THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before

installation).
FOR SERVICE PERSONNEL ONLY
! WARNING ! WARNING
Carefully read through the procedures of proper The unit should be mounted at stable, non-vibratory location which The Outdoor unit must be mounted at a location which can sup-
installation before starting installation work. can provide full support to the unit. port heavy weight. Otherwise, noise and vibration will increase.
The sales agent should inform customers regarding
the correct operation of installation. ! CAUTION ! CAUTION

INDOOR UNIT

OUTDOOR UNIT
SPLIT UNIT AIR CONDITIONER No nearby heat source and no obstruction near the air outlet is
allowed.
Do not expose the unit under direct sunshine or rain. Besides,
ventilation must be good and clear of obstruction.

Tools Needed For Installation Work The air blown out of the unit should not point directly to animals
INSTALLATION MANUAL The clearance distances from top, right and left are specified in
figure below.
or plants.
The clearances of the unit from top, left, right and front are specified
+ Screwdriver Measuring Tape Knife The location must be convenient for water drainage and pipe
in figure below. At least 3 of the above sides must be open air.
Indoor Unit Outdoor Unit Saw 65mm Power Drill Hexagonal Wrench connection with the Outdoor unit. Be sure that the hot air blown out of the unit and noise do not
To avoid interference from noise please place the unit and its
RAS-50WX8(W) Key ( 4mm) Wrench (14, 17, 22, 26, 27mm) disturb the neighbourhood.
remote controller at least 1m from the radio, television and inverter Do not install at a location where there is flammable gas, steam,
RAC-50WX8 Gas Leakage Detector Pipe Cutter Putty
RAS-50WX8(B) type fluorescent lamp. oil and smoke.
Vinyl Tape Pliers Flare Tool To avoid any error in signal transmission from the remote controller, The location must be convenient for water drainage.
please put the controller far away from high-frequency machines Place the Outdoor unit and its connecting cord at least 1m away
and high-power wireless systems. from the antenna or signal line of television, radio or telephone.
SAFETY PRECAUTION The installation height of indoor unit must be 2.3m or more. This is to avoid noise interference.
Do not install outdoor unit facing strong wind direction. It may
Read the safety precautions carefully before operating the unit. damage the fan motor.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign. Names of Indoor Components
The Length of Indoor Unit
No. Item Qty Connecting Cord
! WARNING ........ Incorrect methods of installation may cause death or serious injury. Figure showing the Installation ! CAUTION
Hanger 0.9m 1.6m of Indoor and Outdoor Unit.
! CAUTION ......... Improper installation may result in serious consequence. The installation height
1 1 of indoor unit must be
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating 2.3m or more.
the unit as described in the users guide.
Screw for Hanger Direction of Piping

2 (4.1x32) 6
! WARNING Horizontally
perpendicular
to the unit
Holder for Remote
Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you Connection
Controller
do the installation work yourself. 3 1 Be sure to 2
There are 6 directions above 50mm
completely
Please observe the instructions stated in the installation manual during the process of installation. Improper installation may 1
allowed, namely, horizontally seal any
cause water leakage, electric shock and fire. perpendicular to the unit, gap with above 100mm
AAA Size Battery putty.
vertically down from right,
Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the 4 2 horizontally out from right and

must not bend about 400mm


units may collapse and impose danger. horizontally out to left.
Observe the rules and regulations of the electrical installation and the methods described in the installation manual when Dont form the piping
Screw for holder of
dealing with the electrical work. Use power cables approved by the authorities of your country. downward at the left of the unit. above 100mm
Remote Controller
5 2

above 300mm
Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight (3.1x16) 2,300mm or more
after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating Dimension of Mounting Stand
of the Outdoor unit
and fire. Remote Controller
(unit : mm)
Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock 6 1

(10)

Maximum pipe length 30m


and fire may occur. 50

Minimum pipe length 10m


Mounting
Stand
Be sure to use the specified piping set for R-410A. Otherwise, this may result in broken copper pipes or faults.

330
310
Purifying Filter 6
When installing or removing an air conditioner, only specified refrigerant (R410A) shall be allowed, do not allow air or moisture 35 12

10
7 500 4
to remain in the refrigeration cycle. Otherwise, pressure in the refrigeration cycle may become abnormally high so that a rupture 1 125 5
3 The indoor piping should be
may be caused. Plug insulated with the enclosed
insulation pipe. (If the
Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous insulator is insufficient,
gas may occur. Names of Outdoor Components please use commersial
products).
After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks No. Item Qty
into the room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur. The difference in height
Bush between the indoor and
Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner above 200mm outdoor unit should be
8 2 kept max 10m.
technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc. above 50 mm when The connecting pipe, no
installed on the above 50mm matter big or small,
Drain Pipe ceiling of balcony
give clearance should all be insulated
! CAUTION 9 1 as wide as
possible
with insulation pipe and
then wrapped with vinyl
tape. (The insulator will
A circuit breaker or fuse (16A time delay) must be installed. Without a circuit breaker or fuse the danger of electric shock deteriorate if it is not
exists. wrapped with tape).
above
A main switch with a contact gap of more than 3mm has to be installed in the power supply line to the outdoor unit. above 100mm 200mm The connection of insulated
drain hose.
Do not install the unit near a location where there is flammable gas. The outdoor unit may inner diameter 16mm
catch fire if flammable gas leaks around it. above 200mm
Please ensure smooth flow of water when installing the drain hose.
Please use insulated drain
Piping shall be suitable supported with a maximum spacing of 1m between the supports. hose for the indoor piping
(commercial product).

1 Installation of Hanger, Wall Penetration and Installation of Protection Pipe 2 Installation of the Indoor Unit INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION
The refrigerating pipes should be adjusted to fit into
! CAUTION VERTICALLY DOWNWARD PIPING the hole on the wall and then ready for further
connection. Drain hose
The draining of the water container inside the indoor unit can be done from the left. Preparation The terminals of 2 connected pipes must be covered
Therefore the hanger must be fixed horizontally or slightly tilted towards the side with insulator used for terminal connection. Then the
Connect connecting cord.
of drain hose. Otherwise, condensed water may overflow the water container. pipes are wrapped with insulation pipe. Connecting
Pull out the pipe, connecting cord and drain hose. Connect the connecting cord after removing electrical cord
Connecting cords, pipe and
cover. (Refer to CONNECTION OF POWER CORD)
Direct Mounting On The Wall Installation drain hose must be laid
together with Vinyl tape. After adjustment, fit the connecting cord and pipes
Pipe
Please use hidden beams in the wall to hold the hanger. into the space available under the indoor unit. Use
The upper part of the Indoor unit is hanged on the hanger. ! CAUTION
The projection at the lower part of the Indoor unit is hooked onto the hanger. holder to hold them tight.
The rubber strap used for
80 77
Hanger 1 Hanger fixing the insulator should
! CAUTION not be tied with great force.
295

Lift the body


65 Refrigerating of the unit Otherwise, this will damage
65 Please pull the lower part of
Pipe upwards and heat insulation and causes
100

the Indoor unit outwards to


then force it water condensation.
55

55

downwards. check if the unit is hooked


50 82 onto the hanger. Improper Insulation pipe (must be wrapped with vinyl tape at every 120mm).
795 Protection 2
installation may cause Holder can be attached at the either of 2 places.
Pipe Drain Hose Connecting
Cord Projection vibration and noise. Please select the easier position. Pipe Rubber strap tied with great force

Level THE CONNECTION OF REFRIGERATING PIPE DURING THE


Mark HOW TO REMOVE INDOOR UNIT INSTALLATION OF INDOOR UNIT
Screw for Hanger Hanger
Please use more Push up the (PUSH) sections at the Preparation To Install Refrigerating Pipes ! CAUTION
than 4 screws. bottom of the indoor unit and pull the The refrigerating pipes and connecting cord
bottom plate towards you. Then the
Please fix in the plastic core
transform and are attached. after flaring to avoid plastic
claws are released from the stationary The end of the refrigerating pipes are at locations chips entering the pipes.
plate.
Hole for pipe (The (PUSH) sections are indicated by marked with  symbol.
2 arrows in the right figure) [Push] mark positions
Procedures of Installation and Precautions
INDOOR UNIT

Procedures to fix the hanger.


below
1. Drill holes on wall. 2. Push plug into the holes. 3. Fix the hanger on wall 5mm
(As shown below) (As shown below) with 4.1 x 32 screw HORIZONTAL PIPING Please bend at a small
radius to form an arc
(As shown in figure below)
Preparation 0.85m
Ceiling
Wall
above 50mm
Change of Drain Hose and Installation Procedures.
1 Hanger
Plug
Installation
Exchange the location of drain hose and drain cap during horizontal piping as shown in
4.8mm

2 Screw
figure below. Be sure to plug in the drain hose until the insulating material folds upon Hang the Indoor unit onto the hanger. Use the temporary
itself. stand at the back of the Indoor unit to push its lower part Projection
15cm forwards.
Please use pliers to pull out the drain cap. Hook
32mm Place the drain hose through the hole on the wall.
Wall (This is an easier way to remove the drain cap).
4.1 x 32 Screw Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe.
Procedures to fix the holder of remote control.
Connect the connecting cord after removing electrical cover.
1. Drill holes on wall. 2. Push plug into the holes.
(Refer to Connection of Power Cord)
(As shown below) (As shown below)
After adjustment, the connecting cord and refrigerating pipes about 15cm
Wall
are placed into the space available under the Indoor unit.
3 Remote The projection of Indoor unit must hook to the hanger.
4.4mm

Control
Holder
Drain cap Drain hose Heat insulation pipe
5 Screw
Protection pipe
20mm Plug Drain hose
Connecting
Pull this to the front
Drain cap during the connection
Drain hose cord
of refrigerating pipes Connecting cord
Please insert Please insert Refrigerating pipe to ease task. Holder Connected section
Wall Penetration and Installation of Protection Pipe until here until here
Drill a 65mm hole on
wall which is slightly
3 Installation of Drain Hose
Indoor Outdoor ! WARNING ! CAUTION Condensed water may leak out if not inserted properly.
tilted towards the Seal with 2 ~ 5mm
outdoor side. Drill the putty Be sure that the wire is not
Seal with
wall at a small angle. putty in contact with any metal HORIZONTAL & DOWNWARD PIPING MAKING OPENINGS ! CAUTION
in the wall. Please use the
Cut the protection pipe During horizontal or downward piping, use a knife to cut
protection pipe as wire Be sure that the
according to the wall passing through the openings as shown in figure. Then smoothen the edges of drain hose is not
thickness. hollow part of the wall so openings with a file. Condensed loosely con-
Ditch
Empty gap in the sleeve as to prevent the Pipe
water pond nected or bend.
possibility of damaged by Openings
of protection pipe should Protection WALL support Bending Condensed
be completely sealed pipe mouse. upwards water pond

with putty to avoid Sleeve of Unless it seals completely,


any air with high humidity You are free to choose the side (left or right) for the installation of drain
dripping of rain water protection !
pipe flows from outdoor and Turn the piping while holding down the lower hose. Please ensure the smooth flow of condensed water of the Indoor
Pull up the pipe after
into the room. any dew may drop. bending downward portion of pipe-support by hand. CAUTION unit during installation. (Carelessness may result in water leakage.)

<IA438: A >
Please mount the Outdoor unit of stable ground to prevent vibration and increase 1 Preparation of Pipe 3 Removal Of Air From The Pipe And Gas Leakage Inspection
of noise level.

INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL


Decide the location for piping after sorting out the different types of pipe available. Use a pipe cutter to cut the copper pipe.
When removing side cover, please pull the handle after undoing the hook by Procedures of using Vacuum Pump for Air Removal
pulling it downward. Reinstall the side cover in the reverse order of the removal. Trimming tool When the meter reaches - 101KPa
(-76cmHg) during pumping, fully
Please face this side (suction side) As shown in right figure, remove the cap tighten the shuttle.
Please remove side cover Copper pipe
of the unit to the wall. of valve core. Then, connect the charge Meter showing pressure
when connecting the piping
1 hose. Remove the cap of valve head. Closed
and connecting cord.
Connect the vacuum pump adapter to Lo Hi R410A
the vacuum pump and connect the Manifold valve
! CAUTION charge hose to the adapter. Valve
Charge hose
Vacuum
Valve
Jagged edge will cause leakage. pump

Pull downward Point the side to be trimmed downwards during trimming to prevent copper

AIR REMOVAL
Vacuum pump
chips from entering the pipe. adapter
Fully tighten the Hi shuttle of the
CAUTION Before flaring, please put on the flare nut. manifold valve and completely unscrew
the Lo shuttle. Run the vacuum pump
OUTDOOR UNIT

Do not touch the suction port, Die


Die
A
2 for about 1015 minutes, then completely
bottomsurface, or aluminum Recommend to use When pumping starts, slightly loosen the
R410A flaring tool. tighten the Lo shuttle and switch off flare nut to check of air sucked in. Then
fin of the outdoor unit.
the vacuum pump. tighten the flare nut.
Failure to do so may cause Copper pipe
an injury.
Outer A (mm)
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT Diameter (mm) For R410A tool For R22 tool Completely unscrew the spindle of the
The body of
service valve (at 2 places) in anti-
There is holes on the base of Outdoor unit for condensed water to exhaust. 6.35 0.0 ~ 0.5mm 1.0mm 3 clockwise direction to allow the flow of
service valve

In order to flow condensed water to the drain, the unit is installed on a stand or a
9.52 0.0 ~ 0.5mm 1.0mm coolant (using Hexagonal Wrench key).
block so that the unit is 100mm above the ground as shown figure. Join the drain
pipe to one hole. 12.7 0.0 ~ 0.5mm 1.0mm Cap of
valve core
Cover the drain hole with a bush. To install the bush, put it on the drain hole as Hexagonal
Wrench Key
shown in the figure and press the both sides of the bush to fit into the hole. 2 Pipe Connection Cap of valve head
Remove the charge hose and tighten the
After installation, check whether the drain pipe and bush cling to the base firmly.
cap of valve head. Check the caps
In case of removing flare nut of an Indoor unit, first remove a nut 4 periphery if there is any gas leakage.
BASE
! CAUTION of small diameter side, or a seal cap of big diameter side will fly The task is then completed. Cap of valve head
DRAIN HOLE out. Prevent water from entering into the piping when working.
above
100mm
8 BUSH Outer Torque Nm
Push Push DRAIN HOLE 8 BUSH
dia.of pipe (kgf cm) Gas Leakage Inspection
9 DRAIN PIPE Small dia. side 6.35 (1/4") 13.7 18.6 (140 190)
Outer diameter: 16 mm or more
Large dia. side 9.52 (3/8") 34.3 44.1 (350 450) Please use gas leakage detector to check if leakage
Flare nut
Install the outdoor unit horizontally and make sure that condensate drains away. 12.7 (1/2") 44.1 53.9 (450 550) occurs at the connection of Flare nut as shown on
In case of using in cold weather area the right.
Valve Small dia. side 6.35 (1/4") 19.6 24.5 (200 ~ 250)
Especially, in case that there are heavy snows in cold weather area, condensed head cap Large dia. side
9.52 (3/8") 19.6 24.5 (200 ~ 250) If gas leakage occurs, further tighten the connection
water freezes on the base and may result not to drain. In this case, please Wrench Torque

remove the bush and the drain pipe at the bottom of unit. (Left and center near
wrench 12.7 (1/2") 29.4 34.3 (300 350) to stop leakage. (Use the detector provided for
discharge portion of air, each 1 place). It becomes smooth drain. Valve core cap 12.3 15.7 (125 ~ 160) R410A)
Ensure that the distance from the drain hole to the ground is 250 mm or more.

! WARNING THIS APPLIANCE MUST BE EARTHED. Wiring Of The Indoor Unit How To Connect The Optional Parts
For wire connection of the Indoor unit, you need to C (RAC Adapter, Weekly Timer, Wired Remote Control)
Power supply shall be connected at the rated voltage, otherwise the unit will remove front panel and electrical cover.
D
be broken or could not reach the specified capacity. Method to remove front panel
Refer to FINAL STAGE OF INSTALLATION How to
Procedures of Wiring Remove The Front Cover.
Indoor Unit Outdoor Unit
Method to remove the low cover

CD L NCD
Pull the cover at 1 and 2 in the directions RAC Adapter
1.6 or
2.0 as shown by arrows to remove the cover. Weekly timer/
Connect the
earth cord Wired remote controller
Connecting Cord Connecting Cord

2.0
AC 220 - 230V Fix the
CONNECTION OF POWER CORD

1 50Hz weekly timer/


Strip wires wired remote
100mm 160mm controller RAC Adapter
cord and cord
Outdoor Unit 10mm RAC adapter
10mm cord by
After remove the screw Weekly timer
and cover, and put the band.
connecting cords and fix
cord/
Wired remote
GRN + YEL 10mm Wiring Of The Outdoor Unit the cover with screw.
controller
160mm Please remove the side cover for wire connection. cord
Power line Control line
Cover
Indoor Unit
! WARNING
You may not be able to close the side cover due to the
30mm connecting cord, under such situation, please press H-LINK
against the wall of side cover to fix it. Earth terminal
10mm Detail of cutting the connecting cord Be sure that the hooks (2 places) are plugged in. [For all optional part, please refer catalog for part number]
Otherwise, water leakage may occur and this causes
When removing the connecting short circuit or faults. As for connecting to H-Link, a separately purchased
wires for the Indoor unit, please The connecting cord should not touch to service valve RAC Adapter is required.
remove the low cover panel in front and pipes. (It becomes high temperature in heating To install the wiring the electrical box cover must be opened.
10mm GRN + YEL of the unit. operation.) Connect the connector of RAC adapter to CN7.
Assemble back the cover of electrical box.
70mm
Strip wires Checking for the electric Investigate the power supply capacity and other
electrical conditions at the installation location.
Please refer to the respective user manual of RAC Adapter
for further details.

! WARNING
source and the voltage range Depending on the model of room air conditioner Please be careful not to damage lead wires by edge of
plate when connecting the optional parts.
Before installation, the power source must be checked and
to be installed, request the customer to make
The naked part of the wire core should be 10 mm and fix it to the terminal necessary wiring work must be completed. To make the wiring arrangements for the necessary electrical work
tightly. Then try to pull the individual wire to check if the contact is tight. capacity proper, use the wire gauges list below for the lead- etc. WEEKLY TIMER / WIRED REMOTE CONTROLLER
Improper insertion may burn the terminal. in from a pole transformer and for the wiring from a switch The electrical work includes the wiring work up
board of fuse box to the outlet in consideration of the locked the outlet. In localities where electrical [For all optional part, please refer catalog for part number]
Be sure to use only power cables approved from the authorities in your rotor current. conditions are poor, use of a voltage regulation
country. For example in Germany: Cable type: NYM 3x1.5mm2 (Fuse = 16A Connection to the electrical box:
IMPORTANT is recommended. Remove the cover of electrical box.
time delay). Install outlet for the room air conditioner within Connect the connector of Weekly Timer/wired remote
Please refer to the installation manual for wire connection to the terminals of Cable length Wire cross-section the reaching range of the line cord. controller to CN9.
the units. The cabling must meet the standards of electrical installation. Assemble back the cover of electrical box.
up to 16m 1.5mm2 Please refer to the respective user manual of Weekly Timer/
There is a AC voltage of 230V between the L and N terminals. Therefore, IMPORTANT
before servicing, be sure to remove the plug from the AC outlet or switch off up to 15m 2.5mm2 wired remote controller for further details.
Fuse Capacity
Please be careful not to damage lead wires by edge of
the main switch. up to 25m 4.0mm2 16A time delay fuse plate when connecting the optional parts.

1 Insulation And Maintenance Of Pipe Connection 2 Installation Of Remote Controller How to Remove The Front Cover How to Attach the Front Cover
The connected terminals should be completely sealed with The remote controller can be placed in its holder which is 1 Remove the front panel. 1 Check that the drain pan is securely attached.
heat insulator and then tied up with rubber strap. fixed on wall or beam. Please remove and attach the front panel by both hands.
Please tie the pipe and power line together with vinyl tape as To operate the remote controller at its holder, please ensure 2 After installing the front cover onto the unit, hook three
shown in the figure showing the installation of Indoor and that the unit can receive signal transmitted from the controller claws at upper side of the cover securely. Then, push the
Outdoor units. Then fix their position with holders. at the place where the holder is to be fixed. The unit will beep Locking mechanism center of the front cover to lock the claws.
FINAL STAGE OF INSTALLATION

To enchance the heat insulation and to prevent water


when signal is received from the remote controller. The signal
condensation, please cover the outdoor part of the drain hose 3 Tighten the two screws.
transmission is weaken by the fluorescent light. Therefore,
and pipe with insulation pipe.
Completely seal any gap with putty. during the installation of the remote control holder, please
switch on the light, even during day time, to determine the
Insulation material for pipe connection
mounting location of the holder.
To remove the front panel, slide Push to lock the claws
the front panel locking
mechanisms (left and right) toward
the directions as indicated by Remove the front panel by 4 Connect the wire connector. Close the electrical cover.
The controller must pulling it towards you.
arrows in the illustration, until you
be hooked onto the hear a clicking sound.
Sleeve of 5 Install the filter.
protection pipe
hook at the lower
Screw (2 pieces) After opening the front panel by both hands.
part of the holder.
Putty 1 Undo the right arm while pushing it inside. 6 Slide the shafts of the right and left arms on the washable
Push in the remote
2 Slide the front panel to right as shown in figure. Then panel along the steps to insert the shafts into the holes till
controller in the
they stop. After checking that the shafts are securely
direction as shown remove while pulling it to front.
Holder for inserted, close the panel.
in figure below. 3 Open the electrical cover. Disconnect the wire connector.
Remote Controller
Putty Remote 2 Remove the filters.
Controller
3 After removing two screws, pull the center of the front
3 Power Source And Operation Test cover towards you and release the claws. Arm
Slot
Power Source Operation Test 4 Pull the side faces (lower sections) of the front cover Step
Slot
towards you as shown in the figure and remove the
! CAUTION Please ensure that the air conditioner is in normal cover. Disconnect the wire connector
operating condition during the operation test.
Please use a new socket. Accident may occur due to the use of old Explain to your customer the proper operation
socket because of poor contact. procedures as described in the users manual.
Please plug in and then remove the plug for 2 3 times. This is to Firmly insert the front Slide the front panel
ensure that the plug is completely plugged into the socket. panel arms by sliding locking mechanisms
Keep additional length for the power cord and do not render the along the steps located (left and right) into the
plug under external force as this may cause poor contact. at the main body slots located at the
Do not fix the power cord with U-shape nail. Terminal cover main body, until you
hear a clicking sound.

<IA438: A >