Sie sind auf Seite 1von 3

By decree of the ministry of economy and medium-sized businesses, technology and traffic in

Nordrhein-Westfalen dated 13.12.1999 according to RAP Stra approved for suitability tests of
bituminous building materials and joint sealants

Page 1 of 3 to Test Report No. 501-9923/04-CE

TEST REPORT NO. 501-9923/04-CE 16.01.2015

Designation of sample : BIGUMA- TL 82 COLZUMIX-Haftgrund


Joint sealant Primer

Type of joint sealant : Hot applied joint sealant based on bitumen, in accordance
to DIN EN 14188-1: 2004, type N2

Manufactured by : Dortmunder Guasphalt GmbH & Co. KG


Auf dem Brmmer 20
D-44149 Dortmund
Germany

Date of sampling : 24.11.2014

Specification requirements : Initial type testing in accordance to DIN EN 14188-1: 2004,


annex A, table A.1, type N2

Weight of sample : approx. 10 kg approx. 500 ml


in sheet metal container in firmly closed glass
bottle

Order date : 24.11.2014

Dortmunder Guasphalt GmbH & Co. KG, Teinenkamp 43, D-59494 Soest,Phone ++49 2921-89070, Fax ++49 2921-890770
Page 2 of 3 to Test Report No. 501-9923/04-CE dated 16.01.2015

Properties Unit BIGUMA- TL 82 Requirements Standard


DIN EN 14188-1
type N2
1. Appearance and nature mainly plastic, homo- - DIN EN
genous 13880-6

2. Softening point ring & ball C 91,0 85 DIN EN 1427

3. Density at 25C Mg/m 1,132 - DIN EN


13880-1

4. Cone penetration at 25C, 5 s, 150 g 0,1 mm 62 40 - 100 DIN EN


(70C,7 d) at 25 C 13880-2

5. Penetration and recovery (resilience) at 25C, % 48 60 DIN EN


5 s, 75 g 13880-3

6. Heat resistance change in penetration value DIN EN


at 70C / 168 h 13880-4
6.1 Cone penetration 0,1 mm 60 40 100
6.2 Penetration and recovery (resilience) % 49 60

7. Flow resistance DIN EN


7.1 Initial mm 0,4 3 13880-5
7.2 After heat exposure mm 0,4 3

8. Compatibility with asphalt pavements no failure in adhesion, no failure in adhesion, DIN EN


no exudation of oil no exudation of oil 13880-9

9. Adherence test (discontimous extension) before after before after DIN EN


at -20C water immersion water immersion 13880-13
9.1 Total extension mm 5 5 5 5
9.2 Tensile stresses
- maximum N/mm 0,27 0,28 0,75 0,75
- end of test N/mm 0,06 0,06 - -
9.3 Failure in adhesion
- complete failure mm None none
- crack depth mm None none
9.4 Failure in cohesion
- total amount of cracks mm None none
- crack depth mm None none

10. Adhesion and cohesion following continuous DIN EN


extension and compression at 0C 13880-10
10.1 Maximum tensile stress N/mm 0,09 0,48
10.2 Adhesion
- complete failure in adhesion mm 0 < 50
- crack depth mm 0 <3
10.3 Cohesion
- total amount of cracks mm 0 < 20
- crack depth mm 0 <3

Dortmunder Guasphalt GmbH & Co. KG, Teinenkamp 43, D-59494 Soest,Phone ++49 2921-89070, Fax ++49 2921-890770
Page 3 of 3 to Test Report No. 501-9923/04-CE dated 16.01.2015

Conclusion

The sample submitted of a hot applied joint sealant bearing the designation

BIGUMA-TL 82

satisfies on its own and in model joint when simultaneously using the primer COLZUMIX-
Haftgrund all specification requirements according to DIN EN 14188-1: 2004, type N2.

It is recommended to choose a processing temperature between 160 and 180C.


The safe heating temperature in accordance with DIN EN 14188-1: 2004 no. 3.7 is 190C.

i.V. Ch. Schmidt

Dortmunder Guasphalt GmbH & Co. KG, Teinenkamp 43, D-59494 Soest,Phone ++49 2921-89070, Fax ++49 2921-890770