Sie sind auf Seite 1von 3

RADDISON WC

Slab Reinforcement Design Calc. By: HA


MISC050 NOV2016 Rev: 1 Checked By: HS

Slab Reinforcement Design

LEGEND:
d/h = Slab Effective/Total Depths (d=h-cover)
g/q = Dead/Live Loads (not factored)
L1 = Width of the Slab Along the Strip Direction
L2 = Width of the Slab Perpendicular to the Strip Direction
C = Moment Coefficient M=C p / L^2
M-span = Ultimate Span Moment
M-sup = Ultimate Support Moment
Mc = Balanced Support Moment
As = Steel Area (Required/Supplied)

Slab Strip: X2 -- Storey: 1


---------------------------
Materials: C20/25 / Grade 460 (Type 2)

Type g L1 C-sup C-span As


Slab d/h q L2 M-sup M-span Req/Sup S T E E L B A R S
(mm) (kN/m2) (mm) (kN.m) (kN.m) (mm2)

1S6 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 6850.00 9.5 StrBot: T10-
250(B1)
Deflection Check: L/d = 4.71 < 14.0 *** Sufficient ***

Support Mc = 32.0Support As = 514.03/628.32 SupTop: T10-


125(T1)

1S4 1 15.750 6500.00 0.0320 0.0240 383.34/392.7


165/200 1.500 6400.00 32.0 24.0 StrBot: T10-
200(B2)

Support Mc = 32.0Support As = 481.91/628.32 SupTop: T10-


125(T1)

1S3 1 15.750 4700.00 0.0485 0.0362 295.2/314.16


175/200 1.500 6400.00 26.2 19.6 StrBot: T10-
250(B1)
Deflection Check: L/d = 26.86 < 40.89 *** Sufficient ***

Support Mc = 26.2Support As = 405.23/523.60 SupTop: T10-


150(T1)

1S16 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 6850.00 9.5 StrBot: T10-
250(B1)
Deflection Check: L/d = 4.71 < 14.0 *** Sufficient ***

Slab Strip: X3 -- Storey: 1


---------------------------
Materials: C20/25 / Grade 460 (Type 2)

Type g L1 C-sup C-span As


Slab d/h q L2 M-sup M-span Req/Sup S T E E L B A R S
(mm) (kN/m2) (mm) (kN.m) (kN.m) (mm2)

1S7 12 4.800 800.00 0.5000 (Cantilever)

ProtaStructure v2.0.6 Page 1


RADDISON WC
Slab Reinforcement Design Calc. By: HA
MISC050 NOV2016 Rev: 1 Checked By: HS

170/200 6.000 6850.00 9.5 StrBot: T10-


250(B1)
Deflection Check: L/d = 4.71 < 14.0 *** Sufficient ***

Support Mc = 32.0Support As = 514.03/628.32 SupTop: T10-


125(T1)

1S1 1 15.750 6500.00 0.0320 0.0240 383.34/392.7


165/200 1.500 6400.00 32.0 24.0 StrBot: T10-
200(B2)

Support Mc = 32.0Support As = 481.91/628.32 SupTop: T10-


125(T1)

1S2 1 15.750 4700.00 0.0485 0.0362 295.2/314.16


175/200 1.500 6400.00 26.2 19.6 StrBot: T10-
250(B1)
Deflection Check: L/d = 26.86 < 40.89 *** Sufficient ***

Support Mc = 26.2Support As = 405.23/523.60 SupTop: T10-


150(T1)

1S17 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 6850.00 9.5 StrBot: T10-
250(B1)
Deflection Check: L/d = 4.71 < 14.0 *** Sufficient ***

Slab Strip: X4 -- Storey: 1


---------------------------
Materials: C20/25 / Grade 460 (Type 2)

Type g L1 C-sup C-span As


Slab d/h q L2 M-sup M-span Req/Sup S T E E L B A R S
(mm) (kN/m2) (mm) (kN.m) (kN.m) (mm2)

1S14 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 6950.00 9.5 StrBot: T10-
250(B1)
Deflection Check: L/d = 4.71 < 14.0 *** Sufficient ***

Support Mc = 32.0Support As = 480.97/628.32 SupTop: T10-


125(T1)

1S4 1 15.750 6400.00 0.0319 0.0246 370.85/392.7


175/200 1.500 6500.00 32.0 24.7 StrBot: T10-
200(B1)
Deflection Check: L/d = 36.57 < 38.11 *** Sufficient ***

Support Mc = 32.0Support As = 480.97/628.32 SupTop: T10-


125(T1)

1S1 1 15.750 6400.00 0.0319 0.0246 370.85/392.7


175/200 1.500 6500.00 32.0 24.7 StrBot: T10-
200(B1)
Deflection Check: L/d = 36.57 < 38.11 *** Sufficient ***

Support Mc = 32.0Support As = 496.10/628.32 SupTop: T10-


125(T1)

1S9 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 6950.00 9.5 StrBot: T10-
250(B1)

ProtaStructure v2.0.6 Page 2


RADDISON WC
Slab Reinforcement Design Calc. By: HA
MISC050 NOV2016 Rev: 1 Checked By: HS

Deflection Check: L/d = 4.71 < 14.0 *** Sufficient ***

Slab Strip: X5 -- Storey: 1


---------------------------
Materials: C20/25 / Grade 460 (Type 2)

Type g L1 C-sup C-span As


Slab d/h q L2 M-sup M-span Req/Sup S T E E L B A R S
(mm) (kN/m2) (mm) (kN.m) (kN.m) (mm2)

1S15 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 5150.00 9.5 StrBot: T10-
250(B1)
Deflection Check: L/d = 4.71 < 12.81 *** Sufficient ***

Support Mc = 17.3Support As = 295.20/314.16 SupTop: T10-


250(T1)

1S3 1 15.750 6400.00 0.0320 0.0240 295.2/314.16


165/200 1.500 4700.00 17.3 13.0 StrBot: T10-
250(B2)

Support Mc = 17.3Support As = 295.20/314.16 SupTop: T10-


250(T1)

1S2 1 15.750 6400.00 0.0320 0.0240 295.2/314.16


165/200 1.500 4700.00 17.3 13.0 StrBot: T10-
250(B2)

Support Mc = 17.3Support As = 295.20/314.16 SupTop: T10-


250(T1)

1S18 12 4.800 800.00 0.5000 (Cantilever)


170/200 6.000 5150.00 9.5 StrBot: T10-
250(B1)
Deflection Check: L/d = 4.71 < 12.81 *** Sufficient ***

ProtaStructure v2.0.6 Page 3