This document provides specifications for the Terufusion Infusion Pump Models TE-135 and TE-135C. Key details include:
- It uses peristaltic finger pumping and can deliver fluids from 1-999 mL/hr in standard mode or 0.1-99.9 mL/hr in micro mode.
- It has alarms for issues like air in lines, occlusions, empty bags, and completed infusions. Safety features include tube clamping and key locks.
- Power options include AC 100-240V or 12-15V DC. It is classified for continuous use and measures 100x201x187mm and weighs 1.7kg.
This document provides specifications for the Terufusion Infusion Pump Models TE-135 and TE-135C. Key details include:
- It uses peristaltic finger pumping and can deliver fluids from 1-999 mL/hr in standard mode or 0.1-99.9 mL/hr in micro mode.
- It has alarms for issues like air in lines, occlusions, empty bags, and completed infusions. Safety features include tube clamping and key locks.
- Power options include AC 100-240V or 12-15V DC. It is classified for continuous use and measures 100x201x187mm and weighs 1.7kg.
This document provides specifications for the Terufusion Infusion Pump Models TE-135 and TE-135C. Key details include:
- It uses peristaltic finger pumping and can deliver fluids from 1-999 mL/hr in standard mode or 0.1-99.9 mL/hr in micro mode.
- It has alarms for issues like air in lines, occlusions, empty bags, and completed infusions. Safety features include tube clamping and key locks.
- Power options include AC 100-240V or 12-15V DC. It is classified for continuous use and measures 100x201x187mm and weighs 1.7kg.
Model TE 135 Infusion Set Designated TERUMO IV sets for pump Pumping System Peristaltic Finger Method Control Method Volumetric Control Delivery Rates STANDARD mode: 1 999 mL/h ( 1 mL/h step ) MICRO mode: 0,1 99.9 mL/h ( 0.1 mL/h step ) Delivery Limit 1 9999 mL ( 1 mL step ) or - - - - ( Delivery Limit Free ) Volume Delivered STANDARD mode : 0 to 9999 mL ( 1 mL step ) MICRO mode : 0.0 to 99.9 mL ( 0.1 mL step ) 100 to 9999 mL ( 1 mL step ) Flow Accuracy 10 % Conditions Infusion Set: Designated TERUMO IV sets for pump. Solutions : Water / Saline Test Time : Second Hour Delivery Rate : 1.0 mL/ h or more Temperature : 25 o Celcius With a designated Infusion Set water or saline, measured at 1 hours after start-up and subsequent every hour. ( Actual Flow Accuracy depends on the type of solution ) Occlusion Pressure 30 140 kPa ( 0.30 1.43 kgf/cm2 ) Purge Approx 500 mL/h Alarms Battery, Air-in-line, Occlussion, Door, Infusion Completion ( Keep Open Rate Function ), Repeat ( activated if the cause of the initial alarm remains for about 2 minutes ), Start Reminder ( activated if about 2 minutes wasted after infusion become available ), Battery Error, Delivery Rate/Delivery Limit Comparison alarms. Alarm when using Drip Sensor ( Option ): Empty, Flow Error ( Free Flow ) ( An alarm during infusion is recognized by the relevant alarm indicator or display, the operation indicator, a buzzer etc. The pump is stopped by any alarm other than the Battery ( except Shutdown ) and Infusion Completion Alarms Safety Functions Panel Lock : Disables the user to change the D Rate, D Limit values when the door is opened * Tube Clamp : Automatically presses and shuts the IV tubing when the door is opened Key Lock : Disables the switches except ( START ), ( KEY LOCK ), & ( POWER ). This function is deactivated when any alarm is occurred * Air in-line Detection Sensitivity : adjust the sensitivity of the air-in-line detector in 2 steps (Low/High;default: Low ) Occlusion Detection Sensitivity: Adjust in 10 steps ( default: 5 ) Maintenance Timer : Turns on the maintenance timer indicator after a specified time passes ( Default: not used ) Upper Limit of D Rate : Limit the maximum D Rate value withinthe predefined range Additional Function Volume Delivered Clear : Reset the volume delivered to 0 when pressing VOLUME DELIVERED switch for 2 second Alarm Volume : Adjust the alarm volume in four steps ( Small / Medium / Large / Step ( escalating ), default : Medium Shutdown : Turns the pump off after alarming if the internal battery voltage lower to a certain level during operation on the battery History : Activates the History mode to display the past operation record Stand-by : Deactivates the Start Reminder alarm for 20 minutes with a long press of the ( STOP/SILENCE ) switch Cable Disconnection Detection : Detect the power cable disconnection from the pump and gives an alarm * Buzzer Sound Option : Switches the alarm buzzer to a continuous sound Infusion Mode Limit : Disables the user to change MICRO mode Operating Conditions Temperature : 5 400 Celcius Humidity : 20 90 % Storage Conditions Temperature : - 20 450 Celcius Humidity : 10 95 % Power Supply AC : 100 240 Volt, 50/60 Hz DC : 12 15 Volt/DC Power Consumption 28 VA ( Watt )/ AC 100 240 Volt 11 Watt ( DC Power ) Classification Class I and Internal Power Supply Type CF, IPX1, Continuous operation Dimensions 100 mm (W) x 201 mm ( H) x 187 mm ( D ) Weight Approx 1.7 kg Accessories AC Power Cable, Pole Clamp, Time Lag Fuse ( 2 pcs ), Instruction Manual For Model TE-135C only: Nurse Call Output Connectable with nurse call via the computer interface/nurse call connector. Contact capacity: DC 12 Volt, 1 Ampere Computer Interface Data output available via RS232 or RS485 connector Accessories Computer Interface Protocol Optional Accessories DC Cable ( Sold Separately ) Drip Sensor ( Code No: TE*975 )