Power system engineering

Substation design
Eaton's Power System Engineering team is your Our team of experienced engi- Eaton's Electrical Services and
neers can provide the skills Systems is one of the largest
partner to build, remodel or expand your substation. needed to successfully com- and most experienced teams
Our experience and North American coverage make plete your project, from substa- of power system engineers in
tion design to system analysis the industry. We offer a full
Eaton the choice to serve your local or national needs. and simulation. Coupled with portfolio of engineering and
proven project management design services, energy
experience, Eaton can provide management audits and power
additional support up to and quality and reliability audits.
including turnkey EPC solutions. Whether you provide solar
energy to the electric grid
or oversee a mission-critical
operation where even a second
of downtime is unacceptable,
Eaton can help you stay open
for business.
Eaton's power system engineers bring extensive skills
and expertise to power system design and analysis.
Active participation in technical societies such as IEEE
and collaboration with a variety of utilities and indus-
tries ensures that our engineers are knowledgeable
about today's cutting edge engineering techniques.

Electrical design services Ground Grid Analysis and Additional substation engi- Warranty extension
Design calculations to neering and design capabilities and training
Eaton's electrical design
ensure the design provides Short/long term
services can extend from the Civil and structural design
adequate safety for personnel maintenance contracts
transmission line to customer through 345 kV
during ground fault conditions.
motors and equipment. Design Control house layout 24/7 remote monitoring
Modeling of the ground grid
services are integrated with and design with expert support
under fault conditions and
analysis services, resulting in a
calculation of the ground Pager-alert of critically
complete engineered solution.
potential rise and step and Multi-vendor monitored parameters
The level of design detail can be
touch potentials throughout equipment supply
customized from minimal design Immediate personnel dispatch
the substation. Determination
consultation and advice to a Supply of the complete based on remote indication
of optimal substation ground
complete design package with range of Eaton substation
grid layout and specifications,
specifications and drawings. product lines Additional power system
or recommendations for
Typical substation electrical design and analysis services
improving existing grids. Coordination and resale of
design services include:
Other electrical engineering all third-party customer In addition to substation design
may include conduit or trench preferred components services, Eaton offers extensive
Substation layout sizing and layout, control panel Prefabricated control house analysis services to enhance
plan and elevation design, design, power factor correction and electrocenter supply performance and design,
equipment foundation and or harmonic filter design, and validate equipment selection
oil containment design. other associated tasks. Turnkey project and and simulate response to
Electrical Equipment Sizing construction management abnormal conditions, including:
Regulatory approval
and Specification Perform in conjunction with the design Single-point responsibility
necessary calculations process, navigate the utility throughout the entire project Short-circuit analysis
to determine appropriate and jurisdictional regulatory
equipment ratings, review requirements to gain project Centralized project Protective device coordination
of customer and site approval for the specific management group
Arc flash analysis
requirements, and provide project design. On-site installation supervision
applicable specifications. Load measurement,
Power Systems Engineering Standardized documentation load flow analysis,
Protection and Control is an integral part of Eaton's practices including scheduling, power factor correction
Selection and application electrical service capabilities. reporting and closeout
of electrical protection: The combined Eaton Electrical Power quality measurement,
substation equipment Services and Systems team can harmonic analysis, harmonic
Installation services mitigation and filter design
protection such as provide a full scope of Design
transformer, bus, breaker and Construction Management Nationwide subcontracting Transient stability analysis
failure, feeder, line and line Services to support your capability of all trades
Switching transient analysis,
terminal utility protection; project needs: Site preparation, excavation, surge suppression and
related communication design foundation installation and snubber design
such as transfer trip; generator control house construction
protection for generation sites. Energy management studies
Design of breaker control Steel dead-end and overhead
ranging from simple tripping bus structure assembly
schemes to automatic transfer Equipment set and connect Eaton can provide engineering
upon loss of source. services for a variety of systems
Acceptance testing and and sources:
installation certification
Solar (photovoltaic,
Start-up and ground-fault solar concentrator)
certifications
Geothermal
Eaton Electrical Asia Pacific Headquarter
Interconnect confirmation
No.3, Lane 280, Linhong Road, Changning and commissioning Wind
District, Shanghai Hydro
Tel:021-52000099 Fax:021-52000200
Post Code:200335 Biomass

Eaton Corporation
All Rights Reserved
Publication Number PA02703002E/3PC