100-240V

Figure 2-3 Front panel of the AC power module

-48~-60V

-48~-60V

Figure 2-4 Front panel of the DC power module

Table 2-1 Relationship of the terminal block connection of the power input cable

Identifier of
Input cable Input cable
the terminal Input cable interface
name color
block

RTN (+) Power


grounding Black JG double-hole bare pressure
cable terminal block.
NEG (-) Power cable Blue

Protection
PGND grounding Kelly Need not to be connected.
cable
Note:
z RTN: Return
z NEG: Negative
z PGND: Protection Ground

As shown in Table 2-2 and Table 2-3, the running state of the power module is
available from the indicators of the RPU front panel.

Huawei Technologies Proprietary

2-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module

Table 2-2 Description of the indicators of the AC power supply module

Name Color Description

It indicates the power module input LED (only for


AC Power module).
AC OK Green Constant ON means the normal voltage (100 V to
240 V) is inputting, and OFF means the voltage
input is not normal.

It indicates the power Module indicators.

RUN Green Constant ON means the power module runs


normally, and OFF means the power module has
faults.

It indicates indicator for the power module fault.


ALM Red Constant ON means the power module has faults
or is not in position.

Table 2-3 Description of the indicators of the DC power supply module

Indicator Color Description

It indicates the state of input DC (only for DC


Power module).
DC OK Green Constant ON means the normal voltage (-48 V to
-60 V) is inputting, and OFF means the voltage
input is not normal.

It indicates the power module LED.

RUN Green Constant ON means the power module runs


normally, and OFF means the power module has
faults.

It indicates the power module failure


ALM indicator Red LED.Constant ON means the power module is not
in position or has faults.

The running state of the power module is available from the indicators of the RPU
front panel. For details, refer to RPU of Chapter 4 Board.

2.2 Functions

The NE20E-8 provide two types of the power modules, that is, the AC input and the
DC input. The power modules are inserted in the backplane from the back.

Huawei Technologies Proprietary

2-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module

Usually, two power modules work in the redundancy backup mode. The AC and the
DC power modules are the PSR550-A and the PSR550-D power respectively. The
power line adopts the -48V feeder cable of D 3PIN.

The power module has the following functions:


z When one of the power input is interrupted or some defects occur to the power
module, the other one is not affected and can provide the power to the whole
system. If the system needs to be powered off, you need to power off all the
configured power modules.
z The power module provides various protection functions, including the input
over-voltage protection, the input under-voltage protection, the output over-flow
protection, the output over-voltage protection, the output short circuit protection
and the over-heat protection.
z The power module supports the hot swap. The switching of the power module
does not affect the system running.

Note:
If you want to install an NE20E in the communication equipment room, you need to
make sure that the power distribution cabinet can provide the lightning protection box
or arrester against the current of 20 KA and above.

2.3 Technical Specifications

Technical specifications of the LCD are shown in Table 2-4.

Table 2-4 Technical parameters of the power module

Item Technical specifications


Dimensions 40.14mm (H) x 350.00mm (W) x 224.30mm (D)

Weight 1.5 kg
Input rated 100 V AC to 240 V AC
voltage AC
50/60 Hz
Input
voltage DC -48 V DC to -60 V DC

Maximum 85 V AC to 264 V AC
input AC
current 50/60 Hz

Input
surge DC -36V DC to -72V DC
current

Huawei Technologies Proprietary

2-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 2 Power Module

Item Technical specifications


Maximum AC 10 A
output
current DC 25 A

Input surge current 36 A


Maximum output
60 A (3.3 V) 20 A (5 V) 30 A (12 V)
current
Maximum output
550 W
power

Huawei Technologies Proprietary

2-5
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Chapter 3 Heat Dissipation System............................................................................................. 3-1


3.1 Appearance and Front Panel............................................................................................. 3-1
3.1.1 Appearance ............................................................................................................. 3-1
3.1.2 Front Panel.............................................................................................................. 3-2
3.2 Functions ........................................................................................................................... 3-2
3.3 Technical Specifications .................................................................................................... 3-3

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 3 Heat Dissipation System

Chapter 3 Heat Dissipation System

The NE20E-8 heat dissipation system consists of:


z Fan module
z Air filter
The air filter and the fan module are placed separately. The air filter is located on the
right of the cabinet backplane. You can directly clean it after taking it out from the back
of the cabinet. For the details of the replacement and cleaning of the air filter, refer to
Quidway NetEngine20E Series Routers Installation Manual.

This chapter introduces the fan function, the fan appearance, the front panel and the
technical specifications of the NE20E-8.

3.1 Appearance and Front Panel

3.1.1 Appearance

The fan of the NE20E-8 is located on the left of the cabin backplane. It ventilates the
panel and dissipates the heat. The fan supports the hot swap.

The fan module contains the fan frame and the fan components. The appearance of
the fan module is shown in Figure 3-1.

Figure 3-1 Appearance of the fan in the NE20E-8

Huawei Technologies Proprietary

3-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 3 Heat Dissipation System

3.1.2 Front Panel

The fan module panel is shown in Figure 3-2.

FAN

Donuse this handle

CAUTION to lift subrack

DO NOT
TOUCH TH E
FAN LE AVE S
BEFORE THEY
SLOW DOWN

Figure 3-2 Appearance of the fan front panel of NE20E-8

The indicators for warning the state of the fan module are located on the RPU front
panel. The indicators of the fan module on the RPU are described in Table 3-1.

Table 3-1 Description of the indicators of the fan module

Name Color Description


RUN Green Constant ON means the FAN is operating normally.
ALM Red ON means some defaults occur to the FAN.

3.2 Functions

The rev of the fan module is controlled by the RPU. The fans working normally can
keep NE20E-8 working in the normal temperature. Its functions contain:
z The fan module can modify the rev automatically. It configures two parameters,
the low-temperature threshold and the high-temperature threshold. The
low-temperature threshold and the high-temperature threshold correspond with
the revs of 100% and 50% respectively. For the operation requirements on the
temperature, see Chapter 1 Product Overview.

Huawei Technologies Proprietary

3-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 3 Heat Dissipation System

z As the failure of a fan does not affect the operation of other fans, the system can
still be able to operate in the normal temperature.
z The system sends out rotation stop alarm signals in case any fan fails.
The heat dissipation system of the NE20E-8 dissipates the heat by ventilating the
NE20E-8. From the top, you can see the air flow enters the NE20E-8 from left and
comes out from right. The air flow inside the NE20E-8 is shown in Figure 3-3.

Fan module frame

Figure 3-3 Air flow inside the NE20E-8

3.3 Technical Specifications


Technical specifications of the fan module are shown in Table 3-2.

Table 3-2 Technical specifications of the fan module

Item Specifications
Dimensions 259.45 mm (H) x 47.70 mm (W) x 462.65 mm (D)
Power
38.4 W
consumption

Maximum
blast 75 Pa
pressure
Maximum 3
921.6 m /h
blast volume
Maximum
60 dB
noise
Maximum
3800 RPM
rev
Operating
voltage 7.0 V to 13.8 V DC
range

Operating
12 V DC
voltage

Huawei Technologies Proprietary

3-3
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Chapter 4 Board............................................................................................................................. 4-1


4.1 Introduction ........................................................................................................................ 4-1
4.1.1 Board Classification and Slot Distribution ............................................................... 4-1
4.1.2 Board Appearance .................................................................................................. 4-3
4.1.3 Interface Types and Distribution on the Board........................................................ 4-4
4.2 RPU ................................................................................................................................... 4-6
4.2.1 Functions................................................................................................................. 4-6
4.2.2 Front Panel.............................................................................................................. 4-7
4.2.3 Interfaces................................................................................................................. 4-9
4.2.4 Interface Attributes ................................................................................................ 4-10
4.2.5 Technical Specifications........................................................................................ 4-12
4.3 NPU ................................................................................................................................. 4-12
4.3.1 Functions............................................................................................................... 4-12
4.3.2 Front Panel............................................................................................................ 4-13
4.3.3 Technical Specifications........................................................................................ 4-14
4.4 10/100Base-TX Electrical Interface Module .................................................................... 4-14
4.4.1 Functions............................................................................................................... 4-14
4.4.2 Front Panel............................................................................................................ 4-14
4.4.3 Interface Attributes ................................................................................................ 4-15
4.5 100Base-FX Ethernet Optical Interface Module .............................................................. 4-16
4.5.1 Functions............................................................................................................... 4-16
4.5.2 Front Panel............................................................................................................ 4-16
4.5.3 Interface Attributes ................................................................................................ 4-17
4.6 1000Base-X Ethernet Optical Interface Module .............................................................. 4-18
4.6.1 Functions............................................................................................................... 4-18
4.6.2 Front Panel............................................................................................................ 4-18
4.6.3 Interface Attributes ................................................................................................ 4-19
4.7 Channelized/Unchannelized E1/T1 Interface Module ..................................................... 4-21
4.7.1 Functions............................................................................................................... 4-21
4.7.2 Front Panel............................................................................................................ 4-21
4.7.3 Interface Attributes ................................................................................................ 4-24
4.8 Channelized E3 Interface Modules.................................................................................. 4-24
4.8.1 Functions............................................................................................................... 4-24
4.8.2 Front Panel............................................................................................................ 4-25
4.8.3 Interface Attributes ................................................................................................ 4-26
4.9 Synchronous Serial Port Module ..................................................................................... 4-26
4.9.1 Functions............................................................................................................... 4-26

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

4.9.2 Front Panel............................................................................................................ 4-28


4.9.3 Interface Attributes ................................................................................................ 4-29
4.10 ATM 155M Optical Interface Module ............................................................................. 4-30
4.10.1 Functions............................................................................................................. 4-30
4.10.2 Front Panel.......................................................................................................... 4-30
4.10.3 Interface Attributes .............................................................................................. 4-31
4.11 ATM Over E3 Interface Module ..................................................................................... 4-32
4.11.1 Functions............................................................................................................. 4-32
4.11.2 Front Panel.......................................................................................................... 4-33
4.11.3 Interface Attributes .............................................................................................. 4-33
4.12 Channelized or Unchannelized POS Optical Interface Modules ................................... 4-34
4.12.1 Functions............................................................................................................. 4-34
4.12.2 Front Panel.......................................................................................................... 4-35
4.12.3 Interface Attributes .............................................................................................. 4-36
4.13 HSSI Interface Module................................................................................................... 4-37
4.13.1 Functions............................................................................................................. 4-37
4.13.2 Front Panel.......................................................................................................... 4-38
4.13.3 Interface Attributes .............................................................................................. 4-38

Huawei Technologies Proprietary

ii
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Chapter 4 Board

The chapter introduces the board classification, the board appearance and the
interface type and describes the technical details of the every board, including:
z Functions
z Board
z Interface attributes

4.1 Introduction

From the introduction in the chapter, you can know the board classification, the
board appearance, the interface type and the interface distribution on the board.

4.1.1 Board Classification and Slot Distribution

I. Board Classification

The board types supported by the NE20E are as follows:


1) Routing Process Unit (RPU)
2) Network Process Unit (NPU)
3) Flexible Interface Card (FIC), including:
z 2-port 10/100Base-TX FE electrical interface module (2FE)
z 1-port 100Base-FX Ethernet multi-mode optical interface module (1MFX)
z 4-port channelized E1 module (4CE1)
z 4-port unchannelized E1 module (4E1-F)
z 8-port channelized E1 module (8CE1)
z 8-port unchannelized E1 module (8E1-F)
z 4-port channelized T1 module (4CT1)
z 8-port channelized T1 module (8CT1)
z 8-port unchannelized E1 module (8E1-F)
z 4-port channelized T1 module (4CT1)
z 8-port channelized T1 module (8CT1)
z 4-port multiprotocol synchronous serial interface module (4SAE)
z 1-port ATM 155M multi-mode optical interface module (1ATM-OC3MM)
z 1-port ATM 155M single-mode optical interface module (1ATM-OC3SM)
z 1-port ATM 155M single-mode long-haul optical interface module
(1ATM-OC3SML)
z 1-port ATM over E3 module (1AE3)
z 1-port channelized POS optical interface module (1CPOS(E))

Huawei Technologies Proprietary

4-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

z 1-port HSSI interface module (1HSSI)


z 2-port HSSI interface module (2HSSI)

Note:
The NE20E router with the host software version of VRP5.30-23134002 or later
supports application of the HSSI interface.

4) High-speed Interface Card (HIC), including:


z 2-port 10/100Base-TX FE electrical interface module (RT-HIC-2FE)
z 4-port 10/100Base-TX FE electrical interface module (RT-HIC-4FE)
z 8-port 10/100Base-TX FE electrical interface module (RT-HIC-8FE)
z 2-port 100Base-FX optical interface module (RT-HIC-2FE-SFP)
z 4-port 100Base-FX optical interface module (RT-HIC-4FE-SFP)
z 8-port 100Base-FX optical interface module (RT-HIC-8FE-SFP)
z 1-port 1000Ethernet optical interface module (RT-HIC-1GE)
z 2-port 1000Ethernet optical interface module (RT-HIC-2GE)
z 1-port unchannelized POS/155M optical interface module (RT-HIC-1POS)
z 2-port unchannelized POS/155M optical interface module (RT-HIC-2POS)
z 4-port unchannelized POS/155M optical interface module (RT-HIC-4POS)

II. Slot Distribution

The board slots of NE20E-8 is shown in Figure 4-1.

RPU 10

RPU 9

FIC FIC 7 8

FIC FIC 5 6

FIC HIC/FIC 3 4

HIC/FIC HIC/FIC 1 2

Figure 4-1 NE20E-8 board slots

The RPU can be only inserted into the slots 9 and 10 on the top of the front panel of
the chassis. The NPU can be only inserted into the two slots on the top of the rear
panel of the chassis

Huawei Technologies Proprietary

4-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

HIC can only be inserted into the slots 1, 2 or 4. The FIC can be inserted into the
slots 1 to 8.

4.1.2 Board Appearance

Caution:

Wear an ESD-preventive wrist strap and keep it well-grounded whenever you touch
the board to prevent the ESD from damaging the board.

Warning:
Do not let your eyes near or stare at the optical interface or the fiber interface. The
laser bean is harmful to your eyes.

The appearances of RPU, NPU and HIC/FIC are respectively shown in Figure 4-2,
Figure 4-3 and Figure 4-4. Take the 8E1A as the example.

1 2 3

PW PW
R1 R
2

13 12 11 10 9 8 7 7 6 5 4

1. Connector 2.Guiding jack 3.Board


4.Board silkscreen 5. Handle 6. Reserved interface
7. 10/100/1000M Ethernet 8. CONSOLE port 9. AUX port
interface
10. 10/100Base-TX Ethernet 11. Reset key 12. Indicator
interface
13. Captive screw
Figure 4-2 Description of RPU components

Huawei Technologies Proprietary

4-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

6 5 4 3 2

1. Connector 2. Board silkscreen 3. Handle


4. Board 5. Indicator 6. Captive screw
Figure 4-3 Description of NPU components

1 2

7 6 5 4 3

1. Connector 2. Front panel 3. Board silkscreen


4. Handle 5. Interface 6. Indicator
7. Captive screw

Figure 4-4 Description of HIC/FIC components

The board dimensions is shown in Table 4-1.

Table 4-1 Board dimensions

Name Dimensions
RPU 399.15 mm (W) x 236 mm (D) x 35.06 mm (H)
NPU 372.45 mm (W) x 238 mm (D) x 35.06 mm (H)

HIC/FIC 198.55 mm (W) x 243.19 mm (D) x 40.14 mm (H)

4.1.3 Interface Types and Distribution on the Board

All interfaces are integrated on the board and imported from the board. The interface
distributions on the board are shown in Table 4-2.

Huawei Technologies Proprietary

4-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-2 Interface distribution on the board

Interface Interface Interface Interface


Board name
classification name attribute type
RT-HIC-2FE-SFP
Single-mode
SC RT-HIC-4FE-SFP
optical interface
100Base- RT-HIC-8FE-SFP
FX
Ethernet 1MFX
optical
interface Multi-mode RT-HIC-2FE-SFP
SC
optical interface RT-HIC-4FE-SFP
RT-HIC-8FE-SFP
Single-mode
optical interface

Single-mode long
1000Base haul optical RT-HIC-1GE
FX interface
Ethernet LC RT-HIC-2GE
optical Single-mode ultra
interface long haul optical RPU
interface
Multi-mode
Opitcal
optical interface
interface
Single-mode
1ATM-OC3SM
optical interface
155M
Single-mode long
ATM
haul optical SC 1ATM-OC3SML
optical
interface
interface
Multi-mode
1ATM-OC3MM
optical interface

Single-mode
short haul optical
interface

Single-mode long 1CPOS(E)


POS haul optical
RT-HIC-1POS
optical interface LC
interface RT-HIC-2POS
Single-mode ultra
long haul optical RT-HIC-4POS
interface

Multi-mode
optical interface

Huawei Technologies Proprietary

4-5
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Interface Interface Interface Interface


Board name
classification name attribute type
2FE
10/100Ba
se-TX FE 10M/100 Mbit/s RT-HIC-2FE
RJ45
electrical autosensing RT-HIC-4FE
Electical Interface
interface RT-HIC-8FE
ATM over 34.368M
E3 electrical SMB 1AE3
interface interface
High-spee
d
Serial port synchrono DTE/DCE DB-28 4SAE
us serial
port

Ethernet 10M/100 Mbit/s


RJ45 RPU
Interface autosensing
Electrical
Console
interface of - RJ45 RPU
interface
maitenance
AUX
- RJ45 RPU
interface

4.2 RPU

This section introduces the functions of Routing Process Unit (RPU), the board, the
interface and the technical specifications.

RPU is located in either of two slots on the bottom of the case-shape cabinet. The
RPU is inserted in the front panel and corresponds with the NPU in the system.

4.2.1 Functions

RPU is the system main control board of the NE20E. It consists of PowerPC
processor, the system controller bridge, the storage and other attached devices.
RPU monitors the system ports, manages the equipment and processes various
software protocols. It is the significant component of the NE20E.

RPU has the following functions:


z Processing the routing protocol.
z Receiving and sends the FIC packets.
z Managing the interface state.
z Monitoring the state of the power system.

Huawei Technologies Proprietary

4-6
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

z Monitoring the state of the fan system.


z Monitoring the system temperature.
z Supports the configuration and management of the active and standby NPUs.
z Configuring and manages the high speed interface.
z Supporting the active and standby switchover.
z Supporting the hot swap.
z Supporting the warm and cold backup.
Besides, RPU provides two GE ports. It supports the exclusion of the optical
function and the electrical function on the GE port, that is, you cannot use the optical
function and the electrical function on the GE port at the same time.

4.2.2 Front Panel

The panel appearance is shown in Figure 4-5. The components are described in
Table 4-3.
LI
AC

N
K
T

LI
AC

N
1

K
T

TX

R
1
X
LINK
10/100BASE TX AUX CONSOLE ACT
10/100/1000M Ethernet 1
AC

LIN

AC

LIN

AC

LIN
0

1
AL

FA

T
K

K
PU

PU

PU

PU

PU

TX

TX

R
ES
M

1
X

X
1

ET

SYS RUN PRN LINK LINK


NPU MST ALM ACT ACT
CompactFlash CARD RPU
10/100BASE TX AUX CONSOLE 10/100/1000M Ethernet 0 10/100/1000M Ethernet 1
N
N 1

N
N 1
R 2
R
AL

FA
PU
PU

PU
PU
ES
PU
M

N
2

ET

SYS RUN PRN


NPU MST ALM

Figure 4-5 Appearance of the RPU front panel

Huawei Technologies Proprietary

4-7
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-3 Description of the RPU front panel components

Name Silkscreen Description


It indicates the system running LED,
including the warnings of fan, power
supply and NPU. Constant ON means
SYS
the RPU has revcieved the warning,
ALM (red) such as the warning of supply power
and fan.

It indicates the NPU failure LED.


NPU Constant ON means the NPU has
failed.

RUN It indicates the system running LED.


Blinking means RPU works normally.
Constant ON or OFF meas RPU has
RPU (green) failed.

MST It indicates the standby state LED.


Constatn ON means the standby
RPU.

It indicates the system running LED.


Blinking means the NPU is in normal
RUN
operation. Constant ON or OFF
NPU1 (green) means the NPU has failed.

It indicates the standby state LED.


MST Constatn ON means the standby
RPU.

It indicates the system running LED.


Blinking means the NPU is in normal
RUN
operation. Constant ON or OFF
NPU2 (green) means the NPU has failed.

It indicates the standby state LED.


MST Constatn ON means the standby
RPU.

It indicates the LED of the fan in


PRN (green) position. Constant ON means the fan
is in position.
FAN
It indicates the fan warning LED.
ALM (red) Constant ON means the fan is not in
position or its rotation is obstructed.

It indicates the LED of the first power


module in position. Constant ON
means the power module is in
PRN (green)
position. Constant OFF means the
PWR1 power module is not in position or has
failed.

It indicates the first power module


ALM (red) failure LED. Constant ON means the
power module has failed.

Huawei Technologies Proprietary

4-8
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Name Silkscreen Description


It indicates the LED of the sencond
power module in position. Constant
ON means the power module is in
PRN (green)
position. Constant OFF means the
PWR2 power module is not in position or has
failed.

It indicates the second power module


ALM (red) failure LED. Constant ON means the
power module has failed.

It indicates the RPU hardware reset


RESET button and is used to restart the
device.

OFF means the link is not connected


LINK (green)
and ON means the link is connected.
10/100Base-TX OFF means no data is being
interface LED transmitted or received on the
ACT (yellow)
interface and blinking means data is
being transmitted and received.

OFF means the link is not connected


LINK (green)
and ON means the link is connected.
10/100/1000M OFF means no data is being
Ethernet 0 LED transmitted and received on the
ACT (yellow)
interface and blinking means data is
being transmitted and received.

OFF means the link is not connected


LINK (green)
and ON means the link is connected.
10/100/1000M OFF means no data is being
Ethernet 1 LED transmitted and received on the
ACT (yellow)
interface and blinking means data is
being transmitted and received.

4.2.3 Interfaces

The interfaces on the RPU and their usage are shown in Table 4-4.

Huawei Technologies Proprietary

4-9
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-4 The interfaces on the RPU and their usage

Item Description
It indicates the local debugging serial port.
It can be connected with the terminal end of characters or
the serial ports of the local PC. And the terminal emulation
program can be operated on the PC.
Console port
It can be used as the CLI and also be use for the board or
system debugging, testing, the serial port printing, the
background operation, the troubleshooting and the online
upgrading.

AUX port can also be named remote debugging physical


interface.
It provides the remote configuration, connects the modem
AUX port and establishes the connection with the remote router by
dialing.
When some faults occur to console port, you can use the
AUX port as the console port.
It has the remote login Telnet function and can be used for
the board or system debugging, testing, the background
10/100Base-TX port
operation, the fault diagnosis, the online upgrading and
the remote operation.

10/100/1000M It can be used as the normal GE port to support the


Ethernet interface configuration service.

Compact Flash
It is reserved as the interface.
CARD

4.2.4 Interface Attributes

1) The attributes of the console port are shown in Table 4-5.

Table 4-5 Console interface attributes

Attribute Description
Connector type RJ45
Standard RS-232

Baud rate 9600 bps to 115200 bps


9600 bps by default

2) The attributes of the AUX port are shown in Table 4-6.

Huawei Technologies Proprietary

4-10
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-6 AUX interface attributes

Attribute Description
Connector type RJ45
Standard Asynchronous EIA/TIA-232
Baud rate 300 to 115200 bps
PPP
Supported
SLIP
protocol
MP

3) The attributes of the 10/100Base-TX Ethernet port are shown in Table 4-7.

Table 4-7 10/100Base-TX Ethernet interface attributes

Attribute Description
Connector type RJ45
Ethernet_II

Supported Ethernet_SNAP
frame format IEEE 802.2
IEEE 802.3

10/100 Mbps autosensing


Operating
Full duplex
mode
Half-duplex
Supported
network IP
protocol

4) Attributes of the 10/100/1000M Ethernet interface are shown in Table 4-8.

Table 4-8 Attributes of the 10/100/1000M Ethernet interface

Attribute Description
Connector type SFP optical module
Number of
2 1
interfaces

Supported Ethernet_II
frame format Ethernet_SNAP

Huawei Technologies Proprietary

4-11
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Attribute Description
10M/100Mbps autosensing
Working mode
Full duplex
Supported
network IP
protocol

4.2.5 Technical Specifications

The technical specifications of the RPU board are shown in Table 4-9.

Table 4-9 Technical specifications of the RPU

Parameter Description
Silkscreen RPU

Power
35 W
consumption (W)

Dimensions (mm) 399.15 mm (W) x 236 mm (D) x 35.06 mm (H)


Height of the front
35.06 mm
panel

4.3 NPU

This section introduces the functions of Network Process Unit (NPU), the board and
the technical specifications of the NE20E.

The board is located in the back slot on the bottom of the case-shape cabinet. NPU
is inserted in the system from the back and corresponds with the RPU.

4.3.1 Functions

NPU consists of the network processor module, the FPGA module, the storage
module and the other attached devices. The board implements the expedited
forwarding of the data packet, including the IP forwarding, MPLS forwarding,
multicast forwarding and QoS. The forwarding rate can reach 6 Mpps.

NPU has the following functions:


z Inputs the service data convergence and outputs the service data division.
Provides the upstream and downstream of the data convergence module with
the QoS guarantee.

Huawei Technologies Proprietary

4-12
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

z Encapsulates and decapsulates the data frame after the data of HIC and FIC
enters the network process module. Encapsulates and decapsulates the data
frame after the high speed interface control packets enter the network process
module.
z Periodically detects the state of the network process module and queries the
board version.
z Updates the logical device of EPLD and FPGA and implements the online loop
and the offline loop of FPGA in the board.
z Monitors the temperature.
z Support the reset of the service interface board and other main modules.
z Supports the CABWatch debugging tool provided by the IBM.

4.3.2 Front Panel

The appearance of the board is shown in Figure 4-6.


R
AL
U

M
N

Figure 4-6 Appearance of NPU front panel

The description of indicators of NPU is shown in Table 4-10.

Table 4-10 Description of NPU indicators

Component Description
It indicates the running LED. Constant ON means NPU works
RUN (green) normally. Constant OFF means NPU is not in position or has
failed.

ALM (red) It indicates the alarm LED. Constant ON means NPU has fialed.

NPU does not provide the outward interface.

Huawei Technologies Proprietary

4-13
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

4.3.3 Technical Specifications

The NPU technical specifications are shown in Table 4-11.

Table 4-11 Descripiton of the NPU technical specifications

Parameter Description
Silkscreen NPU
Power
58 W
consumption (W)

Dimension (mm) 372.45 mm (W) x 238 mm (D) x 35.06 mm (H)


Height of the front
35.06 mm
panel

4.4 10/100Base-TX Electrical Interface Module

10/100Base-TX etelectrical interface modules of the NE20E series routers are as


follows:
z 2-port 10/10Base-TX Ethernet electrical Interface Module (2FE)
z 2-port 10/10Base-TX Fast Ethernet electrical Interface Module (RT-HIC-2FE)
z 4-port 10/10Base-TX Fast Ethernet electrical Interface Module (RT-HIC-4FE)
z 8-port 10/10Base -TX Fast Ethernet electrical Interface Module (RT-HIC-8FE)

4.4.1 Functions

10/100Base-TX Ethernet electrical interface module provides the Fast Ethernet (FE)
interface that is used to enable the connection between routers and the LAN.

4.4.2 Front Panel

The appearance of the 10/100Base-TX Ethernet electrical interface is shown in


Table 4-12.

Table 4-12 Description of the 10/100Base-TX Ethernet electrical interface module

Silkscreen Description

2FE

Huawei Technologies Proprietary

4-14
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Silkscreen Description

RT-HIC-2FE

RT-HIC-4FE

RT-HIC-8FE

The description of indicators of 10/100Base-TX Ethernet electrical interface module


are shown in Table 4-13.

Table 4-13 Description of indicators of the 10/100Base-TX Ethernet electrical


interface module

LED Description
OFF means the link is not connected and ON means the link is
LINK
connected.

OFF means no data is being transmitted/received on the interface and


ACT blinking means data is being transmitted/received. The high frequency
of blinking means the large data flow.

4.4.3 Interface Attributes

Attributes of 10/100Base-TX Ethernet electrical interface are shown in Table 4-14.

Table 4-14 Attributes of 10/100Base-TX Ethernet electrical interface module

Attribute Description
Connector type RJ45

Cable type Standard Ethernet cable

Transmission distance 100 m (with the Category 5 UTP cable)

Huawei Technologies Proprietary

4-15
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Attribute Description
Full duplex/Half-duplex
Operating mode
10M/100 Mbit/s auto-negotiation

Compliant standard IEEE 802.3u

Ethernet_II
Supported frame format
Ethernet_SNAP

Supported network protocol IP

4.5 100Base-FX Ethernet Optical Interface Module

100Base-FX Ethernet optical interface modules of NE20E series routers are shown
as follows:
z 1-port 100Base-FX Ethernet Multi-mode optical interface module (1MFX)
z 2-port 100Base-FX Ethernet signle/Multi-mode optical interface module
(RT-HIC-2FE-SFP)
z 4-port 100Base-FX Ethernet signle/Multi-mode optical interface module
(RT-HIC-4FE-SFP)
z 8-port 100Base-FX Ethernet signle/Multi-mode optical interface module
(RT-HIC-8FE-SFP)

4.5.1 Functions

100Base-FX Ethernet optical interface module provides the optical interface. The
optical interface enables the routers to communicate with the LAN based on the
quite high realiability and high transmission quality of the fiber.

4.5.2 Front Panel

The appearance of the 100Base-FX Ethernet optical interface module is shown in


Table 4-15.

Table 4-15 Description of the 100Base-FX Ethernet optical interface module

Silkscreen Description

1MFX

Huawei Technologies Proprietary

4-16
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Silkscreen Description

RT-HIC-2FE
-SFP

RT-HIC-4FE
-SFP

RT-HIC-8FE
-SFP

The description of the 100Base-FX Ethernet optical interface module is shown in


Table 4-16.

Table 4-16 Description of indicators of 100Base-FX Ethernet optical interface


module

Indicator State and implication


OFF means the link is not connected and ON means the link is
LINK
connected.
OFF means no data is being transmitted/received on the interface and
ACT
blinking means data is being transmitted/received.

4.5.3 Interface Attributes

100Base-FX Ethernet optical interface attributes are shown in Table 4-17. The SFP
optical module is configured separately and its attributes are shown in Table 4-18.

Table 4-17 Attributes of 100Base-FX Ethernet optical interface

Item Description
Duplex mode Full duplex
Rate 155 Mbit/s
Applicable standard IEEE 802.3u

Huawei Technologies Proprietary

4-17
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Item Description
Ethernet_II
Supported frame format
Ethernet_SNAP
Supported network protocol IP

Table 4-18 Attributes of 100Base-FX Ethernet interface SFP optical module

Description
100M single-mode
100M multi-mode optical
Item optical interface
interface module
module
100Base-FX
100Base-FX
Connector type SC

Transmitt Minimum -15 dBm -19 dBm


ing
power Maximum -8 dBm -14 dBm

Receiver sensitivity -28 dBm -30 dBm

Overload power -8 dBm -14 dBm


Sender type LD LED
Center wavelength 1310 nm 1310 nm

Maximum
15 km 2 km
transmission distance

4.6 1000Base-X Ethernet Optical Interface Module

1000Base-X Ethernet optical interface modules of NE20E are as follows:


z 1-port 1000Base-X Ethernet optical interface module (RT-HIC-1GE)
z 2-port 1000Base-X Ethernet optical interface module (RT-HIC-2GE)

4.6.1 Functions

1000Base-X Ethernet optical interface module provides the Gigabit Ethernet (GE)
optical interface that enables the communication between routers and the LAN.

4.6.2 Front Panel

The appearance of 1000Base-X Ethernet optical interface module is shown in Table


4-19.

Huawei Technologies Proprietary

4-18
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-19 Description of the 1000Base-X Ethernet optical interface module

Silkscreen Description

RT-HIC-1GE

RT-HIC-2GE

The description of indicators of 1000Base-X Ethernet optical interface module is


shown in Table 4-20.

Table 4-20 Description of indicators of 1000Base-X Ethernet optical interface


module

Indicator State and implication


OFF means the link is not connected and ON means the link is
LINK
connected.
OFF means no data is being transmitted/received on the interface and
ACT
blinking means data is being transmitted/received.

4.6.3 Interface Attributes

Attributes of 1000Base-X Ethernet electrical interface are shown in Table 4-21. The
SFP optical module is configured separately and its attributes are shown in Table
4-22.

Table 4-21 Attributes of 1000Base-X Ethernet interface module

Description
Item
2GE 1GE
Connector
LC
type

Interface
2 1
number

Duplex mode Full-duplex

Huawei Technologies Proprietary

4-19
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Description
Item
2GE 1GE
Rate 1.25 Gbit/s
Standard
IEEE 802.3z
compliance
Ethernet_II
Frame format
Ethernet_SNAP
Network
IP
protocol

Table 4-22 Attributes of SFP optical module of 1000Base-X Ethernet interface


module

Description

1000M 1000MS
1000M 1000M
Single-mode ingle-mode
Single-mod Multi-mode
long haul ultra long
e optical optical
Item optical haul optical
interface interface
interface interface
module module
module
1000Base-L 1000Base-S module
1000Base-L
X X 1000Base-LX X
Connector type LC LC LC LC
Minim
Transmitt -9.5 dBm -9.5 dBm -4 dBm -3 dBm
um
ing
power Maxim
-3 dBm -4dBm 1 dBm 2 dBm
um

Minim
Receiver -24 dBm -21 dBm -30 dBm -30 dBm
um
sensitivit
y Maxim
-20.5 dBm -18 dBm -21 dBm -23 dBm
um

Sender type LD LED LD LD


1550
Center wavelength 1310 nm 850 nm 1550 nm
nm/1310 nm

Maximum
transmission 10 km 500 m 40 km 70 km
distance

Huawei Technologies Proprietary

4-20
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

4.7 Channelized/Unchannelized E1/T1 Interface Module

The channelized E1/T1 interface modules of the NE20E are as follows:


z 4-port channelized E1 module (4CE1)
z 4-port unchannelized E1 module (4E1-F)
z 8-port channelized E1 module (8CE1)
z 8-port unchannelized E1 module (8E1)
z 4-port channelized T1 module (4CT1)
z 8-port channelized T1 module (8CT1)

4.7.1 Functions

Channelized/unchannelized E1/T1 interface module can transmit, receive and


process E1/T1 data flow. Channelized E1/T1 module offers the access to CE1/CT1
and implement the ISDN PRI function.

The functions are as follows:


z Supports the internal and external clocks.
z Supports the working modes of the remote, the local and the frame loops.
z Supports various link layer protocols, such as PPP, Frame Relay and HDLC.
The differences between the unchannelized E1 module and the channelized E1
module are as follows:
z The unchannelized module supports the working mode of once binding, that is,
binding.
z The unchannelized module does not support the PRI mode.
The primary differences between unchannelized E1 interface modules and
channelized E1 interface modules are as below:
z Unchannleized interface modules only support binding once. That is, multiple
unchannelized interface modules can be bound with one channel with speed of
2.048 Mbit/s. Channelized interface modules, however, support multiple
bindings. That is, 31 channels can be bound into several groups at will.
z Unchannelized interface modules do not support PRI mode.

4.7.2 Front Panel

Appearance of channelized/unchannelized E1/T1 interface module is shown in Table


4-23.

Huawei Technologies Proprietary

4-21
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-23 Description of channelized and unchannelized E1/T1 interface module

Silkscreen Description

4E1

4E1A

4E1B

4E1-F

4CE1A

4CE1B

4CT1

Huawei Technologies Proprietary

4-22
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Silkscreen Description

8CE1A

8CE1B

8E1A 8*E1-120ohm
LINK
LINK
ACT ACT
8E1A 8E1A

8E1B

8CT1

The description of indicators of channelized/unchannelized E1/T1 interface module


are shown in Table 4-24.

Table 4-24 Description of indicators of channelized/unchannelized E1/T1 interface


module

Indicator State and implication


If the indicator is on, the link is connected. If the indicator is off, the
LINK
link is disconnected.

If the indicator is off, there is no data being transmitted or received.


ACT If the indicator is flashing, there is data being transmitted or
received.
0-7: means the LEDs corresponding to the relevant port number.

Huawei Technologies Proprietary

4-23
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

4.7.3 Interface Attributes

Attributes of channelized/unchannelized E1/T1 interface module are shown in Table


4-25.

Table 4-25 Attributes of channelized/unchannelized E1/T1 interface module

Attribute Description
Connector type DB-68

75 coaxial cable
Line interface
120 shielded twisted pair cable

75
coaxial 500 m
cable
Maximum
transmit 120
distance shielded
twisted 150 m
pair
cable

ITU-T G.703
Interface standard
G.704

E1 mode: 2048 kbit/s


Working mode
CE1 mode: N x 64 kbit/s (N=1, 2, 331)

PPP
MP
Supported protocol
Frame Relay
MFR

4.8 Channelized E3 Interface Modules

The channelized E3 interface module only has one type at present, that is, the
1-port channelized E3 module (1cE3).

4.8.1 Functions

Channelized E3 interface modules support channelized E3 and unchannelized E3


operation modes. In channelized operating mode, the E1 channels can be
configured with time slot binding.

The channelized E3 interface module mainly accomplishes the following functions:

Huawei Technologies Proprietary

4-24
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

z In E3 operating mode, transmit and process E3 high speed data flows; provide
access to E3 data flows.
z In cE3 operating mode, provide N X 64 kbit/s (N=1, 2, , 31) low speed access
services.

Note:
E3 means the thrice primary rate (34.368 Mbit/s) of E series in the time division
multiplexing system. One channel of E3 can be channelized into 16 E1 through
twice demultiplexing processes: E23 (E2 to E3 multiplexing/E3 to E2 demultiplexing
process, here referred to the demultiplexing process) and E12 (E1 to E2
multiplexing/E2 to E1 demultiplexing process, here referred to the demultiplexing
process). Each E1 supports both E1 and cE1 operating modes.

4.8.2 Front Panel

Appearance of channelized E3 interface module is shown in Table 4-26.

Table 4-26 Description of channelized E3 interface module

Name Panel figure

1cE3

The description of indicators of channelized E3 interface module are shown in Table


4-27.

Table 4-27 Description of indicators of channelized E3 interface module

LED Description
OFF means the link is not connected and ON means the link is
LINK
connected.

OFF means no data is being transmitted/received on the interface and


ACT
blinking means data is being transmitted/received.

Huawei Technologies Proprietary

4-25
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

4.8.3 Interface Attributes

Attributes of channelized E3 interface module are shown in Table 4-28.

Table 4-28 Attributes of channelized E3 interface module

Description
Attribute
1cE3
Connector type SMB

Cable type 75-ohm coaxial cable

Operating mode E3, cE3, cE1


z E3 mode: 34.368 kbit/s
z cE3 mode: provides 16 E1 channels with the rate of
Interface rate 2.048 Mbit/s per E1 channel
z cE1 mode: N X 64 kbit/s (N=1, 2, , 31)
Max. transmit distance 0.1 km

Interface standard ITU-T G.703, G.704

Supported network
IP
protocol

PPP
Frame Relay
Supported protocol HDLC
MP
MFR

4.9 Synchronous Serial Port Module

There is only one kind of synchronous serial interface module, that is, 4-port
enhanced high-speed synchronous serial interface card (4SAE).

4.9.1 Functions

4SAE supports the synchronous working mode. Its main function is to receive, send
and process the synchronous serial data flow and to support the modes of Data
Terminal Equipments (DTE) and the Data Circuit-terminating Equipments (DCE).

The functions of the interface are as follows:


z Supports the local loopback.

Huawei Technologies Proprietary

4-26
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

z Automatically identifies the V.35 and V.24/X.21 cables.


z Supports various link layer protocols, such as PPP, Frame Relay and HDLC.

I. DTE and DCE

The 4SAE card is connected with a Modem and serves as a dialing port. In this case,
you need to set the appropriate baud rate.

The synchronous serial port can work in either DTE mode or DCE mode. Two
directly-connected devices work in DTE mode and DCE mode respectively. In this
case, the DCE device offers the synchronous clock and specifies the baud rate,
while the DTE device receives the synchronous clock and carries out
communication based on the specified baud rate.

Generically, the router serves as a DTE device. For the type (DCE or DTE) of the
device connected with the router, refer to the manual accompanying the device.

For the specified device types, you can see Table 4-29.

Table 4-29 Typical DTE and DCE devices

Device type Interface type Typical device


DTE Pin (male) PC and router

DCE Hole (female) Modem, multiplexer, and CSU/DSU

II. Synchronous Interface Rate and Transmission Distance

In different working modes, the synchronous serial port supports different electric
signal standards and baud rates. The set baud rate and the selected cable
determine the maximum transmission distance of the signal. For the relationship
between cable type, baud rate and maximum transmission distance of signals, see
Table 4-30.

Table 4-30 V.24/V.35 cable rate and transmission distance

V.24 V.35

Baud rate Maximum Baud rate Maximum


(bit/s) transmission distance (bit/s) transmission
(m) distance (m)
2400 60 2400 1250

4800 60 4800 625

9600 30 9600 312

19200 30 19200 156

Huawei Technologies Proprietary

4-27
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

V.24 V.35

Baud rate Maximum Baud rate Maximum


(bit/s) transmission distance (bit/s) transmission
(m) distance (m)
38400 20 38400 78

64000 20 56000 60

115200 10 64000 50

- - 2048000 30

Note:
If the V.24 cable is used, the SA baud rate cannot exceed 64 kbit/s.

4.9.2 Front Panel

Appearance of synchronous serial port module is shown in Table 4-31.

Table 4-31 Description of synchronous serial port module

Silkscrern Description

4SAE

The description of indicators of synchronous serial port module is shown in Table


4-32.

Table 4-32 Description of indicator of synchronous serial port module

Indicator State and implication


If the indicator is on, the link is connected. If the indicator is off, the
LINK
link is disconnected.
If the indicator is off, there is no data being transmitted or received.
ACT If the indicator is flashing, there is data being transmitted or
received.

Huawei Technologies Proprietary

4-28
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

4.9.3 Interface Attributes

Attributes of synchronous serial port is shown in Table 4-33.

Table 4-33 Attributes of 4SAE interface module

Attribute Description
Connector type DB-28

Interface standard and V.24 V.35, RS449, RS530, X.21


working mode DTE and DCE DTE DCE

Minimum baud rate


1200 1200
(bit/s)

Maximum baud rate


64 K 4.096M 2.048M
(bit/s)

V.24 DTE cable


V.24 DCE cable
V.35 DTE cable
V.35 DCE cable
X.21 DTE cable
Cable type
X.21 DCE cable
RS449 DTE cable
RS449 DCE cable
RS530 DTE cable
RS530 DCE cable

PPP
HDLC
Supported protocol Frame Relay
MFR
MP

Note:
If the synchronous serial port is connected with a converter, it can offer X.21,
EIA/TIA-449, or EIA-530 interface.

Huawei Technologies Proprietary

4-29
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

4.10 ATM 155M Optical Interface Module

ATM 155M optical interface modules of the NE20E are as follows:


z 1-port ATM 155M Multi-mode optical interface module (1ATM-OC3MM)
z 1-port ATM 155M Single-mode optical interface module (1ATM-OC3MM)
z 1-port ATM 155M Single-mode long haul optical interface module
(1ATM-OC3SML)

4.10.1 Functions

ATM 155M optical interface module provides the system with the ATM interface. The
functions of the interface are as follows:
z Supports the two frame formats, SDH and SONET.
z Allows scrambling in data transmission.
z Supports both line clock (used when working as DTE interface) and internal
clock (used when working as DCE interface).
z Supports the test measures of local cell loopback, local payload loopback and
remote loopback.
z Supports the hardware flow control and the software resetting.

4.10.2 Front Panel

Appearance of ATM 155M optical interface module is shown in Table 4-34.

Table 4-34 Description of the ATM 155M optical interface module

Silkscreen Description

1ATM-OC3
MM

1ATM-OC3
SM

1ATM-OC3
SML

Huawei Technologies Proprietary

4-30
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

The description of indicators of ATM 155M optical interface module is shown in


Table 4-35.

Table 4-35 Description of indicators of the front panel

Indicator State and implication


If the indicator is on, the link is connected. If the indicator is off, the
LINK
link is disconnected.
If the indicator is off, there is no data being transmitted or received.
ACT If the indicator is flashing, there is data being transmitted or
received.

4.10.3 Interface Attributes

Attributes of ATM 155M optical interface module are shown in Table 4-36. The SFP
optical module is separately configured in the interface module and its attributes are
shown in Table 4-37.

Table 4-36 Attributes of ATM 155M optical interface module

Attribute Description
Connector
SC
type

Interface
155 Mbit/s
rate

Interface
SONET/SDH
standard
ATM Traffic Constant Bit Rate (CBR)
Supported rt_Variable Bit Rate-Real Time (VBR)
services
type nrt_Variable Bit Rate-Non Real Time (VBR)
Unspecified Bit Rate (UBR)
IPoA

Supported IPoEoA
protocol PPPoA
PPPoEoA

Huawei Technologies Proprietary

4-31
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-37 Attributes of the optical module with the ATM 155M optical interface
module

Description

Item Multi-mode Single-mode Single-mode


optical optical optical interface
interface interface with long haul
Connector type SC SC SC

Transmitting Minimum -15 dBm -19 dBm -5 dBm


power Maximum -8 dBm -14 dBm 0 dBm

Minimum -28 dBm -30 dBm -34 dBm


Receiver
sensitivity
Maximum -8 dBm -14 dBm -10 dBm

Sender type LED LD LD


Wavelength 1310 nm
Maximum transmission
2 km 15 km 30 km
distance

4.11 ATM Over E3 Interface Module

The ATM over E3 interface module of the NE20E only has one type, that is, 1-port
ATM over E3 module (1AE3).

4.11.1 Functions

The functions of The ATM over E3 interface module in the system are as follows:
z Supports two ATM cell mapping modes: ATM Direct Mapping (ADM) and
Physical Layer Convergence Protocol (PLCP).
z Allows scrambling in data transmission.
z Supports both line clock (used when working as DTE interface) and internal
clock (used when working as DCE interface).
z Supports the test measures of local cell loopback, local payload loopback and
remote loop.

Huawei Technologies Proprietary

4-32
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Note:
It is recommended to install only one ATM over E3 interface module on each
Quidway router because multiple such interface modules may affect the
performances of some key services.

4.11.2 Front Panel

Appearance of ATM over E3 interface module is shown in Table 4-38.

Table 4-38 Description of ATM over E3 interface module

Silkscreen Description

1AE3

The description of indicators of ATM over E3 interface module is shown in Table


4-39.

Table 4-39 Description of indicators of the ATM over E3 interface module

Indicator State and implication


If the indicator is on, the link is connected. If the indicator is off, the
LINK
link is disconnected.
If the indicator is off, there is no data being transmitted or received.
ACT If the indicator is flashing, there is data being transmitted or
received.

4.11.3 Interface Attributes

Attributes of ATM over E3 interface module are shown in Table 4-40.

Table 4-40 Attributes of ATM over E3 interface module

Item Description
Connector
type SMB (34.368M electrical Interface)

Huawei Technologies Proprietary

4-33
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Item Description
Interface
75 coaxial cable
cable

Maximum
transmission 100 m
distance

Standard
ITU-T G.703
compliance

Rate 34.368 Mbit/s


IPoA

Supported IPoEoA
protocol PPPoA
PPPoEoA
Supported
CBR, UBR, nrt_VBR and rt_VBR
service type

4.12 Channelized or Unchannelized POS Optical Interface


Modules

The channelized/unchannelized POS optical interface modules of NE20E series


routers are as follows:
z 1-port channelized POS optical module (1CPOS(E))
z 1-port unchannelized POS/155M optical interface module (RT-HIC-1POS)
z 2-port unchannelized POS/155M optical interface module (RT-HIC-2POS)
z 4-port unchannelized POS/155M optical interface module (RT-HIC-4POS)

4.12.1 Functions

Packet over SDH (POS) interface is a high-speed transport interface which takes
the SONET/SDH network as the transport interface. In sending direction, the POS
interface encapsulates IP data packets received from the NP with the PPP protocol
or HDLC protocol, and then maps the encapsulated data packets to the payload of
the SONET/SDH frame for transmission on the optical network. In receiving
direction, the POS interface receives optical signals, processes them through
reverse operations, and then sends them to the NP.

The POS interface board can be used to connect NE20E routers and SONET/SDH
devices together, or connect NE20E routers directly.

Huawei Technologies Proprietary

4-34
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

One POS interface module can be channelized into E1 channels, and can provide
63 E1 channels or T1 channels.

The functions of interface are as follows:


z Supports the hardware flow control and the software resetting.
z Supports various link layer protocols, such as PPP, Frame Relay and HDLC.
z Supports the working modes of FPGA loopback, the system side loopback of
the physical chip and the line side loopback.

4.12.2 Front Panel

Appearance of channelized/unchannelized POS optical interface module is shown in


Table 4-41.

Table 4-41 Description of channelized/unchannelized POS optical interface module

Silkscreen Description

1CPOS(E)

RT-HIC-1P
OS

RT-HIC-2P
OS

RT-HIC-4P
OS

The description of indicators of channelized/unchannelized POS optical interface


module is shown in Table 4-42.

Huawei Technologies Proprietary

4-35
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-42 Description of indicators of the front panel

Indicator State and implication


If the indicator is on, the link is connected. If the indicator is off, the
LINK
link is disconnected.
If the indicator is off, there is no data being transmitted or received.
ACT If the indicator is flashing, there is data being transmitted or
received.

4.12.3 Interface Attributes

Attributes of channelized/unchannelized POS optical interface module is shown in


Table 4-43. SFP optical module is configured separately and its attributes are shown
in Table 4-44.

Table 4-43 Attributes of channelized/unchannelized POS optical interface module

Item Description
Rate 155 Mbit/s
Unchannelized: 155 Mbit/s and full-duplex
Operating mode
channelized: 63 E1 channels or 84 T1 channels
STM-1/OC-3c SONET/SDH
Applicable standard
IETF RFC1619/1661/1662

Supported network
IP
protocol
PPP
HDLC
Supported protocols
Frame Relay
MFR

Huawei Technologies Proprietary

4-36
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-44 Attributes of SFP optical module with the channelized/unchannelized


POS optical interface module

Description

Item Single-mo Single-mode


Multi-mo Single-mod
de shot super long
de e long haul
haul haul
Connector type LC

Transmitti Minimum -15 dBm -19 dBm -5 dBm -5 dBm


ng power Maximum -8 dBm -14 dBm 0 dBm 0 dBm

Minimum -28 dBm -30 dBm -34 dBm -34 dBm


Receiver
sensitivity
Maximum -8 dBm -14 dBm -10 dBm -10 dBm

Sender type LD LED LD LD


Wavelength 1310 nm 1550nm
Maximum transmission
15 km 2 km 40 km 80 km
distance

4.13 HSSI Interface Module

HSSI interface module of the NE20E series routers are shown as follows:
z 1-port HSSI interface (1HSSI)
z 2-port HSSI interface (2HSSI)

4.13.1 Functions

High Speed Serial Interface (HSSI) is connected by the HSSI cable. In the sending
direction, the IP data packet is PPP or HDLC encapsulated and sent to the HSSI
interface line after being transmitted into the ECL level serial data. In the receiving
direction, the serial ECL level data is transmitted into the TTL level and is processed
with the HDLC frame. Extract the IP data packet in the reverse process and forward
the IP data packet.

The NE20E with the HSSI interface can be connected to the DCE equipment
(CSU/DSU) as the DTE equipment or connected with the DTE equipment back to
back.

The functions of interface are as follows:

Huawei Technologies Proprietary

4-37
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

z The HSSI interface level is ECL. The highest rate is 52 Mbps and the farthest
transmission distance is 50 inches (15 m).
z Support two loop working modes, that is, the physical chip self-loop and the line
self-loop.
z The interface supports many link layer protocols, such as PPP and HDLC.
z Supports the auto-identification of DTE and DCE and chooses the clock
automatically.

4.13.2 Front Panel

Appearance of HSSI interface module is shown in Table 4-45.

Table 4-45 Description of the HSSI front panel

Silkscreen Description

1HSSI

2HSSI

The description of indicators of HSSI interface module is shown in Table 4-46.

Table 4-46 Description of indicators of the HSSI front panel

Indicator State and implication


If the indicator is on, the link is connected. If the indicator is off, the link
LINK
is disconnected.

If the indicator is off, there is no data being transmitted or received. If


ACT
the indicator is flashing, there is data being transmitted or received.

4.13.3 Interface Attributes

Attributes of HSSI interface module is shown in Table 4-47.

Huawei Technologies Proprietary

4-38
Hardware Description
Quidway NetEngine20E Series Routers Chapter 4 Board

Table 4-47 Attributes of HSSI interface module

Item Description
Type HSSI electrical interface
Rate 52 Mbit/s
Working mode Unchannelized: 51.84M
Standard
Compliant with STS-1
compliance

Supported
IP
network protocol

Supported link PPP


layer protocols HDLC

Huawei Technologies Proprietary

4-39
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Chapter 5 Cable ............................................................................................................................. 5-1


5.1 DC Power Cable ................................................................................................................ 5-2
5.1.1 Introduction.............................................................................................................. 5-2
5.1.2 Structure.................................................................................................................. 5-2
5.2 AC Power Cable ................................................................................................................ 5-3
5.2.1 Introduction.............................................................................................................. 5-3
5.2.2 Structure.................................................................................................................. 5-3
5.3 Console Port Cable............................................................................................................ 5-3
5.3.1 Introduction.............................................................................................................. 5-3
5.3.2 Structure.................................................................................................................. 5-3
5.4 Auxiliary Port Communication Cable ................................................................................. 5-4
5.4.1 Introduction.............................................................................................................. 5-4
5.4.2 Structure.................................................................................................................. 5-5
5.5 Ethernet Cable ................................................................................................................... 5-5
5.5.1 Introduction.............................................................................................................. 5-5
5.5.2 Structure.................................................................................................................. 5-6
5.6 Optical Fiber....................................................................................................................... 5-7
5.6.1 Introduction.............................................................................................................. 5-7
5.6.2 Optical Connector ................................................................................................... 5-8
5.7 Channelized/Unchannelized E1/T1 Interface Cable.......................................................... 5-9
5.7.1 4E1-F/4CE1 Interface Cable ................................................................................... 5-9
5.7.2 8E1-F/8CE1 Interface Cable ................................................................................. 5-13
5.7.3 4CT1/8CT1 Interface Cable .................................................................................. 5-18
5.8 Channelized E3 Interface Cable ...................................................................................... 5-19
5.8.1 Introduction............................................................................................................ 5-19
5.8.2 Structure................................................................................................................ 5-19
5.9 Synchronous Serial Interface Cable ................................................................................ 5-19
5.9.1 Introduction............................................................................................................ 5-19
5.9.2 Structure................................................................................................................ 5-20
5.10 ATM over E3 Interface Cable ........................................................................................ 5-30
5.10.1 Introduction.......................................................................................................... 5-30
5.10.2 Structure.............................................................................................................. 5-30
5.11 HSSI Cable .................................................................................................................... 5-31
5.11.1 Introduction.......................................................................................................... 5-31
5.11.2 Structure.............................................................................................................. 5-31

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Chapter 5 Cable

This chapter introduces the types, the structure and technical parameters of the
external cable used by the NE20E.

The external cables and their usage are shown in Table 5-1.

Table 5-1 List of the external cable

Name Usage Remark


DC power Used to import the DC-input power
Refer to DC Power Cable.
cable to the NE20E equipment.

AC power Used to import the AC-input power


Refer to AC Power Cable.
cable to the NE20E equipment.

Used to connect the console port


Refer to Console Port
Console cable to forward data and to implement
Cable.
local configuration.

Auxiliary port Used to connect the Modem to


Refer to Auxiliary Port
communication forward the signal and implement
Communication Cable.
cable remote maintenance.
Ethernet cable Used to forward the data signal. Refer to Ethernet Cable.

Used to connect the interface


board to the Optical Distribution
Optical fiber Frame (ODF) and also used to Refer to Optical Fiber.
connect the interface board to the
interface of other equipment.

Channelized/U
Used to connect Refer to
nchannelized
channelized/unchannelized E1/T1 Channelized/Unchannelize
E1/T1 interface
interface to the related equipment. d E1/T1 Interface Cable.
cable

Synchronous
Used to connect the serial interface Refer to Synchronous
serial interface
to the related equipment. Serial Interface Cable.
cable

ATM over E3 Used to connect AE3 interface to Refer to ATM over E3


interface cable the related equipment Interface Cable.

HSSI interface Used to connect the HSSI interface


Refer to HSSI Cable
cable to the related equipment.

Huawei Technologies Proprietary

5-1
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

5.1 DC Power Cable

5.1.1 Introduction

Direct Current (DC) power input range is from 36 V DC to 72 V DC.

The DC power cable contains the 48 V power cable NEG (), the power grounding
cable RTN (+) and the power protection grounding cable PGND. The power cable
transfers the 48 V DC power from the DC distribution equipment to the terminal
block of the NE20E power module, supplying power for the NE20E equipment.

Note:
The PGND cable of the power does not need to be connected. But the protection
grounding cable located on the back of the power module needs to be well
connected with the protection grounding cable of the chassis.

5.1.2 Structure

The wiring terminal of the NE20E power module is the OT bare pressure terminal.
The outline of DC power cable is shown in Figure 5-1.

1 Main label 2

1. Ordinary terminal-single line core end terminal-6 mm^2-0.02 m-30A-deep inserting 12


mm-black
2. Naked terminal-OT-6 mm^2-M4-tin electroplating-round pre-insulated terminal-12 AWG to
10 AWG-yellow
3. Electronic electrical power cable-600 V-UL3386-5.2 mm^2-10AWG-black-48 A-slight
smoke fireproof cable

Figure 5-1 DC power cable

Huawei Technologies Proprietary

5-2
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

5.2 AC Power Cable

5.2.1 Introduction

Alternating Current (AC) power cable ranges from 85 V AC to 264 V AC and 50/60
Hz.

The power cable transmits the AC to the terminal block of the NE20E power module
to supply power to the whole NE20E.

It is recommended to use the grounding single-phrase three-line power supply. The


grounding point of the power supply in the building must be reliable grounding. The
power grounding cable of the power supplying system is buried in the ground during
the construction of the building. Users must identify that the power supplies have
been grounding before connecting the AD power cable of the NE20E series routers.

5.2.2 Structure

The NE20E AC power cable includes not only Chinese standard AC power cable but
also the local-standard cable in Europe, North America and UK.

5.3 Console Port Cable

5.3.1 Introduction

The console cable is used to connect the NE20E console port to the serial port of
the console device for transmitting configuration data of the equipment.

The console cable is an 8-core shielded cable. One end uses the RJ45 connector
that is connected to the console port of the MPU. The other end has two connectors
with DB9 female and DB25 female respectively, and is connected with the serial port
of the computer. You can choose one of them to plug into the computer serial port
according to the actual condition.

5.3.2 Structure

The console port cable is shown in Figure 5-2.

Huawei Technologies Proprietary

5-3
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Enla rge d A side


Pos. 25

D B 25 Fe male
8 P8C PLU G

Enla rge d B side

A B

Pos.1 Pos.8

DB9 Fe male
Enlar ged C side
Pos.1

Pos.1 C

Pos.9

Figure 5-2 Console port cable

The pin assignments of the console port cables are shown in Table 5-2.

Table 5-2 The pin assignments of the console cable

RJ45 Signal Direction DB25 DB9 Signal


1 5 8 CTS
2 6 6 DSR
3 3 2 RXD
4 8 1 DCD
5 - 7 5 GND
6 2 3 TXD
7 20 4 DTR
8 4 7 RTS

5.4 Auxiliary Port Communication Cable

5.4.1 Introduction

The auxiliary (AUX) port cable is used to connect the NE20E AUX port to the
Modem for remote transmission of configuration data.

The AUX port cable is an 8-core shielded cable. One end uses the RJ45 connector
that is connected to the AUX port of the RPU. The other end has two connectors

Huawei Technologies Proprietary

5-4
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

with the DB9 (female) and DB25 (female) respectively, and is connected with the
computer serial port. You can choose one of them to plug into the computer serial
port according to the actual condition.

5.4.2 Structure

As shown in Figure 5-2, the structure of the AUX cable is the same as that of the
console cable. The pin assignments of the AUX cables are shown in Table 5-3.

Table 5-3 The pin assignments of the AUX cables

RJ45 Signal Direction DB25 DB9 Signal


1 4 7 RTS

2 20 4 DTR
3 2 3 TXD
4 8 1 DCD
5 - 7 5 GND
6 3 2 RXD
7 6 6 DSR
8 5 8 CTS

5.5 Ethernet Cable

5.5.1 Introduction

The Ethernet cable contains two types: the straight-through cable and the crossover
cable. All are 3 m long.

I. Straight-through Cable

Straight through cable is also called standard cable. The wire sequences of the
twisted pairs crimped in the RJ45 connectors at both ends are the same. It is used
for connecting a terminal device (PC or the router) to a HUB or a LAN Switch. The
cables delivered with the equipment are straight-through cables.

II. Crossover Cable

Crossover cable is also called direct connection cable. The wire sequences of the
twisted pairs crimped in the RJ45 connectors at both ends are different. It is used for
connecting two terminal devices (PC or the router).

Huawei Technologies Proprietary

5-5
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

5.5.2 Structure

Both straight-through cable and the crossover cable adopt shield cables and RJ45
connectors. The pin assignments are shown in Figure 5-3 and Figure 5-4.

RJ45 RJ45
1 1
2 2

3 3
6 6

Figure 5-3 Schematic diagram of the straight-through cable

RJ45 RJ45
1 1
2 2

3 3
6 6

Figure 5-4 Schematic diagram of crossover cable

The pin assignments of straight-through cable and crossover cable are respectively
shown in Table 5-4 and Table 5-5.

Table 5-4 The pin assignments of straight-through cable

RJ45 Signal Category 5 Twisted Pair Signal Direction RJ45


1 TX+ White (Orange) 1

2 TX- Orange 2

3 RX+ White (Green) 3

4 - Blue - 4

5 - White (Blue) - 5

6 RX- Green 6

7 - White (Brown) - 7

8 - Brown - 8

Huawei Technologies Proprietary

5-6
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Table 5-5 The pin assignments of the crossover cable

RJ45 Signal Category 5 Twisted Pair Signal Direction RJ45


1 TX+ White (Orange) 3

2 TX- Orange 6

3 RX+ White (Green) 1

4 - Blue - 4

5 - White (Blue) - 5

6 RX- Green 2

7 - White (Brown) - 7

8 - Brown - 8

Note:
Refer to the above table to differentiate and produce two Ethernet cables. Arrange
the line order according to the above chromatogram strictly, or the communication
quality can be affected though the two ends are well connected.

5.6 Optical Fiber

5.6.1 Introduction

NE20E uses the SFP optical module on different optical interface. The
corresponding optical fiber is shown as Table 5-6.

Table 5-6 Relationship between the interface type and corresponding optical fiber

Fiber
Optical
Interface type transmission Length
Connectors
mode
ATM 155M Single-mode/multi
SC/PC 5 m, 10 m, 20 m
optical interface -mode

Ethernet optical Single-mode/multi


SC/PC 5 m, 10 m, 20 m
interface -mode

Gigabit Ethernet Single-mode/multi


LC/PC 5 m, 10 m, 20 m
interface -mode

POS optical Single-mode/multi


LC/PC 5 m, 10 m, 20 m
interface -mode

Huawei Technologies Proprietary

5-7
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

SFP is in plug-in type. Both multi-mode module and single-mode module can be
plugged on the interface board. Different optical modules and optical connectors
need different fiber. The multi-mode interface module connects with the multi-mode
fiber; the single-mode module connects with the singlemode fiber.

The interfaces of ATM 155M and Ethernet optical module is equipped with SC
optical connector as shown in Figure 5-5. Therefore, you are recommended to use
the fiber with SC/PC optical connector. In addition, the optical interfaces of Gigabit
Ethernet optical interface module and POS optical interface module should apply LC
optical connector as shown in Figure 5-6. Therefore, you are recommended to use
the fiber LC/PC with optical connector.

5.6.2 Optical Connector

The NE20E uses two types of optical connectors:


SC/PC optical connector
LC/PC optical connector
The following contents describe their outlines, operations, and precautions of
plugging and unplugging connector.

The outline of the SC/PC optical connector is shown in Figure 5-5.

Figure 5-5 SC/PC optical connector

The outline of the LC/PC optical connectors is shown in Figure 5-6.

Huawei Technologies Proprietary

5-8
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Figure 5-6 LC/PC optical connector

The plugging or unplugging of LC/PC and SC/PC optical connectors only needs
axial operation instead of rotation. The operation procedures and precautions are as
follows:
When plugging the fiber connector, you should be careful to align the fiber head
with the optical interface, and push in the fiber with proper force.
When pulling the fiber out, you should press the clip first, and then pull the fiber
connector slightly and then plug out the connector.

5.7 Channelized/Unchannelized E1/T1 Interface Cable

5.7.1 4E1-F/4CE1 Interface Cable

The NE20E offers two kinds of 4-port interface cables as shown in Figure 5-7 and
Figure 5-8, that is, 4-port E1-F/cE1 coaxial cable and 4-port E1-F/cE1 shielded
twisted pair cable respectively for 75 unshielded interface module and 120
shielded interface module. E1 cable and cE1 cable are completely compatible.

Huawei Technologies Proprietary

5-9
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

L ab e l 8

L ab e l 7

L ab e l 6

L ab e l 5

L ab e l 4

L ab e l 3

L ab e l 2

L ab e l 1

Figure 5-7 75-ohm 4E1-F/4CE1 coaxial cable

Pos.1 Pos.68

HPDB 68 male

P0

Dark blue*4

RJ45 connector

Metal shell

X1 X2 X3 X4

Pos.1 Pos.8

Figure 5-8 120-ohm 4E1-F/4CE1 shielded twisted pair cable

The pin assignments of 4E1/4CE1 cables are shown in Table 5-7 and Table 5-8.

Huawei Technologies Proprietary

5-10
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Table 5-7 The pin assignments of 4E1-F/4cE1 coaxial cable

DB68 Signal Direction BNC


1 AGND - -

2 AGND - -
3 TxTip3 NO.4 transmits
4 TxRing3 NO.4 transmits

5 AGND - -

6 AGND - -

10 - - -
11 TxTip2 NO.3 transmits
12 TxRing2 NO.3 transmits

13 AGND - -

14 AGND - -
19 TxTip1 NO.2 transmits
20 TxRing1 NO.2 transmits

21 AGND - -

22 AGND - -
27 TxTip0 NO.1 transmits

28 TxRing0 NO.1 transmits

29 AGND - -

30 AGND - -

35 AGND - -

36 RxShield3 - -
37 RxTip3 NO.4 receives
38 RxRing3 NO.4 receives

43 AGND - -

44 RxShield2 - -
45 RxTip2 NO.3 receives
46 RxRing2 NO.3 receives

51 AGND - -

52 RxShield1 - -
53 RxTip1 NO.2 receives

Huawei Technologies Proprietary

5-11
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

DB68 Signal Direction BNC


54 RxRing1 NO.2 receives

55 AGND - -

59 AGND - -

60 RxShield0 - -
61 RxTip0 NO.1 receives
62 RxRing0 NO.1 receives

67 AGND - -

68 AGND - -

Table 5-8 The pine assignments of 4E1-F/4cE1 shielded twisted pair cable

DB68 Signal Direction Signal RJ45

1 AGND - - -

2 AGND - - -

3 TxTip3 RxTip3 4

4 TxRing3 RxRing3 5

36 RxShield3 TxShield3 3

37 RxTip3 TxTip3 1

38 RxRing3 TxRing3 2

7 TxShield3 RxShield3 6

5 AGND - - -

6 AGND - - -

11 TxTip2 RxTip2 4

12 TxRing2 RxRing2 5

44 RxShield2 TxShield2 3

45 RxTip2 TxTip2 1

46 RxRing2 TxRing2 2

15 TxShield2 RxShield2 6

13 AGND - - -

14 AGND - - -

19 TxTip1 RxTip1 4

Huawei Technologies Proprietary

5-12
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

DB68 Signal Direction Signal RJ45


20 TxRing1 RxRing1 5

52 RxShield1 TxShield1 3

53 RxTip1 TxTip1 1

54 RxRing1 TxRing1 2

23 TxShield1 RxShield1 6

21 AGND - - -

22 AGND - - -

26 TxShield0 RxShield0 6

27 TxTip0 RxTip0 4

28 TxRing0 RxRing0 5

60 RxShield0 TxShield0 3

61 RxTip0 TxTip0 1

62 RxRing0 TxRing0 2

30 AGND - - -

35 AGND - - -

43 AGND - - -

51 AGND - - -

59 AGND - - -

67 AGND - - -

68 AGND - - -

5.7.2 8E1-F/8CE1 Interface Cable

The NE20E offers two kinds of 8-port interface cables as shown in Figure 5-9 and
Figure 5-10. They are the 8-port E1-F/CE1 coaxial cable and the 8-port E1-F/CE1
shielded twisted pair cable. And they are matchable with the 75 unshielded
interface module and the 120 shielded interface module respectively. E1 and CE1
cable are compatible.

Huawei Technologies Proprietary

5-13
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Injection component, Huawei blue 01

Back Side Logo A direction


Main lable

Figure 5-9 75-ohm 8E1-F/8cE1 coaxial cable

A direction

HUAWEI
Back Side Logo
Main label
Quidway

Figure 5-10 120-ohm 8E1-F/8cE1 shielded twisted pair cable

The pin assignments of 8E1/8CE1 cables are shown in Table 5-9 and Table 5-10.

Table 5-9 The pin assignments of 8E1/8CE1 coaxial cable

DB68 Signal Direction Signal BNC


1 DGND - - -

2 DGND - - -

47 CAB_ID0 - - -

Huawei Technologies Proprietary

5-14
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

DB68 Signal Direction Signal BNC

55 CAB_ID1 PIN68 DGND -

63 CAB_ID2 PIN67 DGND -

3 TxTip3 TxTip3 NO.4 transmits

4 TxRing3 TxRing3 NO.4 transmits

37 RxTip3 RxTip3 NO.4 receives

38 RxRing3 RxRing3 NO.4 receives

5 PGND - - -

6 PGND - - -

11 TxTip2 TxTip2 NO.3 transmits

12 TxRing2 TxRing2 NO.3 transmits

45 RxTip2 RxTip2 NO.3 receives

46 RxRing2 RxRing2 NO.3 receives

13 PGND - - -

14 PGND - - -

19 TxTip1 TxTip1 NO.2 transmits

20 TxRing1 TxRing1 NO.2 transmits

53 RxTip1 RxTip1 NO.2 receives

54 RxRing1 RxRing1 NO.2 receives

21 PGND - - -

22 PGND - - -

27 TxTip0 TxTip0 NO.1 transmits

28 TxRing0 TxRing0 NO.1 transmits

61 RxTip0 RxTip0 NO.1 receives

62 RxRing0 RxRing0 NO.1 receives

30 PGND - - -

29 PGND - - -

9 TxTip7 TxTip7 NO.8 transmits

10 TxRing7 TxRing7 NO.8 transmits

41 RxTip7 RxTip7 NO.8 receives

42 RxRing7 RxRing7 NO.8 receives

17 TxTip6 TxTip6 NO.7 transmits

Huawei Technologies Proprietary

5-15
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

DB68 Signal Direction Signal BNC


18 TxRing6 TxRing6 NO.7 transmits

49 RxTip6 RxTip6 NO.7 receives

50 RxRing6 RxRing6 NO.7 receives

25 TxTip5 TxTip5 NO.6 transmits

26 TxRing5 TxRing5 NO.6 transmits

57 RxTip5 RxTip5 NO.6 receives

58 RxRing5 RxRing5 NO.6 receives

33 TxTip4 TxTip4 NO.5 transmits

34 TxRing4 TxRing4 NO.5 transmits

65 RxTip4 RxTip4 NO.5 receives

66 RxRing4 RxRing4 NO.5 receives

35 PGND - - -

39 PGND - - -

43 PGND - - -

51 PGND - - -

59 PGND - - -

67 DGND - - -

68 DGND - - -

Table 5-10 The pin assignments of 8E1-F/8cE1/8cT1 shielded twisted pair cable

DB68 Signal Direction Signal RJ45


1 DGND - - -

2 DGND - - -

47 CAB_ID0 PIN1 DGND -

55 CAB_ID1 PIN68 DGND -

63 CAB_ID2 PIN67 DGND -

3 TxTip3 TxTip3 4

4 TxRing3 TxRing3 5

7 TxShield3 TxShield3 6

36 RxShield3 RxShield3 3

37 RxTip3 RxTip3 1

Huawei Technologies Proprietary

5-16
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

DB68 Signal Direction Signal RJ45


38 RxRing3 RxRing3 2

5 PGND - - -

6 PGND - - -

11 TxTip2 TxTip2 4

12 TxRing2 TxRing2 5

15 TxShield2 TxShield2 6

44 RxShield2 RxShield2 3

45 RxTip2 RxTip2 1

46 RxRing2 RxRing2 2

13 PGND - - -

14 PGND - - -

19 TxTip1 TxTip1 4

20 TxRing1 TxRing1 5

23 TxShield1 TxShield1 6

52 RxShield1 RxShield1 3

53 RxTip1 RxTip1 1

54 RxRing1 RxRing1 2

21 PGND - - -

22 PGND - - -

27 TxTip0 TxTip0 4

28 TxRing0 TxRing0 5

31 TxShield0 TxShield0 6

60 RxShield0 RxShield0 3

61 RxTip0 RxTip0 1

62 RxRing0 RxRing0 2

30 PGND - - -

29 PGND - - -

9 TxTip7 TxTip7 4

10 TxRing7 TxRing7 5

8 TxShield7 TxShield7 6

40 RxShield7 RxShield7 3

Huawei Technologies Proprietary

5-17
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

DB68 Signal Direction Signal RJ45


41 RxTip7 RxTip7 1

42 RxRing7 RxRing7 2

17 TxTip6 TxTip6 4

18 TxRing6 TxRing6 5

16 TxShield6 TxShield6 6

48 RxShield6 RxShield6 3

49 RxTip6 RxTip6 1

50 RxRing6 RxRing6 2

25 TxTip5 TxTip5 4

26 TxRing5 TxRing5 5

24 TxShield5 TxShield5 6

56 RxShield5 RxShield5 3

57 RxTip5 RxTip5 1

58 RxRing5 RxRing5 2

33 TxTip4 TxTip4 4

34 TxRing4 TxRing4 5

32 TxShield4 TxShield4 6

64 RxShield4 RxShield4 3

65 RxTip4 RxTip4 1

66 RxRing4 RxRing4 2

35 PGND - - -

39 PGND - - -

43 PGND - - -

51 PGND - - -

59 PGND - - -

67 DGND - - -

68 DGND - - -

5.7.3 4CT1/8CT1 Interface Cable

CT1 interface module of NE20E applies the 100 shielded twisted pair cable.

Huawei Technologies Proprietary

5-18
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

4CT1cable outline is shown in Figure 5-8. The pin assignments are shown in Table
5-8. 8CT1cable outline is shown in Figure 5-10. The pin assignments are shown in
Table 5-10.

5.8 Channelized E3 Interface Cable

5.8.1 Introduction

1cE3 interface module provide two SMB interfaces which are respectively
connected to the Tx end and Rx end of the peer device. The interfaces work in
75-ohm unbalanced transfer mode and are connected with the peer device through
a pair of 75-ohm unbalanced coaxial cables.

5.8.2 Structure

The outline of 1cE3 interface cable is shown in Figure 5-11.

BNC connector SMB connector

Figure 5-11 E3 interface cable

5.9 Synchronous Serial Interface Cable

5.9.1 Introduction

Every 4SAE interface is 28-core connectors. One end is DB28 connector to connect
with the router and the other end differs according to the network segment. Both are
3 m long.

The synchronous serial port cable contains the following types:


V.24 (EIA/TIA-232 DTE cable: DB-25 (male) plug at the network end
V.24 (EIA/TIA-232) DCE cable: DB-25 (female) receptacle at the network end
V.35 DTE cable: 34PIN (male) plug at the network end
V.35 DCE cable: 34PIN (female) receptacle at the network end
X.21 DTE cable: DB15 (male) plug at the network end
X.21 DCE cable: DB15 (female) receptacle at the network end
RS449 DTE cable: DB-37 (male) plug at the network end

Huawei Technologies Proprietary

5-19
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

RS449 DCE cable: DB37 (female) receptacle at the network end


RS530 DTE cable: DB-25 (male) plug at the network end
RS530 DCE cable: DB25 (female) receptacle at the network end

5.9.2 Structure

The outline of the synchronous serial port cable is shown as follows:


V.24 DTE cable

Figure 5-12 V.24 DTE cable

V.24 DCE cable

Figure 5-13 V.24 DCE cable

V.35 DTE cable

Figure 5-14 V.35 DTE cable

V.35 DCE cable

Huawei Technologies Proprietary

5-20
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Figure 5-15 V.35 DCE cable

X.21 DTE cable

Figure 5-16 X.21 DTE cable

X.21 DCE cable

Figure 5-17 X.21 DCE cable

RS449 DTE cable

Figure 5-18 RS449 DTE cable

RS449 DCE cable

Huawei Technologies Proprietary

5-21
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Figure 5-19 RS449 DCE cable

RS530 DTE cable

Figure 5-20 RS530 DTE cable

RS530 DCE cable

Figure 5-21 RS530 DCE cable

The pin assignments of synchronous serial port cables are as follows:

Table 5-11 The pin assignments of the V.24 DTE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
1 TxD+ 2 TxD
19 RxD+ 3 RxD

Huawei Technologies Proprietary

5-22
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Signal
DB-28 Signal DB-25 Signal
Direction
13 RTS+ 4 RTS
23 CTS+ 5 CTS

27 DTR+ 20 DTR
25 DSR+ 6 DSR
17 RxC+ 17 RxC

3 TxC+ 15 TxC
15 TxCE+ 24 ETC
11 DCD+ 8 DCD

22 LL 18 LIST

Table 5-12 The pin assignments of the V.24 DCE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
19 RxD+ 2 TxD

1 TxD+ 3 RxD
23 CTS+ 4 RTS
13 RTS+ 5 CTS

25 DSR+ 20 DTR
27 DTR+ 6 DSR
15 TxCE+ 17 RxC
3 TxC+ 15 TxC
17 RxC+ 24 ETC
11 DCD+ 8 DCD
22 LL 18 LIST

Table 5-13 The pin assignments of the V.35 DTE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - A Circuit GND

Huawei Technologies Proprietary

5-23
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Signal
DB-28 Signal DB-25 Signal
Direction
21 GND - B Shield GND
1 TxD+ P SD+
2 TxD- S SD-
19 RxD+ R RD+

20 RxD- T RD-

Table 5-14 The pin assignments of the V.35 DCE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - A Circuit GND
21 GND - B Shield GND
19 RxD+ P TxD+
20 RxD- S TxD-
1 TxD+ R RxD+

2 TxD- T RxD-
23 CTS+ C RTS
13 RTS+ D CTS
25 DSR+ H DTR
27 DTR+ E DSR
15 TxCE+ V SCR+
16 TxCE+ X SCR-
3 TxC+ Y SCT+
4 TxC+ AA SCT-
17 RxC+ U SCTE+
18 RxC- W SCTE-
11 DCD+ F RLSD
22 LL J LL

Huawei Technologies Proprietary

5-24
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Table 5-15 The pin assignments of the X.21 DTE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 8 Circuit GND
21 GND - 1 Shield GND

13 RTS+ 3 Control+
14 RTS- 10 Control-
23 CTS+ 5 Indication+
24 CTS- 12 Indication -
19 RxD+ 4 Receiver+
20 RxD- 11 Receiver-
1 TxD+ 2 Transmit+
2 TxD- 9 Transmit-
17 RxC+ 6 Timing+
18 RxC- 13 Timing-

Table 5-16 The pin assignments of the X.21 DCE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 8 Circuit GND
21 GND - 1 Shield GND

13 RTS+ 5 Indication+
14 RTS- 12 Indication -
23 CTS+ 3 Control+

24 CTS- 10 Control-
19 RxD+ 2 Transmit+
20 RxD- 9 Transmit-

1 TxD+ 4 Receiver+
2 TxD- 11 Receiver-
15 TxCE+ 6 Timing+

16 TxCE- 13 Timing-

Huawei Technologies Proprietary

5-25
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Table 5-17 The pin assignments of the RS499 DTE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 19 Circuit GND
21 GND - 1 Shield GND

27 DTR+ 12 TR+
28 DTR- 30 TR -
25 DSR+ 11 DM+
26 DSR- 29 DM-
13 RTS+ 7 RS+
14 RTS- 25 RS-
23 CTS+ 9 CS+
24 CTS- 27 CS-
11 DCD+ 13 RR+
12 DCD- 31 RR-
22 LL/LL 10 LL
19 RxD+ 6 RD+

20 RxD- 24 RD-
1 TxD+ 4 SD+
2 TxD- 22 SD-
15 TxCE+ 17 TT+
16 TxCE- 35 TT-
17 RxC+ 8 RT+
18 RxC- 26 RT-
3 TxC+ 5 ST+
4 TxC- 23 ST-

Table 5-18 The pin assignments of the RS499 DCE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 19 Circuit GND
21 GND - 1 Shield GND
27 DTR+ 11 DM+

Huawei Technologies Proprietary

5-26
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Signal
DB-28 Signal DB-25 Signal
Direction
28 DTR- 29 DM-
25 DSR+ 12 TR+
26 DSR- 30 TR -
13 RTS+ 9 CS+

14 RTS- 27 CS-
23 CTS+ 7 RS+
24 CTS- 25 RS-

11 DCD/DCD+ 13 RR+
12 DCD/DCD- 31 RR-
22 LL/LL 10 LL

19 RxD+ 4 SD+
20 RxD- 22 SD-
1 TxD+ 6 RD+
2 TxD- 24 RD-
15 TxCE+ 8 RT+
16 TxCE- 26 RT-
17 RxC+ 17 TT+
18 RxC- 35 TT-
3 TxC+ 5 ST+
4 TxC- 23 ST-

Table 5-19 The pin assignments of the RS530 DTE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
27 DTR+ 20 DTR+
28 DTR- 23 DTR-
25 DSR+ 6 DSR+
26 DSR- 22 DSR -
13 RTS+ 4 RTS+

Huawei Technologies Proprietary

5-27
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Signal
DB-28 Signal DB-25 Signal
Direction
14 RTS- 19 RTS-
23 CTS+ 5 CTS+
24 CTS- 13 CTS-
11 DCD/DCD+ 8 DCD+

12 DCD/DCD- 10 DCD-
22 LL/LL 18 LL
19 RxD+ 3 RxD+

20 RxD- 16 RxD-
1 TxD+ 2 TxD+
2 TxD- 14 TxD-

15 TxCE+ 24 TxCE+
16 TxCE- 11 TxCE-
17 RxC+ 17 RxC+
18 RxC- 9 RxC-
3 TxC+ 15 TxC+
4 TxC- 12 TxC-

Table 5-20 The pin assignments of the S530 DCE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
25 DSR+ 20 DTR+
26 DSR- 23 DTR-
27 DTR+ 6 DSR+
28 DTR- 22 DSR -
23 CTS+ 4 RTS+
24 CTS- 19 RTS-
13 RTS+ 5 CTS+
14 RTS- 13 CTS-
11 DCD/DCD+ 8 DCD+

Huawei Technologies Proprietary

5-28
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Signal
DB-28 Signal DB-25 Signal
Direction
12 DCD/DCD- 10 DCD-
22 LL/LL 18 LL
1 TxD+ 3 RxD+
2 TxD- 16 RxD-

19 RxD+ 2 TxD+
20 RxD- 14 TxD-
17 RxC+ 24 TxCE+

18 RxC- 11 TxCE-
15 TxCE+ 17 RxC+
16 TxCE- 9 RxC-

3 TxC+ 15 TxC+
4 TxC- 12 TxC-

Table 5-21 The pin assignments of RS530 DCE cable

Signal
DB-28 Signal DB-25 Signal
Direction
6 GND - 7 Circuit GND
21 GND - 1 Shield GND
25 DSR+ 20 DTR+
26 DSR- 23 DTR-
27 DTR+ 6 DSR+
28 DTR- 22 DSR -
23 CTS+ 4 RTS+
24 CTS- 19 RTS-
13 RTS+ 5 CTS+
14 RTS- 13 CTS-
11 DCD/DCD+ 8 DCD+
12 DCD/DCD- 10 DCD-
22 LL/LL 18 LL
1 TxD+ 3 RxD+
2 TxD- 16 RxD-

Huawei Technologies Proprietary

5-29
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Signal
DB-28 Signal DB-25 Signal
Direction
19 RxD+ 2 TxD+
20 RxD- 14 TxD-

17 RxC+ 24 TxCE+
18 RxC- 11 TxCE-
15 TxCE+ 17 RxC+

16 TxCE- 9 RxC-
3 TxC+ 15 TxC+
4 TxC- 12 TxC-

5.10 ATM over E3 Interface Cable

5.10.1 Introduction

The outward interface of 1AE3 has two SMB plugs, corresponding to Tx and Rx
respectively. The interface is the 75 unbalanced transmission mode, connecting
with the remote device by the 75 balanced coaxial cable. The lengths of cables
are 15 m and 30 m respectively. Users can choose the cable in the whole set of the
external cables the according to their needs.

5.10.2 Structure

The outline of E3 interface cable is shown in Figure 5-22.

BNC connector SMB connector

Figure 5-22 E3 cable outline

Huawei Technologies Proprietary

5-30
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

5.11 HSSI Cable

5.11.1 Introduction

High Speed Serial Interface cable has two types, that is, the DTE-to-DCE cable
(HSSI Interface Cable) and the DTE-to-DTE (Null Modem Cable). All are 3 m long.

I. DTE-to-DCE Cable

DTE-to-DCE cable is the straight-through cable. The line sequences of the twisted
pairs in the (DB-50) SCSI-II connectors of the two ends are the same. They are
used for the connection between the HSSI interface and the communication device
in the middle.

II. DTE-to-DTE Cable

DTE-to-DTE cable is the crossover cable. The line sequences of the twisted pairs in
the (DB-50) SCSI-II connectors of the two ends are different. They are used for the
back-to-back connection among the DTE devices.

5.11.2 Structure

DTE-to-DCE cable and DTE-to-DTE cable are both the shielded twisted pair cables.
They adopt the (DB-50) SCSI-II and have the similar pin assignments as shown in
Figure 5-23.

A B

W1
A B

Label

X0 X1

Figure 5-23 DTE-to-DCE cable

The pin assignments of DTE-to-DCE cables (HSSI Interface Cable) is shown in


Table 5-22. The pin assignments of DTE-to-DTE cables (Null Modem Cable) is
shown in Table 5-23.

Huawei Technologies Proprietary

5-31
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

Table 5-22 The pin assignments of the DTE-to-DCE cable (HSSI Interface Cable)

(DB50) (DB50)S
Relation Color Signal Direction Signal
SCSI-II CSI-II

White 1 SG 1 SG
Pair 1 -
Blue 26 SG 26 SG
White 2 RT+ 2 RT+
Pair 2 Orang
27 RT- 27 RT-
e

White 3 CA+ 3 CA+


Pair 3
Green 28 CA- 28 CA-
White 4 RD+ 4 RD+
Pair 4
Brown 29 RD- 29 RD-
White 5 LC+ 5 LC+
Pair 5
Gray 30 LC- 30 LC-
Red 6 ST+ 6 ST+
Pair 6
Blue 31 ST- 31 ST-
Red 7 SG 7 SG
Pair 7 Orang -
32 SG 32 SG
e

Red 8 TA+ 8 TA+


Pair 8
Green 33 TA- 33 TA-
Red 9 TT+ 9 TT+
Pair 9
Brown 34 TT- 34 TT-
Red 10 LA+ 10 LA+
Pair 10
Gray 35 LA- 35 LA-
Black 11 SD+ 11 SD+
Pair 11
Blue 36 SD- 36 SD-
Black 12 LB+ 12 LB+
Pair 12 Orang
37 LB- 37 LB-
e

Black 13 SG 13 SG
Pair 13 -
Green 38 SG 38 SG
ancillary ancillary to
Pair 14 Black 14 - 14
to DCE DCE

Huawei Technologies Proprietary

5-32
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

(DB50) (DB50)S
Relation Color Signal Direction Signal
SCSI-II CSI-II

ancillary ancillary to
Brown 39 39
to DCE DCE
ancillary ancillary to
Black 15 15
to DCE DCE
Pair 15 -
ancillary ancillary to
Gray 40 40
to DCE DCE

ancillary ancillary to
Yellow 16 16
to DCE DCE
Pair 16 -
ancillary ancillary to
Blue 41 41
to DCE DCE

ancillary ancillary to
Yellow 17 17
to DCE DCE
Pair 17 -
Orang ancillary ancillary to
42 42
e to DCE DCE

ancillary ancillary to
Yellow 18 18
to DCE DCE
Pair 18 -
ancillary ancillary to
Green 43 43
to DCE DCE

Yellow 19 SG 19 SG
Pair 19
Brown 44 SG 44 SG

ancillary
ancillary
Yellow 20 from 20
from DCE
DCE
Pair 20 -
ancillary
ancillary
Gray 45 from 45
from DCE
DCE

ancillary
ancillary
Violet 21 from 21
from DCE
DCE
Pair 21 -
ancillary
ancillary
Blue 46 from 46
from DCE
DCE
ancillary
ancillary
Violet 22 from 22
from DCE
DCE
Pair 22 -
ancillary
Orang ancillary
47 from 47
e from DCE
DCE

ancillary
ancillary
Pair 23 Violet 23 from - 23
from DCE
DCE

Huawei Technologies Proprietary

5-33
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

(DB50) (DB50)S
Relation Color Signal Direction Signal
SCSI-II CSI-II

ancillary
ancillary
Green 48 from 48
from DCE
DCE

ancillary
ancillary
Violet 24 from 24
from DCE
DCE
Pair 24 -
ancillary
ancillary
Brown 49 from 49
from DCE
DCE

Violet 25 SG 25 SG
Pair 25 -
Gray 50 SG 50 SG

Table 5-23 The pin assignments of the DTE-to-DTE cable (Null Modem Cable)

(DB50)SC (DB50)SC
Relation Color Signal Direction Signal
SI-II SI-II

White 1 SG - 1 SG
Pair 1
Blue 26 SG - 26 SG

White 2 RT+ 9 TT+


Pair 2
Orange 27 RT- 34 TT-

White 3 CA+ 8 TA+


Pair 3
Green 28 CA- 33 TA-

White 4 RD+ 11 SD+


Pair 4
Brown 29 RD- 36 SD-

Not
White 5 LC+ 10 LA+
connect
Pair 5
Not
Gray 30 LC- 35 LA-
connect

Not
Red 6 ST+ 6 ST+
connect
Pair 6
Not
Blue 31 ST- 31 ST-
connect

Red 7 SG - 7 SG
Pair 7
Orange 32 SG - 32 SG

Huawei Technologies Proprietary

5-34
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

(DB50)SC (DB50)SC
Relation Color Signal Direction Signal
SI-II SI-II

Red 8 TA+ 3 CA+


Pair 8
Green 33 TA- 28 CA-

Red 9 TT+ 2 RT+


Pair 9
Brown 34 TT- 27 RT-
Not
Red 10 LA+ 5 LC+
Pair 10 connect
Gray 35 LA- not connect 30 LC-

Black 11 SD+ 4 RD+


Pair 11
Blue 36 SD- 29 RD-

Loopb
Loopbac
ack(no
k(not
Black 12 t - 12
connecte
conne
d)
cted)
Pair 12
Loopb
Loopbac
ack(no
k(not
Orange 37 t - 37
connecte
conne
d)
cted)

Black 13 SG - 13 SG
Pair 13
Green 38 SG - 38 SG

Not
Black 14 - 14 Not used
used
Pair 14
Not
Brown 39 - 39 Not used
used

Not
Black 15 - 15 Not used
used
Pair 15
Not
Gray 40 - 40 Not used
used

Not
Yellow 16 - 16 Not used
used
Pair 16
Not
Blue 41 - 41 Not used
used

Not
Yellow 17 - 17 Not used
used
Pair 17
Not
Orange 42 - 42 Not used
used

Huawei Technologies Proprietary

5-35
Hardware Description
Quidway NetEngine20E Series Routers Chapter 5 Cable

(DB50)SC (DB50)SC
Relation Color Signal Direction Signal
SI-II SI-II

Not
Yellow 18 - 18 Not used
used
Pair 18
Not
Green 43 - 43 Not used
used

Yellow 19 SG - 19 SG
Pair 19
Brown 44 SG - 44 SG

Not
Yellow 20 - 20 Not used
used
Pair 20
Not
Gray 45 - 45 Not used
used

Not
Violet 21 - 21 Not used
used
Pair 21
Not
Blue 46 - 46 Not used
used

Not
Violet 22 - 22 Not used
used
Pair 22
Not
Orange 47 - 47 Not used
used

Not
Violet 23 - 23 Not used
used
Pair 23
Not
Green 48 - 48 Not used
used

Not
Violet 24 - 24 Not used
used
Pair 24
Not
Brown 49 - 49 Not used
used

Violet 25 SG - 25 SG
Pair 25
Gray 50 SG - 50 SG

Note:
Refer to the above table to differ and produce two Ethernet cables. Arrange the line
order according to the above chromatogram strictly.

Huawei Technologies Proprietary

5-36
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Appendix A List of Indicators ......................................................................................................A-1


A.1 Board Indicators ................................................................................................................A-1
A.1.1 RPU Indicators........................................................................................................A-1
A.1.2 NPU Indicators........................................................................................................A-2
A.1.3 HIC/FIC Indicators ..................................................................................................A-2
A.2 Fan Module Indicators.......................................................................................................A-3
A.3 Power Module Indicators...................................................................................................A-3

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators

Appendix A List of Indicators

A.1 Board Indicators


A.1.1 RPU Indicators

The status and description of RPU indicators are shown in Table A-1.

Table A-1 Discription of the RPU front panel components

Name Silkscreen Description


It indicates the system running LED, including the
warnings of fan, power supply and NPU. Constant ON
SYS
means the RPU has revcieved the warning, such as
ALM (red) the warning of supply power and fan.

It indicates the NPU failure LED. Constant ON means


NPU
the NPU has failed.

RUN It indicates the system running state LED. Blinking


means RPU works normally. Constant ON or OFF
RPU (green) meas RPU has failed.

MST It indicates the standby state LED. Constatn ON


means the standby RPU.

It indicates the system running state LED. Blinking


RUN means the NPU is in normal operation. Constant ON
NPU1 or OFF means the NPU has failed.
(green)
It indicates the standby state LED. Constant ON
MST
means the standby RPU.

It indicates the system running state LED. Blinking


RUN means the NPU is in normal operation. Constant ON
NPU2 or OFF means the NPU has failed.
(green)
It indicates the standby state LED. Constant ON
MST
means the standby RPU.

PRN It indicates the LED of the fan in position. Constant


(green) ON means the fan is in position.
FAN
It indicates the fan warning LED. Constant ON means
ALM (red)
the fan is not in position or its rotation is obstructed.

It indicates the LED of the first power module in


PRN position. Constant ON means the power module is in
(green) position. Constant OFF means the power module is
PWR1 not in position or has failed.

It indicates the first power module failure LED.


ALM (red)
Constant ON means the power module has failed.

Huawei Technologies Proprietary

A-1
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators

Name Silkscreen Description


It indicates the LED of the sencond power module in
PRN position. Constant ON means the power module is in
(green) position. Constant OFF means the power module is
PWR2 not in position or has failed.

It indicates the second power module failure LED.


ALM (red)
Constant ON means the power module has failed.

LINK OFF means the link is not connected and ON means


(green) the link is connected.
10/100Base-
TX interface OFF means no data is being transceived on the
ACT
interface and blinking means data is being transmitted
(yellow)
or received.

LINK OFF means the link is not connected and ON means


(green) the link is connected.
10/100/1000
M Ethernet 0 OFF means no data is being transceived on the
ACT
interface and blinking means data is being transmitted
(yellow)
or received.

LINK OFF means the link is not connected and ON means


(green) the link is connected.
10/100/1000
M Ethernet 1 OFF means no data is being transceived on the
ACT
interface and blinking means data is being transmitted
(yellow)
or received.

A.1.2 NPU Indicators

The status and description of NPU indicators are shown in Table A-2.

Table A-2 Description of NPU indicators

Name Description
It indicates the running LED. Constant ON means NPU works
RUN (Green) normally. Constant OFF means NPU is not in position or has
failed.
It indicates the alarm LED. Constant ON means NPU has
ALM (Red)
failed.

A.1.3 HIC/FIC Indicators

The status and description of HIC/FIC indicators are shown in Table A-3.

Huawei Technologies Proprietary

A-2
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators

Table A-3 LPU Indicators

Name Description
OFF means the link is not connected and ON means the link is
LINK (Green)
connected.

OFF means no data is being transmitted or received on the


ACT (Yellow) interface and blinking means data is being transmitted or
received.

A.2 Fan Module Indicators


The indicators of the fan module are located on the RPU front panel. The status and
description of the indicators are shown in Table A-4.

Table A-4 Indicators of the fan module

Name Color Description


RUN Green Constant ON means the FAN is operating normally.
ALM Red ON means some defaults occur to the FAN.

A.3 Power Module Indicators


The status and description of the power module indicators are shown in Table A-5.

Table A-5 Indicators of the power module

Name Color Implication


It indicates the power module input LED (only for AC Power
module).
AC OK Green
Constant ON means the normal voltage (100 V to 240 V) is
inputting, and OFF means the voltage input is not normal.

It indicates the power module input LED (only for DC Power


module).
DC OK Green
Constant ON means the normal voltage (-48 V to -60 V) is
inputting, and OFF means the voltage input is not normal.

It indicates the power Module indicators.


RUN Green Constant ON means the power module runs normally, and
OFF means the power module has faults.

It indicates indicator for the power module fault.


ALM Red Constant ON means the power module has faults or is not
in position.

Huawei Technologies Proprietary

A-3
Hardware Description
Quidway NetEngine20E Series Routers Appendix A List of Indicators

The running state of the power module is available from the indicators of the RPU
front panel. The status and description of the indicators are shown in Table A-6.

Table A-6 Indicators of the power module on the RPU front panel

Type Silkscreen Description


It indicates the LED of the first power module in
position. Constant ON means the power module is in
PRN (green)
PWR1 position. Constant OFF means the power module is
LED not in position or has failed.

It indicates the first power module failure LED.


ALM (red)
Constant ON means the power module has failed.

It indicates the LED of the sencond power module in


position. Constant ON means the power module is in
PRN (green)
PWR2 position. Constant OFF means the power module is
LED not in position or has failed.

It indicates the second power module failure LED.


ALM (red)
Constant ON means the power module has failed.

Huawei Technologies Proprietary

A-4
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Appendix B List of Boards ...........................................................................................................B-1


B.1 Boards ...............................................................................................................................B-1
B.2 RPU ...................................................................................................................................B-2
B.3 10/100Base-TX FE Electrical Interface Module ................................................................B-4
B.4 100Base-FX Ethernet Optical Interface Module................................................................B-4
B.5 1000Base-X Ethernet Optical Interface Module................................................................B-5
B.6 Channelized or Unchannelized E1/T1 Interface Module...................................................B-6
B.7 Synchronous Serial Port Module.......................................................................................B-7
B.8 ATM 155M Optical Interface Module.................................................................................B-8
B.9 ATM Over E3 Interface Module.........................................................................................B-9
B.10 Channelized or Unchannelized POS Optical Interface Module ....................................B-10
B.11 HSSI Interface Module ..................................................................................................B-11

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Appendix B List of Boards

B.1 Boards

Table B-1 lists the boards supported by the NE20E.

Table B-1 Boards supported by the NE20E

Silkscreen Full name


RPU Routing Process Unit

NPU Network Process Unit


2FE 2-port 10/10Base-TX FE electrical Interface Module
1-port 100Base-FX Ethernet Multi-mode optical
1MFX
interface module
4CE1 4-port channelized E1 module
4E1-F 4-port unchannelized E1 module
8CE1 8-port channelized E1 module
8E1-F 8-port unchannelized E1 module
4CT1 4-port channelized T1 module
8CT1 8-port channelized T1 module
4-port enhanced high-speed synchronous serial
4SAE
interface module
1-port ATM 155M Multi-mode optical interface
1ATM-OC3MM
module
1-port ATM 155M Single-mode optical interface
1ATM-OC3SM
module
1-port ATM 155M Single-mode long haul optical
1ATM-OC3SML
interface module
1AE3 1-port ATM over E3 module
1CPOS(E) 1-port channelized POS optical module
RT-HIC-2FE 2-port 10/10Base-TX FE electrical Interface Module
RT-HIC-4FE 4-port 10/10Base-TX FE electrical Interface Module
RT-HIC-8FE 8-port 10/10Base -TX FE electrical Interface Module
2-port 100Base-FX Ethernet signle/Multi-mode
RT-HIC-2FE-SFP
optical interface module

Huawei Technologies Proprietary

B-1
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Silkscreen Full name


4-port 100Base-FX Ethernet signle/Multi-mode
RT-HIC-4FE-SFP
optical interface module
8-port 100Base-FX Ethernet signle/Multi-mode
RT-HIC-8FE-SFP
optical interface module
RT-HIC-1GE 1-port 1000Base-X Ethernet optical interface module
RT-HIC-2GE 2-port 1000Base-X Ethernet optical interface module
1-port unchannelized POS/155M optical interface
RT-HIC-1POS
module

2-port unchannelized POS/155M optical interface


RT-HIC-2POS
module

4-port unchannelized POS/155M optical interface


RT-HIC-4POS
module

1HSSI 1-port HSSI interface module


2HSSI 2-port HSSI interface module

B.2 RPU

The attributes of the console port are shown in Table B-2.

Table B-2 Console interface attributes

Attribute Description
Connector type RJ-45
Standard RS-232
Baud rate 9600 bps to 115200 bps
9600 bps by default

The attributes of the AUX port are shown in Table B-3.

Table B-3 AUX interface attributes

Attribute Description
Connector type RJ-45
Standard Asynchronous EIA/TIA-232
Baud rate 300 to 115200 bps

Huawei Technologies Proprietary

B-2
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Attribute Description
PPP
Supported
SLIP
protocol
MP

The attributes of the 10/100Base-TX Ethernet port are shown in Table B-4.

Table B-4 10/100Base-TX Ethernet interface attributes

Attribute Description
Connector type RJ-45
Standard MDI

Ethernet_II

Supported Ethernet_SNAP
frame format IEEE 802.2
IEEE 802.3
10/100 Mbps autosensing
Operating
Full duplex
mode
Half-duplex
Supported
network IP
protocol

Attributes of the 10/100/1000M Ethernet interface are shown in Table B-5.

Table B-5 Attributes of the 10/100/1000M Ethernet interface

Attribute Description
Connector type SFP optical module
Number of
2 1
interfaces

Supported Ethernet_II
frame format Ethernet_SNAP
10M/100Mbps autosensing
Working mode
Full duplex
Supported
network IP
protocol

Huawei Technologies Proprietary

B-3
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

B.3 10/100Base-TX FE Electrical Interface Module

The attributes of the 10/100Base-TX FE Electrical Interface are shown in Table B-6.

Table B-6 Attributes of 10/100Base-TX FE electrical interfaces

Attribute Description
Connector type RJ45

Cable type Standard Ethernet cable


Transmission distance 100 m (with the Category 5 UTP cable)
Full duplex/Half-duplex
Operating mode
10M/100 Mbit/s auto-negotiation

Compliant standard IEEE 802.3u


Ethernet_II
Supported frame format
Ethernet_SNAP
Supported network protocol IP

B.4 100Base-FX Ethernet Optical Interface Module

The attributes of the 100Base-FX Ethernet optical interface are shown in Table B-8.

Table B-7 Attributes of 100Base-FX Ethernet optical interface

Item Description
SFP optical interface. For the module
Interface type
configuration, see Table B-8.
Duplex mode Full duplex
Rate 155 Mbit/s
Applicable standard IEEE 802.3u
Ethernet_II
Supported frame format
Ethernet_SNAP

Supported network protocol IP

Huawei Technologies Proprietary

B-4
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Table B-8 Attributes of 100M-FX Ethernet interface SFP optical module

Description
100M single-mode
100M multi-mode optical
Item optical interface
interface module
module
100Base-FX
100Base-FX
Connector type SC SC
Transmitt Minimum -15 dBm -19 dBm
ing
power Maximum -8 dBm -14 dBm

Receiver sensitivity -28 dBm -30 dBm


Overload power -8 dBm -14 dBm
Sender type LD LED
Center wavelength 1310 nm 1310 nm
Maximum
15 km 2 km
transmission distance

B.5 1000Base-X Ethernet Optical Interface Module

The attributes of the 1000Base-X Ethernet optical interface are shown in Table B-9.

Table B-9 Attributes of 1000Base-X Ethernet interface module

Description
Item
2GE 1GE
Interface
2 1
number
Duplex mode Full duplex
Rate 1.25 Gbit/s
Standard
IEEE 802.3z
compliance
Ethernet_II
Frame format
Ethernet_SNAP
Network
IP
protocol

Huawei Technologies Proprietary

B-5
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Table B-10 Attributes of SFP optical module of 1000Base-X Ethernet interface

Description

1000M 1000MS
1000M 1000M
Single-mode ingle-mode
Single-mod Multi-mode
long haul ultra long
e optical optical
Item optical haul optical
interface interface
interface interface
module module
module
1000Base-L 1000Base-S module
1000Base-L
X X 1000Base-LX X
Connector type LC LC LC LC
Minim
Transmitt -9.5 dBm -9.5 dBm -4 dBm -3 dBm
um
ing
power Maxim
-3 dBm -4dBm 1 dBm 2 dBm
um

Minim
Receiver -24 dBm -21 dBm -30 dBm -30 dBm
um
sensitivit
y Maxim
-20.5 dBm -18 dBm -21 dBm -23 dBm
um

Sender type LD LED LD LD


1550
Center wavelength 1310 nm 850 nm 1550 nm
nm/1310nm

Maximum
transmission 10 km 500 m 40 km 70 km
distance

B.6 Channelized or Unchannelized E1/T1 Interface Module

The attributes of the Channelized/unchannelized E1/T1 Interface are shown in Table


B-11.

Table B-11 Attributes of channelized/unchannelized E1/T1 interface

Attribute Description

Connector type DB-68

75 coaxial cable
Line interface
120 shielded twisted pair cable

Huawei Technologies Proprietary

B-6
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Attribute Description

75
coaxial 500 m
Maximum cable
transmit 120
distance shielded
150 m
twisted
pair cable

ITU-T G.703
Interface standard
G.704

E1 mode: 2048 kbit/s


Working mode
CE1 mode: N x 64 kbit/s (N=1, 2, 331)

PPP
MP
Supported protocol
Frame Relay
MFR

B.7 Synchronous Serial Port Module

The attributes of the synchronous serial port are shown in Table B-12.

Table B-12 Attributes of 4SAE interface

Attribute Description

Connector type DB-28

Interface standard and V.24 V.35, RS449, RS530, X.21


working mode DTE and DCE DTE DCE

Minimum baud rate


1200 1200
(bit/s)

Maximum baud rate


64K 4.096M 2.048M
(bit/s)

Huawei Technologies Proprietary

B-7
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Attribute Description

V.24 DTE cable


V.24 DCE cable
V.35 DTE cable
V.35 DCE cable
X.21 DTE cable
Cable type
X.21 DCE cable
RS449 DTE cable
RS449 DCE cable
RS530 DTE cable
RS530 DCE cable

PPP
HDLC
Supported protocol Frame Relay
MFR
MP

B.8 ATM 155M Optical Interface Module

The attributes of the synchronous serial port are shown in Table B-13.

Table B-13 Attributes of ATM 155M optical interface

Attribute Description
Interface
155 Mbit/s
rate

Interface
SONET/SDH
standard
ATM Traffic Constant Bit Rate (CBR)
Supported rt_Variable Bit Rate-Real Time (VBR)
services
type nrt_Variable Bit Rate-Non Real Time (VBR)
Unspecified Bit Rate (UBR)

Huawei Technologies Proprietary

B-8
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Attribute Description
IPoA

Supported IPoEoA
protocol PPPoA
PPPoEoA

Table B-14 Attributes of the optical module with the ATM 155M optical interface

Description

Item Multi-mode Single-mode Single-mode


optical optical optical interface
interface interface with long haul
Connector type SC SC SC

Transmitting Minimum -15 dBm -19 dBm -5 dBm


power Maximum -8 dBm -14 dBm 0 dBm

Minimum -28 dBm -30 dBm -34 dBm


Receiver
sensitivity
Maximum -8 dBm -14 dBm -10 dBm

Sender type LED LD LD


Wavelength 1310 nm

Maximum transmission
2 km 15 km 30 km
distance

B.9 ATM Over E3 Interface Module

The attributes of the ATM over E3 are shown in Table B-15.

Table B-15 Attributes of ATM over E3 interface

Item Description
Connector
SMB (34.368M electrical Interface)
type

Interface
75 coaxial cable
cable

Maximum
transmission 100 m
distance

Huawei Technologies Proprietary

B-9
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Item Description
Standard
ITU-T G.703
compliance
Rate 34.368 Mbit/s

IPoA

Supported IPoEoA
protocol PPPoA
PPPoEoA
Supported
CBR, UBR, nrt_VBR and rt_VBR
service type

B.10 Channelized or Unchannelized POS Optical Interface


Module

The attributes of the channelized/unchannelized POS optical interface are shown in


Table B-16.

Table B-16 Attributes of channelized/unchannelized POS optical interface

Item Description

Rate 155 Mbit/s


Unchannelized: 155 Mbit/s and full-duplex
Operating mode
channelized: 63 E1 channels or 84 T1 channels
STM-1/OC-3c SONET/SDH
Applicable standard
Supporting IETF RFC1619/1661/1662

Supported network
IP
protocol
PPP
HDLC
Supported protocols
Frame Relay
MFR

Huawei Technologies Proprietary

B-10
Hardware Description
Quidway NetEngine20E Series Routers Appendix B List of Boards

Table B-17 Attributes of SFP optical module with the channelized/unchannelized


POS optical interface

Description

Item Single-mo Single-mode


Multi-mo Single-mod
de shot super long
de e long haul
haul haul

Connector type LC LC LC LC

Transmitti Minimum -15 dBm -19 dBm -5 dBm -5 dBm


ng power Maximum -8 dBm -14 dBm 0 dBm 0 dBm

Minimum -28 dBm -30 dBm -34 dBm -34 dBm


Receiver
sensitivity
Maximum -8 dBm -14 dBm -10 dBm -10 dBm

Sender type LD LED LD LD


Wavelength 1310 nm 1550nm
Maximum transmission
15 km 2 km 40 km 80 km
distance

B.11 HSSI Interface Module

The attributes of the HSSI interface are shown in Table B-18.

Table B-18 Attributes of HSSI interface

Item Description
Type HSSI electrical interface
Rate 52 Mbit/s
Working mode Unchannelized: 51.84M
Standard
Compliant with STS-1
compliance

Supported
IP
network protocol

Supported link PPP


layer protocols HDLC

Huawei Technologies Proprietary

B-11
Hardware Description
Quidway NetEngine20E Series Routers Table of Contents

Table of Contents

Appendix C Acronyms and Abbreviations .................................................................................C-1

Huawei Technologies Proprietary

i
Hardware Description
Quidway NetEngine20E Series Routers Appendix C Acronyms and Abbreviations

Appendix C Acronyms and Abbreviations

A
AC Alternating Current
ATM Advanced Traffic Management
AUX Auxiliary (port)

C
CPU Central Processing Unit
CSU Channel service unit

D
DC Direct Current
DCD Data Carrier Detect
DCE Data Circuit-terminating Equipment
DSR Data Set Ready
DSU Data Service Unit
DTE Data Terminal Equipments
DTR Data Terminal Ready

E
EMC Electro Magnetic Compatibility
EPLD Erasable Programmable Logic Device

F
FE Fast Ethernet
FIC Flexible Interface Card
FPGA Field Programmable Gate Array

G
GE Gigabit Ethernet
GND Ground

Huawei Technologies Proprietary

C-1
Hardware Description
Quidway NetEngine20E Series Routers Appendix C Acronyms and Abbreviations

H
HDLC High-level Data Link Control
HIC High-speed Interface Card

I
IEEE Institute of Electrical and Electronics Engineers
IETF Internet engineering task force
IP Internet Protocol
ISDN Integrated Services Digital Network

L
LAN Local Area Network
LC Lucent Connector
LD Laser Diode
LED Light-emitting diode

M
MFR Multiple Frame Relay
MP Multilink Protocol
MPLS Multiprotocol Label Switching
MTBF Mean Time Between Failure
MTTR Mean Time To Repair

N
NEG Negative
NPU Network Process Unit
NVRAM Non-Volatile Random Access Memory

O
ODF Optical Distribution Frame

P
PC Personal Computer
PGND Protection Ground

Huawei Technologies Proprietary

C-2
Hardware Description
Quidway NetEngine20E Series Routers Appendix C Acronyms and Abbreviations

POS Packet Over SDH/SONET


PPP Point-to-Point Protocol
PPPoA Point to Point Protocol over ATM Adaptation Layer
5
PRI Primary Rate Interface

Q
QoS Quality of Service

R
RH Relative Humidity
RJ45 Registered Jack 45
RPM Round Per Minute
RPU Routing Process Unit

S
SA Security Association
SC Square Connector
SDH Synchronous Digital Hierarchy
SDRAM Synchronous Dynamic Random Access Memory
SFP Small Form-Factor Pluggable
SLIP Serial Line Internet Protocol
SMB Sub-miniature B
SNAP Sub Network Access Point
SONET Synchronous Optical Network
ST Segment Type

U
UBR Unspecified Bit Rate
UL Underwriter Laboratories Inc.

V
VBR Variable Bit Rate

Huawei Technologies Proprietary

C-3
Hardware Description
Quidway NetEngine20E Series Routers Index

Index

Console port cable, 5-4


A
air flow of the heat dissipation system, 3-3 D
appearance DC power cable, 5-2
ATM over E3 interface module ATM over E3 DC-input power supply
interface module indicator, A-3, A-4
panel, 4-33 dSchematic Diagram
channelized and unchannelized E1/T1 interface of the straight-through cable, 5-6
module channelized and unchannelized E1/T1
interface module E
panel, 4-22, 4-25
E3 cable outline, 5-30
channelized/unchannelized POS optical
EMC, 1-1
interface module channelized/unchannelized
ethernet interface attributes interface attributes
POS optical interface module
ethernet, B-3
panel, 4-35
of HIC/FIC components, 4-4
F
of NPU components, 4-4
fan module
of RPU components, 4-3
indicator, A-3
of the AC power supply module, 2-1
FIC, 1-1, 4-3
of the DC power supply module, 2-1
function
ATM over E3 interface module
ATM over E3 interface module ATM over E3
Attributes, 4-33
interface module
AUX interface attributes interface attributes
function, 4-32
AUX, B-2
Channelized/unchannelized E1/T1 interface
module Channelized/unchannelized E1/T1
B
interface module
board
function, 4-21
dimension, 4-4
channelized/unchannelized POS optical
list, B-1
interface modules channelized/unchannelized
type, 4-1
POS optical interface modules
function, 4-35
C
fan module, 2-4, 3-2, 4-6
Channelized E3/T3, 4-24 NPU NPU
channelized/unchannelized E1/T1 interface function, 4-12
module power module, 2-4
Attributes, 4-24, 4-26 RPU RPU
console interface attributes interface attributes function, 4-6
console, B-2

Huawei Technologies Proprietary

i-1
Hardware Description
Quidway NetEngine20E Series Routers Index

H R
HIC, 1-1, 4-3 relationship between the interface type and
corresponding optical fiber, 5-7
I RPU, 1-1, 3-2, 4-6, 4-7, 4-8, 4-9, A-1, B-2

indicator interfaces, 4-9

DC-input power supply, A-3, A-4 RS449 DCE cable, 5-22

fan module, A-3 RS449 DTE cable, 5-21

LPU, A-3 RS530 DCE cable, 5-22

indicators RS530 DTE cable, 5-22, 5-27

the AC power supply, 2-3


the DC power supply, 2-3 S
the fan module, 3-2 synchronous serial port module
interface distribution on the board board Indicator, 4-28
interface distribution, 4-5 system configuration, 1-1, 1-3

L T
LPU technical parameter
indicator, A-3 fan module, 3-3
NPU NPU
O technical parameter, 4-14

outline power module, 2-4

LC/PC optical connectors, 5-8


outline V
SC/PC optical connector, 5-8 V.24 DCE cable, 5-20
V.24 DTE cable, 5-20
P V.35 DCE cable, 5-21, 5-24

physical specifications, 1-3, 1-4 V.35 DTE cable, 5-20, 5-23

pin assignment
DTE-to-DCE cable, 5-32 X
RS530 DCE cable, 5-29 X.21 DCE cable, 5-21, 5-25
V.24 DCE cable, 5-23 X.21 DTE cable, 5-21, 5-25
V.24 DTE cable, 5-22

i.

Huawei Technologies Proprietary

i-2

Das könnte Ihnen auch gefallen