Sie sind auf Seite 1von 80

PRODUCT CATALOG

A DIVISION OF NSi INDUSTRIES, LLC


2011
USA 800.321.5847 www.nsiindustries.com
responsible
energy A DIVISION OF NSi INDUSTRIES, LLC
NSi Industries LLC

About Us
Since 1975, NSis strength is in the unique products that we bring to
the market, combined with our exceptional ability to provide quality
TORK brand products manufactured in the companys Mount Vernon
facility. TORK is NSi Industries largest brand, covering the categories of
Electromechanical and Digital Time Switches, Signaling and Alert Devices,
Pool and Spa Controls, Residential Timers, Photocontrols and Occupancy
Sensors.
For over 85 years, TORK brand recognition and reputation for quality and
design make it the most specified brand in the industry. The TORK brand
has a rich history beginning in the 1920s when the company introduced
the first electromechanical time switch to the marketplace. Currently, TORKs
time switches maintain energy efficiency through lighting control in such
high profile places as the Empire State Building, Washington DC Parks and
Recreation, The Triborough Bridge, The Met Life Building and many more
institutions across the country. As the most specified brand of time switches in the
industry, TORK enjoys the hearty respect of engineers and project planners
across all channels of distribution.
In the past several years, weve introduced a number of TORK time
switches, in-wall and plug-in timers to meet increasingly specific needs in
the marketplace. Weve also added a line of installer-friendly pool and
spa panels and time switches, and are proud to offer essential pool safety
products that meet and exceed federal requirements for safe pools. We
look forward to designing and engineering more of our Responsible Energy
products, helping save money and the environment through responsible and
minimal use of energy.
TABLE OF CONTENTS TABLE OF CONTENTS

ENERGY CODE REFERENCE GUIDE . . . . . . . . . . . . . 7 DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 WARNING LIGHTS, INDUSTRIAL . . . . . . . . . . . . . 135
PHOTOCONTROLS E SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 WARNING LIGHTS, VEHICULAR . . . . . . . . . . . . . . 136
QUICK LOOK FEATURES & COMMON FEATURES . . . 11 E-PB SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 C SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 POWER SUPPLY UNITS . . . . . . . . . . . . . . . . . . . . 137
2100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 EW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 OCCUPANCY SENSORS TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . 137
2110 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 EWZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 SENSOR TECHNOLOGY & PLACEMENT GUIDE . . . . 109 ACCESSORIES/REPLACEMENT PARTS/DIMENSIONS 138
2000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 DG100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 OSWS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 110 POOL & SPA
2001 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 DZS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 PP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . . 141
2020 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 DTS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 PFP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . 143
3000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 DW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 1100 SERIES TIMERS . . . . . . . . . . . . . . . . . . . . . 144
5000M SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 DZM SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 OSC20UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 DW200B TIMER . . . . . . . . . . . . . . . . . . . . . . . . . 145
2005A, 2007A, 2008A SERIES . . . . . . . . . . . . . . . 20 ELC SERIES, 1 & 2 ZONE . . . . . . . . . . . . . . . . . . . 73 OSC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 P1100 SERIES, 24 HOUR
5200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 ELC SERIES, 4, 8 &12 ZONE . . . . . . . . . . . . . . . . . 75 ELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 ELECTROMECHANICAL MECHANISMS . . . . . . . . . . 147
5400 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 LC200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 TRP-U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 P1100 SERIES, 7 DAY DIGITAL MECHANISMS . . . 148
5737 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 DGU SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 PLUG-IN TIMERS JUNCTION BOXES . . . . . . . . . . . . . . . . . . . . . . . 148
PHOTOCONTROL ACCESSORIES . . . . . . . . . . . . . . . 24 DGLC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 STINGL SR-500 & SR-500PS, SVRS . . . . . . . . . . 149
400A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
ELECTROMECHANICAL DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 LAYERS OF PROTECTION . . . . . . . . . . . . . . . . . . . 150
400D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
LD SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 ANTI-ENTRAPMENT DRAIN COVERS . . . . . . . . . . . 151
QUICK LOOK FEATURES & COMMON FEATURES . . . 27 600A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
DGS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 MAGNALATCH SELF-LATCHING GATE CLOSURES . . 152
TU40 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 600D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
EJWT & E500T SERIES . . . . . . . . . . . . . . . . . . . . . 87 TRUCLOSE SELF-CLOSING GATE HINGES . . . . . . . .152
1100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
DIN SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 POOL&SPA SAFETY ACCESSORIES . . . . . . . . . . . . 152
7000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 TORK ALERT
SMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
7000Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 MECHANICAL STROBE HORNS . . . . . . . . . . . . . . . 127
5401 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 ENCLOSURE DIMENSIONS . . . . . . . . . . . . . . . . . . 153
8000 SERIES, DUTY CYCLE . . . . . . . . . . . . . . . . . . 37 MECHANICAL HORNS . . . . . . . . . . . . . . . . . . . . . 127
HPS STARTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 ALPHANUMERIC INDEX . . . . . . . . . . . . . . . . . . . 155
8000 SERIES, REPEATING VARIABLE CYCLE . . . . . . 39 MULTI-TONE ELECTRONIC HORNS . . . . . . . . . . . . 128
TRP SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
WH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 HEAVY DUTY BELLS . . . . . . . . . . . . . . . . . . . . . . 128
DIGITAL ENCLOSURES & DIMENSIONS . . . . . . . . . 153
1800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 BELLS & BUZZERS . . . . . . . . . . . . . . . . . . . . . . . 129
IN-WALL TIMERS
W SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 CHIMES & CHIME KITS . . . . . . . . . . . . . . . . . . . . 129
T900 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 97
WEATHERPROOF MOTOR DRIVEN SIREN . . . . . . . 130
TW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 SS720A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 98
MANUAL FIRE ALARM . . . . . . . . . . . . . . . . . . . . 130
TZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 SS700Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TELEPHONE STROBE . . . . . . . . . . . . . . . . . . . . . . 131
ELECTROMECHANICAL ENCLOSURES SS721Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TELEPHONE HORN . . . . . . . . . . . . . . . . . . . . . . . 131
& DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 153 701A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
TELEPHONE RELAY . . . . . . . . . . . . . . . . . . . . . . . 132
DIGITAL 711A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
WALL CLOCKS . . . . . . . . . . . . . . . . . . . . . . . . . . 132
SSA SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 53 ELECTRIC DOOR OPENERS . . . . . . . . . . . . . . . . . 133
SS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 PUSH-BUTTONS . . . . . . . . . . . . . . . . . . . . . . . . . 134
N
LA
ENERGY CODE INTERIOR LIGHTING ZONES

L&
U RA
REFERENCE GUIDE

CT
The first way to save energy begins with eliminating lighting when it isn't needed.

ITE
energy As with exterior lighting, an efficient design matches controls to the typical use of the

CH
energy
saving saving area.

AR
solutions solutions

< Responsible Energy is the mark


of TORKs commitment to developing Responsible Energy ZONE 1: SMALL SPACE
and manufacturing energy saving, Each of these marked products have features that decrease Small Space, Meeting Rooms, Restrooms, Storage Spaces: Occupancy Sensors, Interval Timers
energy consumption and/or damage to the environment by one
environmentally friendly products.

ES
or more of the following: The first zone includes small spaces such as offices, restrooms and storage areas -

FIC
Timed control, Photocontrol and/or Astronomic control of on
energy and off functions of lighting, fans, pumps and appliances 
responsible places where people may not occupy the space continuously. Individual wall switch

OF
energy
responsible

replacement provides low cost installation, with occupancy sensors and interval timers

ES
Timed control of systems or multiple zones of lighting

FIC
Photo or occupancy sensing control of lighting
as the best solution. In the event that wall switches provide proper coverage for the

OF
Supercapacitor backup, no batteries to replace or dispose. occupancy sensor, ceiling mounted options are available.

N
TIO
Helps meet CA Title 24, ASHRAE , IECC and other

P
< Use the Quick Reference Energy standards for responsible building products ZONE 2: LARGE SPACE

CE
Code Guide for approved products.

RE
responsible
energy Small Space, Meeting Rooms, Restrooms, Storage Spaces: Time of Day with Override,
Occupancy Sensors
CALIFORNIA Title 24

ASHRAE 90.1
The first zone includes small spaces such as offices, restrooms and storage areas -
T

places where people may not occupy the space continuously. Individual wall switch
LO

replacement provides low cost installation, with occupancy sensors and interval
G
KIN

OM K
timers as the best solution. In the event that wall switches provide proper coverage

RO REA
R

for the occupancy sensor, ceiling mounted options are available.

OM
PA

B
EXTERIOR LIGHTING ZONES

RO
T
ON

ZONE 3: HARVESTING LIGHT

CE
FR

When ambient light levels drop at dusk, lighting is needed to provide safety and

EN
Large of Small Spaces with Natural Light: Light Sensors, Light Sensors with Occupancy,

ER
security. BUT: Does all lighting need to be on all night long? The proper selection NF Astronomic Timers.
of lighting controls is essential to ensuring that energy is only used when needed.
CO
A third zone that uses daylighting control can be added to wither of the first two

M
An efficient lighting control design creates zones of light levels that can be varied zones. light sensors can shut off a portion of the lighting when windows or skylights

O
RO
by time at night. contribute sufficient natural light to the area. This "harvesting" of light is an

ST

E
FIC
RE
excellent, green way to conserve energy. (NOTE: Energy codes vary on the stated

OF
maximum time, but shorter times can give more energy savings).
M
O
RO

ZONE 1: MINIMUM LIGHT LEVEL / DUSK TO DAWN


SE
OU

ST

E
FIC
RE

Security Lighting (all night): Photocontrols, Photosensor controls


EH

OF
R

E
The first zone gives a minimum light level where security is the primary
WA

FIC
need. Determine what lighting is necessary, such as building-mounted

OF
wallpacks and a portion of the parking lot lighting. These should be on
from dusk to dawn, and are best controlled by a photosensor device.

ZONE 2: HIGHER LIGHT LEVEL / DUSK TO TIME OFF FRONT PARKING LOT

Safety & Architectural Lighting (not necessary all night): Photosensor/Time-


based controls, Astronomic controls ARCHITECTURAL & LANDSCAPING

The second zone provides a higher light level for safety, when people DOCKS & BACK
PARKING
are normally present. Maximum levels for the parking lot and all walk- LOT
way lighting are needed. These lights are best controlled by a com-
bination photosensor and time-based device to allow shut-off during RECEPTION
the night. The astronomic-calculated sunset/time control can also be CONFERENCE ROOM
useful. OFFICES
WAREHOUSE
OFFICES

ZONE 3: ARCHITECTURAL / TIMED DUSK TO TIMED OFF


RESTROOM RESTROOM

Building Facade, Landscape and Signage: Astronomic controls


The third zone covers architectural lighting for building facade or land- OFFICE
scape and signs. These are best controlled with an astronomic-calculated OFFICE
sunset/time control. BREAK
OFFICE ROOM

TORK 7 TORK 8
PHOTOCONTROLS
FEATURES
QUICK LOOK
COMMON FEATURES
CHOICE OF PHOTOCELLS
Cadmium sulphide, epoxy-
sealed cells. Available in 12
and 1".

2100 2110 2000 2001 2020 3000 5000M 2005A 5200 5737
SERIES SERIES SERIES SERIES SERIES SERIES SERIES SERIES SERIES SERIES

Page 13 14 15 16 17 18 19 20 21 23
TOUGH ENCLOSURES CHOICE OF MOUNTING
Mounting Conduit Conduit Conduit Conduit Conduit Flush Turn-Lock Turn-Lock Turn-Lock Turn-Lock
All conduit and flush mounted
ORIENTATION
Adjustable Swivel Yes Yes models utilize die-cast zinc, Models are available in fixed
Die Cast UV Stabilized UV Stabilized UV Stabilized UV Stabilized die cast aluminum, or genuine position or 180 swivel.
Housing Die Cast Zinc Aluminum Lexan Lexan Lexan Lexan
Plastic Plastic Plastic Plastic Lexan materials. All turn-lock
models utilize high impact UV
Turn ON Light Level 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 - 5 fc 1 to 3 fc 1 to 3 fc 1.5 fc 5 fc
stabilized polypropylene, ABS,
Adjustable light level PBT or Lexan materials.
Yes Yes Yes Yes
adjustment
Turn OFF Ratio 3:1 3:1 3:1 3:1 3:1 3:1 5:1 3:1 1.5:1 1.5:1

Time Delay ON Yes Yes Yes Yes Yes Yes Yes Instant Instant Instant DEPENDABLE performance
Time Delay OFF Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Built-in time delay prevents false
switching due to light from passing
Light Sensor CdS CdS CdS CdS CdS CdS CdS CdS Silicon Diode Silicon Diode highway vehicles, lightning, etc.
Instant response is available in
CFL Compatible Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes turn-lock models (5200 Series).

Surge Protection Yes Yes Yes Yes

Photo Timer Yes TURN-LOCKS MEET ANSI C136.10


All models meet the current ANSI
requirements for locking-type
prongs and color coded voltage
designations. Locking prongs are
solid brass.
Color-Coded Dome
Grey 105-130VAC
Maroon 208-277VAC
Blue 105-285VAC
Yellow 480VAC
Green 347VAC
TORK Photocontrols are
designed and manufactured with
components which adhere to
the highest industry standards.
Trained personnel and in-process
quality procedures ensure that
every unit meets our strictest
quality standards.

TORK 11 TORK 12
2100 SERIES SPECIFICATIONS 2110 SERIES SPECIFICATIONS
SPECIFICATION GRADE SPECIFICATION GRADE
1/2" CONDUIT MOUNTING ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 1/2" CONDUIT MOUNTING ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3
to 15fc, without the slide in position. ON/OFF to 15fc, without the slide in position. ON/OFF
DIE CAST ZINC DIE CAST ALUMINUM
adjustment is easily made by moving a slide adjustment is easily made by moving a slide
PHOTOCONTROL cover. No tools required. PHOTOCONTROL cover. No tools required.
TIME DELAY: ON and OFF. TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated, 1" CELL: Cadmium sulphide, epoxy-coated, 12
APPLICATIONS diameter. APPLICATIONS diameter. Model 2117 is 1" cell.
CONTACTS: Remain closed between dusk and 2117 CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position). dawn (the unit fails in the ON position).
Parking lot lighting Parking lot lighting
Building perimeter lighting LEAD WIRES: Three color coded, minimum Building perimeter lighting 2115 & 2116
LEAD WIRES: Three color coded, minimum
Outdoor signage 6 wire leads, #16AWG, rated for 105C. Outdoor signage 6 wire leads, #16AWG, rated for 105C. (2117
#10AWG red and black).
POWER CONSUMPTION:
Averages under 1 watt. POWER CONSUMPTION:
Averages under 1 watt.
TEMPERATURE RANGE:
-40 to +140F (-40 to +60C). TEMPERATURE RANGE:
-40 to +140F (-40 to +60C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS
CATALOG RATING CONTACT RATINGS
WIRING
NO. DIAGRAMS
SWITCH
TUNGSTEN BALLAST CATALOG RATING
SWITCH
NO. TUNGSTEN BALLAST
FEATURES 2101 SPST 2000W 1800VA FEATURES
2115 SPST 2000W 1800VA
2104 SPST 2000W 1800VA
OPERATION: Delay of up to two minutes OPERATION: Delay of up to two minutes
to prevent false switching due to light from to prevent false switching due to light from 2116 SPST 3470-4620W 2080-2770VA
2107 SPST 2000W 1800W
passing vehicles, lightning, etc. passing vehicles, lightning, etc.
2117* SPST 3000W 3000VA
HOUSING: Heavy Duty die cast zinc 2000 SERIES 2100 SERIESDie case aluminum housing
HOUSING:
WIRING DIAGRAMS
housing and base. Gasketed for maximum and base. Gasketed for weather protection.
weather protection. 2000 SERIES 2100 WIRING
SERIES DIAGRAMS
ENERGY SAVINGS: Works with screw
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
base CFLs and LED lamps.

ORDERING INFO
ORDERING INFO
CATALOG UPC VOLTAGE
CATALOG UPC VOLTAGE NO. CODE 50-60Hz
NO. CODE 50-60Hz
2115 60032 120VAC
2101 60012 120VAC
2116 60033 208-277VAC
2104 60013 208-277VAC
2117* 60037 120VAC
2107 60031 120/277VAC
73866 62020 Mounting Bracket
73866 62020 Mounting Bracket
*Not UL or CSA rated.

PHOTOCONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 13 USA 800.321.5847 www.nsiindustries.com TORK 14
2000 SERIES SPECIFICATIONS 2001 SERIES SPECIFICATIONS
1/2" CONDUIT MOUNTING 1/2" CONDUIT MOUNTING
FIXED POSITION, LEXANHOUSING ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 180 SWIVEL, LEXANHOUSING ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3
to 15fc, without the slide in position. ON/OFF to 15fc, without the slide in position. ON/OFF
WITH WEATHERPROOF SEALANT PHOTOCONTROL
adjustment is easily made by moving a slide adjustment is easily made by moving a slide
PHOTOCONTROL cover. No tools required. cover. No tools required.
TIME DELAY: ON and OFF. TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated, 12 CELL: Cadmium sulphide, epoxy-coated, 12
APPLICATIONS diameter. APPLICATIONS diameter.
CONTACTS: Remain closed between dusk and CONTACTS: Remain closed between dusk and
dawn. (The unit fails in the ON position). dawn. (The unit fails in the ON position).
Flood lamp Flood lamp
Patio lamp LEAD WIRES: Three color coded, minimum Patio lamp LEAD WIRES: Three color coded, minimum
Decorative lighting 6 wire leads, #16AWG, rated for 105C. Decorative lighting 6 wire leads, #16AWG, rated for 105C.
POWER CONSUMPTION: POWER CONSUMPTION:
Averages under 1 watt. Averages under 1 watt.
TEMPERATURE RANGE: TEMPERATURE RANGE:
-40 to +140F (-40 to +60C). -40 to +140F (-40 to +60C).
FAIL MODE: ON. FAIL MODE: ON.
WARRANTY: 5 years. WARRANTY: 5 years.

CONTACT RATINGS
WIRING DIAGRAMS
CATALOG RATING
SWITCH CONTACT RATINGS
NO. TUNGSTEN BALLAST
CATALOG RATING
FEATURES 2000 SPST 2000W 1800VA FEATURES NO.
SWITCH
TUNGSTEN BALLAST

OPERATION: Delay up to two minutes to 2000-2 SPST 3470-4620W 2080-2770VA 2001 SPST 2000W 1800VA
OPERATION: Delay up to two minutes to
prevent false switching due to light from prevent false switching due to light from
passing vehicles, lightning, etc. 2000-7* SPST 2000W 1800VA 2002 SPST 3470-4620W 2080-2770VA
passing vehicles, lightning, etc.
HOUSING: All Lexan enclosures are HOUSING: All Lexan enclosures are
impact and vandal resistant. Translucent WIRING DIAGRAMS impact and vandal resistant. Translucent WIRING DIAGRAMS
Lexan Dome prolongs cell life by further Lexan Dome prolongs cell life by further
screening out ultraviolet rays. Dome 2000 SERIES 2100 SERIES
screening out ultraviolet rays. Dome
and base are ultrasonically welded for and base are ultrasonically welded for
maximum strength. maximum strength.
Move Slide for Earlier
ENERGY SAVINGS: Works with screw ENERGY SAVINGS: Works with screw or Later Turn ON

base CFLs and LED lamps. base CFLs and LED lamps.
Black Line Red Lamp

ORDERING INFO ORDERING INFO
White Neutral

CATALOG UPC VOLTAGE CATALOG UPC VOLTAGE
NO. CODE 50-60Hz NO. CODE 50-60Hz

2000 60017 120 2001 60015 120

2000-2 60018 208-277 2002 60016 208-277 Move Slide for Earlier
or Later Turn ON

2000-7* 62023 120/277 73866 62020 Mounting Bracket


(Black) Line (Red) Lamp For 277VAC:
73866 62020 Mounting Bracket L1 240V (White)
L1 - Line
L2 L2 - Neutral
*Model 2000-7 has a cadmium sulphide, 1 epoxy cell. Also
UL listed and CSA certified.

PHOTOCONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 15 USA 800.321.5847 www.nsiindustries.com TORK 16
2020 SERIES SPECIFICATIONS 3000 SERIES SPECIFICATIONS
1/2" CONDUIT MOUNTING FLUSH MOUNTING
180 SWIVEL, LEXANHOUSING ON/OFF: Turn ON is 1 to 5fc. Turn OFF is LEXANHOUSING ON/OFF: Turn ON is 1 to 5fc. Turn OFF is
PHOTOCONTROL 3 to 15fc. PHOTOCONTROL 3 to 15fc.
TIME DELAY: ON and OFF. TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated, CELL: Cadmium sulphide, epoxy-coated,
12 diameter. 12 diameter.

APPLICATIONS CONTACTS: Normally closed (the unit APPLICATIONS CONTACTS: Normally closed (the unit
fails in the ON position). fails in the ON position).
Flush Mounting
LEAD WIRES: Three color coded, Model 3010
LEAD WIRES: Three color coded,
Flood and patio lamps minimum 6 wire leads, #16AWG, rated Pole lanterns minimum 6 wire leads, #16AWG, rated
Decorative lighting for 105C. Lawn lighting for 105C.
Walkways
POWER CONSUMPTION: POWER CONSUMPTION:
Ideal for applications where it
Averages under 1 watt. Averages under 1 watt.
is essential to aim the photocell
in an exact direction to sense TEMPERATURE RANGE: TEMPERATURE RANGE:
natural light but avoid artificial -40 to +140F (-40 to +60C). -40 to +140F (-40 to +60C).
light. FAIL MODE: ON. FAIL MODE: ON.
WARRANTY: 5 years. WARRANTY: 5 years.

CONTACT RATINGS
CATALOG RATING
SWITCH
WIRING
NO. DIAGRAMS
TUNGSTEN BALLAST
CONTACT RATINGS
3000 SPST 2000W 1800VA
FEATURES CATALOG RATING FEATURES
SWITCH
NO. TUNGSTEN BALLAST
3002 SPST 3470-4620W 2080-2770VA
OPERATION: Delay up to two minutes to OPERATION: Delay up to two minutes to
2021 SPST 2000W 1800VA
prevent false switching due to light from prevent false switching due to light from passing 3006* SPST 1500W 1200VA
passing vehicles, lightning, etc. 2022 SPST 3470-4620W 2080-2770VA vehicles, lightning, etc.
3010 SPST 2000W 1800VA
HOUSING: All Lexan enclosures are HOUSING & MOUNTING: Control housing
impact and vandal resistant, cover and base is weather-resistant molded Lexan with
are ultrasonically welded for maximum WIRING DIAGRAMS ultrasonically welded seams. WIRING DIAGRAMS
strength. MODEL 3000: Flush mounting through .6875
ENERGY SAVINGS: Works with screw hole in post lantern or lighting fixture, 38 NPT, 120V
base CFLs and LED lamps. 120V stem 34 long. Gasket and nut supplied. MODEL
MODELS
MODEL 3010: flush mounting into standard,
raintight junction box. Includes plate and gasket LAMP
ORDERING INFO
Line (Black) (Red) Lamp to fit FS type outdoor junction box.
CATALOG UPC VOLTAGE Neutral (White) LINE BLK RED
NO. CODE 50-60Hz ENERGY SAVINGS: Works with screw base
120V
CFLs and LED lamps. NEUT. WHITE
2021 60024 120
208-277V
MODELS ORDERING INFO
2022 60025 208-277
CATALOG UPC VOLTAGE
NO. CODE 50-60Hz 208-277V
73866 62020 Mounting Bracket MODEL
Line (Black) (Red) Lamp
L1
3000 60020 120
For 277VAC:
240V
L1 - Line
Neutral (White) 3002 60019 208-277 LAMP
L2 L2 - Neutral
For 277VAC
L1 - Line 3006* 60026 347 LINE BLK RED
L2 - Neutral
240V
3010 60021 120 WHITE

*CSA certified only.

PHOTOCONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 17 USA 800.321.5847 www.nsiindustries.com TORK 18
5000M SERIES SPECIFICATIONS 2005A, 2007A SPECIFICATIONS
DELAYED RESPONSE UTILITY GRADE
MOV SURGE ARRESTOR
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON & 2008A ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-
ratio is 5 max. QUICK RESPONSE ON is 3 average.
PHOTOCONTROL
TIME DELAY: ON and OFF. TURN-LOCK MOUNTING TIME DELAY: Instant ON/3-5 seconds OFF.
CELL: Cadmium sulphide photocell responds to the PHOTOCONTROL
CELL: Cadmium sulphide photocell responds to the
light spectrum near to that of a human eye. Resists light spectrum near to that of a human eye. Resists
effects of moisture and airborne contaminants. effects of moisture and airborne contaminants.
APPLICATIONS RELAY: Bi-metal provides positive snap action APPLICATIONS CONTACTS: Solid brass prongs for maximum
switching, reducing bounce and prolonging contact life. corrosion resistance and electrical conductivity.
For use on streets, highways and SURGE ARRESTOR: 380 joule MOV (metal oxide
For use on streets, highways and
other luminaries equipped with other luminaries equipped with SURGE ARRESTOR: 360 joules MOV exceeds
varistor) exceeds ANSI and NEMA requirements. NEMA and ANSI requirements.
locking type receptacles, where locking type receptacles, where
most stringent surge protection LOCKING PRONGS: Solid brass for maximum instant response is required. RELAY: Positive snap action switching, reducing
corrosion resistance and electrical conductivity. bounce and prolonging contact life.
is needed.
TEMPERATURE RANGE: Complies with ANSI C136.10 and TEMPERATURE RANGE:
-40 to +140F (-40 to +60C). EEI NEMA standards. -40 to +158F (-40 to +70C).
FAIL MODE: ON. FAIL MODE: ON.
WARRANTY: 3 years. WARRANTY: 3 years.

FEATURES CONTACT RATINGS


CATALOG RATING
LIGHT SENSOR FEATURES
OPERATION: Delayed response prevents false NO. TUNGSTEN BALLAST
switching due to light from vehicles or lighting, etc.
5001M 1" 1200W 1800VA STANDARDS: Meets ANSI C136.10
STANDARDS: Meets ANSI C136.10 including color including color designations. Also meets
designations. Also meets EEI NEMA standards. 5004M 1" 3470-4620W 2080-2770VA EEI NEMA standards.
CONTACT RATINGS
HOUSING: Lexan UV Stabilized, permanent color 12" 2000W 1800VA HOUSING: Polypropylene, UV
5007M CATALOG RATING
with UV resistant clear acrylic window. Models 5026M 3470-4620W 2080-2770VA
Stabilized, permanent color with UV NO. TUNGSTEN BALLAST
and 5008M with polypropylene dome. Provides high 5008M* 1" 1000W 1800VA resistant clear acrylic window. Provides
impact, flammability resistance and electrically safe high impact, flammability resistance and 2005A 1000W 1800VA
operation. 5021M 12" 2000W 1800VA electrically safe operation.
2007A 1000W 1800VA
ENERGY SAVINGS: Works with screw base CFLs 5024M 12" 3470-4620W 2080-2770VA ENERGY SAVINGS: Works with screw
and LED lamps. base CFLs and LED lamps. 2008A* 1000W 1800VA
5026M** 12" 1000W 1800VA
ORDERING INFO
CATALOG UPC VOLTAGE WIRING DIAGRAMS ORDERING INFO WIRING DIAGRAMS
NO. CODE 50-60Hz COLOR
CATALOG UPC VOLTAGE COLOR
5001M 61012 105-130 Grey NO. CODE 50-60Hz

2" 2005A 62012 105-130 Grey 2"


5004M 61013 208-277 Maroon 2 3/16" 2 3/16"

Receptacle Surface 2007A 62013 105-285 Blue Receptacle Surface


5007M 61014 105-130/208-285 Blue

2 3/16"
2008A* 62014 400-550 Yellow
5008M* 61017 480 Yellow 3 3/16"

*Not UL or CSA listed.


5021M 61015 105-130 Grey

5024M 61016 208-277 Maroon N L1


Line N L1
(Black) Load (Red) Line
5026M** 61045 347 Green Neutral
105 to 285 volt (Black) Load (Red)
Load single phase grounded 105 to 285 volt
(White) supplies and loads Neutral Load single phase grounded
*Not UL listed or CSA certified. (White) supplies and loads
**CSA certified only.

PHOTOCONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 19 USA 800.321.5847 www.nsiindustries.com TORK 20
5200 SERIES SPECIFICATIONS 5400 SERIES SPECIFICATIONS
UTILITY GRADE ELECTRONIC 6000 WATT CONTACTORS
WITH FAIL ON MODE ON/OFF: Turn ON is 1.5 foot candle +/- 0.2 OFF/ON WITH TURN-LOCK RECEPTACLE: 3-prong turn-lock meets the
requirements of EEI NEMA.
PHOTOCONTROL ratio is 1.5:1 average*. PHOTOCONTROL
TIME DELAY: Instant ON/3-5 second OFF*. POWER CONSUMPTION: Maximum 3 watts
during daylight.
CELL: Silicon photosensor assures drift-free operation,
turning on and off at the same light level consistently
throughout the life of the unit.
APPLICATIONS APPLICATIONS
CONTACTS: DC relay has positive snap action switching,
reducing bounce and prolonging contact life. Fail ON for CONTACT RATINGS
For use where the extreme safety. For street lighting. Controls all CATALOG CONTACT RATING
accuracy and reliability of lighting loads in excess of the SWITCH
NO. PER POLE
SURGE ARRESTOR: 920 joule MOV (metal oxide
an electronic photocontrol is capacity of the photoelectric
varistor) exceeds ANSI and NEMA requirements. 5403 DPST 3000W
required and in the event of control contacts.
failure, light should stay ON for LOCKING PRONGS: Solid brass for maximum corrosion
5404 DPST 3000W
safety reasons. resistance and electrical conductivity.
POWER CONSUMPTION: 1.0 watt average @ 120V. 5404-3 DPST 3000W

TEMPERATURE RANGE: 5420 SPDT 3000W


-40 to +158F (-40 to +70C).
FAIL MODE: ON.
WARRANTY: 5 years. WIRING DIAGRAMS
*Consult factory for other ratios and time delays. 120 VOLT CIRCUIT
MODEL
5403 WHT BLK RED WHT BLK RED
WHT

FEATURES FEATURES
LOAD LOAD LOAD LOAD

STANDARDS: Meets ANSI C136.10 CONTACT RATINGS HOUSING: Outdoor NEMA Type 3R. Beige
WHT WHT

WHT
H H

including color designations. Also meets EEI enamel finish. Two 12 34 combination N
120V
N
120V
H

CATALOG RATING 277V

NEMA standards.
H 120V

KO in bottom.
N

LIGHT SENSOR
NO. TUNGSTEN BALLAST
120V 2-WIRE SYSTEM 120V/240V 3-WIRE SYSTEM 277V/48

HOUSING: UV stabilized, ANSI color- ENERGY SAVINGS: Works with screw CAS
120 VOLT CIRCUIT
coded, high impact polypropylene dome. 5231 Silicon Photosensor 1000W 1800VA base CFLs and LED lamps. MODEL WHT
DIMENS
5420 RED
Cross-linked polypropylene gasket. High BLK

impact ABS base. High impact, UV stabilized 5237 Silicon Photosensor 1000W 1800VA
ORDERING INFO RED LOAD 1

acrylic window. N BLUE LOAD 2


WHT
H 120V
CATALOG UPC PHOTOCONTROL VOLTAGE BLK

ENERGY SAVINGS: Works with screw WIRING DIAGRAMS NO. CODE INCLUDED 50-60Hz
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN
base CFLs and LED lamps. 5403 60009 5021M 105-130VAC
LOAD 2 CLOSES AT DAWN, OPENS AT DUSK

120 VOLT CIRCUIT 277 VOLT CIRCUIT 208 or 240 VOLT


5404 60010 MODEL 5024M 208-240VAC MODEL CIRCUIT
5403 WHT BLK RED WHT BLK RED 5404-3 MODEL 5404
WHT BLK RED
WHT BLK RED
N L1
2" Line 5404-3 60011 5024M 277VAC
2 3/16"
(Black) Load (Red)

ORDERING INFO
LOAD LOAD LOAD LOAD
Receptacle Surface Neutral Load LOAD

5420 60014 5021M 105-130VAC


LOAD LOAD
(White) WHT WHT
WHT
WHT

CATALOG UPC VOLTAGE 105-305 VAC


H
120V
H
120V H
NO. CODE 50-60Hz 3 1/8" single phase grounded supplies and loads N N H
277V 208V or 240V
H 120V N H

120V 2-WIRE SYSTEM 120V/240V 3-WIRE SYSTEM 277V/480V 4-WIRE SYSTEM 208V/240V 4-WIRE SYSTEM
5231 78885 105-130VAC
CASE Add photoelectric control dimensions
120 VOLT CIRCUIT 2" high x 3" diameter
5237 78886 105-305VAC MODEL WHT
DIMENSIONS
5420 RED
BLK
N L1
RED LOAD 1
Line

(184mm)
7-1/4"
(Black) Load (Red) N BLUE LOAD 2

105 to 285 volt H 120V


WHT 4-1/2" 3-13/32"
Neutral Load single phase grounded BLK (114mm) (87mm)
(White) supplies and loads
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN
LOAD 2 CLOSES AT DAWN, OPENS AT DUSK

PHOTOCONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 21 USA 800.321.5847 www.nsiindustries.com TORK 22
5737 SERIES
ON AT DUSK, OFF AT MIDNIGHT
SPECIFICATIONS
TORK 5737 T Z PHOTO-TIMER

ON EARLY MORNING, ON/OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5 OFF/
OFF AT DAWN ON ratio is 1.5:1 average. THEMOSTFLEXIBLEPHOTO-TIMER FOR MAXIMUM
PHOTO-TIMERS TIME DELAY: Instant ON/3-5 seconds OFF. ENERGY SAVINGS AND ALL ON/OFF NEEDS!
CELL: Silicon photosensor DUSK
Midnight OFF: Allows user to adjust OFF time during the The TORK Photo-timer Plus is the most flexible photocontrol ever, MIDNIGHTON
night. OFF time can be set for up to two hours before (for operating like a photocontrol ANDa time switch! Ideal for retrofit without EARLYMO OFF
APPLICATIONS extra energy savings) or up to two hours after midnight. RNINGON
expensive rewiring. The unit turns the load ON at sunset and can be preset DAWNOFF
Use to stagger groups of lights to go OFF at different times to turn the load OFF up to two hours before or two hours after midnight.
during the night. It can also be set to turn the load back ON from two to ten hours after
Offices
Early Morning ON (537TZ only): Allows user to set number midnight and OFF at dawn.
Restaurant signage
of hours after midnight (from 2-10 hours) that lights
Billboards
should turn back ON. No programming is required, the microprocessor tracks dusk and dawn
Landscape and yard lighting
CONTACTS: DC Relay, normally closed. Provides chatter times and automatically determines midnight, and corrects for Daylight
Ideal for situations when visible free operation. Solid brass Prongs for maximum corrosion Savings Time. It even re-learns and resets itself after a power outage, so that
traffic is reduced lights ON at resistance and electrical conductivity. no maintenance is ever needed.
dusk and OFF at 11pm or later, TEMPERATURE RANGE:
then on again for early morning -40 to +158F (-40 to +70C).
illumination. FAIL MODE: ON.
WARRANTY: 3 years.

PHOTOCONTROL
ACCESSORIES
FEATURES FOR TURN-LOCK CONTROLS

OPERATION: Microprocessor tracks the


dusk and dawn times with the seasons and CONTACT RATINGS
automatically determines midnight, NO CATALOG RATING REPLACEMENT CAPS
SWITCH 5500 replaces photocontrol to change light fixture to always ON. 5500-OC RECEPTACLE
PROGRAMMING REQUIRED. Automatically NO. TUNGSTEN BALLAST
replaces photocontrol to change light fixture to always OFF. Durable materials 120-480V receptacle with color-coded #14 leads, neoprene gasket and two
"re-learns" and resets after power outage, and gasket provide longevity and weatherproof protection. mounting screws.
5737TZ SPST 1000W 1800VA
eliminating costly maintenance. DST correction
built in. CATALOG UPC DEVICE CATALOG UPC DESCRIPTION
5737TM SPST 1000W 1800VA DEVICE NO. CODE DESCRIPTION NO. CODE
HOUSING: UV stabilized, ANSI color-coded Shorting cap
polypropylene dome. UV stabilized, clear acrylic 480VAC max
5500 61130
window. ABS base. Cross-linked, polypropylene WIRING DIAGRAMS 1800 Tungsten
1800VA Ballast Receptacle with Neoprene
gasket. 2223 61025 gasket
Open cap
ENERGY SAVINGS: Works with screw base 5500-OC 61132 480VAC max
(Black housing)
CFLs and LED lamps. N L1
2" Line
2 3/16"
(Black) Load (Red)

ORDERING INFO Receptacle Surface Neutral Load RECEPTACLE RECEPTACLE


(White)
120-480V receptacle with color-coded #14 leads, mounting bracket and one 120-480V receptacle with color-coded #14 leads, plastic housing, lock nut (with
CATALOG UPC VOLTAGE 12" NPT) and a mounting bracket.
NO. CODE 50-60Hz 3 1/8"
105-305 VAC
single phase grounded supplies and loads mounting screw.

5737TZ 62010 105-305VAC CATALOG UPC DEVICE CATALOG UPC DESCRIPTION


DEVICE NO. CODE DESCRIPTION NO. CODE
120 or
5737TM 62009 105-305VAC 277V
N L1
2" Line
2 3/16"
(Black) Load (Red)
Receptacle and mounting Receptacle with plastic
2224 61026 2421 61021
Receptacle Surface Neutral
(White)
Load
bracket housing and bracket
105-305 VAC
3 1/8" single phase grounded supplies and loads

FOR 240V, N=L2, L1=L1

PHOTOCONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 23 USA 800.321.5847 www.nsiindustries.com TORK 24
ELECTROMECHANICAL
TIME SWITCHES
FEATURES
QUICK LOOK
COMMON FEATURES
EASYTOSET DIAL ASSEMBLY
Torks 24 hour dial assembly allows the user
to set the time switch more accurately, easily
moving it by hand in small increments. Dial
can provide up to 12 ON/OFFs per day with
cycles as short as 20 minutes. AM and PM
settings are easy to see by the light and dark
MINIMUM MAX ON areas of the dial.
SETTINGS SKIP
PAGE CLOCK MANUAL SUNRISE/ & OFF RATINGS RESERVE
SERIES (MINUTES) A SWITCH TYPES
NO. DIAL OVERRIDE SUNSET EVENTS (AMPS) POWER
DAY
ON OFF PER DAY CAPTIVETABS DUTYCYCLEDIAL
TU40 29 24 Hour 15 15 Permanent 48 SPST DPST SPDT DPDT 40 For applications requiring many ON/OFF
cycles per day, captive tabs on this dial tilt
in and out just using your fingertip!
1100 31 24 Hour 20 75 Yes 12 SPST DPST 40
SPRINGWOUNDRESERVE
During power outages, precision spring
7000 33 24 Hour 20 75 Yes Yes 12 SPST DPST SPDT DPDT 3PST 40 Available mechanism takes over instantly and
automatically. Keeps the mechanism on
time up to 16 hours on 24 hour models
20 or 40 and up to 24 hours on 7 day models.
7000Z 35 24 Hour
Minute Offset
Yes Yes Astronomic 1 SPST DPST SPDT DPDT 3PST 40 Available FIELDUPGRADEABLE No resetting is needed after power
ASTRONOMICDIALS resumes, and field installation is easy!
20 or 40 Permanent
TZ 49 24 Hour
Minute Offset
Yes
by circuit
Astronomic 1 DPDT 3PST 20 Standard All Tork 24 Hour Time Switches can
be upgraded in the field to astronomic
operation.
3PST
W 43 7 Day 60 120 Yes Yes 2 SPST DPST SPDT DPDT
4PST
40 Available ENCLOSEDMOTOR
Time switch motors are enclosed to
Permanent protect from dust and damage.
TW 47 7 Day 60 120 Yes 2 DPDT 3PST 20 Standard
by circuit

Permanent Photo 2 SPDT


T900 45 7 Day 60 120 Yes 2 20 Standard
by circuit Control 3 SPDT

1847A 41 24 Hour 20 75 Yes 12 SPDT, Momentary Contact 10 Available

20 or 40
REMOVABLEDOOR
1847AZ 41 24 Hour Yes Yes Astronomic 1 SPDT, Momentary Contact 10 Available
Minute Offset
Tork time switches feature removable
doors to provide easy access for
1847AW 41 7 Day 60 120 Yes Yes 2 SPDT, Momentary Contact 10 Available installation and wiring.

TORK Electromechanical
8000 37 24 Hour 15 15 Available 48 SPDT 20 Available Controls are designed and
manufactured with components
6, 12, 30 Varies by dial which adhere to the highest
8000 39 30/dial SPDT 20 industry standards. Trained
& 60 Min. 6 sec. to 1 min.
personnel and in-process quality
procedures ensure that every
WH2 40 24 Hour 20 75 Yes 12 DPST 40
unit meets our strictest quality
standards.

TORK 27 TORK 28
TU40 SERIES SPECIFICATIONS CONTACT RATINGS
UNIVERSAL MULTI-VOLTAGE NEW!
MORE WIRING RATING
TYPE VOLTAGE
SAME ON/OFF TIMES EACH DAY SPACE! INPUT VOLTAGE: 120/208-240/277VAC, NO NC
24 HOUR TIME SWITCH 60Hz (auto detection).
General Purpose 120-277VAC 40A 30A
TIMING ACCURACY: Line frequency.
Inductive 120-277VAC 30A 15A
TERMINAL RANGE: #8 - #18 AWG.
120VAC 30A 10A
OPERATING TEMPERATURE: Ballast
277VAC 20A 10A
APPLICATIONS -31F to 116F (-35C to +47C).
Tungsten 120VAC 15A
POWER CONSUMPTION: 6 watts maximum.
Lighting 120VAC 1HP, 30FLA, 90LRA HP, 12FLA, 30LRA
ENCLOSURE: Polycarbonate Indoor/Outdoor Motor Load
Pumps 240VAC 2HP, 20FLA, 60LRA HP, 12FLA, 33LRA
NEMA 3R or -Y suffix metal indoor NEMA 1
Signs enclosure. Both with lockable hasp standard (see 120VAC 720VA 290VA
Pilot Duty
Air conditioning page 153 for enclosure dimensions). 240VAC 720VA 360VA
Water heaters Resistive 28VDC 20A
Fans
Max above 104F 120-277VAC 30A

WIRING DIAGRAMS

DTU40
ORDERING INFO Typical
Typical Wiring
Wiring Diagram,
Diagram, 120120/277VAC Application
VAC Application

FEATURES CATALOG UPC TIMER SUPPLY DRY CONTACTS ENCLOSURE TIMER


NO. CODE (VAC) 60Hz (UNPOWERED) TYPE SUPPLY
Plastic Indoor/Outdoor H N NC NO C NC NO C
MULTI-VOLTAGE: Automatic input voltage TU40 24000 120/208-240/277 DPDT
NEMA 3R
detection. LOAD LOAD
Metal Indoor
TU40-Y 24001 120/208-240/277 DPDT
EASY SET: Real time clock face and day/night NEMA 1
L N N L N L
markings for setting trippers.
Typical Wiring Diagram, 208-240 VAC Application
SCHEDULING: Minimum ON is setting 15
TIMER
minutes. Dial has 96 captive trippers. SUPPLY
4 in 1 CONTACTS: DPDT can also wire as SPST, H N NC NO C NC NO C
SPDT, & DPST. LOAD
BYPASS SWITCH: Sets timer to permanent
ON, OFF or timer operation. L1 L2 L1 L2

VACATION MODE: Set timer OFF with no


change of tripper settings. DTWH40
INDICATING LIGHTS: Power ON green and Typical
Typical Typical
Wiring
Wiring Wiring120
Diagram,
Diagram, Diagram, 120VAC
120/277VAC Application
VAC Application
load ON red and LED indicators.
TIMER
SPECIFICATION WRITERS GUIDE SUPPLY
Furnish and install, where shown, a TORK time switch with
H N
24 hour dial. The Time switch input shall be multi-voltage input 120/208/240/277VAC. Time Switch
NC NO C NC NO C
contacts shall be capable of switching 40 amperes per pole continuously up to 277 volts, and shall be DPDT, covering SPST, SPDT and DPST applications as
required. Captive ON/OFF trippers shall accomplish 1-48 operation per day.LOAD96 trippers permits
LOAD
15 minutes switching changes. Enclosure shall be Heavy duty
lockable plastic Indoor/Outdoor NEMA 3R surface type, finished in beige, with combination 12, 34 knockouts on bottom sides and back. Provisions shall be
made for positive padlocking. Terminal shall be capableL of receiving
N #8-#18N AWGL wire. The TimeN Switch
L shall be TORK Model TU40_.
Typical Wiring
Typical Diagram, 208-240
Wiring Diagram, VAC Application
240VAC
TIMER
SUPPLY
H N NC NO C NC NO C

ELECTROMECHANICAL LOAD
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC L1 L2 L1 L2
TORK 29 USA 800.321.5847 www.nsiindustries.com TORK 30
1100 SERIES SPECIFICATIONS CONTACT RATINGS
SAME DAY ON/OFF CONTACT
TYPE VOLTAGE
TIMES EACH DAY INPUT VOLTAGE: 120 or 208-277 VAC RATING
24 HOUR TIME SWITCH 60 Hz, varies by model. 120 -277VAC
General Purpose 40A
TIMING ACCURACY: Line frequency. single phase
120 -277VAC
Resistive 40A
TERMINAL RANGE: #8 - #14 AWG. single phase

OPERATING TEMPERATURE: Tungsten 120VAC 40A


APPLICATIONS -40 to 165F (-40 to +74C). 120, 277VAC
Inductive 20A
POWER CONSUMPTION: single phase
Lighting 3 watts maximum. Pilot Duty 120 -277VAC 1000VA
Pumps
ORDERING INFO ENCLOSURE: Lockable hasp. Type varies 120VAC 2HP
Signs by model (see page 153 for enclosure
Motor
240VAC 5HP
Air conditioning CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE dimensions).
NO. CODE (VAC) 60Hz CONTACTS TYPE Model 1101-7 is 30 AMP inductive at 347 volts and CSA only.
Water heaters
Fans Metal Indoor OTHER MOUNTINGS:
1101 10011 120 SPST Intermatic Adaptor Plate model #IAP allows
NEMA 1
Noryl Indoor/Outdoor any 1100 series to fit into an Intermatic case.
Automatic ON/OFF control 1101-N 10040 120 SPST
NEMA 3R
when operation is required at 1101-NC 10053 120 SPST Noryl Indoor/Outdoor
the same time every day. w/ clear Lexan cover
Metal Indoor/Outdoor
1101-O 10015 120 SPST NEMA 3 WIRING DIAGRAMS
1101-M 10022 120 SPST Mechanism
1101 & 1102 (SPST) 1103 (DPST)
Mechanism and
1101-M-IAP 10052 120 SPST mounting plate
Metal Indoor M M
1101-7 10033 347 SPST NEMA 1
FEATURES Metal Indoor
1102 10012 208-277 SPST NEMA 1 Removable
Noryl Indoor/Outdoor L 1 X 2
SCHEDULING: Minimum ON is setting 20 1102-N 10045 208-277 SPST Bridge
L 1 X 2
NEMA 3R
minutes with a minimum OFF setting of 75
Metal Indoor/Outdoor
minutes. Dial accommodates up to 12 pairs of 1102-O 10046 208-277 SPST NEMA 3 H LOAD H
trippers. One pair included. N
1102-M 10035 208-277 SPST Mechanism N LOADS
MANUAL OVERRIDE: Until the next Metal Indoor
For separate motor terminals
remove bridge from terminals 1 & L.
H

regularly scheduled ON or OFF automatic 1103 10013 120 DPST NEMA 1


operation then resumes. Noryl Indoor/Outdoor
1103-N 10041 120 DPST
NEMA 3R M M
Noryl Indoor/Outdoor 1104 (DPST) (Both)
1103-NC 10054 120 DPST w/ clear Lexan cover
Metal Indoor/Outdoor
1103-O 10016 120 DPST Must be
NEMA 3 L 1 X 2 same phase L 1 X 2
H
1103-M 10023 120 DPST Mechanism H
LOAD H LOAD LOAD
Metal Indoor H
1104 10014 208-277 DPST N
NEMA 1 TYPICAL FOR
Noryl Indoor/Outdoor 240V SUPPLY TYPICAL FOR Typical for double pole
1104-N 10042 208-277 DPST NEMA 3R 277V SUPPLY Cut motor lead at 1

Noryl Indoor/Outdoor
1104-NC 10055 208-277 DPST w/ clear Lexan cover
Metal Indoor/Outdoor
1104-O 10017 208-277 DPST NEMA 3 SPECIFICATION WRITERS GUIDE
1104-M 10014 208-277 DPST Mechanism Furnish and install, where shown, a TORK time switch with 24 hour dial. The time switch shall be powered by a self-starting synchronous motor. Time switch
Mechanism contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST as required). Removable ON/OFF trippers shall
1104-M-IAP 10051 208-277 DPST make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure
and mounting plate
Replacement Order #P47 for a pair of ON/OFF trippers shall be NEMA 1 surface type, finished in beige enamel, with combination 12, 34 knockouts on bottom, both sides and back. Provision shall be made for
Trippers positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model 11_ _ (11_ __, etc, to fit requirement).
Replacement #101 (120V) & #201 (208-277V)
Motor For Astronomic Conversion: Order #Z KIT

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 31 USA 800.321.5847 www.nsiindustries.com TORK 32
7000 SERIES SPECIFICATIONS CONTACT RATINGS
WITH SKIP-A-DAY FEATURE CONTACT
TYPE VOLTAGE
RESERVE POWER OPTIONAL INPUT VOLTAGE: 120 or 208-277 VAC RATING
24 HOUR TIME SWITCH 60 Hz varies by model. 120 -277VAC
General Purpose 40A
single phase
TIMING ACCURACY: Line frequency.
120 -277VAC
Resistive 40A
TERMINAL RANGE: #8 - #14 AWG. single phase

OPERATING TEMPERATURE: Tungsten 120VAC 40A


CALIFORNIA Title 24 -40 to 165F (-40 to +74C).
APPLICATIONS Inductive
120, 277VAC
20A
ASHRAE 90.1
POWER CONSUMPTION: 3 watts, single phase
Lighting 5 watts for L models maximum. Pilot Duty 120 -277VAC 1000VA
Heating ENCLOSURE: Lockable hasp. Type varies 120VAC 2HP
Pumps Motor
by model (see page 153 for enclosure 240VAC 5HP
Air conditioning dimensions).
Signs
OTHER MOUNTINGS:
ORDERING INFO Intermatic Adaptor Plate model #IAP
Automatic ON/OFF control allows any 7100 and 7200 series (except
CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE
when operation is required at NO. CODE (VAC) 60Hz CONTACTS TYPE L models) to fit into an Intermatic case.
the same time every day, with Metal Indoor
optional versatility of one to six 7100 10001 120 SPST NEMA 1
days omission. 7102 10002 208-277 SPST Metal Indoor
NEMA 1
Metal Indoor WIRING DIAGRAMS
7200 11001 120 DPST NEMA 1
Metal Indoor/Outdoor 7100 SPST 7200 DPST 7300 3PST
NEW! 7200-O 10512 120 DPST 7100 SPST 7200 DPST 7300 3PST
NEMA 3 M M M
Metal Indoor M M M
7202 11002 208-277 DPST
FEATURES NEMA 1
Metal Indoor/Outdoor L 1 X 2
NEW!
7202-O 10509 208-277 DPST L 1 X 2
NEMA 3 L 2
L 1
L
X
1
2
X 2
SCHEDULING: Minimum ON setting is Metal Indoor/Outdoor L 2 L
3 L 4
7300 12001 120 3PST 3 4
20 minutes with minimum OFF setting at NEMA 3 H LOAD LOAD LOAD L
H L
75 minutes. Dial accommodates up to 12 7302 12002 208-277 3PST Metal Indoor/Outdoor N
N
LOAD
H
H
LOAD LOAD 5 6
5 6
pairs of trippers. One pair included. NEMA 3 N
N
L
L LOAD LOAD LOAD
H
Metal Indoor H
LOAD LOAD LOAD

7120 13001 120 SPDT N


SKIP-A-DAY: Omit operations on any NEMA 1 N

day with a 7-spoke wheel marked with Metal Indoor


7122 13002 208-277 SPDT NEMA 1 7120 SPDT 7200Z
7220 DPDT (DPST) 7302 3PST 7120Z (SPDT)
days of week. 3 omitting screws included. 7120 SPDT 7220 DPDT
Metal Indoor
7220 14001 120 DPDT
MANUAL OVERRIDE: Until the next NEMA 1 M M
M
M M
M
regularly scheduled ON or OFF, automatic Metal Indoor M
7222 14002 208-277 DPDT NEMA 1
operation then resumes. L 1 X 2
WITH RESERVE POWER L 1 X 2
L 1 X 2 H L 1 X 2
OPTIONAL RESERVE POWER: L 7200L 19003 120 DPST Metal Indoor L 1 X
L 1
2
X 2H
L 1LOAD X 2
L
3H 4 H
models keep dial on time up to 16 hours NEMA 1 H
H
H
LOAD LOAD L
LOAD
H
H H N LOAD LOAD
during power outage. Metal Indoor H 5
N 6
7202L 19004 208-277 DPST LOAD LOAD N
A B
NEMA 1 A B LOAD
A
LOAD
B H
L 3 5
L
4 LOAD
3 5 4
L
LOAD LOAD LOAD LOAD N
Metal Indoor/Outdoor N N H
7300L 19005 120 3PST N
LOAD N
LOAD N H
NEMA 3 N
N
LOAD LOAD

N FOR USE WITH 3 PHASE 4-WIRE


Metal Indoor/Outdoor N
7302L 19006 208-277 3PST 120/208V SYSTEMS.
NEMA 3
Metal Indoor
7120L 19007 120 SPDT NEMA 1 SPECIFICATION WRITERS GUIDE
Metal Indoor
7220L 19009 120 DPDT NEMA 1 Furnish and install, where shown, a TORK time switch with 24 hour dial and day-omitting device. The time switch shall be powered by a self-starting synchronous
Metal Indoor motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required).
7222L 19011 208-277 DPDT Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF
NEMA 1
Replacement Order #P49 for a pair of ON/OFF per dial. Additional ON/OFF trippers per period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 12, 34 knockouts on bottom, both sides and back.
Trippers dial order #P47. 3 omitting screws #53005 supplied. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time Switch shall be TORK Model 7_ _ _ (to fit requirement).
Replacement #101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 FOR RESERVE POWER (MODELS WITH SUFFIX L): Spring-driven reserve shall be provided sufficient to operate the time switch contacts at least 16 hours after
Motor (208-277V). For Astronomic Conversion: Order #Z KIT for 7000 Series.
power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 33 USA 800.321.5847 www.nsiindustries.com TORK 34
7000Z SERIES SPECIFICATIONS CONTACT RATINGS
WITH SKIP-A-DAY FEATURE ADJUSTS TO DAILY CHANGES CONTACT
RESERVE POWER OPTIONAL IN SUNSET TIMES! INPUT VOLTAGE: 120 or 208-277 VAC TYPE VOLTAGE
RATING
ASTRONOMIC TIME SWITCH 60 Hz, varies by model. 120 -277VAC
General Purpose 40A
single phase
TIMING ACCURACY: Line frequency.
120 -277VAC
Resistive 40A
TERMINAL RANGE: #8 - #14 AWG. single phase

OPERATING TEMPERATURE: Tungsten 120VAC 40A


CALIFORNIA Title 24
APPLICATIONS -40 to 165F (-40 to +74C). 120, 277VAC
ASHRAE 90.1 Inductive 20A
POWER CONSUMPTION: 3 watts, single phase
Parking lots 5 watts for L models maximum. Pilot Duty 120 -277VAC 1000VA
Walkways
ENCLOSURE: Lockable hasp. Type varies 120VAC 2HP
Outdoor signage Motor
by model (see page 153 for enclosure 240VAC 5HP
Window displays dimensions).
Canopy lighting
Landscape lighting

Automatic ON at dusk, OFF


at dawn. Control of outdoor WIRING DIAGRAMS
lighting.
ASTRONOMIC LATITUDE
7200Z (DPST) 7302ZONES
3PST 7120Z (SPDT) 7200Z (DPST)
M M M
45 WASHINGTON MONTANA NORTH DAKOTA
MINN
M
MICHIGAN
MAINE

42
WISCONSIN

ORDERING INFO OREGON


IDAHO
SOUTH DAKOTA L 1 X 2
VT

NH
WYOMING
L 1 X 2 IOWA NEW YORK MASS
L 2
1 X
40 NEBRASKA
L PENNSYLVANIA
RHODE ISLAND L 1 X 2

FEATURES
3
ILLINOIS IND OHIO
4 CONNECTICUT

CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE NEVADA UTAH COLORADO


WEST
NEW JERSEY H
NO. CODE (VAC) 60Hz CONTACTS 38 H
KANSAS

TYPE
VIRGINIA
LOAD LOAD L MISSOURI
DELAWARE

H KENTUCKY VIRGINIA MARYLAND LOAD LOAD LOAD LOAD


CALIFORNIA
5 6 A H
B
N TENNESSEE NORTH CAROLINA

Noryl Indoor/Outdoor
OKLAHOMA
N
ARKANSAS
L
ASTRONOMIC SCHEDULING: Turn 7200Z* ** 120 DPST N
ARIZONA
H
SOUTH
N
NEW MEXICO
LOAD LOAD LOAD

NEMA 3R 34 H
CAROLINA
MISS

N
ON at sunset and OFF at sunrise daily.
TEXAS ALABAMA GEORGIA

Noryl Indoor/Outdoor
7202Z* ** 208-277 DPST
LOUISIANA

OFF time can be set from 8:30PM to NEMA 3R


MEXICO
FOR USE WITH 3 PHASE 4-WIRE
7200Z (DPST) 7302 3PST 7120Z (SPDT)
120/208V SYSTEMS.
2:30AM. Can be individually offset +/- 20 30 FLORIDA

Metal Indoor/Outdoor
or 40 minutes from both sunset and OFF 7300Z* ** 120 3PST 18 HAWAII 18 PUERTO M
NEMA 3 M M
RICO
times. Available from 18 - 45 northern Metal Indoor/Outdoor
7302Z* ** 208-277 3PST
latitudes. NEMA 3 L 1 X 2
L 1 X 2
Noryl Indoor/Outdoor L 1 X 2
SKIP-A-DAY: Omit operations on any 7120Z* ** 120 SPDT NEMA 3R
L
3 4 H

day with a 7 spoke wheel marked with H


LOAD LOAD L H
LOAD LOAD
days of the week. 3 omitting screws WITH RESERVE POWER N
5 6 A B
L
H N
included. N
LOAD LOAD LOAD

Noryl Indoor/Outdoor
7200ZL* ** 120 DPST NEMA 3R
N

MANUAL OVERRIDE: Until the next FOR USE WITH 3 PHASE 4-WIRE
Noryl Indoor/Outdoor 120/208V SYSTEMS.
regularly scheduled ON or OFF, automatic 7202ZL* ** 208-277 DPST NEMA 3R
operation then resumes. Metal Indoor/Outdoor
7300ZL* ** 120 3PST
OPTIONAL RESERVE POWER: L NEMA 3
models keep dial on time up to 16 hours Metal Indoor/Outdoor
7302ZL* ** 208-277 3PST NEMA 3 SPECIFICATION WRITERS GUIDE
during power outage.
Noryl Indoor/Outdoor Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time switch
7120ZL* ** 120 SPDT NEMA 3R contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur
Noryl Indoor/Outdoor automatically at sunset (in city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and
7122ZL* ** 208-277 SPDT NEMA 3R
OFF shall have a range of adjustability of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor
Replacement #101 (120V) & #201 (208-277V).
Motor For "L" models #36 (120V) & #46 (208-277V) Noryl 3PST is NEMA 3 metal indoor/outdoor. Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time switch shall be TORK Model
7_ _ _Z (to fit requirement).
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). FOR RESERVE POWER (Add Suffix L): Spring driven reserve shall be provided sufficient to operate the time switch contacts for at least 16 hours after power
**Consult factory for UPC number.
failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 35 USA 800.321.5847 www.nsiindustries.com TORK 36
8000 SERIES SPECIFICATIONS CONTACT RATINGS
MANY DAILY ON/OFF CONTACT
INPUT VOLTAGE: 120, 208-277VAC or TYPE VOLTAGE
OPERATIONS PER DAY RATING
480VAC, 60Hz, varies by model.
DUTY CYCLE Resistive
120 or 240VAC 20A
24 HOUR TIME SWITCH TIMING ACCURACY: Line frequency. 480VAC 20A

TERMINAL RANGE: #8 - #14AWG. Motor 120VAC 3/4 HP

OPERATING TEMPERATURE:
-40 to 165F (-40 to +74C).
APPLICATIONS
POWER CONSUMPTION: 3 watts,
Duty cycling 5 watts for L models maximum.
Ventilating fans 8001-N ENCLOSURE: Lockable hasp. Type varies
Pumping by model (see page 153 for enclosure
Irrigation ORDERING INFO
dimensions).
Process control OTHER MOUNTINGS: Intermatic
Laboratory experiments CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE
Adaptor Plate model #IAP allows 8001 &
NO. CODE (VAC) 60Hz CONTACTS TYPE
8004 to fit into an Intermatic case.
For one or multiple daily Metal Indoor
8001 70001 120 SPDT NEMA 1
ON/OFF operations.
Noryl Indoor/Outdoor
8001-N 70025 120 SPDT NEMA 3R
Noryl Indoor/Outdoor NEMA
8001-NC 70009 120 SPDT 3R w/ clear Lexan cover WIRING DIAGRAMS
8001-LC/WB 70010 120 SPDT Mechanism and bracket
Metal Indoor/Outdoor
8001-O 70029 120 SPDT NEMA 3
FEATURES 8004 70002 208-277 SPDT Metal Indoor ALL SPDT M
NEMA 1 MODELS
Metal Indoor
SCHEDULING: Minimum ON setting is 8001U 70003 480/120 Trans. SPDT NEMA 1
15 minutes with minimum OFF setting at Noryl Indoor/Outdoor
15 minutes. Dial accommodates up to 96 NEW! 8001U-N 70014 480/120 Trans. SPDT NEMA 3R
captive tabs. Metal Indoor/Outdoor
C NC NO
NEW! 8001U-O 70011 480/120 Trans. SPDT L 2
NEMA 3
DUTY CYCLE: Adjustable from 12, 1, 2,
24 HOUR WITH 7 DAY OMIT H LOAD 2
3, 4, 6, 12, and 24 hours.
Metal Indoor 120VAC
CLOSED WITH
8007 70005 120 SPDT TAB OUTWARD
SKIP-A-DAY: Some models include 7 NEMA 1
N
day or 14 day wheel to omit selected days Metal Indoor/Outdoor LOAD 1
8007-O 70012 120 SPDT
of the week. NEMA 3 CLOSED WITH
TAB INWARD
Metal Indoor
8008 70006 208-277 SPDT
OPTIONAL RESERVE POWER: L NEMA 1
models keep dial on time up to 16 hours Metal Indoor
NEW! 8007U 70008 480/120 Trans. SPDT
during power outage. NEMA 1
Metal Indoor/Outdoor
NEW! 8007U-0 70028 480/120 Trans. SPDT
NEMA 3 SPECIFICATION WRITERS GUIDE
24 HOUR WITH 7 DAY OMIT & RESERVE POWER
The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall
Metal Indoor
8007L 70015 120 SPDT
NEMA 1
be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike.
Metal Indoor The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism
8008L 70016 208-277 SPDT shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD:
NEMA 1
24 HOUR WITH 14 DAY OMIT The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the
Metal Indoor time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork
8007V 70007 120 SPDT NEMA 1 Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit,
24 HOUR WITH 14 DAY OMIT & RESERVE POWER which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The
8007VL 70017 120 SPDT Metal Indoor unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.
NEMA 1
Replacement #101(120V) & #201 (208-277V).
Motor For L models #36 (120V) & #46 (208-277V)

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 37 USA 800.321.5847 www.nsiindustries.com TORK 38
8000 SERIES SPECIFICATIONS WH2 SPECIFICATIONS
MULTIPLE ON/OFF CYCLES PER DAY 24 HOUR WATER HEATER
REPEATING VARIABLE CYCLE INPUT VOLTAGE: 120VAC, 60Hz. TIME SWITCH INPUT VOLTAGE: 208 250V 60 Hz.
TIME SWITCH TIMING ACCURACY: Line frequency. TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG. TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE: OPERATING TEMPERATURE:
-40 to 165F (-40 to +74C). -40 to 165F (-40 to +74C).
APPLICATIONS POWER CONSUMPTION: APPLICATIONS SAVE POWER CONSUMPTION:
3 watts maximum. ENERGY! 3 watts maximum.
Avoid utility peak rates
Duty cycling Automatic ON/OFF control of Turn off when not needed
REPLACEMENT TRIPPERS: #P49 for a ENCLOSURE: Indoor NEMA 1 Metal with
Ventilating fans pair with one ON and one OFF per dial for
electric water heaters. Schedules
lockable hasp (see page 153 for enclosure
Pumping additional ON/OFF trippers per dial order the water heater to turn ON only dimensions).
Irrigation #P47. 3 omitting screws #53005 supplied. when needed, avoiding energy
Process control waste when hot water is not
ENCLOSURE: Indoor NEMA 1 Metal with needed.
Laboratory experiments
lockable hasp (see page 153 for enclosure
dimensions).
For one or many daily ON/OFF
operations.

CONTACT RATINGS
CONTACT RATINGS TYPE VOLTAGE
CONTACT
FEATURES FEATURES RATING
CONTACT
TYPE VOLTAGE
SCHEDULING: 60 captive tabs per dial RATING Resistive 208-277VAC 40 A, 10,000W
SCHEDULING: Minimum ON is setting 20 minutes
with minimum ON/OFF settings: 120 or 240VAC 20A
Resistive with a minimum OFF setting of 75 minutes. Dial Replacement Motor #201 (208-277V)
60 minute dial with 1 minute tabs. 480VAC 20A
accommodates up to 12 pairs. 3 pairs of trippers
30 minute dial with 30 second tabs. Motor 120VAC 3/4 HP supplied. Replacement Trippers Order #P47 for a pair of ON/OFF trippers
12 minute dial with 12 second tabs.
6 minute dial with 6 second tabs. EXTERNAL MANUAL OVERRIDE: Until the
WIRING DIAGRAMS next regularly scheduled ON or OFF automatic WIRING DIAGRAMS
DUTY CYCLE: Settings of 160 th of dial operation then resumes.
speed.
TYPICAL FOR 240
ALL SPDT M
ORDERING INFO VOLT SUPPLY
MODELS ORDERING INFO
CATALOG UPC INPUT SUPPLY OUTPUT TYPE CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE M
NO. CODE (VAC) 60Hz CONTACTS NO. CODE (VAC) 60Hz CONTACTS TYPE

8601 70034 120 SPDT 60 Minute Metal Indoor


C NC NO WH2 70042 208-250 DPST
NEMA 1
L 2
8301 70033 120 SPDT 30 Minute
H LOAD 2 L 1 X 2
H
8121 70032 120 SPDT 12 Minute 120VAC
CLOSED WITH
TAB OUTWARD H LOAD
N
8061 70031 120 SPDT 6 Minute LOAD 1
CLOSED WITH
Replacement TAB INWARD
For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105.
Motor
Replacement #P49 for a pair with one ON and one OFF per dial for additional ON/OFF
Trippers trippers per dial order #P47. 3 omitting screws #53005 supplied.

ELECTROMECHANICAL
PHOTOCONTROLS
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 39 USA 800.321.5847 www.nsiindustries.com TORK 40
TORK 40
1800 SERIES SPECIFICATIONS CONTACT RATINGS
FOR MECHANICALLY HELD CONTRACTORS CONTACT
TYPE VOLTAGE
AND LOW VOLTAGE REMOTE CONTROL INPUT VOLTAGE: 120VAC or 208-277VAC, 60Hz, RATING
MOMENTARY CONTACT varies by model.
General Purpose 24-277VAC 10A
TIME SWITCH TIMING ACCURACY: Line frequency.
Pilot Duty 24-277VAC 360VA
TERMINAL RANGE: #12 - #22AWG.
OPERATING TEMPERATURE:
APPLICATIONS -40 to 165F (-40 to +74C).
CALIFORNIA Title 24
POWER CONSUMPTION: 3 watts, 5 watts for
Mechanically-held contactors ASHRAE 90.1 L models maximum.
3-wire momentary ENCLOSURE: NEMA 1 Metal with lockable hasp
lighting systems (see page 153 for enclosure dimensions).
Remote station switching

WIRING DIAGRAMS

OFF C ON TIMING MOTOR


ASTRONOMIC LATITUDE ZONES
MECHANICALLY-HELD
ORDERING INFO CONTACTOR
WASHINGTON MONTANA NORTH DAKOTA

120VAC, 60HZ
FEATURES
MINN

CATALOG UPC INPUT SUPPLY OUTPUT TYPE


MICHIGAN
L CLOSE
42
MAINE

NO. CODE (VAC) 60Hz CONTACTS


WISCONSIN VT
SOUTH DAKOTA
OREGON IDAHO NH

COMMON
WYOMING

NEBRASKA
IOWA NEW YORK MASS
N
RHODE ISLAND

SCHEDULING: Choice of three types.


PENNSYLVANIA

1847A 52001 120 SPDT 24 Hour


ILLINOIS IND OHIO CONNECTICUT
NEVADA UTAH COLORADO

KANSAS
WEST
VIRGINIA
NEW JERSEY
OPEN
ON
MISSOURI
DELAWARE
KENTUCKY

24 HOUR SKIP-A-DAY: Minimum ON setting


VIRGINIA MARYLAND
CALIFORNIA

1848A 52014 208-277 SPDT 24 Hour 34 OKLAHOMA TENNESSEE NORTH CAROLINA


ARKANSAS

is 20 minutes with minimum OFF setting at 75


ARIZONA NEW MEXICO SOUTH
CAROLINA
MISS

OFF
TEXAS ALABAMA GEORGIA

minutes. Dial accommodates up to 12 pairs of 1847AZ* ** 120 SPDT Astronomic LOUISIANA

trippers. Omit operations on any day with a 7 MOMENTARY PUSH BUTTON


MEXICO

30 FLORIDA

spoke wheel marked with days of week. 1847AW 52005 120 SPDT 7 Day
18 HAWAII 18 PUERTO
ASTRONOMIC SCHEDULING: Turn ON at sunset WITH RESERVE POWER
RICO

and OFF at sunrise daily. OFF time can be set from


8:30PM to 2:30AM. Can be individually offset +/- 1847AL 52006 120 SPDT 24 Hour
20 or 40 minutes from both sunset and OFF times.
1847AZL* ** 120 SPDT Astronomic
7 DAY SCHEDULING: Minimum ON setting is
1 hour with a minimum OFF setting of 2 hours. 1847AWL 52010 120 SPDT 7 Day
Minimum 8 hours between 2 OFF settings. 7 day For 24 hour models order #P49 for a pair ON/OFF per dial. Additional ON/OFF
calendar dial will accomodate up to 2 pairs on ON/ Replacement trippers per dial order #P47. 3 omitting screws #53005 supplied.
Trippers
OFF trippers per day - 7 pairs are supplied. 7 day models order #P69 for 7 pairs of ON/OFF trippers.
Replacement #101(120V) & #201 (208-277V). For L models #36 (120V)
MANUAL OVERRIDE: Until the next regularly Motor SPECIFICATION WRITERS GUIDE
scheduled ON or OFF, automatic operation then *Add degrees latitude to complete number (18, 30, 34, or 42). Furnish and install, where shown, a Momentary Contact time switch. Time switch shall have dial of the (24 hour with day omitting device) (Astronomic with day
resumes. **Consult factory for UPC number. omitting device) (7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and
correct installation using screw terminals for up to #12AWG wire. Timing motor terminals shall be completely independent from momentary switching circuit.
OPTIONAL RESERVE POWER: L models keep
Spring driven reserve mechanism shall be provided sufficient to operate time switch controls at least 16 hours after power failure. On restoration of power, time
dial on time up to 16 hours during power outage.
switch shall transfer to synchronous motor drive and automatically rewind reserve. Time switch shall include solid state circuit to provide a switch closure not
in excess of two seconds on both ON and OFF contactor coil terminals at such times as are set on dial: these settings to be made with removable trippers which
can be added and removed without tools (except the astronomic dial). Contactor coil circuits shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures
shall be NEMA 1 surface (or see other mountings), with provision for positive padlocking. Time switch shall be TORK Model 1847AL, 1848A, (AZL), (AWL).

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 41 USA 800.321.5847 www.nsiindustries.com TORK 42
W SERIES SPECIFICATIONS CONTACT RATINGS
DIFFERENT SCHEDULES EACH DAY CONTACT
TYPE VOLTAGE
7 DAY TIME SWITCH INPUT VOLTAGE: 120 or 208-277VAC, 60Hz, RATING
varies by model. 120 -277VAC
General Purpose 40A
single phase
TIMING ACCURACY: Line frequency.
120 -277VAC
Resistive 40A
TERMINAL RANGE: #8 - #14AWG. single phase

OPERATING TEMPERATURE: Tungsten 120VAC 40A


CALIFORNIA Title 24
APPLICATIONS -40 to 165F (-40 to +74C). 120, 277VAC
ASHRAE 90.1 Inductive 20A
single phase
POWER CONSUMPTION: 3 watts, 5 watts for
Heating L models maximum. Pilot Duty 120 -277VAC 1000VA
Air conditioning ENCLOSURE: Indoor NEMA 1 Metal with lockable 120VAC 2HP
Motor
Display lighting hasp. Other enclosures include metal Indoor/ 240 VAC 5HP
Ventilating systems Outdoor NEMA 3 with suffix "O" (see page 153 for
Lighted signage enclosure dimensions).
Storefront lighting
ORDERING INFO
CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE
NO. CODE (VAC) 60Hz CONTACTS TYPE WIRING DIAGRAMS
W100 (SPST) W200 (DPST) W300 (3PST) W120 (SPDT) W220 (DPDT)
W100 30001 120 SPST
M M
W100 (SPST) M
W200 (DPST) M W300 (3PST) W120 (SPDT) M W220 (DPDT)
W120 33001 120 SPDT L 1 X 2
M M
M M M
L 1 X 2
L 1 X 2
L
3 4 L 1 X 2 H LOAD

W200 31001 120 DPST L 2


L 1 X 2
L
H
LOAD LOAD H
Metal Indoor H L 1
LOAD XH
N
2
L
3 4 L
5 6
L 1 X 2
LOAD
A
H
B
L
LOAD 1 X 2
LOAD
L H 3 5 4 LOAD

L 2 N
W202 31011 208-277 DPST NEMA 1 H
L
LOAD LOAD LOAD
N H
N LOAD
N
LOAD

FEATURES
LOAD LOAD N H N
H H 5 6 LOAD LOAD L 3
LOAD 5 4 LOAD
N A B
N L
N
W220 34001 120 DPDT H
N
LOAD LOAD LOAD
N
N
LOAD LOAD
H

SCHEDULING: Minimum ON setting is 1 hour


W222 34011 208-277 DPDT
with a minimum OFF setting of 2 hours. Minimum W202 (DPST)
W400A (4PST)
8 hours between 2 OFF settings. Models W400A W300 32001 120 3PST
and W402A offer minimum ON/OFF settings of W400A
Equipment (4PST) W202MOTOR
(DPST)
MOTOR

312 hours. 7 day calendar dial accommodates up Metal Indoor/Outdoor Ground M


W300-O 32003 120 3PST
to 2 pairs of ON/OFF trippers per day 7 pairs are NEMA 3 Equipment
MOTOR MOTOR
A 1 2 3 4 L 1
H
L 1 X 2
Ground M
supplied. W302 32002 208-277 3PST H LOAD
LOAD LOAD

A Motor1
Clock 2 3 4 L 1
H L 1 X H 2

SKIP-A-DAY: Omit operations on any day.


H

Metal Indoor Supply


5 6 7 8 Typical for 208-240VAC Typical for 277VAC
W400A 35001 120 4PST H LOAD
LOAD LOAD

NEMA 1 H

MANUAL OVERRIDE: Until the next regularly Clock Motor H

Supply B Typical for 208-240VAC Typical for 277VAC


5 6 7 8
scheduled ON or OFF automatic operation then W402A 35002 208-277 4PST
resumes. B
WITH RESERVE POWER
OPTIONAL RESERVE POWER: L models keep Supply
W220L 39009 120 DPDT To Load(s)
dial on time up to 24 hours during power outage.
Supply
W222L 39010 208-277 DPDT To Load(s)

Metal Indoor
W300L 39005 120 3PST
NEMA 1 SPECIFICATION WRITERS GUIDE
Furnish and install, where shown, TORK time switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON/
W302L 39006 208-277 3PST
OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time switch contacts shall be capable of switching
W400AL 39007 120 4PST 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON/OFF trippers shall make possible
automatic operation with a minimum ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402
Replacement Order #P69 for 7 pairs of ON/OFF trippers offer minimum ON and OFF settings of 3.5 hours. Enclosure shall be NEMA 1 surface, finished in baked beige enamel, with combination 12 - 34 knock-outs
Trippers except W400 series use #P69i. on bottom and both sides. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK
#101 (120V) & #201 (208-277V). For W400 series units order #101i Model W_ _ _ (to fit requirement). FOR RESERVE POWER (Add suffix L): Spring-driven reserve shall be provided sufficient to operate the Time Switch contacts
Replacement
(120V) & #201i (208-277V). For L models order #36 (120V) at least 24 hours after power failure (16 hour reserve power on 4PST models). On restoration of power, time switch shall transfer to synchronous motor driven
Motor
and #46 (208-277V), except W400 series consult factory.
and automatically rewind reserve power unit.

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 43 USA 800.321.5847 www.nsiindustries.com TORK 44
T900 SERIES SPECIFICATIONS CONTACT RATINGS
PHOTOELECTRIC & 7 DAY CONTROL COMBO CONTACT
TYPE VOLTAGE
DIFFERENT SCHEDULES EACH DAY INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz, RATING
RESERVE POWER STANDARD varies by model.
General Purpose 120/277VAC 20A
2 & 3 CIRCUIT LIGHTING TIMING ACCURACY: Line frequency.
120VAC 1HP
CONTROL CENTERS TERMINAL RANGE: #8 - #14AWG. Motor
240VAC 2HP
OPERATING TEMPERATURE:
CALIFORNIA Title 24
APPLICATIONS -40 to 165F (-40 to +74C).
ASHRAE 90.1
POWER CONSUMPTION: 5 watts maximum.
Parking lot lighting ENCLOSURE: Indoor NEMA 1 Metal with
HVAC lockable hasp. Other enclosures include cover
Display lighting for access to by-pass switches with suffix "E" or
Security lighting Optional "E" cover Indoor/Outdoor NEMA 3 metal with suffix "O"
Lighted signage (see page 153 for enclosure dimensions).
Storefront lighting Model 2101
supplied with unit.

WIRING DIAGRAMS

T920L
T920L T930L
T930L
ONLYCIRCUITS
ONLY CIRCUITS1 1AND
AND2 2ARE
AREINCLUDED
INCLUDEDININT920L
T920L ALL3 3CIRCUITS
ALL CIRCUITSARE
AREINCLUDED
INCLUDEDININT930L
T930L
ORDERING INFO MANUAL
MANUAL CONTROLS
CONTROLS MANUAL
MANUAL CONTROLS
CONTROLS

FEATURES CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF

NO. CODE (VAC) 60Hz CONTACTS TYPE


AUTO
AUTO AUTO
AUTO AUTO
AUTO AUTO
AUTO AUTO
AUTO
Metal Indoor TIMETIME SWITCH
SWITCH NOTE:
NOTE: NOTE:
NOTE:
SCHEDULING: T920L 41033 120 2 SPDT OFF OFF ON ON Contacts
Contacts 7-12
7-12 Contacts
Contacts 4-12
4-12
NEMA 1 MM C C
RELAY
RELAY areare unpowered.
unpowered. C C
RELAY
RELAY areare unpowered.
unpowered.
CIRCUIT 1: ON automatically at dusk, OFF at Metal Indoor NEMA
individual preset times each day, including T920L-E 41034 120 2 SPDT PHOTOELECTRIC
PHOTOELECTRIC PHOTOELECTRIC
PHOTOELECTRIC
1 with switch access CONTROL
CONTROL CONTROL
CONTROL

skipping days when desired. Unit can be set to Metal Indoor/outdoor MM


TIME
TIME
T920L-O 41035 120 2 SPDT CONTACTOR
CONTACTOR SWITCH
SWITCH CONTACTOR
CONTACTOR

turn ON before dawn for early morning lighting. NEMA 3 CONTROL


CONTROL
CIRCUIT LINELINE
CIRCUIT
CONTROL
CONTROL
CIRCUIT
CIRCUIT

CIRCUIT 2: ON at dusk, OFF at dawn Metal Indoor 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12


T930L 41055 120 3 SPDT L1 L1 NEU.NEU. L1 L1 NEUNEU

automatically, daily. NEMA 1 H 120V


H 120V N N
60C 60C OPEN OPEN
OPEN
H 120V
H 120V N N
LINELINE
OPEN
OPEN OPENLINELINE
OPEN OPEN
OPEN
CLOSEOPEN LINELINE
CLOSE DUSKDUSK TO DAWN SAFETY LIGHTS BLACK 60C
BLACK
60C
CLOSE
CLOSE CLOSE
CLOSE DUSKDUSK TO DAWN SAFETY LIGHTS
Metal Indoor NEMA LINELINE TO DAWN SAFETY LIGHTS TO DAWN SAFETY LIGHTS
(PHOTOCELL
ON - ON - PHOTOCELL
OFF) OFF) LINELINE (PHOTOCELL
ON - ON - PHOTOCELL
OFF) OFF)
(PHOTOCELL PHOTOCELL 3 3 1 1 (PHOTOCELL PHOTOCELL
CIRCUIT 3: Individual daily ON and OFF settings T930L-E 41056 120 3 SPDT
1 with switch access
RED RED
WHITE
WHITE
CLOSE
CLOSE WHITE
WHITE
2 2
CLOSE
CLOSE

1 1 2 2 RED RED
at desired times, including skipping any desired Metal Indoor/outdoor
BLACK
BLACK
LOAD
LOAD LOAD
LOAD
day or days Minimum ON is setting 1 hour with T930L-O 41057 120 3 SPDT
NEMA 3
a minimum OFF setting of 2 hours. Minimum 8 Replacement
hours between 2 OFF settings. 7 day calendar dial #P69 for 7 pairs of ON/OFF trippers.
Trippers
will accommodate up to 2 pairs of ON-OFF trippers Replacement #36 (120V)
per day 7 pairs are supplied. Motor
Replacement
SKIP-A-DAY: Omit operations on any day. #66061 SPECIFICATION WRITERS GUIDE
Bypass Switch
MANUAL BY-PASS SWITCHES: Single pole, T900 SERIES Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanically-
20 Amps one per circuit. Factory pre-wired to held contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent
terminal strip. ON/OFF/AUTO positions for each contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different
circuit is independent will not disturb automatic ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit
settings. specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated
and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting
RESERVE POWER: Standard feature on all falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after
models keep dial on time up to 24 hours during power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN
power outage. LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or
equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads. only. Tork Model T-930L.

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 45 USA 800.321.5847 www.nsiindustries.com TORK 46
TW SERIES SPECIFICATIONS CONTACT RATINGS
DIFFERENT SCHEDULES EACH DAY CONTACT
TYPE VOLTAGE
MANUAL BYPASS SWITCHES INPUT VOLTAGE: RATING
RESERVE POWER STANDARD 120 or 208 - 277VAC, 60Hz, varies by model. General Purpose 120/277VAC 20A
7 DAY TIME SWITCH TIMING ACCURACY: Line frequency. 120VAC 1HP
Motor
TERMINAL RANGE: #8 - #14AWG. 240VAC 2HP
CALIFORNIA Title 24

ASHRAE 90.1 OPERATING TEMPERATURE:


APPLICATIONS -40 to 165F (-40 to +74C).
POWER CONSUMPTION: 5 watts maximum.
Heating Optional "E" cover
Air conditioning ENCLOSURE: Indoor NEMA 1 Metal with lockable
hasp (see page 153 for enclosure dimensions).
Display lighting
Ventilating systems
Lighted signage
Storefront lighting

WIRING DIAGRAMS
MANUAL CONTROLS
MANUAL
ON CONTROLS
OFF ON OFF ON OFF NOTE:
Switching contacts
ON OFF
AUTO
ON OFF
AUTO
ON OFF
AUTO
NOTE:
are unpowered
Switching contacts TW300L
AUTO AUTO AUTO
are unpowered
TW300L
ORDERING INFO M
TIME
SWITCH
When single line source is
M
TIME
SWITCH
When
used, single
jumperline source is
terminals
1 2 3 4 5 6 7 8 9
FEATURES CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE 1 2 3 4 5 6 7 8 9 LINE
used, jumper terminals
1-5-7-9 and connect all com-
NO. CODE (VAC) 60Hz CONTACTS TYPE 1-5-7-9 and connect2all com-
H N
LOAD
LINE mons to terminals and 3.
Metal Indoor H N
LINE
LOAD mons to terminals 2 and 3.
SCHEDULING: Minimum ON setting is 1 TW-220L 39013 120 DPDT LOAD
LINE
NEMA 1 LOAD
LINE
hour with a minimum OFF setting of 2 hours. Metal Indoor NEMA LOAD
LINE
Minimum 8 hours between 2 OFF settings. 7 day TW-220L-E 39021 120 DPDT 1 with switch access LOAD

calendar dial accommodates up to 2 pairs of Metal Indoor


TW-222L 39014 208-277 DPDT MANUAL CONTROLS
ON-OFF trippers per day 7 pairs are supplied. NEMA 1 MANUAL
ON CONTROLS
OFF ON OFF
Metal Indoor
SKIP-A-DAY: Omit operations on any day. TW-300L 39015 120 3PST
NEMA 1
ON OFF
AUTO
ON OFF
AUTO TW220L
Metal Indoor
AUTO AUTO TW220L
MANUAL OVERRIDE: Until the next TIME Wiring shown is for mechani-
TW-302L 39016 208-277 3PST M SWITCH CONTACTOR
NEMA 1 TIME Wiring shown
cally-held is for mechani-
contactors. Use
regularly scheduled ON or OFF, automatic 1
M SWITCH
2 3 4 5 6 7 8 9
CONTROL
CONTACTOR
CIRCUIT
Replacement CONTROL cally-held contactors.
CLOSE terminal onlyUse
for mag-
operation then resumes. Order #P69 for 7 pairs of ON/OFF trippers. 1 2 3 4 5 6 7 8 9 CIRCUIT COMMON
Trippers OPEN
COMMON
CLOSE terminalcontactors
netically-held only for mag-
and
H N
MANUAL BY-PASS SWITCHES: Single pole, Replacement CONTACTOR
CLOSE
OPEN netically-held contactors
to control direct and
loads not
#36 (120V) & #46 (208-277V) H N
CONTROL CLOSE
20 Amps one per circuit. Factory pre-wired Motor CONTACTOR
COMMON
toexceeding
control direct loads not
CIRCUIT
CONTROL COMMON
OPEN 2000 watts.
to terminal strip. ON/OFF/AUTO positions for Replacement #66061
CIRCUIT
CLOSE
OPEN exceeding 2000 watts.
each circuit is independent will not disturb Bypass Switch CLOSE

automatic settings.
SPECIFICATION WRITERS GUIDE
RESERVE POWER: Standard feature on all
Furnish and install, where shown, a TORK time switch of the 7 day type, capable of being set for different ON/OFF times each day of the week, to an operating accuracy
models keep dial on time up to 24 hours during
of plus or minus 15 minutes of the desired time. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be
power outage.
sufficient to operate the time switch contacts at least 24 hours after power outage. On restoration of power, time switch shall transfer to synchronous motor drive and
automatically rewind reserve power unit. Time switch shall provide for automatic operation with a minimum of one hour between an ON/OFF operation with minimum
of four ON/OFF operations per day. ON/OFF operations shall be accomplished by removable ON/OFF trippers on the dial. Time switch contacts shall be capable of
carrying a minimum 20 amperes per pole continuously at 277 volts and shall be DPDT or 3PST. Manual switches shall be provided as an integral part of the time switch,
one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable
of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 12 - 34 combination knock-outs on bottom, both sides and
top. Provision shall be made for positive padlocking. (Specify E door for manual switches to be accessible when case is locked). Shall be TORK Model TW (to fit switch
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads. requirement) or equal in general purpose NEMA 1, (general purpose metal) or (Indoor/Outdoor NEMA 3) enclosure.

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 47 USA 800.321.5847 www.nsiindustries.com TORK 48
TZ SERIES SPECIFICATIONS CONTACT RATINGS
MANUAL BYPASS SWITCHES CONTACT
TYPE VOLTAGE
RESERVE POWER STANDARD INPUT VOLTAGE: RATING
ASTRONOMIC TIME SWITCH 120 or 208 - 277VAC, 60Hz, varies by model. General Purpose 120/277VAC 20A
TIMING ACCURACY: Line frequency. 120VAC 1HP
Motor
TERMINAL RANGE: #8 - #14AWG. 240VAC 2HP

CALIFORNIA Title 24 OPERATING TEMPERATURE:


APPLICATIONS ASHRAE 90.1
-40 to 165F (-40 to +74C).
POWER CONSUMPTION: 5 watts maximum.
Schools
ENCLOSURE: Indoor NEMA 1 Metal with
Industrial yards
lockable hasp and for some models enclosures
Shop windows is Indoor/Outdoor NEMA 3 metal with suffix "O"
Parking lots (see page 153 for enclosure dimensions).
Highway signs
Bridges
WIRING DIAGRAMS

ASTRONOMIC LATITUDE ZONES MANUAL CONTROLS

MANUAL CONTROLS NOTE:


Switching contacts
AUTO
NOTE:
are unpowered
Switching contacts TZ300L
45 WASHINGTON MONTANA NORTH DAKOTA
MINN
MICHIGAN
MAINE TIME
AUTO
are unpowered
TZ300L
When single line
M
WISCONSIN VT SWITCH sourcesingle
When is used,
line
42
SOUTH DAKOTA
OREGON TIME
jumperis terminals
IDAHO NH
M
WYOMING
1 2 SWITCH
3 4 5 6 7 8 9 source used,
ORDERING INFO
IOWA NEW YORK MASS

NEBRASKA 1, 5, 7,terminals
jumper 9 and connect
40
RHODE ISLAND
PENNSYLVANIA
1 2 3 4 5 6 7 8 9 LINE
1,all5,commons
7, 9 and toconnect
ILLINOIS IND OHIO CONNECTICUT
NEVADA UTAH COLORADO NEW JERSEY
LOAD
WEST
H N LINE
FEATURES CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE allterminals
commons2 andto 3.
KANSAS VIRGINIA

38 LINE
MISSOURI
KENTUCKY
DELAWARE
LOAD
NO. CODE (VAC) 60Hz CONTACTS N
MARYLAND

TYPE
VIRGINIA
H LOAD
terminals 2 and 3.
CALIFORNIA

OKLAHOMA ARKANSAS
TENNESSEE NORTH CAROLINA LINE
LINE
LOAD
34
ARIZONA NEW MEXICO SOUTH

Metal Indoor
CAROLINA
MISS
LOAD
SCHEDULING: Turn ON at sunset and OFF at TZ-220L* ** 120 DPDT TEXAS ALABAMA GEORGIA LINE
NEMA 1 LOUISIANA
LOAD

sunrise daily. OFF time can be set from 8:30PM Metal Indoor/outdoor 30
MEXICO

TZ-220L-O* ** 120 DPDT FLORIDA


MANUAL CONTROLS
to 2:30AM. Can be individually offset +/- 20 NEMA 3
or 40 minutes from both sunset and OFF times. Metal Indoor 18 HAWAII 18 PUERTO MANUAL CONTROLS

TZ-222L* ** 208 - 277 DPDT


NEMA 1
RICO
TZ220L
Available from 18 - 45 northern latitudes. TZ220L
Metal Indoor TIME Wiring shown is for
SKIP-A-DAY: Omit operations on any day with TZ-300L* ** 120 3PST M SWITCH CONTACTOR mechanically
Wiring shown isheld
for
NEMA 1 TIME CONTROL
contactors. Use
1
M
2 SWITCH CONTACTOR
CIRCUIT mechanically heldCLOSE
a 7 spoke wheel marked with days of the week. Metal Indoor/outdoor
3 4 5 6 7 8 9
CONTROL terminal only
contactors. Usefor
CLOSE
TZ-300L-O* ** 120 3PST 1 2 3 4 5 6 7 8 9 CIRCUIT COMMON
magnetically held
3 omitting screws included. NEMA 3 H N
OPEN
COMMON
terminal only for
CLOSE contactors and
magnetically heldto
Metal Indoor CONTACTOR OPEN
control direct
MANUAL OVERRIDE: Until the next TZ-302L* ** 208 - 277 3PST H N CONTROL COMMON
CLOSE contactors and loads
to not
NEMA 1 CONTACTOR
CIRCUIT
CONTROL OPEN
COMMON
exceeding
control direct2000
loadswatts.
not
regularly scheduled ON or OFF, automatic Replacement CIRCUIT CLOSE exceeding 2000 watts.
operation then resumes. For "L" models #36 (120V) & #46 (208-277V) OPEN
Motor CLOSE

Replacement
MANUAL BYPASS SWITCHES: Single pole, Bypass Switch #66061
20 Amps - one per circuit. Factory pre-wired to
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45).
terminal strip. ON/OFF/AUTO positions for each **Consult factory for UPC number.
circuit is independent, will not disturb automatic
settings. SPECIFICATION WRITERS GUIDE
RESERVE POWER: Standard feature on all Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The time switch shall
models keep dial on time up to 24 hours during be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 16 hours after power
power outage. failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at
sunset in (city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of
adjustability of 20 or 40 minutes before or after sunset and sunrise. Time switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously
at 277 volts and shall be DPST (3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching
to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA
1 surface type, finished in beige enamel, and with 12 - 34 combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
(Specify E door for manual switches to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to fit requirement).

ELECTROMECHANICAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 49 USA 800.321.5847 www.nsiindustries.com TORK 50
DIGITAL
TIME SWITCHES
FEATURES
QUICK LOOK
ENERGY/LIGHTING
LIGHTING CONTROLS CYCLE - SIGNAL TIMER
DTU40 DTWH40 E-PB E EW EWZ DG DGM DZS DTS DWZ CONTROLS
DW DZM ELC71/72 ELC74/78/712 DGU DGUM DGLC DLC400 DG DGS DIN
Page No. 55 55 57 57 59 61 63 63 65 67 69
Page No. 69 71 73 75 79 79 79 81 85 85 89
Number of Channels 1 1 1 1 or 2 1 or 2 1 or 2 1 or 2 1 1, 2, or 4 1, 2, or 4 1 Number of Channels 2 2 1 or 2 4, 8, or 12 1 1 1 or 2 4 1 or 2 1 1 or 2

ON/OFF Set Points 7 pair (98) 7 pair (98) 20 (140) 20 20 20 56 56 99 99 99 8 pair


ON/OFF Set Points 99 99 128 128 56 56 56 99 56 56
3 pair/ch
365 Day/7 Day Scheduling 7 day 7 day 24 hour 24 hour 7 day 7 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 365 Day/7 Day Scheduling 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 7/365 day 24 Hour 7 Day 7 Day
Automatic Daylight Automatic Daylight
Manual Manual Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Savings Adjustment Savings Adjustment
Leap Year Yes Yes Yes Yes Yes Yes Yes Yes Yes Leap Year Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Individual Holiday Schedules 24 24 24 Individual Holiday Schedules 24 24 26 26 24

Block Holiday 9 9 Block Holiday 10 10 9 9 9

Season Scheduling 4 4 Season Scheduling 4 4

Astronomic (Sunrise/Sunset) Yes Yes Yes Astronomic (Sunrise/Sunset) Yes Yes Yes Yes

Photosensor Input Photosensor Input Yes Yes Yes Yes Yes Yes

Remote Override Input Remote Override Input Yes Yes Yes Yes Yes Yes

User Defined Input User Defined Input Yes Yes

Signal/Pulse Duration Yes Yes Signal/Pulse Duration Yes Yes Yes Yes

Momentary for Contactors Option Option Option Yes Momentary for Contactors Yes Yes Yes Yes

Duty Cycle Duty Cycle Yes Yes Yes Yes

31 Day Cycle 31 Day Cycle Yes

Manual Override Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Manual Override Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Clock Format AM/PM AM/PM AM/PM AM/PM AM/PM AM/PM 12/24 12/24 12/24 12/24 12/24 Clock Format 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 12/24 AM/PM
Rechargeable Rechargeable 4 day Super 4 day Super 4 day Super 4 day Super 7 day Super 7 day Super 7 day Super 7 day Super 7 day Super 7 day Super 7 day Super 7 day Super 2 day Capacitor 7 day Super 7 day Super 7 day Super 6 month 7 day Super 7 day Super
Power Outage Backup Power Outage Backup 8 year battery
Battery Battery Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor 1 year battery Capacitor Capacitor Capacitor battery Capacitor Capacitor
Schedule Retention Schedule Retention
Battery Battery Permanent Permanent Permanent Permanent Permanent Permanent Permanent Permanent Permanent Permanent Permanent Capacitor Battery Permanent Permanent Permanent Permanent Permanent Permanent Battery
without power without power
Staggered Start Yes Yes Yes Yes Yes Yes Yes Yes Staggered Start Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Memory Module Yes Memory Module Yes Yes


Computer Programming Computer Programming
Yes Yes Yes Yes
Software Software
Output Contacts: Amps Output Contacts: Amps
40A 40A 30A 40A 40A 40A 20A 20A 30A/20A 30A/20A 30A 30A 30A 20A 20A 20A 20A 20A 30A 20A 20A 16A
Resistive or General Purpose Resistive or General Purpose
Contact Type: Dry Unpowered Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Contact Type: Dry
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Unpowered
120/208- 120/208- 120/208- 120/208- 120/208- 120/208- 120/208- 120/208-240/ 24/120/208 120/208-
Voltage Input AC 120 120-277 120-277 120-277 120-277 120-277 Voltage Input AC 120-277 120-277 120-277 120-277 120-277 120
240/277 240/277 240/277 240/277 240/277 240/277 240/277 277 240/ 277 240/277
Low Voltage Input Low Voltage Input 12VDC
12VDC 24VAC 24VAC All Models 24VAC
(select models) (select models) 24VAC
TORK 53 TORK 54
DT SERIES NEW! SPECIFICATIONS CONTACT RATINGS
AUTOMATIC VOLTAGE DETECTION MORE WIRING RATING
TYPE VOLTAGE
24 HOUR OR 7 DAY HOUR SPACE! INPUT VOLTAGE: 120/208-240/277 NO NC
TIME SWITCH VAC, 50/60 Hz (auto detection). DTWH40 is
120/240VAC (auto detection). Resistive 120-277VAC 40A 30A
NEW!
TERMINAL RANGE: #8 - #18AWG. Inductive 120-277VAC 30A 15A
OPERATING TEMPERATURE: 120VAC 30A 10A
Ballast
-31F to 116F (-35C to +47C). 277VAC 20A 10A
APPLICATIONS
POWER CONSUMPTION: 6VA Max. Tungsten 120VAC 15A
14HP/12FLA/30LRA
DTU40 ENCLOSURE: DTU40 polycarbonate Indoor/ Motor
120VAC 1HP/30FLA/90LRA
DTU40 240VAC 2HP/20FLA/60LRA 12HP/12FLA/33LRA
Pumps, motors, fans Outdoor NEMA 3R. DTWH40 polycarbonate 120VAC 720VA 290VA
Signs and lighting indoor NEMA 1 enclosure with clear cover. Both Pilot duty
240VAC 720VA 260VA
Water heaters with lockable hasp (see page 153 for enclosure
SAVE Resistive 28VDC 20A
Heating and air conditioning ENERGY! dimensions).
DTWH40 Avoid utility peak rates
Turn off when not needed Max above 104 120-277VAC 30A
DTWH40
Water Heaters
This timer turns OFF when rates DTU40
are high and turns OFF when no
Typical
Typical Wiring
Wiring Diagram,
Diagram, 120120/277VAC Application
VAC Application
one is home.
TIMER
SUPPLY
H N NC NO C NC NO C
LOAD LOAD
ORDERING INFO
L N N L N L
FEATURES CATALOG
NO.
UPC
CODE
TIMER SUPPLY
(VAC) 60Hz
NO. OF
CHANNELS
DRY CONTACTS
(UNPOWERED) Typical Wiring Diagram, 208-240 VAC Application

DTU40 24004 120/208-240/277 1 DPDT TIMER


SCHEDULING: 7 ON & OFF pairs of set points SUPPLY
for individual programs on each day of the H N NC NO C NC NO C
week. Minimum setting is 1 minute. DTWH40 24005 120/240 1 DPDT
WIRING DIAGRAMS LOAD
DAYLIGHT SAVING: Manual button push for
one hour adjustment. L1 L2 L1 L2

MANUAL OVERRIDE: Until the next


regularly scheduled ON or OFF, automatic DTWH40 DTU40
operation then resumes. Typical Typical
Wiring Wiring120
Diagram, Diagram, 120VAC
120/277VAC Application
Typical Wiring Diagram, VAC Application Typical
Typical Wiring
Wiring Diagram,
Diagram, 120120/277VAC Application
VAC Application
EXTERNAL MANUAL OVERRIDE: DTWH40 TIMER TIMER
only on clear door. Override without opening SUPPLY SUPPLY
case. H N NC NO C NC NO C H N NC NO C NC NO C

RANDOM MODE: Varies ON and OFF times to LOAD LOAD LOAD LOAD
create "lived-in" look when away.
L N N L N L L N N L N L
CLOCK FORMAT: AM/PM. Typical Wiring
Typical Diagram, 208-240
Wiring Diagram, VAC Application
240VAC Typical Wiring Diagram, 208-240 VAC Application
POWER OUTAGE BACKUP: Battery retains TIMER TIMER
SUPPLY SUPPLY
time and schedule.
H N NC NO C NC NO C H N NC NO C NC NO C
LOAD LOAD

L1 L2 L1 L2 L1 L2 L1 L2

DTWH40
Typical
Typical Typical
Wiring
Wiring Wiring120
Diagram,
Diagram, Diagram, 120VAC
120/277VAC Application
VAC Application
TIMER
SUPPLY
DIGITAL
H N NC NO C NC NO C
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC LOAD LOAD
TORK 55 USA 800.321.5847 www.nsiindustries.com TORK 56
L N N L N L
E & E-PB SERIES SPECIFICATIONS CONTACT RATINGS
MULTIPURPOSE CONTROLS BACK-UP WITHOUT BATTERY, E101B, E103B, E201B E120B E101PB
TYPE
1 OR 2 CHANNEL ECO FRIENDLY! TIMING ACCURACY: Line Frequency. VOLTAGE
RATING
NO NO
RATING
NC
VOLTAGE RATING
NO
24 HOUR TIME SWITCH INPUT VOLTAGE: General Purpose 120-277VAC 40A 30A 30A
120/240VAC 30A
E SERIES 277VAC 12A
120/240VAC 30A
120 - 277VAC, 50/60Hz (automatic detection). Inductive 120-277VAC 40A 30A 30A
277VAC 12A
E-PB 120VAC 30A 30A 10A 120VAC 20A
120VAC, 50/60Hz. Ballast
208-277VAC 20A 20A 10A 277VAC 6A
APPLICATIONS TERMINAL RANGE: #8 - #16AWG. Tungsten 120VAC 15A 15A 2A 120VAC 5A
E101B E120B
TIMER OPERATING TEMPERATURE:
SPST SPDT
Signs SUPPLY TIMER Pilot Duty 120-277VAC 720VA 720VA 720VA 120-277VAC 470VA
-40 to +149F (-40 to +65C). SUPPLY
E101B E120
Air conditioning 120VAC 1HP
SPST
1HP 1HP 120VAC 1HP
1 2 POWER
3 4CONSUMPTION: 6VA Max. TIMER
11 2HP 112HP 112HP
Lighting 1 2 3
Motor4
LOAD LOAD 208VAC
5
SUPPLY 240VAC 2HP TIME
SUPP
Sump pumps ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R
LOAD 240-277VAC 2HP 2HP 2HP
Ventilating fans L N
is standard
N
with lockable hasp (see page 153 for Resistive
N N
1
28VDC 2 3
30A 4
30A 30A 28VDC 20A 1
L N
enclosure dimensions).
120/277VAC 120/277VAC LOAD

L N N L
120/277VAC 120/2

WIRING DIAGRAMS
E103B
DPST
TIMER
SUPPLY
E101B E201B E120B E103B E101PB
CH 1 CH 2
1 2 3 4 5 SPST
6 SPST SPST SPDT
TIMER
DPST SPST
TIMER TIMER
TIMER
SUPPLY TIMER SUPPLY SUPPLY
SUPPLY SUPPLY
ORDERING INFO LOAD LOAD E201B
CH 1
3 4 5 1 2 3 4 5 6 SP
1N 2 3 4 1 2 6 1 2 3 4
N 1 2 3 4 5 TIMER
CATALOG UPC INPUT SUPPLY NO. OF OUTPUT L N L LOAD LOAD
FEATURES NO. CODE (VAC) 50/60Hz CHANNELS DRY CONTACTS 120/277VAC
LOAD
LOAD LOAD
LOAD LOAD
SUPPLY
LOAD
DPST
TIMER 1 2 3
SUPPLY L N N L N
SCHEDULING: 20 ON/OFF set points repeat E101B 82401 120-277 1 SPST L N N
L N N L N
L N
N 120/277VAC N L N N LOAD
120/277VAC
120/277VAC 120/277VAC 120VAC
each day. Minimum setting 1 minute. 1 2 3 4 5 6 TIMER
DPST
E103B 82411 120-277 1 DPST SUPPLY L N
MOMENTARY CONFIGURATION
DAYLIGHT SAVING: Automatic adjustment E101B E120B TIMER CH 1 120/277VAC
SPST SUPPLY
(can be omitted). E120B 82406 120-277 1 TIMER SPDT SPDT
1 2 3 4 5 6
SUPPLY L1 L2 TIMER
SUPPLY
LOAD MOMENTA
208 OR 240VAC
LEAP YEAR: Automatic Compensation. E201B 82466 120-277 2 SPST E103B 1 2 3 4 5 6 TIMER
SUPPLY
C

1 2 3 4 1
TIMER 2 3 4DPST 5
MANUAL OVERRIDE: Until the next SUPPLY LOAD LOAD L1 L2
E101PB 82401 120-277 1 SPST 208 OR 240VAC LOAD
regularly scheduled ON or OFF, automatic LOAD
L N PULSE ON E201B
PULSE OFF
1 2 3 4
CH 1 CH 2
operation then resumes. L N N
1 2 3 4 5 6 120/277VAC E201B ONLY: UNIT MUST
BE CONFIGURED FOR SPST SPST
L N N N MOMENTARYTIMER
OPTION.
120/277VAC 120/277VAC SUPPLY
CLOCK FORMAT: AM/PM. LOAD LOAD
L N PULSE O

120/277VAC E201B O

POWER OUTAGE BACKUP: Permanent 3 4 5


1 2 6 BE CON
L N N L N LOAD LOAD MOMEN

schedule retention. Supercapacitor provides 120/277VAC


DPST
4 days of real time backup. TIMER
E103B SUPPLY L N N L N
MOMENTARY OPTION: For mechanically TIMER
DPST 120/277VAC

held contractors: Model E201B only. Configure SUPPLY


1 2 3 4 5 6
E201B
with simple jumper change for single-channel SPECIFICATION
MOMENTARY CONFIGURATION

SPST WRITERS GUIDE


CH 1 CH 2 TIMER
1 2 3 4 5 6 CH 1
SPST
momentary operation. TIMER
E100B only 1. Furnish and install a TORK digital time switch with
SUPPLY
(40 Amp SPST contacts, model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT
SUPPLY
L1 L2
LOAD LOAD contacts, model
208 OR 240VAC
E120B). 2. Unit
LOAD shall be capable of 20 set points. 3. Unit
1
shall
2
repeat
3
the
4
same
5
schedule
6
each day. 4. (Model E201B ONLY) Unit shall be capable of being
L N N L N
1 2 a32 channel
LOAD
4 maintained
5 or6 a 1 channel momentary 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. Unit shall program in AM/PM
LOAD
120/277VAC format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super capacitor for 100 hours in a
TIMER
DPST power failure. 10. Unit shall be capable of manual override ON or OFFL either N
to thePULSE
nextONscheduled event or permanently. 11. Unit shall have a NEMA 3R Indoor/Outdoor
PULSE OFF
SUPPLY L N plastic enclosure.
N L 12. Unit Nshall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model E101B (E103B) (E120B)
120/277VAC E201B ONLY: UNIT MUST
120/277VAC BE CONFIGURED FOR
(E201B). MOMENTARY OPTION.
1 2 3 4 5 6
MOMENTARY CONFIGURATION
TIMER CH 1
SUPPLY

DIGITAL L1 L2
208 OR 240VAC LOAD 1 2 3 4 5 6
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 57 USA 800.321.5847 www.nsiindustries.com TORK 58
L N PULSE ON PULSE OFF
EW SERIES SPECIFICATIONS CONTACT RATINGS
MULTIPURPOSE CONTROL AUTOMATIC DST - SAVES TIME EW101B, EW103B, EW201B EW120B
1 OR 2 CHANNEL CHANGES TWICE A YEAR TIMING ACCURACY: Line Frequency.
TYPE
VOLTAGE
RATING
VOLTAGE
RATING
NO NO NC
7 DAY TIME SWITCH
INPUT VOLTAGE: General Purpose 120-277VAC 40A 120-277 VAC 30A 30A
120 - 277VAC, 50/60Hz (automatic detection).
Inductive 120-277VAC 40A 120-277 VAC 30A 30A
TERMINAL RANGE: #8 - #16AWG.
responsible
energy 120VAC 30A 120VAC 30A 10A
OPERATING TEMPERATURE: Ballast
208-277VAC 20A 208-277VAC 20A 10A
APPLICATIONS CALIFORNIA Title 24 -40 to +149 (-40 to +65C).
ASHRAE 90.1 Tungsten 120VAC 15A 120VAC 15A 2A
POWER CONSUMPTION: 6VA Max.
Outdoor signs
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R. Pilot Duty 120-277VAC 720VA 120-277 VAC 720VA 720VA
Lighting security EW101B EW
Heating and air conditioning Suffix -C plastic clear cover Indoor/Outdoor NEMAEW120B
EW101B
120VAC 1HP TIMER 120VAC
SPST 1HP 1HP
3R. Suffix SPST
TIMER -Y metal Indoor enclosure NEMA 1. All TIMER SPDT
Motor 208VAC 112HPSUPPLY 208VAC 112HP 112HP
TIM
SUPPLY SU
with lockable hasp (see page 153 for enclosure SUPPLY 240-277VAC 2HP 240-277VAC 2HP 2HP
1
dimensions).
2 3 4 3 4 5
1 2 3 4 1
1 2
LOAD LOAD Resistive 28VDC 30A 28LOAD
VDC 30A 30A
LOAD

L N N L
L N N L N N N
120/277VAC WIRING DIAGRAMS 120/277VAC
120/277VAC 120

EW101B EW120B
EW103B EW201B
EW201B
SPST SPDT
DPST CH 1 CH 2
CH 1
TIMER CH 2 TIMER SPST SPST
SPST
SUPPLY SPST SUPPLYTIMER
SUPPLY

ORDERING INFO 1 2 3 4 1 2
1
3
2 3
4 5
4
6
5
LOAD LOAD

FEATURES CATALOG UPC INPUT SUPPLY NO. OF OUTPUT LOAD LOAD LOAD
NO. CODE (VAC) 50/60Hz CHANNELS DRY CONTACTS
L N N L N
L N N L N N N
120/277VAC
EW101B 82431 120-277 1 SPST 120/277VAC 120/277VAC
SCHEDULING: 20 ON & OFF set points DPST
TIMER
for individual programs for each day of the SUPPLY momentary configuration
EW103B 82441 120-277 1 DPST momentary configuration
week. Minimum setting is 1 minute. CH 1 EW103B TIMER
CH 1
EW101B TIMER EW120B
EW201B 1 2 3 4 5 6 SUPPLY
SUPPLY
DAYLIGHT SAVING: EW120B 82436 120-277 1 SPDT SPST CH 1
SPDT CH 2 TIMER
DPST
TIMER SPST SPST SUPPLY
Automatic (can be omitted). SUPPLY
1 2 3
TIMER
4
SUPPLY 5 6
1 2 3 4 5 6
EW201B 82467 120-277 2 SPST
LEAP YEAR: Automatic Compensation. L1 L2 1 2
LOAD
3 4 5 6
1 2 3 4 1 2 3 4 5 208 OR 240VAC
EW103B-C 82253 120-277 1 DPST LOAD LOAD PULSE ON PULSE OFF
MANUAL OVERRIDE: Until the next LOAD L N
PULSE ON PULSE OFF LOAD L LOAD
N
120/277VAC
regularly scheduled ON or OFF, automatic EW103B-Y 82255 120-277 1 DPST 120/277VAC EW201B ONLY: UNIT MUST BE
EW201B ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CONFIGURED FOR MOMENTARY OPTION L N N L N
operation then resumes. L N N L N N N 120/277VAC
EW120B-C 82437 120-277 1 SPDT 120/277VAC 120/277VAC
CLOCK FORMAT: AM/PM. TIMER
DPST
SUPPLY
momentary configuration
POWER OUTAGE BACKUP: Permanent EW120B-Y 82261 120-277 1 SPDT CH 1
schedule retention. Supercapacitor provides 4 EW201B
TIMER
SUPPLY
EW103B 1 2 3 4 5 6

days of real time backup. EW201B-Y 82299 120-277 2 SPST CH 1 CH 2 TIMER


DPST
SPST SPST 3
SUPPLY
4 5 6
1 2
MOMENTARY OPTION: For mechanically
held contractors: Model EW201B only. Configure SPECIFICATION 1WRITERS 2 3 GUIDE 4 5 6
L1
LOAD
L2
208 OR 240VAC
with simple jumper change for single-channel EW SERIES 1. Furnish and installON
a TORKPULSE
digital OFF
time switch with (40 Amp SPST contacts, model EW101B, EW210B) (40 Amp DPST contacts, model EW103B) (30 Amp
PULSE
momentary operation. L
SPDT contacts, N
model EW120B). 2. Unit shall
LOAD
be capable of 20 set points.
LOAD
3. Unit shall be capable of a different schedule each day of the week. 4. (Model EW201B ONLY)
120/277VAC EW201B ONLY: UNIT MUST BE
Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6.
CONFIGURED FOR MOMENTARY OPTION
L N N L N
Unit shall program in AM/PM format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super
120/277VAC
capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have
DPST
a NEMA 3R Indoor/OutdoorSUPPLYplastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model
TIMER
momentary configuration
EW101B (EW103B) (EW120B) (EW201B).
CH 1
TIMER
SUPPLY 1 2 3 4 5 6

1 2 3 4 5 6
DIGITAL
L1 L2
CONTROLS 208 OR 240VAC
LOAD
A DIVISION OF NSi INDUSTRIES, LLC
PULSE ON PULSE OFF
TORK 59 USA 800.321.5847 www.nsiindustries.com L N TORK 60
120/277VAC EW201B ONLY: UNIT MUST BE
EWZ SERIES SPECIFICATIONS CONTACT RATINGS
MULTIPURPOSE CONTROL PREFERRED FOR EWZ101,EWZ103, EWZ201 EWZ120
1 OR 2 CHANNEL, ASTRONOMIC OUTDOOR LIGHTING TIMING ACCURACY: Line Frequency. TYPE
VOLTAGE
RATING
VOLTAGE
RATING
NO NO NC
7 DAY TIME SWITCH INPUT VOLTAGE:
General Purpose 120-277VAC 40A 120-277 VAC 30A 30A
120 - 277VAC, 50/60Hz (automatic detection).
TERMINAL RANGE: #8 - #16AWG. Inductive 120-277VAC 40A 120-277 VAC 30A 30A
responsible
energy
OPERATING TEMPERATURE: 120VAC 30A 120VAC 30A 10A
Ballast
CALIFORNIA Title 24 -40 to +149 (-40 to +65C). 208-277VAC 20A 208-277VAC 20A 10A
APPLICATIONS
ASHRAE 90.1 Tungsten 120VAC 15A 120VAC 15A 2A
POWER CONSUMPTION: 6VA Max.
Outdoor signs
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R Pilot Duty 120-277VAC 720VA 120-277 VAC 720VA 720VA
Lighting security is standard with lockable hasp (see page 153 forEWZ120 EWZ101 EW
EWZ101
Heating and air conditioning enclosure
SPSTdimensions).Suffix -MB without enclosure SPDT
120VAC 1HPTIMER 120VAC
SPST 1HP 1HP
TIMER
112HP 112HP 112HP
TI
SUPPLY
and includes mounting bracket. TIMER Motor 208VAC SUPPLY 208VAC SU
SUPPLY
240-277VAC 2HP 240-277VAC 2HP 2HP
1 2 3 4 1
1 2 3 4 1 2 3 4 5
LOAD LOAD Resistive 28VDC 30A 28 VDC
LOAD
30A 30A
LOAD

L N N L
L N N L N N N
120/277VAC WIRING DIAGRAMS120/277VAC 120/277VAC 120

EWZ201 EWZ101 EWZ120


EWZ103 EWZ201
SPST DPST
SPDT CH 1 CH 2
CH 1
TIMER CH 2 TIMER
SPST SPST
SPST
SUPPLY SPST TIMER
SUPPLY
SUPPLY

ORDERING INFO 1 2 3 4
1
1
2 3
2 3
4
4
5 6
5
LOAD LOAD

FEATURES CATALOG UPC INPUT SUPPLY NO. OF OUTPUT LOAD LOAD LOAD

NO. CODE (VAC) 50/60Hz CHANNELS DRY CONTACTS


L N N L N
L N N L N N N
120/277VAC
SCHEDULING: 20 ON & OFF set points EWZ101 82470 120-277 1 SPST 120/277VAC 120/277VAC
DPST
TIMER
for individual programs for each day of the SUPPLY momentary configuration
week. Minimum setting is 1 minute. EWZ103 82473 120-277 1 DPST momentary configuration
CH 1
EWZ101 EWZ120 CH 1
EWZ103 TIMER
TIMER EWZ201 1 2 3 4 5 6 SUPPLY
SUPPLY
ASTRONOMIC: Adjustable 10 - 60 EWZ120 82471 120-277 1 SPDT TIMER
SPST SPDT
CH 1 CH 2 TIMER
DPST
TIMER SPST SPST
Northern or Southern latitudes. Can be SUPPLY
SUPPLY
SUPPLY
1 2 3 4 5 6
1 2 3 4 5 6
individually offset +/- 1-240 minutes EWZ201 82472 120-277 2 SPST
L1 L2 3 4 5 6
from both sunset and sunrise times. 1 2 3 4 1 2 3 4 5 208 OR 240VAC
1 2
LOAD
LOAD LOAD
EWZ101-MB 82263 120-277 1 SPST PULSE ON PULSE OFF
DAYLIGHT SAVING: Automatic LOAD L N
PULSE ON PULSE OFF LOAD LOAD
L N
120/277VAC EWZ201 ONLY: UNIT MUST BE
(can be omitted). EWZ103-MB 82269 120-277 1 DPST
120/277VAC EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
CONFIGURED FOR MOMENTARY OPTION
L N N L N
L N N L N N N
120/277VAC
LEAP YEAR: Automatic Compensation. 120/277VAC 120/277VAC
EWZ120-MB 82275 120-277 1 SPDT DPST
TIMER
MANUAL OVERRIDE: Until the next SUPPLY
momentary configuration
regularly scheduled ON or OFF, automatic EWZ201-MB 82281 120-277 2 SPST CH 1
operation then resumes. EWZ201 TIMER EWZ103
SUPPLY 1 2 3 4 5 6
DPST
CH 1 CH 2 TIMER
CLOCK FORMAT: AM/PM. SPST SPST SUPPLY
1 2 3 4 5 6
POWER OUTAGE BACKUP: Permanent
schedule retention. Supercapacitor provides 4 days
SPECIFICATION 1 WRITERS
2 3 GUIDE
4 5 6 L1 L2
LOAD
208 OR 240VAC
of real time backup. EWZ SERIES 1. Furnish and
PULSE ON
install TORK digital
PULSE OFF
time switch with (40 AMP contacts, models EWZ101, EWZ201) (40 Amp DPST contacts, model EWZ103) (30 AMP
LOAD LOAD
contacts,
L
model
N
EWZ120). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule for each day of the week. 4. Unit shall be have
120/277VAC EWZ201 ONLY: UNIT MUST BE
MOMENTARY OPTION: For mechanically held astronomic option adjustable
CONFIGUREDfrom
FOR1- 60 northern
MOMENTARY OPTION or southern latitudes. 5. Unit shall be have astronomic option with offset up to 4 hours and 59 minutes, before or
L N N L N
contactors: Model EWZ201 only. Configure after sunrise. 6. (Model EWZ201 ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 7. Unit shall have automatic Daylight Savings
120/277VAC
with simple jumper change for single-channel Time and Leap Year compensation. 8. Unit shall program in AM/PM format. 9. Display shall be of LCD type. 10. Unit shall have permanent schedule retention. 11. Unit
DPST
momentary operation. TIMER
real time clock shall beSUPPLY
retained by capacitor for 100 hours in a power failure. 12. Unit shall be capable of manual override ON or OFF either in the next scheduled event
momentary configuration
CH 1
or permanently. 13. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 14. Unit shall have Load Status indication. 15. Unit shall have Power Failure
TIMER
SUPPLY
indication. 16. To order1specify
2 TORK 3 Model EWZ101
4 5 (EWZ103) 6 (EWZ120) (EWZ201).

1 2 3 4 5 6
DIGITAL L1 L2
CONTROLS 208 OR 240VAC
LOAD

A DIVISION OF NSi INDUSTRIES, LLC PULSE ON PULSE OFF


L N
TORK 61 USA 800.321.5847 www.nsiindustries.com TORK 62
120/277VAC EWZ201 ONLY: UNIT MUST BE
CONFIGURED FOR MOMENTARY OPTION
DG100 SERIES SPECIFICATIONS CONTACT RATINGS
MULTIPURPOSE CONTROLS NEW! HOLIDAY PROGRAMMING RATING
TYPE VOLTAGE
1 OR 2 CHANNEL FOR MORE SAVINGS! TIMING ACCURACY: Line Frequency.
NO NC
365/7 DAY INPUT VOLTAGE: Resistive 24-277VAC 20A 10A
TIME SWITCH 120 - 277VAC, 50/60Hz (automatic detection).
120 VAC
Ballast 20A 10A
TERMINAL RANGE: #12 - #18AWG. 277 VAC

OPERATING TEMPERATURE: Tungsten 120VAC 15A


-31 to +131F (-35 to +55C).
APPLICATIONS CALIFORNIA Title 24 Pilot Duty
120VAC
720VA
290VA
POWER CONSUMPTION: 6VA Max. 240VAC 360VA
ASHRAE 90.1 14HP
120VAC 1HP
Motor
Indoor/Outdoor lighting ENCLOSURE: Noryl Indoor/Outdoor NEMA 240VAC 2HP 12HP

HVAC equipment 3R. Suffix -Y metal indoor enclosure NEMA 1. All Resistive 28VDC 20A 10A
School warning and other with lockable hasp (see page 153 for enclosure
Traffic lights dimensions).
Water heaters in offices,
churches and factories

WIRING DIAGRAMS

DGM100A DG200A

ORDERING INFO
CATALOG UPC INPUT SUPPLY NO. OF OUTPUT
FEATURES NO. CODE (VAC) 50/60Hz CHANNELS CONTACTS

DG100A 82201 120-277VAC 1 DPDT


SCHEDULING: 56 ON & OFF set points
provide individual programs for each day of DG200A 82209 120-277VAC 2 SPDT
the week. Minimum setting is 1 minute.
SPDT
MOMENTARY CONTACT: DGM100A has 2 DGM100A 82210 120-277VAC 1 Momentary
second contact closures for ON & OFF control of SPDT
DGM100A-Y 82222 120-277VAC 1
mechanically held contactors or latching relays. Momentary
DG100A
BLOCK HOLIDAY: 9 holiday blocks can be
set for individual days or for duration of any
number of days.
DAYLIGHT SAVING: Automatic
adjustment (can be omitted).
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next
regularly scheduled ON or OFF, automatic
operation then resumes.
CLOCK FORMAT: AM/PM or 24 Hour
format. SPECIFICATION WRITERS GUIDE
DG100/200A SERIES 1. Furnish and install, where noted, a 1 (2) channel 7-day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or
POWER OUTAGE BACKUP: Permanent
Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast loads at 277VAC. 4. Controller shall be capable fo 56 set points; separate scheduling for
schedule retention is provided. Supercapacitor
each day of the week with one minute resolution. 5. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of
provides 7 days of real time back up.
days. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 7. Controller shall have automatic Leap Year correction.
8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10.
Controller shall be capable of Manual Override ON or OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA Type 3R indoor/outdoor
enclosure as standard. 12. To order specify TORK Model DG100A (DG200A). 13. To order momentary contact closure for latching contactor control specify DGM100A.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 63 USA 800.321.5847 www.nsiindustries.com TORK 64
DZM200B

DZS SERIES
GND NO C NC NO C NC
UPPER
SPECIFICATIONS TIMER SUPPLY C ON OFF C ON OFF
CONTACT RATINGS
REMOVABLE MEMORY BOARD

MULTIPURPOSE CONTROLS DZS100BP, DZS200BP DZS400BP


MODULE FOR COMPUTER
L L
N 120 208-240277

TYPE RATING RATING


1, 2 OR 4 CHANNEL
L LOADL LOAD
DZS400BP
TIMING ACCURACY:
120V
Line frequency. VOLTAGE VOLTAGE
PROGRAMMING!
N N
208-240V
PULSE PULSE PULSE PULSE
NO NC NO NC
365 / 7 DAY ADVANCED
ON OFF ON OFF

INPUT VOLTAGE: 120/208-240/277VAC, 277V N


CH 1
SPDT
N
CH 2
SPDT General Purpose 24-277VAC 30A 30A 24-277VAC 20A 20A
TIME SWITCH 50/60Hz.
AC LINE INPUT
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS

120VAC 30A 10A


NO C NC NO C NC Ballast 120-277VAC 13A
TERMINAL RANGE: LOWER
TIMER SUPPLY
277VAC 20A 10A
responsible
energy #14-#16AWG for line input. BOARD

#12-#16AWG load outputs.


N

120V
120 208-240 277

L L
Tungsten 120-277VAC 15A 2A 120VAC 8A
APPLICATIONS CALIFORNIA Title 24 AC LINE INPUT 208-240V
LOAD LOAD
120VAC
DZM200B 1HP 1HP
CH 1 CH 2

ASHRAE 90.1
OPERATING TEMPERATURE: SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE 277V
N N
Motor Load 120-277VAC 1HP 1HP
-40 to +158F (-40 to 70C). 208-277VAC 2HP 2HP
HVAC equipment TIMER SUPPLY C ON OFF C ON OFF

Horns and bells POWER CONSUMPTION: Pilot Duty 120-277VAC 720VA 720VA 12-277VAC 720VA 720VA
CH 3 CH 4

Interior lighting 5VA Max: DZS100/200BP. SPDT SPDT


N 120 208-240277

6VA Max: DZS400BP. Resistive 28VDC120V 30A L 30A L

Electric motors 208-240V


PULSE PULSE PULSE PULSE
GND NO C NC NO C NC ON OFF ON OFF
Outdoor lighting ENCLOSURE: Noryl Indoor/Outdoor NEMA

UPPER CH 1 CH 2 277V N N
BOARD SPDT SPDT
and signs 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All AC LINE INPUT
SELECT PROPER TERMINALS
MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
AND APPLY ONLY ONE VOLTAGE
with lockable hasp (see page 153 for enclosure L L

ORDERING INFO dimensions). DZS400BP


DZS200BP
TIMER SUPPLY C
N
LOADNC
NO C
N
LOAD
NO NC

FEATURES CATALOG UPC TIMER SUPPLY NO. OF DRY CONTACTS N 120 208-240 277
CH 1 CH 2
NO. CODE (VAC) 50/60Hz CHANNELS (UNPOWERED) 120V SPDT SPDT

WIRING DIAGRAMS AC LINE INPUT


SELECT PROPER TERMINALS
208-240V
L
LOAD
L
LOAD

SCHEDULING: 99 ON & OFF set points DZS100BP 82182 120/208-240/277 1 DPDT AND APPLY ONLY ONE VOLTAGE 277V
TIMER SUPPLY
N
NO C NC
N
NO C NC

allow individual programs for each day of LOWER


BOARD
DPDT

the week at a minimum 1 minute apart. DZS200BP 82183 120/208-240/277 2 SPDT N 120 208-240 277

120V L L CH 3 CH 4
LOAD LOAD SPDT SPDT
ASTRONOMIC: Adjustable 10 - 60 Northern or DZS400BP 82184 120/208-240/277 4 SPDT
208-240V
AC LINE INPUT TIMER SUPPLY C NO NC C NO NC
DZS100BP SELECT PROPER TERMINALS N N

Southern latitudes can be individually offset +/-1 to AND APPLY ONLY ONE VOLTAGE 277V

N
240 minutes from both sunset and sunrise times.
120 208-240 277
GND NO C NC NO C NC
Memory Module UPPER
USB-MMP 82196 Includes software 120V

Programmer AC LINE INPUT 208-240V


L L BOARD
SEASONS: 1 to 4 with different daily schedules SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE 277V
N
LOAD
N
LOAD
L L
which can wrap around into the new year. DZS100BP-0 82215 120/208-240/277 1 DPDT LOAD LOAD
DZS400BP N N
HOLIDAYS: 1 to 24 individual dates. DZS200BP-0 82227 120/208-240/277 2 SPDT CH 1 CH 2 CH 1 CH 2
SPDT SPDT SPDT SPDT
SIGNAL/PULSE DURATION: 2 different
settings per channel: 1-99 seconds. DZS200BP-12 82228 12VDC 2 SPDT
TIMER SUPPLY C NO NC C NO NC TIMER SUPPLY NO C NC NO C NC

DAYLIGHT SAVING: Automatic adjustment DZS200BP LOWER


DZS200BP-24 82229 24VAC 2 SPDT BOARD
(can be omitted). N 120 208-240 277 N

120V
120 208-240 277

L L
120V
DZS400BP-0 82230 120/208-240/277 4 SPDT L L LOAD LOAD
LEAP YEAR: Automatic Compensation. AC LINE INPUT
SELECT PROPER TERMINALS
208-240V
LOAD LOAD
AC LINE INPUT
SELECT PROPER TERMINALS
208-240V

277V
N N
AND APPLY ONLY ONE VOLTAGE 277V AND APPLY ONLY ONE VOLTAGE
N N

MANUAL OVERRIDE: Until the next regularly DPDT


scheduled ON or OFF, automatic operation then
resumes. In signal mode, activates pulse.
TIMER SUPPLY C NO NC C NO NC

CLOCK FORMAT: AM/PM or Military time. DZS100BP


SPECIFICATION WRITERS GUIDE N 120 208-240 277

POWER OUTAGE BACKUP: Permanent schedule 120V CH 1 CH 2


DZS SERIES 1. Furnish and install, where noted, a 4L (2) (1)LOAD
channel
L digital time switch with portable Memory Module on front panel.SPDT 2. MemorySPDT Module shall be
retention with memory module. Supercapacitor AC LINE INPUT 208-240V
LOAD
capable of being programmed at any one location and inserted into DZS100BP, 200BP, 400BP Series (with memory module socket) in any other remote location.
SELECT PROPER TERMINALS
277V
provides 7 days of real time backup.
AND APPLY ONLY ONE VOLTAGE N N

3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication C of NC
NO MemoryC NO Modules
NC or TIMER SUPPLY
DZS200BP
MEMORY MODULE: Removable MM can be individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another
programmed at any one location and inserted into without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in
N

120V
120 208-240 277

another DZS series unit. one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each
L
day ofLOAD
theL week. LOAD
9. Controller shall AC LINE INPUT 208-240V
SELECT PROPER TERMINALS

COPY FEATURE: Unit can be configured to copy have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within
N N
each season.
AND APPLY ONLY ONE VOLTAGE 277V

program schedule to multiple memory modules. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall haveDPDT Permanent Schedule
Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of manual override ON or OFF to the next
OPTION: Memory Module Programmer with Scheduled event using 1 button for each channel. 16. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 17. Controller shall
C NO NC beC capable
NO NCof having TIMER SUPPLY
software for computer connection programming. Also 2 different pulse durations 1-99 seconds, user settable and assignable to each channel. DZS100BP
18. Controller shall be capable of having astronomic on one (or all) channels
allows stand alone battery operation for portable
with 1-240 minutes, plus or minus offset from Sunrise or Sunset. 19. Controller shall be capable of being configured to copy to multiple memory modules. 20. To order N 120 208-240 277

copy feature. 120V

specify TORK Model DZS100BP (DZS200BP) (DZS400BP). L


LOAD
L
LOAD
AC LINE INPUT 208-240V
SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE 277V
N N

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 65 USA 800.321.5847 www.nsiindustries.com TORK 66
L L

DTS SERIES DTS400B


SPECIFICATIONS N
LOAD
N
LOAD
CONTACT RATINGS
MULTIPURPOSE CONTROLS MAINTAINED AND CH 1 CH 2
DTS100B, DTS200B DTS400B
RATING RATING
1, 2 OR 4 CHANNEL SIGNAL TIMING TIMING ACCURACY: Line Frequency.
SPDT SPDT TYPE VOLTAGE NO NC VOLTAGE NO NC
365 / 7 DAY ADVANCE General
NC Purpose 24-277VAC 30A 30A 24-277VAC 20A 20A
INPUT VOLTAGE: 120/208-277VAC, TIMER SUPPLY NO C NC NO C
TIME SWITCH 50/60Hz.
LOWER
BOARD 120VAC 30A 10A
N 120 208-240 277 Ballast 120-277VAC 13A
TERMINAL RANGE: 120V L L 277VAC 20A 10A
LOAD LOAD
#14 - #16AWG for lineSELECT
input. AC LINE INPUT
PROPER TERMINALS
208-240V
N N Tungsten 120-277VAC 15A 2A 120VAC 8A
#12 - #16AWG load outputs.
AND APPLY ONLY ONE VOLTAGE 277V

APPLICATIONS CALIFORNIA Title 24


Pilot Duty 120-277VAC 720VA 720VA 12-277VAC 720VA 720VA
ASHRAE 90.1 OPERATING TEMPERATURE: CH 3 CH 4
SPDT SPDT
Indoor and outdoor lighting -40 to +149 (-40 to +65C). 120VAC 1HP 1HP
Motor Load 120-277VAC 1HP 1HP
Heating and air conditioning 208-277VAC 2HP 2HP
POWER CONSUMPTION: 6VA Max.
Security systems UPPER
GND NO C NC NO C NC
Resistive 28VDC 30A 30A
Horns and bells ENCLOSURE: Noryl Indoor/Outdoor NEMABOARD
Low voltage lighting 3R with lockable hasp (see page 153 for enclosure
CH 1
SPDT L
CH 2
SPDT L

Misting and spraying dimensions). LOAD LOAD


DTS400B
Roof cooling N N
TIMER SUPPLY C NO NC C NO NC
Clock correction systems DTS200B CH 1 CH 2
SPDT SPDT
Process functions
WIRING DIAGRAMS
N 120 208-240 277

120V
L L
AC LINE INPUT 208-240V
TIMER SUPPLY NO C NC NO C NC
SELECT PROPER TERMINALS LOAD LOAD
LOWER
AND APPLY ONLY ONE VOLTAGE 277V
N N
BOARD
N 120 208-240 277
DPDT
120V L L
LOAD LOAD
AC LINE INPUT 208-240V CH 3 CH 4
SELECT PROPER TERMINALS N N SPDT SPDT
AND APPLY ONLY ONE VOLTAGE 277V

ORDERING INFO DTS100B


TIMER SUPPLY C NO NC C NO NC

GND NO C NC NO C NC
CATALOG UPC TIMER SUPPLY NO. OF DRY CONTACTS
FEATURES NO. CODE (VAC) 50/60Hz CHANNELS (UNPOWERED)
N

120V
120 208-240 277 UPPER
BOARD
L L
AC LINE INPUT 208-240V
LOAD LOAD L L
SELECT PROPER TERMINALS
DTS100B 82185 120/208-240/277 1 DPDT 277V
SCHEDULING: 99 ON/OFF set points AND APPLY ONLY ONE VOLTAGE N N
DTS400B N
LOAD
N
LOAD

allow individual programs for each day DTS200B 82186 120/208-240/277 2 SPDT CH 1 CH 2
of the week at a minimum 1 minute apart. SPDT SPDT
CH 1
SPDT
CH 2
SPDT

SEASONS: 1 to 4 with different daily DTS400B 82187 120/208-240/277 4 SPDT


schedules which can wrap around into the new DTS200B
TIMER SUPPLY C NO NC C NO NC TIMER SUPPLY NO C NC NO C NC
LOWER
year. BOARD
N 120 208-240 277 N 120 208-240 277

HOLIDAYS: 1 to 24 individual dates. 120V


L L
120V
LOAD
L
LOAD
L

208-240V AC LINE INPUT 208-240V


AC LINE INPUT
LOAD LOAD SELECT PROPER TERMINALS N N
SIGNAL/PULSE DURATION: 2 different SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE 277V
N N
AND APPLY ONLY ONE VOLTAGE 277V

settings per channel: each 1-99 seconds. DPDT

DAYLIGHT SAVING: Automatic adjustment


(can be omitted). TIMER SUPPLY C NO NC C NO NC

LEAP YEAR: Automatic Compensation. DTS100B


N 120 208-240 277
CH 1 CH 2
MANUAL OVERRIDE: Until the next 120V
L L
SPDT SPDT

regularly scheduled ON or OFF, automatic AC LINE INPUT


SELECT PROPER TERMINALS
208-240V
LOAD LOAD

SPECIFICATION WRITERS GUIDE


277V
operation then resumes. In signal mode, AND APPLY ONLY ONE VOLTAGE N N
C NO NC C NO NC TIMER SUPPLY

activates pulse. DTS SERIES 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch.DTS200B
2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each N 120 208-240 277

CLOCK FORMAT: AM/PM or Military time. 120V


day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasonsACofLINEunlimited
INPUT
duration. 7. Different
L dailyL schedules shall be 208-240V

POWER OUTAGE BACKUP: Permanent programmable within each season. 8. Controller shall have Daylight Saving or Standard time. AND9.APPLY
Controller
ONLY ONEshall have automatic Leap Year Ncorrection.
SELECT PROPER TERMINALS
VOLTAGE
LOAD
10.
N
Controller shall
LOAD
277V

schedule retention. Supercapacitor provides have Permanent Schedule Retention. 11. Controller shall have 7 day backup for real time with built in super capacitor. 12. Controller shall be capable DPDT
of manual override
7 days of real time back up. ON to activate pulse #1 duration. 13. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 14. Controller shall be capable of having two different pulse
durations 1-99 seconds, user settable and assignable to each channel. 15. To order specify TORK Model DTS100B (200B) (400B).
TIMER SUPPLY C NO NC C NO NC
DTS100B
N 120 208-240 277

120V

DIGITAL
L L
AC LINE INPUT 208-240V
SELECT PROPER TERMINALS
LOAD LOAD

CONTROLS
AND APPLY ONLY ONE VOLTAGE 277V
N N

A DIVISION OF NSi INDUSTRIES, LLC


TORK 67 USA 800.321.5847 www.nsiindustries.com TORK 68
DW SERIES SPECIFICATIONS CONTACT RATINGS
MULTIPURPOSE CONTROLS SPECIFICATION RATING
TYPE VOLTAGE
365 / 7 DAY ADVANCED FAVORITE! TIMING ACCURACY: Line Frequency. NO NC
1 OR 2 CHANNEL TIME General Purpose 24-277VAC 30A 30A
INPUT VOLTAGE:
SWITCHES 120/208-240-277VAC, 50/60Hz. 120VAC 30A 10A
Ballast
277VAC 20A 10A
TERMINAL RANGE:
#14 - #16AWG for line input. Tungsten 120-277VAC 15A 2A
#12 - #16AWG load outputs.
APPLICATIONS Pilot Duty 120-277VAC 720VA 720VA
OPERATING TEMPERATURE:
120VAC 1HP 1HP
1 CHANNEL -40 to +158(-40 to 70C). Motor Load
208-277VAC 2HP 2HP
Outdoor lighting POWER CONSUMPTION: 5VA Max. Resistive 28VDC 30A 30A
Security lighting
ENCLOSURE: Noryl Indoor/Outdoor

Parking lot lighting
NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA
Canopy lighting 3. All with lockable hasp (see page 153 for
enclosure dimensions).
2 CHANNEL
HVAC equipment
Interior lighting
Electric motors WIRING DIAGRAMS
Refrigerator defrost control:
CH 1 CH 1 CH 2 CH 2
condensers, heaters. SPDT SPDT SPDT SPDT
SPDT SPDT
DWZ100B
DWZ100B
SERIES SERIES DW200B
DW200B
SERIES SERIES
ORDERING INFO
TIMER SUPPLY
TIMER SUPPLY C NO CNC NO NC TIMER SUPPLYC
TIMER SUPPLY NO CNC NO
C NC
NO CNC NO NC
FEATURES CATALOG UPC TIMER SUPPLY NO. OF DRY CONTACTS
NO. CODE (VAC) 50/60Hz CHANNELS (UNPOWERED)
N 120 N
208-240
120277
208-240 277 N 120 N
208-240
120277
208-240 277
DWZ100B 82189 120/208-240/277VAC 1 SPDT L L
SCHEDULING: 99 ON & OFF set points 120V 120V 120V 120V
LOAD LOAD L L L L
allow individual programs for each day
DW200B 82190 120/208-240/277VAC 2 SPDT 208-240V208-240V N N 208-240V208-240V LOAD LOAD LOAD LOAD
of the week at a minimum 1 minute apart.
277V 277V N N N N
277V 277V
ASTRONOMIC (DWZ100B only): DW200B-0 82231 120/208-240/277VAC 2 SPDT
AC LINE INPUT
AC LINE INPUT AC LINE INPUT
AC LINE INPUT
Adjustable 10- 60 Northern or Southern SELECT PROPER
SELECTTERMINALS
PROPER TERMINALS SELECT PROPER
SELECTTERMINALS
PROPER TERMINALS
AND APPLYAND
ONLYAPPLY
ONEONLY ONE VOLTAGE
VOLTAGE AND APPLYAND
ONLYAPPLY
ONEONLY
VOLTAGE
ONE VOLTAGE
latitudes. Can be individually offset +/- 1 to 240
minutes from both sunset and sunrise times.
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment TWO SPEED
TWOPUMP
SPEEDWIRING
PUMP WIRING
(can be omitted).
LEAP YEAR: Automatic Compensation
scheduled ON or OFF, automatic operation then SPECIFICATION WRITERS GUIDE
resumes. DWZ100B 1. Furnish and install, where noted, a 1 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day
MANUAL OVERRIDE: Until the next
of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have
regularly scheduled ON or OFF, automatic
automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor.
operation then resumes.
11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure
CLOCK FORMAT: AM/PM or Military time. as standard. 13. Controller shall be capable of having astronomic with 1-240 minutes, plus or minus offset from sunrise or sunset. 14. To order specify TORK Model
DWZ100B.
POWER OUTAGE BACKUP: Permanent
DW200B 1. Furnish and install, where noted, a 2 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats.
schedule retention. Supercapacitor provides 7
3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day
days of real time backup.
of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have
automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor.
11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 69 USA 800.321.5847 www.nsiindustries.com TORK 70
DZM SERIES SPECIFICATIONS CONTACT RATINGS
MOMENTARY OUTPUT GREAT FOR LATCHING DZM200BP
365 / 7 DAY ADVANCED CONTACTORS TIMING ACCURACY: Line frequency.
TYPE
VOLTAGE RATING
LIGHTING CONTROL TIME INPUT VOLTAGE: 120/208-240/277VAC, General Purpose 120-277VAC 20A
SWITCH 50/60Hz.
Pilot Duty 120-277VAC 720VA
TERMINAL RANGE:
responsible
energy #14 - #16AWG for line input.
#12 - #16AWG load outputs.
APPLICATIONS CALIFORNIA Title 24

ASHRAE 90.1
OPERATING TEMPERATURE:
-40 to 158F (-40 to +70C).
Low voltage latching relays
Direct wire to mechanically POWER CONSUMPTION: 4VA Max.
held contactors ENCLOSURE: Noryl Indoor/Outdoor NEMA
3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All
with lockable hasp (see page 153 for dimensions).
FEATURES

SCHEDULING: 99 ON & OFF set points ORDERING INFO WIRING DIAGRAMS


allow individual programs for each day CATALOG UPC TIMER SUPPLY NO. OF DRY CONTACTS
of the week at a minimum 1 minute apart. NO. CODE (VAC) 50/60Hz CHANNELS (UNPOWERED) TIMER SUPPLY
AC LINE INPUT
ASTRONOMIC: Adjustable 10 - 60 Northern SPDT SELECT PROPER TERMINALS
DZM200BP 82188 120/208-240/277 2 AND APPLY ONLY ONE VOLTAGE
or Southern latitudes can be individually offset Momentary
N 120 208-240 277

+/- 1 to 240 minutes from both sunset and SPDT


DZM200BP-0 82232 120/208-240/277 2 120V
Momentary
sunrise times.
Memory Module 208-240V
USB-MMP 82196 Includes software
SEASONS: 1 to 4 with different daily Programmer
277V
schedules which can wrap around into the new
year.
CH 1 CH 2
HOLIDAYS: 1 to 24 individual dates.
DAYLIGHT SAVING: Automatic adjustment C ON OFF C ON OFF
(can be omitted). MECHANICALLY HELD CONTACTORS
OR LATCHING RELAYS
LEAP YEAR: Automatic Compensation.
MANUAL OVERRIDE: Until the next L L

regularly scheduled ON or OFF, automatic PULSE PULSE PULSE PULSE


operation then resumes. ON OFF ON OFF

N N
CLOCK FORMAT: AM/PM or Military time.
POWER OUTAGE BACKUP: Permanent
scheduled retention with memory module.
Supercapacitor provides 7 days of real time
backup. SPECIFICATION WRITERS GUIDE
MEMORY MODULE: Removable MM can be DZM 200BP only 1. Furnish and install, where noted, a 2 channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be capable
programmed at any one location and inserted of being programmed at any one location and inserted into DZM200BP (with memory module socket) in any other remote location. 3. Optional programmer shall be
into another DZM series unit. available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple
locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module
COPY FEATURE: Unit can be configured to programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in one minute resolution. 7. Display shall be of
copy program schedule to multiple memory LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall have 365 day holiday capabilities with 24 single
modules. dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard
OPTION: Memory Module Programmer with time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule Retention. 14. Controller shall have 7 day backup for real
software for computer connection programming. time with built in super capacitor. 15. Controller shall be capable of astronomic function, adjustable from 10 60 degrees Northern or Southern latitude. Each zone can
Also allows stand alone battery operation for additionally be offset 1 - 240 minutes for both sunset and sunrise. 16. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1
portable copy feature. button for each channel. 17. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 18. Controller shall be capable of 2 independent momentary outputs -
ON and OFF for each channel. 19. To order specify TORK Model DZM200BP.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 71 USA 800.321.5847 www.nsiindustries.com TORK 72
ELC SERIES SPECIFICATIONS CONTACT RATINGS
ENERGY AND LIGHTING CONTROL NEW! THE DO-IT-ALL ENERGY RATING
TYPE VOLTAGE
1 & 2 ZONE & LIGHTING CONTROLLER TIMING ACCURACY: Line frequency. NO NC
LIGHTING CONTROL INPUT VOLTAGE: General Purpose 120/277VAC 20 A 10 A
TIME SWITCH 120, 208-240, 277 50/60Hz (model specific).
120VAC 20A 10A
Ballast
responsible
TERMINAL RANGE: 208-277VAC 10A
energy
#10 - #16AWG for line/load. Tungsten 120-277VAC 5A
CALIFORNIA Title 24 #14 - #22AWG universal input.
APPLICATIONS Pilot Duty 120-240VAC 470VA 275VA
ASHRAE 90.1 OPERATING TEMPERATURE:
-20F to +140F (-29C to + 60C). 120VAC 1HP 14HP
Motor 12HP
HVAC equipment POWER CONSUMPTION: 6VA Maximum.
208-277VAC 2HP
Indoor/Outdoor lighting ORDERING INFO
Meets indoor/outdoor lighting CATALOG UPC TIMER SUPPLY NO. OF OUTPUT ENCLOSURE: Noryl clear cover Indoor/
energy code requirements NO. CODE (VAC) 50/60Hz CHANNELS CONTACTS Outdoor NEMA 3R with lockable hasp (see page
153 for enclosure dimensions).
ELC71PC/120 82517 120 1 DPDT

ELC71PC/208-240 82518 208-240 1 DPDT

ELC71PC/277 82519 277 1 DPDT WIRING DIAGRAMS

ELC72PC/120 82520 120 2 SPDT

ELC72PC/208-240 82521 208-240 2 SPDT

ELC72PC/277 82522 277 2 SPDT ELC72 ELC71


Accessory Photo
EPC-LC 82233 Sensor
Accessory
FEATURES LCS115M 82082 Momentary Switch SPST

SCHEDULING: 128 time based events allow HOLIDAYS: 26 holidays may be set using 10 MANUAL OVERRIDE: Keyboard button
individual programs for each day of the week at individual dates, 10 month type (last Monday control until the next regularly scheduled ON or
a minimum 1 minute apart. Event types include in May), or 6 specific holidays with one of 3 OFF, automatic operation then resumes.
ON, OFF, Duration, or Duty Cycle. independent holiday schedules.
STAGGERED START: Optional stagger up
SENSOR EVENT: 32 sensor driven events BLOCK HOLIDAY: 10 holiday blocks can be time between channels, after a power outage;
allow individual programs for each day of the set for individual days or for duration of any selectable from 5 seconds, 15 seconds, 30
week. number of days and may use one of 3 holiday seconds, 1 minute, 5 minutes, 10 minutes, and
schedules. 15 minutes.
ASTRONOMIC: Adjustable 10 - 70
Northern or Southern latitudes. Settings can be PULSE/TIME DURATION: 4 different ON CLOCK FORMAT: AM/PM or 24 hour format
offset from both sunset and sunrise times. settings from 1 second to 23 hours, 59 minutes,
POWER OUTAGE BACKUP: Capacitor
59 seconds.
UNIVERSAL INPUT: 2 inputs may be assigned provides minimum of 1 week of real time
to any channel. DUTY CYCLE: 4 different ON and OFF patterns backup for program and time of day.
SWITCHED INPUT: Accepts input from optional from 1 second to 23 hours, 59 minutes, 59
momentary or maintained switch. seconds.
PHOTOSENSOR INPUT: Accepts input from SPECIFICATION WRITERS GUIDE
DAYLIGHT SAVING: Automatic adjustment Installer shall furnish and install Tork ELC71 single-channel (or ELC72, two-channel) electronic time control. The control shall have 24 hour, 7 day, 365 day, or astronomic
optional sensor. EPC-LC (indoor/outdoor) has a
(can be omitted). capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments.
range from 0 to 200 foot-candles.
USER DEFINED INPUT: Accepts user supplied LEAP YEAR: Automatic Compensation. Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached.
4 20 milliamp sensor. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay)
REMOTE OVERRIDE: Universal input may capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Controller shall have 7 day backup for real time with built in
MOMENTARY CONTACT: May be configured be programmed for timed override from a supercapacitor. The digital time display shall be 34 in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Wiring terminals
for momentary ON/OFF operation to control momentary or maintained dry contact switch. shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in NEMA 3R enclosure with clear-view cover and shall be lockable to guard
latching contactors. The ELC71/72 operates as a against vandalism or tampering.
single-channel unit.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 73 USA 800.321.5847 www.nsiindustries.com TORK 74
ELC SERIES SPECIFICATIONS CONTACT RATINGS
ENERGY AND LIGHTING CONTROL NEW!
THE DO-IT-ALL ENERGY & RATING
TYPE VOLTAGE
4, 8 & 12 ZONE LIGHTING CONTROLLER TIMING ACCURACY: Line frequency.
NO NC
LIGHTING CONTROL INPUT VOLTAGE: General Purpose 120 - 277VAC 20A 10A
TIME SWITCH 24/120/208-240/277VAC, 50/60Hz.
120 VAC 20A 10A
TERMINAL RANGE: Ballast
208-277 VAC 10A 3A
responsible
energy #10 - #16AWG for line input.
Tungsten 120-277VAC 5A
#10 - #16AWG for load output.
APPLICATIONS CALIFORNIA Title 24
#14 - #22AWG universal input. Pilot Duty 120-240VAC 470VA 275VA
ASHRAE 90.1
OPERATING TEMPERATURE: 120VAC 1HP 14HP
Motor
HVAC equipment -20F to +140F (-29C to + 60C). 208-277VAC 2HP 12HP

Indoor/Outdoor lighting POWER CONSUMPTION: 10VA Maximum.


Meets indoor/outdoor lighting
energy code requirements ENCLOSURE: Metal Indoor NEMA 1 with
ORDERING INFO lockable hasp (see page 153 for dimensions).
CATALOG UPC TIMER SUPPLY NO. OF OUTPUT
NO. CODE (VAC) 50/60Hz CHANNELS CONTACTS

ELC74* 82523 24/120/208-240/277 4 SPDT


WIRING DIAGRAMS
ELC78 82524 24/120/208-240/277 8 SPDT

ELC712 82525 24/120/208-240/277 12 SPDT

EPC-LC 82233 Accessory Photo Sensor

LCS115M 82082 Accessory Momentary Switch SPST


FEATURES *Also CSA certified.

SCHEDULING: 128 time based events allow HOLIDAYS: 26 holidays may be set using 10 STAGGERED START: Optional stagger up
individual programs for each day of the week at individual dates, 10 month type (last Monday time between channels, after a power outage;
a minimum 1 minute apart. Event types include in May), or 6 specific holidays with one of 3 selectable from 5 seconds, 15 seconds, 30
ON, OFF, Duration, or Duty Cycle. independent holiday schedules. seconds, 1 minute, 5 minutes, 10 minutes, and
15 minutes.
SENSOR EVENT: 32 sensor driven events BLOCK HOLIDAY: 10 holiday blocks can be
allow individual programs for each day of the set for individual days or for duration of any CLOCK FORMAT: AM/PM or 24 hour format.
week. number of days and may use one of 3 holiday
POWER OUTAGE BACKUP: The program
schedules.
ASTRONOMIC: Adjustable 10 - 70 and time of day are maintained for a minimum
Northern or Southern latitudes. Settings can be PULSE/TIME DURATION: 4 different ON of 2 days by means of a capacitor. After two
offset from both sunset and sunrise times. settings from 1 second to 23 hours, 59 minutes, days, a lithium battery takes over and provides
59 seconds. a minimum accumulated time of 1 year. The
UNIVERSAL INPUT: 8 inputs may be assigned
lithium battery should provide over 10 years of
to any channel. ELC74 includes 4. DUTY CYCLE: 4 different ON and OFF patterns
protection.
SWITCHED INPUT: Accepts input from optional from 1 second to 23 hours, 59 minutes, 59
momentary or maintained switch. seconds. COMPUTER INTERFACE: Unit may be
PHOTOSENSOR INPUT: Accepts input from programmed with a PC.
DAYLIGHT SAVING: Automatic adjustment
optional sensor. EPC-LC (indoor/outdoor) has a
(can be omitted). SPECIFICATION WRITERS GUIDE
range from 0 - 200 foot-candels.
USER DEFINED INPUT: Accepts user supplied LEAP YEAR: Automatic Compensation. Installer shall furnish and install Tork ELC74 four channel (ELC78 eight channel or ELC712 twelve channel) electronic time control. The control shall have 24 hour, 7 day,
4 20 milliamp sensor. 365 day or astronomic capability with 128 events available. It shall also have 4 (8) user-definable durations and duty cycle lengths plus automatic daylight saving time
REMOTE OVERRIDE: Universal input may and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type). Control shall have keyboard override until overridden again
MOMENTARY CONTACT: May be configured be programmed for timed override from a or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have
for momentary ON/OFF operation to control momentary or maintained dry contact switch. momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Control shall provide 2 days of
latching contactors. The ELC74 operates as a power outage carry-over without a battery. Control shall provide 10 years of power outage protection with a battery. The digital time display shall be 34 in height. Clock
MANUAL OVERRIDE: Keyboard button
two channel unit. The ELC78 operates as a four format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal
control until the next regularly scheduled ON or
channel unit. The ELC712 operates as a six computer. Control shall be housed in a NEMA 1, lockable steel enclosure, to guard against vandalism or tampering.
OFF, automatic operation then resumes.
channel unit.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 75 USA 800.321.5847 www.nsiindustries.com TORK 76
LC200 SERIES SPECIFICATIONS CONTACT RATINGS
LIGHT LEVEL / TIME OF DAY OPTION STAGE LIGHTING RATING
2 ZONES LIGHTING CONTROL TURN ON LEVEL INPUT VOLTAGE:
TYPE VOLTAGE
NO NC
TIME SWITCH 120/240/277VAC, 50/60Hz. 120/240VAC 20A 10A
Resistive
TERMINAL RANGE: Relay #12AWG; input 277VAC 12A
120VAC 20A 10A
power terminals #14 - #22AWG; TOD/sensor Ballast

TOD2
TOD1
240/277VAC 6A 3A
terminals accept #18 - #22AWG.

C
Tungsten 120/240/277VAC 5A 3A

EPC1

TOD2
TOD1
responsible
energy OPERATING TEMPERATURE:
LIGHT LEVEL

EPC
C
APPLICATIONS
STAGE 1 STAGE 2

120/240VAC 470VA 275VA


5 6 5 6

-40F to +140F (-40C to + 60C).


4 7 4 7

Pilot Duty
3 8 3 8

ASHRAE 90.1 2 9 2 9

277VAC 690VA 1 10 1 10

24 hour convenience stores POWER CONSUMPTION: 5VA Maximum. SET RUN

Open wall parking structures ENCLOSURE: LC200 includes metal Indoor


EPC1 sensor
Large canopies supplied with unit. NEMA 1 with lockable hasp (see page 153 for POWER STAGE 1 STAGE 2

Building perimeters dimensions).


Atriums
OTHER MOUNTINGS:
LC200M mechanism only. For 120 VAC
Use to control two different Operation NEUT 120V240V 277V C NO NC C NO NC

outdoor lighting circuits utilizing WHITE


LINE INPUT OUTPUT 1 OUTPUT 2

one photocell. Sign lighting can WIRING DIAGRAMS


N
H
turn ON at one ambient light BLACK

level while parking lot lighting LOAD 1

turns ON at a different light LOAD 2

TOD2
TOD1
level.

C
For 240 VAC

EPC1

TOD2
TOD1
ORDERING INFO Operation
LIGHT LEVEL

EPC
C
STAGE 1 STAGE 2 NEUT 120V240V 277V C NO NC C NO NC
5 6 5 6

3
4 7
8 3
4 7
8
LINE INPUT OUTPUT 1 OUTPUT 2
RED
2 9 2 9

FEATURES H
1 10 1 10

CATALOG UPC INPUT SUPPLY NO. OF OUTPUT SET RUN


H
NO. CODE (VAC) 50/60Hz ZONES CONTACTS BLACK

LOAD 1
PHOTOSENSOR INPUT: EPC1 included. LC200 82111 120/240/277VAC 2 SPDT
POWER STAGE 1 STAGE 2

LOAD 2
DUAL OUTPUTS: with independent turn-ON LC200M 82113 120/240/277VAC 2 SPDT
adjustment for Stage1 and Stage 2. For 277 VAC
For 120 VAC Operation
LIGHT LEVEL ACTIVATION: Turn ON is user Operation NEUT 120V240V 277V C NO NC C NO NC
NEUT 120V240V 277V

LINE INPUT
C NO NC

OUTPUT 1 OUTPUT 2
C NO NC

settable from 2 to 100 footcandle; Independent LINE INPUT OUTPUT 1 OUTPUT 2


N
WHITE
WHITE
light level adjustment for each zone. Turn OFF N H
H ORANGE
is a maximum of 2 times turn ON level. Built-in BLACK

LOAD 1
delay ON of 30 seconds to avoid reaction to LOAD 1
lightning or headlights. LOAD 2
LOAD 2

SWITCHED INPUT: Can be used with a time


switch for photocell ON of two different lighting For 240 VAC
Operation
circuits at different ambient light levels, then NEUT 120V240V 277V

LINE INPUT
C NO NC

OUTPUT 1 OUTPUT 2
C NO NC

time-of-day OFF. H
RED

H
BLACK

LOAD 1

SPECIFICATION WRITERS LOAD GUIDE


2
Furnish and install an electronic light sensor and control with dual outputs for two lighting zones. Each output shall be capable of a different user settable turn
ON light level set For
points277
fromVAC
2 to 100 footcandles. Turn ON to turn OFF ratio shall be 1:2. Controller shall also offer two digital inputs, which can accept a contact
Operation
closure from an independent time switch or EMS system,
NEUT 120V240V 277V

LINE INPUT
thereby allowing for independent time of day control.
C

OUTPUT 1 OUTPUT 2
NO NC C NO NC

WHITE
N
H
ORANGE

LOAD 1

LOAD 2

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 77 USA 800.321.5847 www.nsiindustries.com TORK 78
DGU & SPECIFICATIONS CONTACT RATINGS
CODE SOLUTION FOR
DGLC SERIES NEW!
SMALL PROJECTS TIMING ACCURACY: Line frequency. TYPE VOLTAGE
RATING

LIGHTING CONTROL WITH PHOTO NO NC


INPUT VOLTAGE: 120-277VAC, 50/60Hz
OR OVERRIDE INPUT, 7 DAY (auto detection).
Resistive 24-277VAC 20A 10A
7 DAY LIGHTING 120VAC
DGU100A
TERMINAL RANGE: Ballast 20A 10A
CONTROL TIME SWITCH 277VAC
responsible
energy
#12 - #18AWG for line/load.
CALIFORNIA Title 24 Tungsten 120VAC 15A
#18 - #26AWG sensor/switch input.
APPLICATIONS ASHRAE 90.1
Pilot Duty
120VAC
720VA
290VA
OPERATING TEMPERATURE: 240VAC 360VA
-31F to +131F (-35C to + 55C). 120VAC 1HP 14HP
INTERIOR LIGHTING Model EPC-A supplied
ORDERING INFO Motor 12HP
with DGLC-A unit. POWER CONSUMPTION: 6VA Maximum. 240VAC 2HP
Open office zoning
Hallways CATALOG UPC INPUT SUPPLY NO. OF OUTPUT Resistive 28VDC 20A 10A
NO. CODE (VAC) 50/60 Hz CHANNELS CONTACTS
ENCLOSURE: Noryl Indoor/Outdoor NEMA
Meeting and sales areas 3R . Suffix -NC Noryl Indoor/Outdoor NEMA DGUM100A
With optional DGU100A
Stock rooms and warehouses Timed Override DGU100A-Y 82211 120-277VAC 1 DPDT 3R with clear Lexan cover. Suffix -Y metal
Indoor enclosure NEMA 1. All with lockable
SPDT
EXTERIOR LIGHTING DGUM100A 82212 120-277VAC 1 Momentary hasp (see page 153 for dimensions).
Signage and store windows SPDT
DGUM100A-Y 82224 120-277VAC 1
Security Momentary
Parking lots DGLC100A-NC 82223 120-277VAC 1 DPDT
WIRING DIAGRAMS
DGLC200A-NC 82213 120-277VAC 2 SPDT
DGLC100A
Accessory Photo DGUM100A
EPC-A 82112 DGU100A
Sensor
SSA200R-24 14015 24VAC/24VDC SPDT
FEATURES Transformer
TRP-U 82030 120/277VAC SPST
Power Pack
SCHEDULING: 56 ON & OFF set points MANUAL OVERRIDE: Until the next
provide individual programs for each day regularly scheduled ON or OFF, automatic
of the week. Minimum setting is 1 minute. operation then resumes.
PHOTOSENSOR INPUT: Unique push MOMENTARY CONTACT - DGUM100A: DGLC100A DGLC200A
DGUM100A
button set-up assures accurate operation 2 second contact closure ON & OFF to control
with automatic calibration that adjusts for mechanically held contactors or latching relays.
wire size and distance. EPC-A photo sensor is
BLOCK HOLIDAY: 9 holiday blocks can be
included with the DGLC-A and may be ordered
set for individual days or for duration of any
as an option for use with model DGU100A &
number of days.
DGUM100A.
DAYLIGHT SAVING: Automatic adjustment
LIGHT LEVEL ACTIVATION: Turn ON is user
(can be omitted).
settable from 1 to 100 footcandle; Turn OFF
is a maximum of 2 times turn ON level. Each LEAP YEAR: Automatic Compensation.
DGLC100A DGLC200A
channel has an independent setting. Includes a
CLOCK FORMAT: AM/PM or 24 Hour
user settable delay before ON or OFF between
format.
1 90 seconds. SPECIFICATION WRITERS GUIDE
POWER OUTAGE BACKUP: Permanent DGU and DGLC SERIES - 1. Furnish and install, where noted, a 1 (2) channel 7 day programmable digital time switch. 2. Controller shall program in AM/PM (12
REMOTE OVERRIDE ON: Each channel has
schedule retention. Supercapacitor provides 7 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate
independent input for a maintained dry-contact
days of real time backup. scheduling for each day of the week with one minute resolution. 5. Controller shall have photo sensor input user adjustable per circuit between 1 and 100 footcandle
closure. May use TORK model SSA200R-24
and TRP-U for timed override. May use with turn ON level. 6. Each channel shall have and switched input to override circuit ON. 7. Controller shall have 365 day holiday capabilities with 9 block holidays
occupancy sensor as override. for individual or duration of any number of days. 8. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 9.
Controller shall have automatic Leap Year correction. 10. Controller shall have Permanent Schedule Retention. 11. Controller shall have 7 days backup for real time
with built in super capacitor; no batteries to maintain. 12. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button
for each channel. 13. Unit shall have NEMA type 3R indoor/outdoor enclosure standard. 14. To order specify TORK Model DGU100A. (Alt 14. To order 1 channel
momentary contact closure for latching contactor control specify DGUM100A). (Alt 14. To order controller with EPC-A photo sensor included in package specify TORK
Model DGLC100A-NC (DGLC200A) with clear cover.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 79 USA 800.321.5847 www.nsiindustries.com TORK 80
DLC400BP FLEXIBLE INDOOR/ SPECIFICATIONS CONTACT RATINGS
4 ZONE LIGHTING CONTROL
OUTDOOR LIGHTING TYPE VOLTAGE
RATING
TIME SWITCH TIMING ACCURACY: Line frequency.
CONTROLLER NO NC
INPUT VOLTAGE: General Purpose 24-277VAC, 30VDC 30A 30A
120/208 - 240/277VAC, 50/60Hz.
Ballast 120-277VAC 20A 10A
TERMINAL RANGE: #10 - #14AWG.
responsible OPERATING TEMPERATURE: Tungsten 120VAC 10A
energy
APPLICATIONS -40F to +158F (-40C to + 55C).
CALIFORNIA Title 24 Pilot Duty 120-277VAC 720VA 720VA
POWER CONSUMPTION: 30VA Maximum.
ASHRAE 90.1
INTERIOR LIGHTING ENCLOSURE: Metal Indoor/Outdoor NEMA 3 with
Open office zoning Model EPC2
lockable hasp (see page 153 for dimensions).
supplied with unit.
Hallways
Meeting and sales areas Memory Module
Stock rooms and warehouses
With optional WIRING DIAGRAMS
Programmer optional Timed Override

EXTERIOR LIGHTING
Signage and store windows
Security ORDERING INFO
Parking lots
CATALOG UPC INPUT SUPPLY (VAC) NO. OF OUTPUT
NO. CODE 50/60 Hz CHANNELS CONTACTS

DLC400BP 82191 120/208-240/277 4 SPDT


Memory Module
USB-MMP 82196 Includes Software
Programmer
FEATURES SSA200R-24 14015 24VAC/24VDC SPDT

CONFIGURABLE ZONES: Simple three MANUAL OVERRIDE: Until the next


position slide switch sets logic for each zone: regularly scheduled ON or OFF, automatic
Time ON/Time OFF, Photo ON/Photo OFF, or operation then resumes.
Photo ON/ Time OFF.
SEASONS: 1 to 4 with different daily schedules
SCHEDULING: 99 ON & OFF set points allow which can wrap around into the new year.
individual programs for each day of the week.
HOLIDAYS: 1 to 24 individual dates.
Minimum 1 minute apart.
DAYLIGHT SAVING: Automatic adjustment
ASTRONOMIC: 1. Adjustable 10 - 60
(can be omitted).
Northern or Southern latitudes. 2. Can be
individually offset +/-1-240 minutes from both LEAP YEAR: Automatic Compensation.
sunset and sunrise times.
POWER OUTAGE BACKUP: Permanent
PHOTOSENSOR INPUT: EPC2 photo sensor schedule retention with memory module.
included. Battery provides real time backup for 6 months
cumulative.
LIGHT LEVEL ACTIVATION: Turn ON
and OFF level is user settable from 1 to 100 MEMORY MODULE: Removable MM can be SPECIFICATION WRITERS GUIDE
DLC400BP 1. Furnish and install, where noted, a 4 zone lighting controller with photosensor input (TORK model EPC2 photosensor to be supplied with controller). 2. Memory Module shall be capable of being
footcandle. Each channel has an independent programmed at any one location and inserted
programmed at any one location and inserted into DLC400BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows
setting. into another DZS series unit. based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Each zone shall be capable of independent, user settable turn ON and turn OFF light level set
points ranging from 1 to 100 footcandles. 5. Three position slide switches shall be provided for each of the 4 zones allowing for user settings based on a) time of day or b) combination time of day and light level or
REMOTE OVERRIDE: Maintained dry contact OPTION: Memory Module Programmer with
c) light level. 6. Controller shall provide 30 Amp General Purpose isolated contacts (unpowered) for each zone as well as a 500 ma, 24VDC output. 7. Controller shall have 1 digital input per channel for: a) remote
closure or use TORK Model SSA200R-24 for software for computer connection programming. contact closure which can be used to turn corresponding outputs ON/OFF outside of the normal control time or b) remote timed override which can be accomplished for the corresponding outputs with the use of TORK
timed override with flash warning before OFF. Also allows stand alone battery operation for model SSA200R-24. 8. Enclosure shall provide separate wiring compartments for power connections and auxiliary connections. 9. Controller shall be capable of local override ON or OFF to the next scheduled event
May use with occupancy sensor as override. portable copy feature. using the keypad for each zone. 10. Each zone shall be capable of astronomic function, adjustable from 10 60 degrees Northern or Southern latitude. Each zone can additionally be offset +/- 1299 minutes for
both sunset and sunrise. 11. Controller shall provide automatic daylight saving time (which can be omitted). Leap year adjustment shall be compensated for automatically. 12. Controller shall have 365 day holiday
capability with 24 single dates and 4 seasons of unlimited duration. 13. Controller shall be capable of 99 set points with separate scheduling for each day of the week. 14. Controller shall have back-up capability: a)
Schedule shall be retained for 40 years without power, b) real time shall be retained for 6 months using a field replaceable 9V lithium battery. 15. Unit shall have a NEMA type 3, metal indoor/outdoor enclosure.

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 81 USA 800.321.5847 www.nsiindustries.com TORK 82
LD SERIES SPECIFICATIONS CONTACT RATINGS
EXTENDED LIGHTING CONTROL ADD A WARNING BLINK RATING
LIGHTING DELAY TO ANY CONTROL INPUT VOLTAGE: TYPE VOLTAGE
NO NC
120/208/240/277VAC, 50/60Hz.
TIME SWITCH General 24/240VAC 20A 10A
TERMINAL RANGE: #10 - #16AWG. Purpose 277VAC 20A 3A
120VAC 20A 10A
OPERATING TEMPERATURE: Ballast 208-277VAC 10A 3A
-22 to 150F (-30 to +65C).
ASHRAE 90.1 Tungsten 120-277VAC 5A 3A
POWER CONSUMPTION: 5VA Maximum.
APPLICATIONS 120-240VAC 470VA 275VA

Pilot Duty 27VAC 690VA


ENCLOSURE: Metal Indoor NEMA 1 with

Resistive 28VDC 20A 10A


Open offices lockable hasp (see page 153 for dimensions).


Gymnasiums
Warehouses
Outdoor recreation courts WIRING DIAGRAMS
User-activated lights LDS WIRING LDSH WIRING
with time limits TORK TIME SWITCH
TORK TIME SWITCH
OUTPUT TERMINALS

Match with photocontrol and


OUTPUT TERMINALS
OFF
OFF NO C NC
NO C NC

timer to limit hours of use


MOMENTARY
PUSH-BUTTON H
MOMENTARY H SWITCH
PUSH-BUTTON SWITCH 120 VAC
N
N
ON
ON

208 277
208 277 REMOTE H N N 120 240 VAC
REMOTE H N N 120 240 VAC INPUT
INPUT
C ON OFF
C ON OFF TIME SWITCH INPUT POWER
TIME SWITCH INPUT POWER DO NOT APPLY INPUT
DO NOT APPLY INPUT VOLTAGE
VOLTAGE
AUX. OUTPUT MAIN LOAD OUTPUT
MAIN LOAD OUTPUT
TERMINALS TERMINALS
TERMINALS

NC NO C NC NO C
NC NO C

H H

H
AUX N LOAD N

ORDERING INFO
LOAD
LOAD N

FEATURES
CATALOG UPC INPUT SUPPLY (VAC) OUTPUT ENCLOSURE TORK TIME SWITCH
TORK TIME SWITCH
OUTPUT TERMINALS

NO. CODE 50/60 Hz CONTACTS TYPE OUTPUT TERMINALS


OFF

MAINTAINED INPUT WITH LOAD WARNING BLINK: OFF


NO C NC
MOMENTARY
NO C NC

LDS Series controls output load contacts based on power applied Metal Indoor MOMENTARY
PUSH-BUTTON H

LDS-A 81026 120/208-240/277 SPDT


H SWITCH 120 VAC
PUSH-BUTTON SWITCH

NEMA 1 N

to the time switch input contact. At removal of power from


N
ON
ON

the time switch input, LDS Series provides 1 second blink then
208 277

LDS 81025 120/208-240/277 SPDT Mechanism REMOTE


INPUT
H N N 120
208
240
277
VAC
REMOTE
INPUT
H N N 120 240 VAC

keeps load contacts closed for an extra 1 or 5 minutes (user


C ON OFF
C ON OFF TIME SWITCH INPUT POWER
TIME SWITCH INPUT POWER DO NOT APPLY INPUT
DO NOT APPLY

Metal Indoor
INPUT VOLTAGE

selectable) before turn off.


VOLTAGE

LDSH-A 81031 120/208-240/277 SPDT AUX. OUTPUT MAIN LOAD OUTPUT

NEMA 1 MAIN LOAD OUTPUT


TERMINALS
TERMINALS TERMINALS

NC NO C NC NO C

MAINTAINED INPUT WITH AUXILARY WARNING: LDSH 81028 120/208-240/277 SPDT Mechanism
NC NO C

LDSH Series controls output load contacts based on power H H

applied to the time switch input contact. At removal of power


H
AUX ON
N MECHANICALLY HELD
LOAD

from the time switch input, LDSH Series closes a second set of
ON OFF CONTACTOR WITH
MECHANICALLY HELD COIL CLEARING
OFF CONTACTOR WITH COMMON CONTACTS
COIL CLEARING PHOTOCONTROL
contacts for a user supplied audible or visual warning device.
COMMON CONTACTS
N

The warning circuit closes for a selected time of 4 seconds (best TORK TIME SWITCH
OUTPUT TERMINALS

for audible device or continuous, then keeps load contacts closed APPLICATION WIRING NO C NC

for an extra 1 or 5 minutes (user selectable) before turn OFF. APPLICATIONEXAMPLE


Lighting for a high schools tennis courts FLASHING LIGHT

MOMENTARY INPUT: Provides timed override when time turns on during normal class hours
when natural light diminishes using a
switch input contact is unpowered (timer OFF). When activated 7 day time switch and photocell. After
H

N
120V

during the warning period, load contacts are kept closed and 3pm, staff members sometimes use the
timing starts. Both series can accept momentary input contact courts (the time switch is then off). A C ON OFF H N N 120 208/240277

momentary pushbutton activates the REMOTE INPUT TIME SWITCH INPUT INPUT POWER

closure for ON to start the timing and OFF to end the timing. LDSH for timed override of HID lighting. AUXILLARY MAIN LOAD
N

OUTPUT LDSH OUTPUT

Five minutes before the lights go out, an NC NO C NC NO C

TIMED OVERRIDE SETTINGS: User may select override


MOMENTARY
PUSHBUTTON

auxiliary contact flashes an incandescent SWITCH


120V

times of 12, 1, 112, 2, 6, 9, or 12 hours. Warning before OFF is warning beacon (HIDlighting can not OFF
N

always active after override time. be made to blink). Additional timed ON


120V
H

MECHANICALLY-HELD

override can be arranged for via the N


OFF ON N
4 POLE LIGHTING
CONTACTOR

momentary pushbutton. SWITCHED CIRCUIT SWITCHED CIRCUIT


TO TENNIS COURT TO TENNIS COURT LIGHTS
LIGHTS

480V CIRCUITS FROM PANEL

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 83 USA 800.321.5847 www.nsiindustries.com TORK 84
DGS SERIES SPECIFICATIONS CONTACT RATINGS
SIGNALING AND DUTY CYCLE NEW!
31 DAY CYCLE TIME: RATING
TYPE VOLTAGE
24 HOUR OR 7 DAY AN INDUSTRY FIRST! TIMING ACCURACY: Line frequency. NO NC
TIME SWITCH INPUT VOLTAGE: Resistive 24-277VAC 20A 10A
120 - 277 VAC, 50/60 Hz (auto detection).
120VAC
Ballast 20A 10A
TERMINAL RANGE: #12 - #18AWG. 277VAC
Tungsten 120 VAC 15 A
OPERATING TEMPERATURE:
-31F to +131F (-35C to + 55C). 120 VAC 290VA
APPLICATIONS Pilot Duty 240VAC 720VA 360VA
14HP
POWER CONSUMPTION: 6VA Maximum. Motor 120VAC 1HP
240VAC 2HP 12HP
DGS100A
Signaling ENCLOSURE: Noryl Indoor/Outdoor NEMA

Resistive 28VDC 20A FOR 120V/277VAC
10A
Duty cycle 3R with lockable hasp (see page 153 for
enclosure dimensions).

WIRING DIAGRAMS
DGS100A
FOR 208-240VAC
DGS100A DG180A
FOR 120V/277VAC FOR 120V/277VAC

FEATURES ORDERING INFO


CATALOG UPC INPUT SUPPLY (VAC) NO. OF OUTPUT
DG180A & DG280A: 56 ON & OFF set points provide NO. CODE 50/60 Hz CHANNELS CONTACTS
individual daily programs. Minimum setting is 1 minute. 24 HOUR MODELS
DG180A 82206 120-277VAC 1 DPDT DG180A DG280A
DGS100A: 56 ON & OFF set points provide individual programs DGS100A FOR 208-240VAC
for each day of the week. Minimum setting is 1 minute. FOR 208-240VAC
DG280A 82207 120-277VAC 2 SPDT
DUTY CYCLE: Two different ON/OFF patterns or signal
durations may be programmed. The durations can be up to 23 DG280A-24 82220 24VAC 2 SPDT
hours, 59 minutes and 59 seconds in length.
7 DAY MODELS
SKIP FUNCTION (24 HOUR UNITS ONLY): Each channel DGS100A 82205 120-277VAC 1 DPDT
can be set for ACTIVE/SKIP operations that alternate from 1 - 31
days. This becomes an effective way to cycle loads on varying DGS100A-12 82218 12VDC 1 DPDT
days within the month. Using the two-circuit DG280A, two loads
can be set to operate on alternate days in a simple manner. DGS100A-24 82219 24VAC 1 DPDT
DAYLIGHT SAVING: Automatic adjustment (can be omitted). DG280A

LEAP YEAR: Automatic Compensation.


MANUAL OVERRIDE: Until the next regularly scheduled ON SPECIFICATION WRITERS GUIDE
or OFF, automatic operation then resumes. DGS100A SERIES 1. Furnish and install, where noted, a 1 channel 7 day programmable digital time switch. (Alt 1 DG180 Series 1. Furnish and install, where noted,
CLOCK FORMAT: AM/PM or 24 hour. a 1 (2) channel 24 hour programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of
switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5.
POWER OUTAGE BACKUP: Permanent schedule retention. unit shall be capable of two duty cycle or signal durations from 1 second to 23 hours, 59 minutes and 59 seconds. 6. Controller shall be able to select USA Standard
Supercapacitor provides 7 days of real time backup. Daylight Saving, Standard time or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention.
9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON and OFF
to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model
DGS100A (Alt 12. Controller shall have a 31 day cycle to alternate days that programs are active or to be omitted. 13. To order specify TORK Model DG180A [DG280A]).

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 85 USA 800.321.5847 www.nsiindustries.com TORK 86
EJWT & E500T SPECIFICATIONS CONTACT RATINGS
NEW!
SERIES PERFECT FOR
TIMING ACCURACY: 1% of timing range. TYPE VOLTAGE
RATING

DELAY, INTERVAL & PROCESS CONTROL NO NC


INPUT VOLTAGE: 120/240VAC, 60Hz.
PERCENTAGE TIME CYCLE General Purpose 120-240VAC 20A 10A
TIME SWITCHES TERMINAL RANGE: #12 - #18AWG.
Resistive 120-240VAC 20A 10A
OPERATING TEMPERATURE: 120VAC 1HP 14HP
32F to +122F (0C to + 50C). Motor 12HP
208-240VAC 2HP
APPLICATIONS EJWT POWER CONSUMPTION: 16VA Maximum. Pilot Duty 120/240VAC 470VA 275VA

Poultry and livestock ENCLOSURE: Indoor NEMA 4X is standard (see


page 153 for enclosure dimensions).
Agriculture or greenhouse
Oil well pumping
Ventilation
Process control
E502T

E501T EJWT

ORDERING INFO
CATALOG UPC INPUT SUPPLY (VAC) OUTPUT
FEATURES NO. CODE 60 Hz CONTACT

EJWT PERCENTAGE TIMER EJWT 82513 120-240VAC SPDT


960 time combinations with two dials.
Cycle Time Dial sets 32 repeating cycles from E500T 82514 120-240VAC SPDT
15 seconds to 24 hours. WIRING DIAGRAMS
E501T 82515 120-240VAC SPDT
Percentage ON Dial has 32 steps from 0%
to 100%.
E502T 82516 120-240VAC SPDT
Repeats cycle as long as power is applied.
E500T ON DELAY TIMER
Dial sets 32 time delay durations from EJWT
E500T / E501T / E502T
5 seconds to 3 hours.
External switch activated starts delay to ON.
Runs until external switch turns OFF.
E501T AUTO OFF INTERVAL TIMER
Dial sets 32 time durations from 10 seconds
to 12 hours.
Start/Stop button or External switch starts
interval ON.
Automatically turns OFF at end of preset time.
START/STOP or External switch turns OFF.
E502T OFF DELAY TIME
Dial sets 32 time durations from 5 seconds
to 3 hours.
External switch starts interval ON.
Automatically turns OFF at end of preset time.
External switch turns OFF. E500T / E501T / E502T

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 87 USA 800.321.5847 www.nsiindustries.com TORK 88
DIN SERIES CALIFORNIA Title 24
SPECIFICATIONS CONTACT RATINGS
1 OR 2 CHANNEL NEW! PANEL BUILDERS RATING
ASHRAE 90.1 TYPE VOLTAGE
7 DAY TIME SWITCH CHOICE INPUT VOLTAGE: 120VAC, 50/60Hz. NO NC
TERMINAL RANGE: #12 - #18AWG. Resistive 120VAC 16A 16A
OPERATING TEMPERATURE:
General Purpose 120VAC 8A 8A
DIN100B: 14- 131F (-10- +55C).
Motor
DIN200B: 14- 113F (-10- +45C). 120VAC 12HP
(DIN100 only)
CALIFORNIA Title 24
APPLICATIONS POWER CONSUMPTION: 4VA Maximum.
DIN100B ASHRAE 90.1
MOUNTING: DIN rail #50022 (35mm) or
Panel builders flat surface using supplied adapter.
Indoor/Outdoor lighting
DIN200B
Security systems
HVAC equipment

WIRING DIAGRAMS

DIN200B
DIN100B DIN100B DIN200B

ORDERING INFO
35.80
Channel B (C2)
CATALOG UPC DRY CLOCK INPUT NO. OF NUMBER OF 55.00
FEATURES NO. CODE CONTACTS 50/60 Hz CHANNELS ON/OFF
Output
52.5 60

SCHEDULING: 8 ON and OFF pairs of set DIN100B 82193 SPDT 120VAC 1 8


14
points for DIN100B. 4 ON and OFF (CH A) and Channel B (C2)
4 Channel A
3 ON and OFF (CH B) pairs of set points for DIN200B 82192 SPDT 120VAC 2
3 Channel B Channel B (C2)
DIN200B. Individual programs on each day of NC NO

85.00
8 7 6
the week. Minimum setting is 1 minute.

45.00
8 7 6

85
35.2
MANUAL OVERRIDE: Until the next regular 1 2 3 4 5

1 2 3
scheduled ON or OFF, automatic operation then 4 5
Channel A (C1)
resumes. DIN200B
NO NC

CLOCK FORMAT: AM/PM. DIN100B 46.00 Channel A (C1)


60.00
POWER OUTAGE BACKUP: Battery retains Channel A (C1) Input
time and schedule. Channel B (C2) Output
35.80 55.00 Output
52.5 60

14 D
Channel B (C2)
Channel B (C2)
NC NO
8 7 6

85.00
8 7 6
45.00

85
35.2
1 2 3 4 5

1 2 3 4 5
Channel A (C1)
NO NC

Channel A (C1)
46.00
60.00 Channel A (C1) Input
Output

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 89 USA 800.321.5847 www.nsiindustries.com TORK 90
SMC SERIES SPECIFICATIONS 5401 SERIES
MOMENTARY INCREASED AMPERAGE
CONTACT ADAPTER INPUT VOLTAGE: 120VAC, 50/60Hz. & VOLTAGE SWITCHING
TERMINAL RANGE: #12 - #18AWG. 40 AMP CONTACTORS
OPERATING TEMPERATURE:
-31F to +131F (-35C to + 55C).
POWER CONSUMPTION: 6VA max.
APPLICATIONS ENCLOSURE: Noryl Indoor/Outdoor APPLICATIONS
NEMA 3R with lockable hasp (see page
5401 CONTACT RATINGS
153 for dimensions).
Converts maintained contacts for Lighting loads
TYPE VOLTAGE RATING
pulse switching Exhaust fans 5441
Timer to latching contactor control Electric and hot water heaters Resistive 120-600VAC 50A
Photocell to latching contactor control Refrigeration and defrosting
Signaling FLA 120-600VAC 40A
120VAC 3HP
240VAC 7.5HP
Motor
480VAC 20HP
ORDERING INFO 600VAC 25HP
Coil Data: 120VAC @ 60Hz
CATALOG UPC INPUT SUPPLY OUTPUT
NO. CODE (VAC) 50/60Hz CONTACTS 6VA Holding/seal; 60VA inrush

SPDT
SMC3D 52011 120 Momentary

CONTACT RATINGS WIRING DIAGRAMS


FEATURES FEATURES
RATING
TYPE VOLTAGE
NO NC 5401 5
MAINTAINED INPUT: SMC3D accepts CONTACT RATINGS: Can switch up to 40 {
{
120VAC
208VAC
maintained input power from any 120 volt Resistive 120VAC 10A 10A AMPS per pole from 120VAC to 600VAC, one 277VAC
120VAC
208VAC
control. When power is applied or removed a to three circuits simultaneously. BLACK 480VAC 277VAC
480VAC
short contact closure (pulse) is created on the General Purpose 120VAC 10A 10A WHITE
EASY WIRING: Includes 120 volt control N
dry output contacts. Motor 120VAC 14HP Control circuit
wiring compartment. 5441 has terminal strip from Time Switch
MOMENTARY OUTPUT: SMC3D provides pre-mounted for quick connection. 120VAC
Wire
SMC 3D
two dry output contacts. The ON contact B, C
WIRING
Input Sustained voltage 120VAC DIAGRAMS
120VAC, 240VAC ENCLOSURE: 5401 - Metal NEMA 3 the sa
provides a 2 second contact closure (pulse) Momentary Contacts (unpowered) 277VAC, 30VDC
30 Amps inrush enclosure. 5441 - Metal NEMA 1 Indoor
when power is applied to the input contacts.

{
enclosure (see page 153 for enclosure 120VAC
The OFF contact provides a 2 second pulse TORK DIGITAL CONTROL
208VAC
TERMINAL BLOCK
dimensions). 277VAC
when power is removed from the input
MAINTAINED CONTACT INPUT
480VAC Control circu

contacts. 24VAC
NO C NC
5401 ORDERING
5440INFO 5441 Wire other c
H
120VAC 120 to 480VAC 120 to 480VAC
N {
{ {
INPUT
120
120VAC
208VAC
CATALOG UPC
120VAC
COIL NO. AOF OUTPUT { 120VAC 120VAC A { 120VAC
SMC 3D VAC
277VAC NO. CODE
208VAC VOLTS CONTACTORS CONTACTS 208VAC 208VAC 208VAC
ON RELAY OFF RELAY
BLACK 480VAC 277VAC 277VAC 277VAC 277VAC
NC NO C NC NO C 480VAC 480VAC 480VAC 480VAC
WHITE 5401 81021 120 1 3PST
PUSH ON N N N
LOW VOLTAGE ON PULSE
Control circuit B B
LATCHING RELAY
OR MECHANICALLY
from Time Switch 5441 81022 120 4 3PST
HELD CONTACTOR OFF PULSE PUSH OFF
120VAC C C
NEUTRAL Wire contactors Wire contactors
B, C and D B, C and D
the same as A. D the same as A. D
N H
TORK DIGITAL CONTROL
{
REALAY CONTACTOR
TERMINAL BLOCK A B C D A B C D
MAINTAINED CONTACT INPUT
120VAC
L L L 208VAC
277VAC
480VAC Keep low voltage wires Keep low voltage wires
Control circuit from Time Switch Control circuit from Time Switch
NO C NC
inside this compartment. inside this compartment.
AUX 24VAC 120VAC
H Wire other circuits B, C and D respectively Wire other circuits B, C and D respectively
CONTACT
120VAC
N
LOAD LOAD LOAD 120
SMC 3D VAC

DIGITAL
ON RELAY OFF RELAY
NC NO C NC NO C

CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC PUSH
ON
TORK 91 USA 800.321.5847 www.nsiindustries.com TORK 92
HPS STARTER SPECIFICATIONS TRP SERIES SPECIFICATIONS
FOR HIGH PRESSURE SODIUM LAMPS LOW VOLTAGE SWITCHING
CONTACTS: SPST contacts.
STARTING AID LINE VOLTAGE: 105 - 347VAC. TRANSFORMER RELAY
POWER PACKS CONTACT RATING:
LAMP VOLTAGE: 55 or 100VAC. 20 Amps Ballast @ 120 or 277VAC.
LAMP WATTAGE: 35 to 400 watts. 15 Amps Tungsten @ 120VAC.
1.0 Horsepower @ 120VAC.
OPERATING TEMPERATURE:
-40F to +221F (-40C to + 105C). TEMPERATURE RANGE:
APPLICATIONS APPLICATIONS 0 to 150F (18 to 66C).
LEAD LENGTH: 9 inches. Pre-wired in metal enclosure.
WEIGHT: 7 oz.
Designed to operate as a starting aid, for all ENCLOSURE: Durable, high temperature
Low voltage switching of line voltage
Lexan housing. ENCLOSURE: Metal NEMA 1 Indoor
H.P.S. ballasts from 35 to 400 watts, with lamp lighting circuits up to 20 Amp ballasts or enclosure (see page 153 for enclosure
voltage of 55 or 100 volts. 15 amp tungsten loads. Also up to 1.0 HP dimensions).
motors for ventilating and exhaust fans.
Low voltage switching by digital or
mechanical controls for higher amperage ORDERING INFO
loads including those of two different
CATALOG UPC INPUT
voltages. NO. CODE
DESCRIPTION
VOLTAGE
Single Transformer
TRP-1** 82032 120VAC
Relay Powerpack
Single Transformer
TRP-2** 82033 277VAC
Relay Powerpack
Four Transformer
TRP400* 82132 120VAC
Relay Powerpack
Four Transformer
TRP402* 82133 277VAC
ORDERING INFO Relay Powerpack
Eight Transformer
TRP800* 82135 120VAC
FEATURES CATALOG UPC Relay Powerpack
DESCRIPTION
NO. CODE Eight Transformer
TRP802* 82136 277VAC
Relay Powerpack
SMART VOLTAGE: Delivers appropriate HPS30 81030 High Pressure Sodium Starter *Not for use with occupancy sensors.
trigger spikes for lamp ignition, then reduces **For replacement parts only. For newer style Transformer Relay Power Pack, see
voltage to good lamps. Continues to feed TRP-U on page 116.
voltage spikes to old or poorly working
lamps.
HIGH GRADE MATERIAL: All components WIRING DIAGRAMS
are sealed with high grade die-electric
material to protect against contaminants and
SURGE SUPPRESSOR
other adverse environmental conditions. FOR HIGH ELECTRICAL NOISE
BALLAST
EASY INSTALLATION: Universal 3 wire BLACK
CENTER
design, color coded for ease of installation. CONTACT
RED H.P.S.
TAP STARTER
LAMP
WHITE
SHELL APPLICATIONS

LINE COMMON
For high electrical noise ORDERING INFO
interference, recommended
for all digital controls. CATALOG UPC
DESCRIPTION
NO. CODE

90058-1 81024 Surge Suppressor

DIGITAL
CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 93 USA 800.321.5847 www.nsiindustries.com TORK 94
IN-WALL TIMERS
FEATURES
QUICK LOOK
SS720A SERIES
24 HOUR OR 7 DAY
DIGITAL IN-WALL
TIME SWITCH
SPECIFICATIONS

TIMING ACCURACY: Line frequency.


INPUT VOLTAGE: 125VAC, 60Hz.
WIRE SIZE: #14AWG.
OPERATING TEMPERATURE:
32F to +104F (0C to +40C).
APPLICATIONS

Outdoor security lighting


D1060
SS700Z SS721Z SS720A 701A SSA SSA-R24 SS
D212
A C Interior lights for lived-in look
Fans and motors
Page No. 99 99 98 101 102 102 103 104 105 106 Appliances
7 Day 7 Day 7 Day 24 Hour Auto OFF Auto OFF Auto OFF Auto OFF Auto OFF Auto OFF
Timer Type
Digital Digital Digital Mechanical Digital Digital Electronic Electronic Mechanical Mechanical

24/120/
Voltage 120/277 120/277 120 120 120/277 24 120 125/250/277 125/250/277
208-240/277

5 min-12 hr 5 min-12 hr 10-60 min. Various Various


ON 1 min. 1 min. 1 min. 30 min. 1 min-18 hr
Minimum 10 min-8 hr 10 min-8 hr 2-12 hr 2 min-12 hr 2 min-12 hr
Settings
OFF 1 min. 1 min. 1 min. 30 min.
ORDERING INFO
Manual Override Yes Yes Yes Yes
FEATURES CATALOG UPC INPUT SUPPLY
COLOR
NO. CODE (VAC) 60 Hz

Sunrise/Sunset Yes Yes SCHEDULING: 7 ON and OFF pairs of set SS720A 14017 120 White
points for individual programs on each day of
the week. Minimum setting is 1 minute. NEW! SS720AA 14018 120 Light Almond
ON/OFF Set Points 10 Pair 10 Pair 7 Pair 24 RANDOM MODE: Varies ON and OFF
times to create "lived in" look when away.

Flash Warning Yes Yes Yes DAYLIGHT SAVING: Manual button push CONTACT RATINGS
for one hour adjustment.
TYPE VOLTAGE RATING
MANUAL OVERRIDE: Until the next
Audible Warning Yes Yes Yes regularly scheduled ON or OFF, automatic
General Purpose 120VAC 15A
operation then resumes.

Power Outage Backup Capacitor Capacitor Battery Capacitor Capacitor WIRING: Requires a neutral. Resistive 120VAC 15A

CLOCK FORMAT: AM/PM. Tungsten 120VAC 15A


Switch Type SPST SPST SPST SPST SPST SPDT SPST or SPDT SPST SPST SPST or DPST POWER OUTAGE BACKUP: Rechargeable
Motor 120VAC 1HP
Ni-MI battery retains time and schedule.
WALL PLATE: Supplied with standard single Electronic Ballast 120VAC 500VA
Resistive Ratings 16A 16A 15A 15 & 20A 800W/1200W 1A 4A or 7.5A 15 20/10/10A 20/10/10A gang decorator wall plate.

TORK 97 TORK 98
SS700Z & SS721Z SPECIFICATIONS CONTACT RATINGS
BACKUP WITHOUT
SERIES NEW!
BATTERY, ECO FRIENDLY! TIMING ACCURACY: Line frequency. TYPE
SS700Z SERIES
RATING
VOLTAGE
SS721Z SERIES
RATING
SUNSET / SUNRISE, ASTRONOMIC
7 DAY IN-WALL TIMER INPUT VOLTAGE: 120/277VAC, 50/60Hz. Resistive 16A 120/277VAC 16A
WIRE SIZE: #12AWG input/output - #16AWG
3-way (remote). Ballast 10A 120/277VAC 13A

responsible
energy OPERATING TEMPERATURE: Tungsten 8A 120VAC 8A
32F to +104F (0C to + 40C).
APPLICATIONS CALIFORNIA Title 24 Pilot Duty 360VA 120VAC 720VA
ASHRAE 90.1
Motor 12HP 120VAC 1HP
Outdoor security lighting With wall plate
Interior lights for lived-in look (not included) WIRING DIAGRAMS
Fans and motors
Appliances
ORDERING INFO CONTACT RATINGS
CATALOG UPC INPUT SUPPLY SWITCH
COLOR
NO. CODE (VAC) 50/60 Hz TYPE

SS700Z 14019 120/277 SPST White

SS700ZA 14020 120/277 SPST Light Almond

SS721Z 14027 120/277 SPST White

SS721ZA 14028 120/277 SPST Light Almond

FEATURES

SCHEDULING: 10 ON and OFF pairs of MANUAL MODE: Does not run programs
set points for individual programs on each until set to AUTO (automatic) mode.
day of the week. 11 day groups speed
VACATION MODE: No operation when WIRING DIAGRAM: INSTALLATION SS721Z
programming. Minimum setting is 1 minute.
away.
ASTRONOMIC: Sunset and sunrise times
EASY WIRING:
are adjustable from 10- 60 Northern Black
SS700Z does not require a neutral, can be H
Blue Black
or Southern latitudes. Can be individually
used as a 3-way switch.
offset +/- 1-240 minutes for earlier or later
SS721Z Requires a neutral, can be used as Red
operation. Load

a 3-way switch. White

RANDOM MODE: Varies ON and OFF


CLOCK FORMAT: AM/PM.
times to create lived in look when away. N N
POWER OUTAGE BACKUP: Permanent
DAYLIGHT SAVING: Automatic Ground
schedule retention. Supercapacitor provides 2 WIRING DIAGRAM: THREE-WAY INSTALLATION SS721Z
adjustment (can be omitted).
days of real time backup. Connect a wire inside the gang-box between Traveler A and Hot.

LEAP YEAR: Automatic Compensation.


COMMERCIAL GRADE SPECS: Control ORDERING INFO
Green

MANUAL OVERRIDE: Until the next lighting contactors and 277VAC loads. Black Blue Black
regularly scheduled ON or OFF, automatic Compatible with CFL lamps. Traveler A

operation then resumes. H


Black
Red Load
Traveler B
White

N N

Ground

Green

IN-WALL TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 100
TORK 99 USA 800.321.5847 www.nsiindustries.com
701A & 711A SERIES SPECIFICATIONS
SPECIFICATIONS SSA SERIES SPECIFICATIONS
24 HOUR DIGITAL AUTO OFF
TIMING ACCURACY: .002%.
IN-WALL TIME SWITCH INPUT VOLTAGE: 125VAC, 60Hz. IN-WALL
WIRE SIZE: #14AWG. TIME SWITCH INPUT VOLTAGE:
120/277 VAC, 50/60Hz.
OPERATING TEMPERATURE:
32F to +104F (0C to +40C). WIRE SIZE: #18AWG.
OPERATING TEMPERATURE:
ORDERING INFO 0F to +100F (-17C to +37C).
APPLICATIONS APPLICATIONS
CATALOG UPC TIME OUTPUT
INPUT SUPPLY
NO. CODE SETTINGS CONTACTS
Porch or patio Offices, meeting rooms, library aisles
Stock and equipment rooms Minutes: 5, 15, 30
Doorway SSA100 14010 120/277 VAC SPST
Hours: 1, 3, 6, 9, 12
Pool Exhaust fans work areas, utility
Minutes: 10, 20, 40
Outdoor security lighting rooms, bathrooms SSA200 14011 120/277 VAC
Hours: 1, 112, 2, 4, 8
SPST
Hot tub heaters and circulating pumps Minutes: 5, 15, 30
SSA100R-24 14014 24VAC/24VDC SPDT
Timed override lighting and HVAC for Hours: 1, 3, 6, 9, 12
after hours and for loads controlled SSA200R-24 14015 24VAC/24VDC
Minutes: 10, 20, 40
SPDT
by electromechanical or digital time Hours: 1, 112, 2, 4, 8
Momentary Switch
switches. LCS115M 82082 SPST
for Override (white)

CONTACT RATINGS
TYPE VOLTAGE RATING
FEATURES
ORDERING INFO Tungsten 120VAC 800W
8-IN-1 TIMING: Choose from 8 preset ON 120VAC 800W
Ballast
FEATURES CATALOG UPC INPUT SUPPLY
COLOR intervals. SSA100/200 277VAC 1200W
NO. CODE (VAC) 60 Hz Motor 120VAC 16HP
MANUAL SCROLL-UP: Option allows Pilot Duty 120VAC 240VA
SCHEDULING: Minimum ON setting is 701A 10113 125 White
adjustment in 10 minute intervals. 30V 30V 1A
30 minutes. Dial has 48 captive trippers. SSA100/200R-24
1V min. 1V min. 100A
NEW! 701AA 10118 125 Light Almond FLASH WARNING: Optional flicker feature
BYPASS SWITCH: Slide switch for ON, turns load off for 1 second, 2 minutes before
OFF, or TIMER (automatic) operation. 711A 10114 125 White end of timed cycle and again 1 minute before
WIRING DIAGRAMS
VACATION MODE: Set timer OFF with end of timed cycle. SSA100/200
no change of tripper settings. CONTACT RATINGS AUDIBLE WARNING: Optional beep will BLACK HOT
GREEN 120V GROUND
WIRING: Requires a neutral. RATING
sound every 12 seconds during the last 2 GREEN /YELLOW 277V GROUND

TYPE VOLTAGE minutes of timed cycle. RED NEUTRAL


CLOCK FORMAT: AM/PM marked on 701A SERIES 711A SERIES LOAD

dial. TAMPER RESISTANT: Time ON interval


General Purpose 125 VAC 20A 15A
preset hidden behind wall plate.
WALL PLATE: Supplied with single gang RED (+) 24VAC
or
wallplate. Resistive 125 VAC 20A 15A EASY SET: Dip switches provide quick set-up BLACK () VDC

of timing and options. ORANGE NC


Tungsten 125 VAC 1500W 1250W BLUE C
EASY WIRING: No neutral needed, great REMOTE
OVERRIDE
GREY
NO

Motor 125 VAC 1 HP 12HP for retrofit. YELLOW


YELLOW
BACKLIT DISPLAY: Numerical read-out of
time remaining includes graphic bar showing SSA200R-24
time remaining in 10% increments. Stands out USING TRP TRANSFORMER RELAY POWERPACK 20 AMP
LOAD
strongly in lighted and dark areas. RED L

RED

RED
BLACK
WALL PLATE: Supplied with white standard RED
ORANGE
single gang decorator wall plate. NC

TORK
BLACK

TRP
BLUE C
REMOTE GREY
SSA-R24: Offers low voltage control with OVERRIDE NO BLUE
YELLOW
SPDT output and includes momentary input.

WHITE

BLACK
YELLOW LOW
VOLTAGE N L

IN-WALL TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 102
TORK 101 USA 800.321.5847 www.nsiindustries.com
SS SERIES SPECIFICATIONS D SERIES SPECIFICATIONS
SPECIFICATIONS
AUTO OFF ELECTRONIC AUTO OFF NEW!
IN-WALL TIME SWITCH TIMING ACCURACY: IN-WALL TIME SWITCH TIMING ACCURACY: Line voltage.
5% @ 60 to 80F. INPUT VOLTAGE: 120VAC, 60Hz.
INPUT VOLTAGE: WIRE SIZE: #14AWG.
24/120/208-240/277VAC, 50/60Hz.
OPERATING TEMPERATURE:
WIRE SIZE: #18AWG. 32F to 122F (0C to 50C).
OPERATING TEMPERATURE:
APPLICATIONS APPLICATIONS
0F to +100F (-17C to +37C).

Bathroom fans and lights Whole house fans


Indoor/Outdoor lighting Indoor/Outdoor lighting
Storage areas Bathroom fans and lights
Hospitality areas Self storage

ORDERING INFO ORDERING INFO


INPUT
FEATURES CATALOG UPC INPUT SUPPLY WARNING BEFORE SWITCH FEATURES CATALOG UPC
SUPPLY
TIME OUTPUT
NO. CODE (VAC) 50/60Hz TIME OUT TYPE NO. CODE (VAC) 60Hz SETTINGS CONTACTS

VARIABLE TIMING: Choose from 1 minute SS20 14005 24/120/208-240/277 None Single pole VARIABLE TIMING: D212H 14021 120 Ivory 2, 4, 8, 12 HOURS
to 18 hours. Button push changes time ON setting.
SS20F 14008 24/120/208-240/277 *Flicker Single pole D1060M: 10, 20, 30, 60 minute. D212HA 14022 120 Light Almond 2, 4, 8, 12 HOURS
FLASH WARNING: F suffix models with D212H: 2, 4, 8, 12 hour.
flicker feature turns load off for 12 second, 2 SS13F 14007 24/120/208-240/277 *Flicker 3-way D212HW 14023 120 White 2, 4, 8, 12 HOURS
minutes before end of timed cycle and again 1 LED DISPLAY: Indicator moves to new range
minute before end of timed cycle. SS13B 14006 24/120/208-240/277 **Beep 3-way as timer counts down. D1060M 14025 120 Ivory 10, 20, 30, 60 MINUTES
AUDIBLE WARNING: B" suffix model will *Flicker feature turns load OFF for second, 2 minutes before end of timed cycle and again 1 minute TAMPER RESISTANT: Time ON interval preset.
D1060LA 14024 120 Light Almond 10, 20, 30, 60 MINUTES
buzz that every 12 seconds during the last 2 before end of timed cycle.
**Beep feature will begin a second audible warning every 12 seconds during the last 2 minutes of EASY SET: No adjustments, just wire and go!
minutes of timed cycle. timed cycle. D1060MW 14025 120 White 10, 20, 30, 60 MINUTES
WIRING: Requires a neutral.
TAMPER RESISITANT: Time ON interval
preset is hidden behind wall plate. CONTACT RATINGS THREE COLORS: Ivory, Light Almond, White.
MINIMUM LOAD
CONTACT RATINGS
EASY SET: Small screw driver adjustment CONTACT
TYPE
RATINGS VOLTS WATTS
provides quick set-up of timing. TYPE VOLTAGE RATING
.25-4.0A Resistive 24 6
EASY WIRING: No neutral needed, great .25-4.0A Ballast* 120 30
SS13F & General Purpose 120VAC 15A
for retrofit. .25-4.0A Tungsten 208 50
SS13B 18HP @ 120VAC 240 60 Resistive 120VAC 1000W
3-WAY: SS13 SERIES replaces standard 13HP @ 240VAC 277 70
3-way switch with no re-wiring. .50-7.25A Resistive 24 12 Tungsten 120VAC 1000W
COLOR: White. .50-7.25A Ballast* 120 60
SS20 & .50-4.0A Tungsten 208 105
SS20F Motor 120VAC 14HP
16HP @ 120VAC 240 120
12HP @ 204VAC 277 150
*Not compatible with compact fluorescent lamps (CFL) and electronic fluorescent ballasts.

IN-WALL TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 104
TORK 103 USA 800.321.5847 www.nsiindustries.com
A SERIES SPECIFICATIONS C SERIES SPECIFICATIONS
SPRINGWOUND AUTO OFF COMMERCIAL STYLE
INPUT VOLTAGE:
IN-WALL TIME SWITCH 125/250/277VAC, 50/60Hz.
SRINGWOUND AUTO OFF INPUT VOLTAGE:
IN-WALL TIME SWITCH 125/250/277VAC, 50/60Hz.
TERMINAL SIZE: #12AWG.
TERMINAL SIZE: #12AWG.
OPERATING TEMPERATURE:
OPERATING TEMPERATURE:
32F to 122F (0C to 50C).
32F to 122F (0C to 50C).
ORDERING INFO
APPLICATIONS APPLICATIONS
CATALOG UPC HOLD
COLOR Wallplate
NO. CODE FEATURE
Ventilating fans included
Whole house fans Wallplate not 15 MINUTE MAX.
included HVAC
Indoor/Outdoor lighting A515MH 15020 Ivory
Whirlpools
Bathroom fans and lights With Hold
A515MHW 15120 White Self storage
Self storage
Motors and pumps
A515M 15013 Ivory

A515MW 15113 No Hold White

A515MA 15127 Light Almond


30 MINUTE MAX.
A530MH 15021 Ivory
With Hold
A530MHW 15121 White

A530M 15014 Ivory


CONTACT RATINGS CONTACT RATINGS ORDERING INFO
A530MW 15114 No Hold White CATALOG UPC HOLD
FEATURES TYPE VOLTAGE RATING FEATURES TYPE VOLTAGE RATING NO. CODE FEATURE
A530MA 15128 Light Almond
15 MINUTE MAX.
125VAC 20A 60 MINUTE MAX. VARIABLE TIMING: Twist knob for time 125VAC 20A
VARIABLE TIMING: Twist knob for time Resistive 250VAC 10A Resistive 250VAC 10A C515M 15501 No Hold
ON setting. Time ON lengths from 15 minutes 277VAC 10A A560MH 15022 Ivory ON setting. Time ON lengths from 15 minutes 277VAC 10A
to 12 hour vary by model. 125VAC 20A With Hold to 12 hour vary by model. 125VAC 20A 30 MINUTE MAX.
Inductive 250VAC 10A A560MHW 15122 White Inductive 250VAC 10A
HOLD FEATURE: Some models have position 277VAC 10A HOLD FEATURE: Some models have position 277VAC 10A C530M 15503 No Hold
for constant ON. A560M 15015 Ivory for constant ON. 60 MINUTE MAX.
Tungsten 125VAC 7A No Hold Tungsten 125VAC 7A
EASY SET: No adjustments. Just wire and go! A560MW 15115 White EASY SET: No adjustments. Just wire and go! C560M 15505 No Hold

EASY WIRING: No neutral required. Great 125VAC 1HP 2 HOUR MAX. EASY WIRING: No neutral required. Great 125VAC 1HP
Motor Motor C560MH 15506 With Hold
250VAC 2HP 250VAC 2HP
for retrofit! Use as single or in multi-gang box A502HHW 15123 With Hold White for retrofit!
with no de-rating. SWITCH TYPE: SPST, except C460M and NEW! C460M* 15011 No Hold
A502H 15016 Ivory
SWITCH TYPE: SPST. No Hold C412H DPST 2 HOUR MAX.
A502HW 15116 White COLOR: Metal-brushed aluminum.
COLOR: Ivory, Light Almond, White. C502H 15507 No Hold
6 HOUR MAX.
WALL PLATE: Fits standard or decorator
POT

0 0
WALL PLATE: Includes real metal wall plate 6 HOUR MAX.
A506HHW 15125 With Hold White
12

with screw mounting, to add extra security for


12 3

style wall plates, see below (not included). 9


9 6
C506H 15511 No Hold
A506H 15018 Ivory
commercial applications.
12 HOUR MAX.
No Hold
POT
A506HW 15118 White C512H 15513 No Hold
1
2
0 0

12 HOUR MAX.
12 T OR K
12 3

C512HH 15514 With Hold


9
0
9 6 3
21
1
2

6
9

A512HH 15026 Ivory


With Hold NEW! C412H* 15010 No Hold
A512HHW 15126 White
2

T OR K
1

*DPST switch type.


0
A512H 15019 Ivory
No Hold
21
3
1
2

CAUTION: This timer is not to be used in precision timing applications where CAUTION: This timer is not to be used in precision timing applications where
9
6

A512HW 15119 White


inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.). inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).
All A Series timers have SPST switch type.

IN-WALL TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 106
TORK 105 USA 800.321.5847 www.nsiindustries.com
OCCUPANCY SENSORS
SENSOR TECHNOLOGY OSWS SERIES SPECIFICATIONS
PIR SENSOR, DECORATOR STYLE
& PLACEMENT GUIDE IN-WALL CONTACT RATINGS:
OSWS9P-120: 1000W Ballast, 800W
OCCUPANCY SENSOR responsible
energy Incandescent, 16HP at 120VAC.
TECHNOLOGY PLACEMENT GUIDELINES CALIFORNIA Title 24
OSWS9P-277: 1800W Ballast at 277VAC.
OSWS9PD & OSWS9PDM: 1000W Ballast, 800W
PIR AND ULTRASONIC CEILING SENSOR ASHRAE 90.1
Incandescent, 16HP at 120VAC, 1800W Ballast
A Passive Infrared Sensor (PIR sensor), is a device that measures infrared A Ceiling Sensor provides a 360 coverage pattern of up to 1200 at 277VAC.
radiation (IR), or heat, from objects in its field of view. Because it only receives square feet when using passive infrared only. When using dual APPLICATIONS ADJUSTABLE TIME DELAY:
information, it is considered passive. The IR sensor views a human body as an technology the coverage pattern extends to over 2000 square feet. 30 seconds - 30 minutes.
IR generating object. The lens of the occupancy sensor breaks up the field of Barriers within the space that block line-of-sight to sensor detection will Offices and hotels
view into IR sensitive bands. The occupancy sensor is designed to only react decrease coverage area when using passive infrared by itself, ultrasonic OPERATING TEMPERATURE:
Classrooms 32 to 131F (0 to 55C).
when heat is sensed moving from band to band. For PIR occupancy sensors to dual technology will allow the sensor to get around the obstructions.
Conference rooms
work object must have direct line of sight to the PIR sensor. Designed for ceiling mounting at a height of 8-10 feet (mounting MOUNTING: Box mount.
Lavatories
An Ultrasonic Sensors (US sensor) is a technology that works on a principle sensor at greater heights decreases the sensitivity to motion, while Hallways
similar to radar or sonar. It is an active technology that sends and receives. It lower mounting height will decrease range).
emits an inaudible high-frequency sound wave and evaluates the echo which The sensor needs a visually unobstructed view of the normally
is received back after bouncing around in the room. This allows the sensor to occupied workspace and entry door(s). FEATURES
evaluate the whole room and can look over walls and obstructions to identify Avoid sensor placement with a direct view out a doorway. Placing the
movement. sensor offset from the center and away from the door is OSWS9P-120, OSWS9P-277 & OSWS9PD:
recommended. OPERATION: Automatic ON and automatic OFF
Both technologies show higher sensitivity closer to the sensor to allow small
If the occupant cannot see a PIR sensor from their normal work based on occupancy detection.
movements to be noticed. Sensitivity reduces further away from the sensor and
may require a walking step to activate the sensor. position, the sensor will not be able to detect their presence. ORDERING INFO
OFF DELAY: Selectable from 30 seconds to 30
File cabinets, partitions, or walls are typical types of obstructions. If minutes. CATALOG UPC OUTPUT
there are other obstructions between the sensor and the occupant, an NO. CODE
DESCRIPTION
CONTACTS
ultra-sonic or dual technology ceiling sensor is recommended. MANUAL OVERRIDE: Includes ON and OFF
PLACEMENT GUIDELINES When the light level feature is used, mount within 15 feet of the switch. OSWS9P-120 82077 PIR in-line wall switch 120VAC
WALL SENSOR widows or skylight and avoid mounting the sensor close to lighting EASY WIRING: No neutral required. Great for
fixtures. OSWS9P-277 82078 PIR in-line wall switch 277VAC
retrofit.
A Wall Switch Sensor provides a 180 coverage pattern, extending outward Place the sensor no closer than 5 feet to an HVAC airCEILING
duct whenAND
usingWALL OCC SENSOR SENSING PATTERNS
CEILING AND WALL OCC SENSOR SENSING PATTERNS PIR in-line wall switch
from the sensor. This will allow for instant turn ON when an occupant enters the dual technology sensors. OSWS9PD ALSO INCLUDES: OSWS9PD 82079 120/277VAC
with ambient light sensor
space. Total area covered will be over 400 square feet. Open office designs encourage placement of the sensors to allow SENSITIVITY ADJUSTMENT: For PIR range. PIR in-line wall switch
OSWS9PDM 82080 120/277VAC
Proper placement gives the sensor a clear line of sight to the entry door overlapping coverage of small motion range and a clear view into DAYLIGHTING MODE: Adjustable level to
manually activated
without viewing the hallway. each cubicle. Walking step motion may cover the entry to the space. keep lights OFF even when occupancy is sensed if
The occupant must be able to see the sensor from their normal work position Dual technology units provide added sensitivity to small motion. adequate light exists in the room from windows or WIRING & COVERAGE DIAGRAMS
otherwise the sensor will not be able to detect their presence. skylights.
For offices where there are other obstructions between the sensor and the Wall Mounting Box
occupant or the entry door, a ceiling sensor is required. OSWS9PDM - VACANCY SENSOR:
OPERATION: Manual push button on and then
automatic OFF.
CEILING AND WALL OCC SENSOR SENSING PATTERNS LINE
OFF DELAY: Selectable from 30 seconds to 30 (Black)

minutes.
LOAD
(Red)
SENSITIVITY ADJUSTMENT: For PIR range.
DAYLIGHTING MODE: Adjustable level to
GND
keep lights OFF even when occupancy is sensed if (Green)

adequate light exists in the room from windows or


skylights.
Top and Side Coverage Pattern Diagrams
MANUAL OVERRIDE: Includes ON and OFF
switch.
EASY WIRING: No neutral required. 35'

16'

180 Coverage

4.0' 15
15

35'
TORK 109 TORK 110
OSC15PLS SPECIFICATIONS OSC12PL SPECIFICATIONS
PIR SENSOR, WITH AMBIENT LIGHT
OVERRIDE, MULTI-VOLTAGE VOLTAGE: 120 - 347VAC. & OSC5PL VOLTAGE: 24VDC.
PIR SENSOR CURRENT CONSUMPTION: 9mA.
INTEGRAL POWERPACK, responsible
energy ADJUSTABLE LIGHT LEVEL: 5FC - 200FC. responsible
energy
CELING MOUNTING
CELING MOUNTED ADJUSTABLE TIME DELAY: 30 seconds -
POWER SUPPLY: TRP-U Power Pack
CALIFORNIA Title 24 OCCUPANCY SENSORS CALIFORNIA Title 24
(up to 6 units).
OCCUPANCY SENSOR ASHRAE 90.1 30 minutes (DIP switch). ASHRAE 90.1
ADJUSTABLE LIGHT LEVEL:
TEST MODE: 5 seconds, upon initial power-up
10FC - 150FC.
or DIP switch reset.
APPLICATIONS APPLICATIONS
ADJUSTABLE TIME DELAY:
PIR COVERAGE: 1200 sq. ft.
5 seconds - 30 minutes (DIP switch).
Offices and hotels sensitivity adjustment: Offices
Classrooms Classrooms TEST MODE: 5 seconds, upon initial
Full or 50% low (DIP switch).
power-up or DIP switch reset.
Conference rooms Conference rooms
operating temperature:
Lavatories 32 to 131F (0 to 55C).
Lavatories PIR COVERAGE: 1200 sq. ft.
OSC5PL / OCCUPANCY SENSOR ASSORTED
OSC5PL SENSING
/ OCCUPANCY PATTERNS
SENSOR ASSORTED SENSING PATTERNS
Hallways Hallways SENSITIVITY ADJUSTMENT:
mounting: Ceiling or box mount.
18ft 18ft Full or 50% low (DIP switch).
FEATURES contacts: SPST dry contacts. FEATURES
MOUNTING: Ceiling or box mount.
contact ratings: 800W Incandescent, OPERATION: Automatic ON and automatic OFF
OPERATION: Automatic ON and automatic OPERATING TEMPERATURE:
1000W ballast at 120VAC. 1800W Ballast at based on occupancy detection.
OFF based on occupancy detection. 32 to 131F (0 to 55C).
277VAC. 2200W Ballast at 347VAC.
OFF DELAY: Selectable from 30 seconds to OFF DELAY: Selectable from 30 seconds to 30
minutes. ORDERING INFO
30 minutes. 12ft 12ft
ECOSETTING: Learns typical use patterns and CATALOG UPC INPUT COVERAGE
DAYLIGHTING MODE: Selectable to DESCRIPTION
NO. CODE SUPPLY (FEET)
keeps lights off when occupancy is sensed adjusts the OFF delay for the most efficient time.
if adequate light exists in the room from WALK-THROUGH MODE: Selectable to turn OSC5PL 82083 24VDC 500 White
windows or skylights. ORDERING INFO lights OFF after only 3 minutes. If no activity is
OSC12PL 82081 24VDC 1200 White
POWER SWITCHING: Built-in power pack detected after 30 seconds of occupancy detection,
CATALOG UPC INPUT COVERAGE
for direct line voltage control. NO. CODE SUPPLY (FEET)
DESCRIPTION lights turn OFF.
TRP-U 82030 120/277VAC Power Pack
DAYLIGHTING MODE: Selectable to keep lights
OSC15PLS 82076 120-347VAC 1200 WHITE LCS115M 82082 Momentary Switch
OFF when occupancy is sensed if adequate light
exists in the room from windows or skylights.
PRESENTATION MODE: Optional MANUAL OFF COVERAGE DIAGRAMS
WIRING & COVERAGE DIAGRAMS
by an accessory wall switch (LCS115M). Sensor
will keep lights OFF while movement in room is
DIP SWITCH
detected, then return to automatic ON after 5
Audible Alert
OSC15PLS minutes. Sensitivity 1 Time Delay 2 3 4 7
50% 5 Sec/EcoSet Disabled
SENSOR
VACANCY MODE: Optional MANUAL ON by 100% 30 Seconds Enabled
5 Minutes
an accessory wall switch (LCS115M) and then Walk Through 5
10 Minutes
Visible Alert 8
RED WHITE (NEUTRAL) Disabled Disabled
N LOAD automatic OFF. 15 Minutes
BLACK (LINE) Enabled Enabled
20 Minutes
MANUAL OVERRIDE: Optional manual control Vacancy 6 25 Minutes Hold ON 9
RED Disabled Disabled
by an accessory wall switch (LCS115M) for ON and 30 Minutes
Enabled
Enabled
OFF. OFF ON Factory Setting

WARNING BEFORE OFF: Optional visual flash


warning and/or audible beep warning one minute OSC12PL OSC5PL
before turn OFF.
PLUG TERMINAL: Quick disconnect for sensor.
POWER SWITCHING: Transformer relay power 22
6.7

pack (TRP-U) required to power sensor and provides


line voltage switching. (see page 116 for product 11 7 3 3 7 11

information).

OCCUPANCY
SENSORS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 111 USA 800.321.5847 www.nsiindustries.com TORK 112
OSC2OUP SPECIFICATIONS OSC SERIES SPECIFICATIONS
DUAL TECHNOLOGY ULTRASONIC, CEILING MOUNTING
VOLTAGE: 24VDC. VOLTAGE: 24VDC.
CELING MOUNTED OCCUPANCY SENSORS
PIR/ULTRASONIC CURRENT CONSUMPTION: 33mA. CURRENT CONSUMPTION: 33mA.
responsible responsible
energy energy
OCCUPANCY SENSOR POWER SUPPLY: TRP-U Power Pack POWER SUPPLY: TRP-U Power Pack
CALIFORNIA Title 24 (up to 3 units). CALIFORNIA Title 24 (up to 4 units).
ASHRAE 90.1 ASHRAE 90.1
ADJUSTABLE TIME DELAY: ADJUSTABLE TIME DELAY:
8 - 40 minutes. 8 - 40 minutes.
APPLICATIONS APPLICATIONS
TEST MODE: 8 seconds, upon initial TEST MODE: 8 seconds, upon initial
power-up for 1 hour. power-up for 1 hour.
Offices and hotels Offices and hotels
Classrooms US COVERAGE: 2000 sq. ft. (adjustable). Classrooms US COVERAGE: 2000 sq. ft. (adjustable).
Conference rooms PIR COVERAGE: 1500 sq. ft. (adjustable). Conference rooms SENSITIVITY ADJUSTMENT: Manual
Lavatories Lavatories setting range of 50%.
SENSITIVITY ADJUSTMENT: Individual setting
Hallways range for ultrasonic of 50% and PIR of 75%. Hallways
ULTRASONIC OUTPUT:
OSC5U: 40kHz
ULTRASONIC OUTPUT: 32Hz
FEATURES FEATURES OSC10U/OSC20U: 32kHz
MOUNTING: Ceiling or box mount.
OPERATION: Automatic ON and automatic MOUNTING: Ceiling or box mount.
OPERATING TEMPERATURE: OPERATION: Automatic ON and automatic
OFF based on occupancy detection. OFF based on occupancy detection. OPERATING TEMPERATURE:
32 to 131F (0 to 55C).
OFF DELAY: Selectable from 8 to 40 32 to 104F (0 to 40C).
HUMIDITY: 0 to 95% R.H. non-condensing for OFF DELAY: Selectable from 8 to 40
minutes. minutes. HUMIDITY: 0 to 95% R.H. non-condensing
indoor use only.
ECOSETTING: Learns typical use patterns for indoor use only.
ECOSETTING: Learns typical use patterns
and adjusts the OFF delay for the most and adjusts the OFF delay for the most
efficient time. efficient time.
MOTION INDICATION: Red for infrared MOTION INDICATION: Green for ORDERING INFO
motion, Green for ultrasonic motion. ultrasonic motion. Indicator may be disabled. CATALOG UPC INPUT COVERAGE
Indicators may be disabled. NO. CODE SUPPLY (FEET)
DESCRIPTION
ORDERING INFO POWER SWITCHING: Transformer relay
POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power OSC5U 82072 24VDC 500 SQ FT White
power pack (TRP-U) is required to power CATALOG UPC INPUT COVERAGE
DESCRIPTION sensor and provide line voltage switching
sensor and provide line voltage switching NO. CODE SUPPLY (FEET)
(see page 116 for product information). OSC10U 82073 24VDC 1000 SQ FT White
(see page 116 for product information). 2000 ft US
OSCS20UP 82075 24VDC White
1500 ft PIR
OSC20U 82074 24VDC 2000 SQ FT White
TRP-U 82030 120/277VAC Power Pack
TRP-U 82030 120/277VAC Power Pack

COVERAGE DIAGRAMS COVERAGE DIAGRAMS

OCCUPANCY
SENSORS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 113 USA 800.321.5847 www.nsiindustries.com TORK 114
ELS SPECIFICATIONS TRP-U SPECIFICATIONS
INDOOR LIGHT LEVEL responsible
INTELLEGENT
energy
ELECTRONIC VOLTAGE: 24VDC. POWER PACK VOLTAGE: 120/230/277VAC, 50/60Hz.
CCUPANCY CALIFORNIA Title 24
CURRENT CONSUMPTION: 9mA. LOAD REQUIREMENTS:
SENSOR ASHRAE 90.1
POWER SUPPLY: TRP-U Power Pack (up
Ballast 20amp @120/277VAC.
Incandescent 20amp@120VAC.
to 4 units).
Motor 1HP @120/240VAC.
operating temperature: Output 150mA @24VDC (with relay connected).
50 to 104F (10 to 40C).
APPLICATIONS APPLICATIONS LOW VOLTAGE INPUT:
mounting: Ceiling or box mount. Control ON: 12 - 24VDC
Offices Power and switching Hold ON: 12 - 24VDC
Classrooms for occupancy sensors Hold OFF: 12 - 24VDC
Conference rooms Power and switching MOUNTING: Box mount to 12" KO.
Hallways for SSA R-24 series operating temperature:
BAS input compatible 32 to 131F (0 to 55C).
Demand shedding applications
FEATURES Device override to hold on
Momentary switched override
DAYLIGHTING CONTROL: Turns OFF Low voltage 3-way wiring
when sufficient daylight present.
ADJUSTABLE LIGHT LEVEL:
FEATURES
10FC - 250FC (DIP switch).
EASY MOUNTING: Low voltage Class 2 OPERATION: Switches line voltage loads ON/OFF
wiring allows recommended mounting about ORDERING INFO based on a contact closure from an occupancy sensor,
3 feet from daylight sources. AUTO OFF switch, or relay. ORDERING INFO
CATALOG UPC INPUT
ADJUSTABLE OFF DELAY: DESCRIPTION INTELLEGENT INPUT: Three additional input wires: CATALOG UPC INPUT
NO. CODE SUPPLY DESCRIPTION
NO. CODE SUPPLY
Set from 3 to 15 minutes. 1. Hold OFF for demand shed control.
ELS-1 82049 24VDC Indoor Daylight Sensor 2. Hold ON override of local devices such as sensors.
PRESET ON DELAY: 30 seconds prevents TRP-U 82030 120/277VAC Power Pack
3. Momentary switch input for remote override.
false triggering. TRP-U 82030 120/277VAC Power Pack
MULTI-VOLTAGE: Tri-voltage input for flexibility. LCS115M 82082 Momentary Switch

QUICK MOUNTING: Snaps into 12" box KO.


WIRING DIAGRAMS WIRING DIAGRAMS
ON

1 2 3 4 5 6 7 Existing TRP-U
Power Pack 277V New Junction
Box LOW VOLTAGE WIRING
Model TRP2 Extension
or Power Pack 120V Box
Model TRP1

New Cover With


1/2 K.O. Provision

PHOTO SENSOR Bend Tabs After


ORIENTATION ARROW Inserting in K.O.
UNDER IVORY COVER Hole
New Extension Box
PROGRAMMABLE 7-SECTION SLIDE SWITCH FOOT CANDLE SELECTION* Only Used When
+
1 2 3 4 56 Low Voltage Wiring
SLIDE FOOT CANDLE FOR7 Has to be Enclosed

#1 10FC Warehouse
#2 25FC Corridors
Machine equipment display showroom (such as
#3 50FC automobile and farm equipment) LOBBY (such as
airport waiting area).
#4 75FC Classrooms, common office areas
#5 100FC Drafting rooms
#6 150FC Retail display areas
High critical areas, product sorting and grading,
#7 250FC paint quality control.
*Slide only one switch to ON for selection, all other switches remain OFF.

OCCUPANCY
SENSORS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 115 USA 800.321.5847 www.nsiindustries.com TORK 116
PLUG-IN TIMERS
400A SERIES 400D SERIES
INDOOR GENERAL PURPOSE 1875W INDOOR GENERAL NEW!
MECHANICAL MULTIPLE PURPOSE 1800W
responsible
ON/OFF TIMERS DIGITAL PROGRAMMABLE energy

ON/OFF TIMERS CALIFORNIA Title 24

ASHRAE 90.1

401A
460D
APPLICATIONS APPLICATIONS

Lamps, radios, televisions 405A


Lamps, radios, televisions
Appliances Appliances 455D
Automatically turn ON/OFF items Automatically turn ON/OFF items in
in the home, gives the home a NEW! the home, gives the home a "lived
"lived in" look while away. in" look while away.
402A 454D

FEATURES FEATURES
NEW! 422A 457Z
REPEAT SCHEDULE: Daily. REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING: Multiple ON/OFF times. VARIABLE TIMING:
460D, 454D, 455D: Manual Daylight Savings
ON/OFF: Manual ON/TIMER switch.
adjustment. Random mode for lived-in look. Manual
ENERGY SAVINGS: Works with CFLs and LED lamps. Override ON/OFF.
403A
457Z: Turns ON at Sunset; turns OFF at Sunrise or
other times; automatic DST adjustment; Random Mode
for lived-in look; Manual Override ON/OFF.
BACKUP: Battery back-up.
ENERGY SAVINGS: Works with CFLs and LED lamps.
ACCURACY: Digital accuracy to 1 minute.

ORDERING INFO ORDERING INFO


CATALOG UPC NO. OF TYPE OF VARIABLE TIMING NO. OF
RATINGS OUTLETS DESCRIPTION CATALOG UPC TYPE OF VARIABLE TIMING
NO. CODE PLUG SEGMENTS RATINGS OUTLETS DESCRIPTION
( ) NO. CODE ( ) PLUG SEGMENTS

401A 16001 1 Polarized Multiple ON/OFF Lighting Timer 15 minute 460D 16017 1 Polarized Daily Programmable Digital Timer
120VAC, 15A, 1800W General Purpose 24 ON/OFFs
402A 16002 125 VAC, 15A, 1875W Resistive 1 Grounded Heavy Duty 24 hour Timer 15 minute 120VAC, 15A, 1800W Resistive Different schedule for
454D 16009 1 Grounded Daily Programmable Digital Timer
120VAC, 1000W Tungsten each day of the week.
125VAC, 10A, 1250W Tungsten
403A 16013 125VAC, 13HP 1 Polarized Powerful & Compact Automatic Timer 30 minute 455D 16015 120VAC, 13HP, TV-5 2 Grounded Daily Programmable Digital Timer Multiple ON/OFFs

405A 16014 2 Grounded Heavy Duty 15 AMP Automatic Timer 15 minute 20 ON/OFFs
120VAC, 15A, 1800W General Purpose
120VAC, 15A, 1800W Resistive Different schedule for
125VAC 15A, 1875W Resistive 457Z 16016 2 Grounded Ultimate Plug-In 2-Outlet Timer each day of the week.
422A 16019 125VAC 500W Tungsten 1 Grounded Heavy Duty 24 hour 15AMP Timer 30 minute 120VAC, 960W Tungsten
120VAC, 13HP TV-5 ON at Sunset
125VAC TV-4 OFF at Sunrise

NOTE: " " = Indicates outlet location. NOTE: " " = Indicates outlet location.

PLUG-IN TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 119 USA 800.321.5847 www.nsiindustries.com TORK 120
600A SERIES 600D SERIES
OUTDOOR GENERAL PURPOSE 1875W OUTDOOR NEW! responsible
energy
MECHANICAL PLUG-IN GENERAL PURPOSE 1875W
PHOTOCELL COUNTDOWN 7 DAY DIGITIAL WITH CALIFORNIA Title 24

TIMERS PHOTOCELL, 7 DAY DIGITAL ASHRAE 90.1

OUTDOOR TIMERS Photocell

APPLICATIONS APPLICATIONS

Landscape or Christmas lighting


Landscape and Christmas lighting
Controls small pumps, fountains, motors
Control small pumps, fountains,
601A motors, etc.
Energy saving
602A
621D & 631D
(621D without photocell)
611A

611D
FEATURES FEATURES

REPEAT SCHEDULE: Daily. REPEAT SCHEDULE: 7 day programming.


VARIABLE TIMING: Multiple ON/OFFs, Manual ON/ VARIABLE TIMING: Manual Daylight Savings
TIMER switch. adjustment. Random mode for lived-in look.
PHOTO TIMER: Two styles Manual ON/TIMER switch. Multiple ON/OFF for
652A - Dial setting. ON at dusk and OFF 2, 4, 6, or 8 hours each day of the week.
later. 654A - Digital setting. ON dusk and OFF 1 to 9 hours 652A BACKUP: Battery back-up.
later or at random times.
ACCURACY: Digital accuracy to 1 minute.
ENERGY SAVINGS: Works with CFLs and LED lamps.
654A PHOTOCELL: 611D and 631D have built-in
photocell to always turn ON at dusk and OFF at 655D
ORDERING INFO dawn. Add a time OFF schedule 655D Remote
NO. OF
CATALOG UPC
RATINGS OUTLETS
TYPE OF
DESCRIPTION
VARIABLE TIMING WIRELESS REMOTE: 655D receives ON/OFF
NO. CODE ( ) PLUG SEGMENTS signal up to 80 feet away.
15 minutes
601A 16020 1 Grounded Mechanical Outdoor Timer, with18" cord Multiple ON/OFFs
125 VAC, 15A, 1875W General Purpose ORDERING INFO
125VAC, 15A, 1875W Resistive 15 minutes
602A 16021 125VAC, 10A, 1250W Tungsten 2 Grounded Mechanical Outdoor Timer, with18" cord NO. OF
Multiple ON/OFFs CATALOG UPC TYPE OF VARIABLE TIMING
125VAC, 12HP RATINGS OUTLETS DESCRIPTION
Wall Mountable 15 minutes NO. CODE ( ) PLUG SEGMENTS
611A* 16022 1 Grounded Mechanical Outdoor Timer, with 24" cord Multiple ON/OFFs
Wall Mountable Photocell & 7 Day Photo ON
Photo ON 611D 16018 125 VAC, 15A, 1875W General Purpose 1 Grounded Digital 2-in-1 Timer, with 24" cord Dawn or timed OFF
652A 16026 125VAC, 15A, 1875W General Purpose 2 Grounded Photocell Outdoor Timer with 6.5" cord
125VAC, 15A, 1875W Resistive Dawn or timed OFF 125VAC, 15A, 1875W Resistive
125VAC, 1000W Tungsten Wall Mountable, 7 Day Multiple ON/OFFs for
125VAc, 650W Tungsten Photo ON 621D 16056 2 Grounded
654A 16025 2 Grounded Photocell Outdoor Timer with 6.5" cord 125VAC, 8A Ballast Digital Timer, with 18" cord each day of the week
125VAC, 13HP, TV-5 Dawn or timed OFF
631D 16027 125VAC, 12HP 2 Grounded Wall Mountable Photocell & 7 Day Photo ON
*611A: 13HP Digital 2-in-1 Timer, with 18" cord Dawn or timed OFF
125VAC, 5A, 625W Resistive Remote control
655D* 16042 125VAC, 600W Tungsten
2 Grounded indoor/outdoor receiver Handheld remote ON/OFF

* ETL listed for U.S. and Canada.

NOTE: " " = Indicates outlet location. NOTE: " " = Indicates outlet location.

PLUG-IN TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 121 USA 800.321.5847 www.nsiindustries.com TORK 122
800 SERIES
OUTDOOR GENERAL NEW!
PURPOSE 1875W
MECHANICAL & DIGITAL
STAKE TIMERS

APPLICATIONS

Landscape and Christmas lighting


Other outdoor lighting
Energy saving

803B

806B

FEATURES

REPEAT SCHEDULE: Mechanical timer 24 hours. Digital


timer 7 day programming.
MECHANICAL TIMING: Multiple ON/OFFs, Manual ON/ 806D
TIMER switch.
DIGITAL TIMING: Manual ON/TIMER switch. Multiple
ON/OFF for each day of the week.
PHOTOCELL: 806D has optional built-in photocell to
always turn ON at dusk and OFF at dawn or 1 to 12 hours
later.
ENERGY SAVINGS: Works with CFLs and LED lamps.

ORDERING INFO
CATALOG UPC NO. OF TYPE OF VARIABLE TIMING
RATINGS OUTLETS DESCRIPTION
NO. CODE ( ) PLUG SEGMENTS
Mechanical Outdoor Stake Timer, 15 minutes
803B 16057 3 Grounded
125VAC, 15A, 1875W Resistive with 2' cord Multiple ON/OFFs
125VAC, 10A, 1250W Tungsten Mechanical Outdoor Stake Timer, 15 minutes
806B 16037 6 Grounded with 2' cord. 3 timed outlets and 3 untimed. Multiple ON/OFFs
Multiple ON/OFFs for each
Digital Outdoor Stake Timer, with 6' cord. 3 day of the week or Photo
806D 16038 125VAC, 15A, 1875W Resistive 6 Grounded timed outlets and 3 untimed. ON and Dawn or 1-12
hours OFF.

NOTE: " " = Indicates outlet location.

PLUG-IN TIMERS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 123 USA 800.321.5847 www.nsiindustries.com TORK 124
TORKALERT
ALARM SOUNDS
MECHANICAL MULTI-TONE TA875-1G1 24VDC HORN
STROBE HORNS ELECTRONIC ALARM CURRENT TYPICAL dB
TONE (AMPS) @10 FEET
HORNS BELL
HI-LO
0.020
0.025
91
96
24VDC &115VAC CHIME 0.028 93
SINGLE STROKE BELL 0.026 93
HORN 0.023 97
TA875-1G1 3 BEEPS, PAUSE 0.023 97
APPLICATIONS APPLICATIONS TA-MTS
SIREN 0.040 95
TA880-N5 SLOW WHOOP 0.040 96
High performance for industrial For indoor and outdoor use. TA-MTS 115VAC HORN
signaling applications. Offers high Superior sound penetration for ALARM AMPS @ 120VAC TYPICAL dB @10 FEET
TA5508H-G1 HIGH STANDARD
sound output, low current draw and various room conditions. Screw TONE HIGH STANDARD OUTPUT OUTPUT
dependable operation. Strobes use terminals accept #12AWG. HORN 0.050 0.042 85 82
xenon flashtube, ideal for maximum BELL 0.041 0.039 82 75
efficiency and reliability. ORDERING INFO HORN 2 0.050 0.040 85 79
CATALOG UPC INPUT INPUT dB
FEATURES CODE 3 HORN 0.050 0.042 82 75
NO. CODE VOLTAGE CURRENT @10 FEET CANDELA CODE 3 TONE 0.042 0.040 79 75
(AMPS) SLOW WHOOP 0.050 0.042 85 82
OPERATING TEMPERATURE:
TA880-N5 96015 120VAC 0.115 96 15 TA-MTS: -31F to +150F (-35C to +66C). SIREN 0.045 0.041 85 82
FEATURES
HI-LO 0.042 0.039 82 79
TA5508H-G1 96071 24VDC .059 strobe only 15/75 DIMENSIONS AND MOUNTING:
ALARM: Penetrating mechanical sound. TA-MTS: 4118H x 418W x 31732D ORDERING INFO
WIRING: Low current draw. NOTE: TA880-N5 For outdoor use, unit must be mounted in a TA-WBBF outdoor backbox. See page 138 Can be mounted on celing or wall.
for ordering. TA5508H-G1 for indoor mounting only. TA875-1G1: 434H x 434W x 138D CATALOG UPC INPUT DESCRIPTION
MOUNTING: 4" square surface mounting. NO. CODE VOLTAGE
1 gang, 2 gang or 4" square backbox.
20-31VDC,
TA875-1G1 97641 Multi-tone Electric Horn
24VDC
TA-MTS 97674 115 VAC Multi-tone Electric Horn

MECHANICAL
HORNS HEAVY DUTY
BELLS
4", 6", 10" DIAMETERS
ORDERING INFO AC VIBRATING BELLS
APPLICATIONS
CATALOG UPC INPUT INPUT CURRENT
NO. CODE VOLTAGE (AMPS)
Loud tone with typical decibel ORDERING INFO
SURFACE TYPE APPLICATIONS
output of 103 dB. Low frequency INPUT dB
TA874-N5 96023 120VAC, 60Hz 0.070 CATALOG UPC SHELL
resonation for strong penetration NO. CODE SIZE VOLTAGE CURRENT @ 10 COLOR
of noisy areas like boiler rooms, TA874-N5R
For indoor or outdoor applications. (AMPS) FEET
97613 120VAC, 60Hz 0.070 High sound output, durable and
water pumping stations, elevators (Red) TA340-4G5 96001 4 24VAC 0.320 81-90 Dawn Mist
and air compressor rooms. dependable performance. Ideal for
TA875-G1 97687 24VDC 0.035 schools and hopsitals. TA340-4N5 96002 4 120VAC 0.065 81-90 Dawn Mist
WITH WEATHERPROOF BACKBOX TA-WBBF UL LISTED FOR OUTDOOR USE
FEATURES TA876-N5 96026 120VAC, 60Hz 0.070
TA340-6G5 96003 6 24VAC 0.320 81-95 Dawn Mist
FEATURES
INPUT VOLTAGE: Wide input voltage HOUSING: Steel, painted Dawn Mist. TA340-6N5 96004 6 120VAC 0.065 81-95 Dawn Mist
ratings for compatibility with unregulated Resonant grill design for high sound TERMINAL SIZE: #12 - 22 AWG.
TA340-10G5 96005 10 24VAC 0.320 84-98 Dawn Mist
power supplies. output.
WIRING: Screw terminals permit fast IN/OUT
WIRING: Screw terminals for convenient MOUNTING: To indoor box TA-BBSF field wiring. TA434-4N5 98005 4" 120VAC 0.065 81-95 Red
IN/OUT wiring. Low current draw for or outdoor box TA-WBBF, see accessories
minimizing power supply and wiring cost. page 13*. HOUSING: Steel gong and cast aluminum. See TA434-6N5 97521 6 120VAC 0.065 81-95 Red
page 138 for dimensional drawings.
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85. TA434-10N5 96522 10 120VAC 0.065 84-98 Red
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.

TORK ALERT
A DIVISION OF NSi INDUSTRIES, LLC
TORK 127 USA 800.321.5847 www.nsiindustries.com TORK 128
LIGHT DUTY AND WEATHERPROOF DIMENSIONS
FRONT VIEW

GENERAL PURPOSE MOTOR DRIVEN


BELLS & BUZZER SIREN
8-1/4"

Power
wires
2 feet
6-7/8"
long (2) 9/32"
mounting
holes

APPLICATIONS APPLICATIONS Mount siren (hardware not included)

15-3/8"
FRONT VIEW
Designed to operate on either bell For industrial and outdoor 7-1/2" dia.

ringing transformers or batteries. TA740 use. Ideal for evacuation and (2) nuts,

Non-adjustable sound.
loosen to

TA725 warning systems. adjust siren


direction.

8-1/4"
1/2" conduit 8-1/2" dia.

ORDERING INFO FEATURES


connector

FEATURES Power
wires
1/2" conduit (not furnished)
2 feet Siren power wires
CATALOG UPC SWITCH VAC VDC AMPS dB long
6-7/8"
(2) 9/32"
NO. CODE mounting Junction box &
ALARM: Bell ringing, non-adjustable sound. INPUT VOLTAGE: 120AC & DC, 60Hz. holes
(2) wire nuts (not furnished)

DIMENSIONS FOR TA725: TA740 96228 212 Gong 8-16 3-6 1 76 @ 10' ALARM: Loud, distinctive tone. Designed
3" H x 212" W x 1" D. to be effective over standard horns or bells. ORDERING INFO
TA744 96230 4" Gong 8-16 3-6 1 78 @ 10'
MOUNTING: Fully enclosed sturdy steel bases HOUSING: Red enamel paint over heavy CATALOG UPC INPUT dB
and covers. Base and cover snap together, no NO. CODE VOLTAGE @10 FEET AMPS VA
TA725 96226 Buzzer 8-16 3-6 1 88 @ 3' gauge aluminum housing. Fully enclosed
screws required. motor. 180 swivel and adjustable
TA315-1N5 96599 120VAC/DC 117 2.5 300
direction.

CHIMES & MANUAL FIRE


CHIME KITS ALARM
PULL-DOWN STATION

APPLICATIONS APPLICATIONS

Powerful and loud, pleasant sounding Designed for indoor use.


push-button chimes. Ideal for homes, Ideal for schools, hospitals,
apartments and offices. industrial plants, warehouses
and retail stores. Key
ORDERING INFO required to close and reset
FEATURES CATALOG UPC device. Meets requirements,
DESCRIPTION DIMENSIONS
NO. CODE BSA, MEA, CA and UL.
INPUT: 16V, 10VA, 120VAC. 16VAC Chime + Push Button
TAC212WS 96064 clip for Stucco + 10VA 7316L x 4W x 2D
ALARM: Chime. Transformer FEATURES
16VAC Chime + ORDERING INFO
MOUNTING: Fully enclosed sturdy steel bases. TAC212WL 96054 2 Push-buttons + 714L x 434W x 212D ALARM: Loud, distinctive tone. Designed to be
10VA Transformer CATALOG UPC
compatible with any control panel to initiate local NO. CODE SWITCH VOLTS AMPS
TAC210W 96052 16VAC Chime 714L x 434W x 212D alarm signals, trip municipal fire alarm box and start
fire pumps. TA270A 96521 SPST, NO 30V AC/DC 1

MOUNTING: Sturdy metal construction, mounts to


a standard single gang electrical box.

TORK ALERT
A DIVISION OF NSi INDUSTRIES, LLC
TORK 129 USA 800.321.5847 www.nsiindustries.com TORK 130
TELEPHONE TELEPHONE
STROBE RELAY

APPLICATIONS APPLICATIONS
For single-line analog phone This device activates appliances
lines. Emits a high intesity when a telephone ring voltage is
flashing light when the telephone detected. For indoor and outdoor
rings. Ideal for alerting the use with horns, bells or strobes.
hearing impaired, high ambient Recommended use where
noise environments and quiet ambient noise levels are high.
zones. ADA compliant. ORDERING INFO FCC approved.
ORDERING INFO
FEATURES CATALOG UPC INPUT TELEPHONE POWER RINGER PEAK
NO. CODE RING VOLTAGE EQUIVALENCE CANDLEPOWER FEATURES CATALOG UPC INPUT TELEPHONE AC INPUT RINGER PEAK
NO. CODE RING VOLTAGE VOLTAGE EQUIVALENCE CANDLEPOWER
PLUG: TA-B-KHD-120VAC 97101 45-130V, 20-30Hz 120VAC 0.4 70,000
INPUT: Accepts RJ-11C phone plug. 115VAC-5A, Up to
RJ-11C connection. TA-B-8332 97100 39-150V/20-30Hz 230VAC-2A 115VDC-500MA 0.6
TA-B-KHD-120VAC, includes 120VAC TA-B-KHD-1000-PP 97102 50-130V, 20-30Hz Analog line 1.5 8,000 WIRING: Hard wire connections,
power cord. ring voltage
for analog phone lines.
MOUNTING: Easily mounts to interior MOUNTING: Weatherproof, indoor and
surfaces, for indoor use. outdoor, includes mounting bracket.

TELEPHONE WALL CLOCKS


HORN QUARTZ & ELECTRIC ORDERING INFO
QUARTZ CLOCK
CATALOG UPC TYPE SIZE FRAME
NO. CODE COLOR

APPLICATIONS TA1886 G 96156 QUARTZ 8 Grey


APPLICATIONS
TA1886 B 96155 QUARTZ 8 Brown
High quality compact signaling Each model meets United States
device. For indoor use. Easily Government Specifications. All TA1887 G 96159 QUARTZ 12 Grey
connects to phone systems and Clocks provide second hand for
enables locations with moderate accurate timing. TA1887 B 96157 QUARTZ 12 Brown
to high ambient noise to have
a loud telephone alert. FCC ORDERING INFO TA1887 BK 96158 QUARTZ 12 Black
FEATURES
approved.
CATALOG UPC INPUT TELEPHONE dB RINGER ELECTRIC CLOCK
NO. CODE RING VOLTAGE @3 FEET EQUIVALENCE QUARTZ
FEATURES Accurate to one minute per year. Low power CATALOG UPC TYPE SIZE FRAME
TA-B-KHS-1000-PP 97103 50-130V, 20-30Hz 90 0.8 NO. CODE COLOR
consumption for long battery life.
ALARM: Adjustable tone and volume. Uses AA battery (not supplied). TA1880 G 96152 ELECTRIC 8 Grey
PLUG: RJ-11C modular connection. ELECTRIC
TA1880 B 96151 ELECTRIC 8 Brown
MOUNTING: Grey enclosure. For indoor use, surface 110VAC, 60 Hz synchronous motor. 66 inch line
mountable. cord and plug. Does not require grounding.
TA1882 G 96154 ELECTRIC 12 Grey
MOUNTING: Concealed mounting brackets allow
for simple, neat placement on walls. TA1882 B 96153 ELECTRIC 12 Brown

TORK ALERT
A DIVISION OF NSi INDUSTRIES, LLC
TORK 131 USA 800.321.5847 www.nsiindustries.com TORK 132
ELECTRIC DOOR PUSH-BUTTONS DIMENSIONS

OPENERS ILLUMINATED, TA1786B Only


REMOTE CONTROL NON-ILLUMINATED & 1 3/8"
(34mm)
1 3/16"
(30mm)

& CONTACT DEVICES WEATHERPROOF


2-3/8" DIA.

1-13/16"
BETWEEN
CL

2 13/32" 2 13/32"
(61mm) (61mm)

APPLICATIONS APPLICATIONS MOUNTING HOLES


ON MODEL TA1786B and TA1786CB
MODEL TA1786CB MODEL TA1786B

For unlocking or locking metal or For outdoor use to activate low


wooden doors using low voltage MORTISE TYPE REMOTE OPENER voltage bells, buzzers, horns or any
wiring. For AC, use TA591 or Reversible for right or left hand door. Use with mortise entrance locks having a latch other audible signal. Ideal for factory
TA592 transformer. bolt with up to 12" width and throw. Dimensional drawings available on page 138. doors, receiving departments, small
office buildings, limited access retail
CATALOG UPC
DEVICE NO. CODE VOLTS AMPS stores and private homes. WEATHERPROOF PUSH-BUTTONS / SOLID CAST BRASS
BUTTON CATALOG UPC DESCRIPTION INPUT
MAGNETIC SWITCH CONTACTS NO. CODE VOLTAGE
For activating a variety of signals, ideal for limiting space applications. Self-insulating and can be
8-16VAC .95-1.75 Without conduit Momentary Contacts
mounted in any direction. All units include companion magnet. Dimensions: 2316L x 12W x 12D TA09 96960 3-6VDC 1.25-1.80 TA1786B 96090 backplate 4 amps AC/DC @ 12V
DEVICE CATALOG UPC DESCRIPTION VOLTS AMPS 4 amps AC, 2 amps DC @ 24V
NO. CODE MAX. With conduit 2 amps AC
TA1786CB 96091 1 amp DC @48V
backplate
Circuit closed with
TA60 96975 magnet engaged
Make & break 24VAC 16VAC .95-1.75
TA61 96976 .5 TA154 96962
NO and NC 12VDC 3-6VDC 1.25-1.80
Circuit open with ILLUMINATED PUSH-BUTTONS, UP TO 16VAC NON-ILLUMINATED PUSH-BUTTONS, UP TO 24VAC
TA62 96977 magnet engaged
CATALOG UPC BUTTON CATALOG UPC COLOR SIZE
BUTTON NO. CODE COLOR SIZE NO. CODE

DOOR/WINDOW CONTACTS, ROLLING BALL TYPE RIM TYPE REMOTE OPENER TA600 96041 Polished 214
Signals automatically with the opening and closing of doors, windows and transoms. Operates from Reversible for right or left hand door. Standard surface type used with lock latches with 134" Brass (diameter)
pressure in any direction. Non-tilt, non-jamming design. Fits 34" hole; no need to mortise. up to 58" width and throw. 6" wire leads. Dimensional drawings available on page 138. TA603L 96035 Gold (diameter)
TA603 96044 Polished 134
Brass (diameter)
DEVICE CATALOG UPC DESCRIPTION VOLTS AMPS DEVICE CATALOG UPC VOLTS
NO. CODE MAX. NO. CODE TA631 96088 White 234 x 78"
Normally closed
TA44 96995 TA635 96047 Ivory, black bar 234 x 78"
Push to open TA631L 96089 White 234 x 78"
Normally open 12-24V TA666BK 96048 Black, ivory bar 234 x 234
TA45 96996 2 TA152 96961 8-16VAC, 3-6VDC
Push to close AC/DC
Momentary contact
TA46 96997 Push to make & break
1516 TA602 96043 Polished Brass 138 x 514
TA656B 96039 Gold x 234
ELECTRIC DOOR SWITCH DOOR TRIP SWITCH
For turning lights/signals on or off when doors are opened or closed. Ideal for closets, dark rooms, Signals automatically as door is openend. Commonly used on store doors to announce
storage areas of walk-in refrigeration. Rust resistant steel case with 4 knockouts, antique brass plate. entrance of customers. Mounts on top of door frame. Solid cast brass. Size: 3 x 158
Box dimensions: 114"W x 3 78"H x 2D. Plate dimensions: 114W
CATALOG UPC AMPS CATALOG UPC AMPS TA601 96042 Sprayed Brass 2 x 2916
DEVICE NO. CODE DESCRIPTION VOLTS MAX.
DEVICE NO. CODE VOLTS MAX. TA215LB 96031 Brass 114 x 2

Light ON when 125VAC 6 58


TA502 96964 door is open 250VAC 3 58" TA620* 96045 Chrome
TA620L* 96037 Chrome (diameter)
TA236 96963 12-24VAC 2 (diameter)
58
Light OFF when 125VAC 6 58"
TA620B* 96046 Brass
TA503 96965 TA620LB* 96038 Brass (diameter)
door is open 250VAC 3 (diameter)
*Stainless steel plate to fit TA620 models: Order TA 147-1

TORK ALERT
A DIVISION OF NSi INDUSTRIES, LLC
TORK 133 USA 800.321.5847 www.nsiindustries.com TORK 134
WARNING LIGHTS WARNING LIGHTS
ORDERING INFO ORDERING INFO
INDUSTRIAL UNITS VEHICULAR UNITS
COLOR LETTER TO COLOR LETTER TO
REPLACE "*" REPLACE "*"
Red R Red R
Amber A Amber A
Clear C
Blue B
APPLICATIONS APPLICATIONS
12"conduit mounting. Full 12"conduit mounting. Full
selection of dome colors, selection of dome colors,
see "Ordering Info". For see "Ordering Info". For
outdoor use. All units must be outdoor use. All units must be
mounted vertically with base mounted vertically with base
at bottom. at bottom.

TA47*N5 / TA47*R5 ALL PURPOSE 360 BEACON TA52*N5 COMPACT ROTATING BEACON
Large parabolic reflector rotates around a 100 wall bulb. Long range beam. Use to indicate Light intensifying reflector rotates arounf a low current 25 watt bulb. Bayonet socket for TA53*E1 ROTATING BEACON TA54*E1 PORTABLE, MAGNETIC, ROTATING BEACON
equipment malfunctions, security intrusion, etc. easy lamp replacement. Ideal for restricted or dangerous areas. Single point shock-mounting. Ideal for use on security or service vehicles. Single point shock-mounting. Ideal for use on security or service vehicles.

DEVICE CATALOG UPC DESCRIPTION VOLTS AMPS CATALOG UPC CATALOG UPC CATALOG UPC
NO. CODE DEVICE NO. CODE DESCRIPTION VOLTS AMPS DEVICE NO. CODE DESCRIPTION VOLTS DEVICE NO. CODE DESCRIPTION VOLTS

90 FPM 75 FPM, 12 watt lamp


TA47RN5 96061 117VAC TA52RN5 96063 80-90 FPM TA53RE1 96083 TA54AE1 96187 Quiet belt-drive motor. 12VDC
Corrosion resistant/Outdoor use 12VDC
Glass filled polypropylene housing 360 rotation 90-100 FPM Teardrop design fits under windshields.
Acrylic dome Dependable belt & turntable design TA53AE1 96183 Dependable belt & turntable design Includes glare shield, velcro tape
TA47AN5 96161 117VAC .9 TA52AN5 96163 Acrylic dome 117VAC .21 25 watt lamp TA54RE1 96087
Tamper resistant dome clamps 412H x 712 diameter
Nominal current draw Nominal current draw Acrylic Dome
240VAC, TA53AF1 96185 Nominal current draw 36VDC
TA47AR5 96162 912"H x 812 diameter 60Hz TA52BN5 96263 612H x 558 diameter
712H x 6 diameter
TA53AG1 96184 24VDC
TA371L*N5 ROTATING SEALED TWIN BEAMS
TA93-2*N5 MIDI-STROBE Heavy Duty, double sealed beam, revolving light with 30 watt lamps. Each 35,000 CP bulb
Solid state circuitry in a low profile design. No moving parts means less Maintenance! provides long range visibility. TA131D*N5 / TA131D*U1 DOUBLE FLASH SUPER STROBE TA879 VEHICULAR BACKUP ALARM
Ideal for industrial applications requiring extremely high visibility. One model Solid state electronic unit. Helps to comply with OSHA and State regulations. Makes
CATALOG UPC DEVICE CATALOG UPC DESCRIPTION VOLTS AMPS
DEVICE NO. CODE DESCRIPTION VOLTS AMPS NO. CODE covers all popular mounting methods: 12" pipe, surface, flange, electrical box. distinctive noise, ideal for extreme variations in background noise

80-90 FPM CATALOG UPC DEVICE CATALOG UPC DESCRIPTION VOLTS


TA93-2RN5 99622 TA371LRN5 96500 117 VAC .8 DEVICE NO. CODE DESCRIPTION VOLTS AMPS NO. CODE
70-80 FPM Lexan dome
Solid state electronic circuitry Quiet belt drive motor
TA93-2AN5 97623 High output 3-4 watt, 3.6 joules Anodized aluminum housing with polished TA131DRN5 96510 2 sound levels
Vertically mounted flash tube aluminum, non-tarnishing base 120VAC .2 97 or 87 dB +/- dB at 4ft 12 to
Snap out socket base for 117VAC .04 Snap lock retaining ring 60 FPM, 7.5 JPF TA879 96102
TA131DAN5 96610 High intensity 85,000 peak CP Multi-voltage 48VDC
TA93-2CN5 96968 360 Fresnel dome optics for quick & economical changeout Water-resistant housing
Flashtube Rated at 7000-8000 hrs.
Nominal current draw 912H x 8 12 diameter Durable Lexan housing
6 12H x 5 18 diameter TA131DRU1 96511
TA93-2BN5 97624 5H x 714 diameter 10.5-
31.0VDC
TA131DAU1 97611
TA94*N5 ELECTRONIC STROBE
High intensity strobe tube with inner fluted lens for maximum brilliance. No moving parts makes
it immune to shock and vibration. Ideal for security alert.

DEVICE CATALOG UPC DESCRIPTION VOLTS AMPS


NO. CODE

TA94RN5 97626 70-80 FPM


Solid state electronic circuitry High
output 3-4 watt, 3.6 joules
TA94AN5 97627 Acrylic dome 117VAC .04
Glass filled polypropylene housing
Suitable for outdoor use NOTE: "FPM" = Flashes per minute
TA94BN5 97628 912H x 812 diameter "JPF" = Joules per flash

For replacement parts and accessories, see page 138.

TORK ALERT
A DIVISION OF NSi INDUSTRIES, LLC
TORK 135 USA 800.321.5847 www.nsiindustries.com TORK 136
POWER SUPPLY ACCESSORIES, DIMENSIONS
UNITS REPLACEMENT REMOTE CONTROL DOOR OPENERS
24 VDC UNITS
PARTS 9/16"
3-5/16" WIRE

& DIMENSIONS TA152


LEADS

2-1/8" CL 1-3/8"

TA640 No. 6 MOUNTING


LETTER TO 1-3/16" 1/2" SCREWS (3)
COLOR
APPLICATIONS TA606
REPLACE "*"
Red R
Amber A < Full selection of dome colors. 11/16"
9/16" 1/16"
1/8"
Units provide power to Clear
Blue
C
B
To designate color, place desired 1/16"
multiple signaling devices Green G letter in place of " * " 2-3/4"
11/32"
White W
depending on requirements.
3/8"
ORDERING INFO
CL 3/4"
ORDERING INFO
FEATURES UNIT CATALOG UPC DESCRIPTION
CATALOG UPC INPUT OUTPUT OUTPUT RIPPLE NO. CODE
NO. CODE VOLTAGE VOLTAGE CURRENT REGULATION VOLTAGE 1-9/16"

TA606 TA131D TA-D8A 96971 Acrylic Dome Amber


TA09 5/8" 1"

Regulated and filtered 24VDC up to 600mA. Easy to TA606 96109 117VAC 24VDC 600mA 3/32"
1-3/4"
TA53 TA-M1 96138 12VDC Motor
use screw terminals, accepts #16-24AWG. No conduit is TA53, TA54 TA-B1 96114 Small Drive Belts
1-3/8"

TA640 96110 115VAC 24VDC 4A +/-5% 10mVRMS


required for installation. 3-5/8"

TA53, TA54 TA-B2 96115 Large Drive Belts 5-3/8"

TA640 TA371L TA-B3 96116 Drive Belts CL

Dual output unit, each providing 2 Amps fo current. If 5-7/8"


TA53, TA54 TA-L3 96129 12VDC Bulb
connected in parallel, will provide up to 4Amps. Circuit
NO. 8 FLAT HEAD

15/16"
WOOD SCREW 1-1/4" 1/4"

breaker provides input protection. TA53 TA-L4 96130 24VDC Bulb


WIRING DIAGRAMS
15/16"
1/2"

TA93-2 TA-L6-2 96982 110VAC Xenon Flash Tube 5/8"


1/8" 7/32"
3/32"
1-1/4" 7/16"

TA52 TA-L8 96134 110VAC Bulb


TA47 TA-L9 96135 110VAC Bulb
TRANSFORMERS TA94 TA-L10 96136 110VAC Xenon Flash Tube CL

TA-94 TA-L10-1 96981 110VAC Xenon Flash Tube TA154 2-7/8"

TA371L TA-L12 97625 110VAC Bulb 1-13/16"

TA502 TA502-BX 96967 Backbox 3" 3-1/2" 1-9/16" CL


WIRE
LEADS
TA502 TA502SW 96966 Replacement switch No. 6 FLAT HEAD
WOOD SCREW
TA503 TA503SW 96969 Replacement switcH 11/16"
3/32"
APPLICATIONS TA874 Series TA-BBSF 97694 Backbox 4" painted Dawn Mist
1-3/8"
5/8"

ORDERING INFO Weatherproof Backbox .5" KOs 15/16"


TA874 Series TA-WBBF 97692 4" painted Dawn Mist 27/32" 23/32"
Engineered to ensure long 3/16" 7/16"

use on bells, buzzers and CATALOG UPC TYPE VOLTS-AMPS PRIMARY SECONDARY Hz TA-BBSF, TA-WBBF TA-SFPF 97707 Semi-Flush plate Dawn Mist
NO. CODE (VA) VOLTAGE VOLTAGE
chimes. TA-BBSF, TA-WBBF TA-SFPFR 97697 Semi-Flush plate Red HEAVY DUTY BELLS
TA590 96104 Bell 5 120 10 60 TA47, TA94 TA-ADR 96111 Acrylic Dome Red
6
TA47, TA94 TA-ADA 96311 Acrylic Dome Amber
TA591 96105 Chime 10 120 16 60
TA47, TA94 TA-ADB 96411 Acrylic Dome Blue 10" DIA.

10
TA592 96106 Tri-Volt 10-10-20 120 8-16-24 50/60 TA52, TA53 TA-D5B 96419 Acrylic Dome Blue 6"

4-1/16" 3-3/8"

TA54 TA-D6R 96120 Dome Red 3-3/8"

TA598 96602 Tri-Volt 20-30-30 120 8-16-24 60


10" DIA.
4-1/16"

TA54 TA-D6A 96320 Dome Amber 3-3/8"


6" 3-1/4"
3-3/8" 3-1/4" 4-1/16" .173 DIA. CSK 80 TO 82

TA599 96108 Heavy Duty 40 120 24 60 TA54 TA-D6C 96422 Dome Clear 4-1/16" .173 DIA. CSK 80 TO 82 4-1/16" 3-3/8" TO 11/32" DIA. 4 PLACES

3-3/8" TO 11/32" DIA. 4 PLACES

TA93, TA94 TA-D7R 96121 Fresnal Dome Red 4-1/16" 4 .173 DIA. CSK 80 TO 82

TA1245Y-50 96166 Heavy Duty 50VA 120/208/240 24 60


3-3/8" TO 11/32" DIA. 4 PLACES
3-1/4"

TA93, TA94 TA-D7A 96321 Fresnal Dome Amber 10" DIA. 3-3/8" 3-1/4"
3-3/8"4-1/16"
.173 DIA. CSK 80 TO 82
TO 11/32" DIA. 4 PLACES
4-1/16" .173 DIA. CSK 80 TO 82

TA93, TA94 TA-D7C 96621 Fresnal Dome Clear 6" 11/32" DIA. 4 PLACES
TO

TA1245Y-75 96167 Heavy Duty 75VA 120/208/240 24 60 4-1/16" 3-3/8" 3-3/8"


4 1/16

TA93, TA94 TA-D7B 96421 Fresnal Dome Blue


3-3/8"
4-1/16"

4-1/16"
TA131D TA-D8R 96970 Acrylic Dome Red 3-3/8" 3-1/4"
2-7/8"
3-3/8" 3-1/4" 4-1/16" .173 DIA. CSK 80 TO 82
TO 11/32" DIA. 4 PLACES
4-1/16" .173 DIA. CSK 80 TO 82
TO 11/32" DIA. 4 PLACES

TORK ALERT
A DIVISION OF NSi INDUSTRIES, LLC
TORK 137 USA 800.321.5847 www.nsiindustries.com TORK 138
POOL&SPA CONTROLS
PP PANEL SERIES
POOL AND SPA PANELS
WITH TIME SWTICHES

APPLICATIONS
LISTED
POOL/SPA
CONTROL PANEL
3NZM
Pumps
Swimming pools
Fountains
PP-100R-P4 PP-125R-P4-100X
Ponds PP-125R-P4
PP-20R-P4

PP-20R-2P4 ORDERING INFO

CATALOG UPC CONTROL CONTROL ADDITIONAL


CONTROL #1 CONTROL #2
PP-10R-M-GFCI NO. CODE INPUT INPUT INFORMATION

FEATURES Mechanical
PP-10R-M-GFCI 53010 24 hour timer 120VAC N/A Rated for 15A, 12HP @ 120VAC
Digital
PP-10R-E-GFCI 53011 7 day timer 120VAC N/A Rated for 15A, 12HP @ 120VAC
COMBINATION PANEL: The PP panel REVERSIBLE DOOR: Easy-Hinge patented
series provides a flexible platform to create a removable and reversible door. Change from Panel only. Add controls from
PP-20R 94015 N/A 120/240VAC N/A page 147 and 148.
custom pool and spa control at an off the shelf left to right opening. Solves installation issues
price. Start with a blank panel and addtimers, in the field. PP-20R-P1 53000 P1101-M 120VAC N/A
freeze controls, circuit breakers, switches and
WHILE-IN-USE COMPARTMENT: Inside PP-20R-P4 53001 P1104-M 240VAC N/A
outlets for a custom installation. Or select a
mounting for two devices with cord exit.
pre-assembled timer/panel available in many Included with control
popular combinations. DEVICE MOUNTING: Provision for PP-20R-2P1 53002 P1101-2M 120VAC 120VAC Two timers design 50A panel
#1 mechanism
PP-10R: 15 amp timed GFCI protected outlet mounting one or two devices in any Included with control
PP-20R-2P4 53003 P1104-2M 240 VAC 240VAC Two timers design 60A panel
with additional GFCI outlet. combination accepts toggle, GFCI, X-10 and #1 mechanism
PP-20R: 20 amp load center 120-240V, 1/2 UPB type devices in, PP-100R and PP-125R PP-100R 94016 N/A 120/240VAC Panel only. Add controls from
circuit breaker base. enclosures. page 147 and 148.
PP-100R: 100 amp load center 120-240V, Add another control
TRANSFORMER: Select panels include 120V PP-100R-P4 53004 P1104-M 240VAC from page 147 and 148.
5/10 circuit breaker base.
input: 100 watt with output 12V/13V or 300
PP-125R: 125 amp load center 120-240V, PP-100R-P4P1 53005 P1104-M 240VAC P1101-M 120VAC
watt with output 12V/13V/14V.
8/16 circuit breaker base.
COMPACT 2-IN-1: PP-20R-2P1 and PP-100R-2P4 53006 P1104-M 240VAC P1104-M 240VAC
CONTROLS: Freeze protection or mechanical
PP-20R-2P4 includes two timers in a compact
and digital timers are all available with unique PP-100R-P4P4FM 53009 P1104-M 240VAC P1104FM-M 240VAC Timer 2 includes
housing. Interlock switch allows second timer Fireman Switch
features not found elsewhere in the industry.
to turn ON only if first timer is in operation. Panel only. Add controls
Find specification details on pages 147 and 148. PP-125R 94017 N/A 120/240VAC from page 147 and 148.
ENCLOSURE: Metal NEMA 3R with lockable
BREAKERS: Listed for Cutler Hammer (BR), Add another control from
hasp. See page 153 for dimensions. PP-125R-P4 53007 P1104-M 240VAC page 147 and 148.
GE (THQL), Murray/Siemens (MP) and Square D
(HOM) (not included). PP-125-2P4 53008 P1104-M 240VAC P1104-M 240VAC
Includes 100 watt
PP-125R-P4-100X 94018 P1104-M 240VAC Low Voltage Transformer
NOTE: " " = Indicates freeze protection. PP-125R-P4-300X 94019 P1104-M 240VAC Includes 300 watt
Low Voltage Transformer

POOL & SPA


CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 141 USA 800.321.5847 www.nsiindustries.com TORK 142
PFP SERIES 1100 SERIES SPECIFICATIONS
POOL FREEZE PROTECTION SAME ON/OFF TIMES EACH DAY
SWIMMING POOL SWIMMING POOL INPUT VOLTAGE: 120 or 208-277VAC,
TIME SWITCHES TIME SWITCHES 60Hz (varies by model).
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE:
APPLICATIONS APPLICATIONS -40 to 165F (-40 to +74C).
POWER CONSUMPTION: 3 watt max.
Pumps Pool pumps
ENCLOSURE: Lockable hasp. Type varies
Swimming pools Heaters by model. See page 153 for dimensions and
Fountains Lighting additional enclosure information.
Ponds
FEATURES

SCHEDULING: Minimum ON setting is 20 minutes with a


minimum OFF setting of 75 minutes. Dial accommodates up to
12 pairs of trippers. One pair included.
MANUAL OVERRIDE: Until the next regularly scheduled
ON or OFF automatic operation then resumes.

FEATURES ORDERING INFO ORDERING INFO CONTACT RATINGS


CATALOG UPC CONTROL CONTROL NOTES CATALOG UPC INPUT SUPPLY OUTPUT ENCLOSURE CONTACT
NO. CODE INPUT TYPE VOLTAGE
FREEZE PROTECTION ONLY: Sensor turns on NO. CODE (VAC) 60Hz CONTACTS TYPE RATING
load when outdoor air temperature drops to user 120-277VAC
PFP2 94035 PFP2-M 240VAC Freeze protection only Metal Indoor General Purpose 40A
settable level between 33F to 42F. Moving 1101 10011 120 SPST single phase
NEMA 1
water prevents costly freeze damage. 120/240 Mechanism and 120-277VAC
PFP3 94036 PFP3-M Freeze protection only 1101-M-IAP 10052 120 SPST Resistive 40A
w/neutral mounting plate single phase
TIMERS WITH FREEZE PROTECTION: Freeze protection
Control loads with mechanical or digital timer PFP1102 94037 PFP1102-M 240VAC Metal Indoor Tungsten 120VAC 40A
with timer 1104 10014 208-277 DPST NEMA 1
with regular on and off schedule. Built-in 120/240 Freeze protection
120, 277VAC
PFP1103 94038 PFP1103-M Noryl Indoor/Outdoor Inductive 20A
temperature sensor forces load on if outdoor air w/neutral with timer 1104-N 10042 208-277 DPST NEMA 3R single phase
temperature drops to user settable level between Freeze protection Metal Indoor/Outdoor
PFPEW1102 94039 PFPEW1102-M 240VAC 1104-O 10017 208-277 DPST Pilot Duty 120-277VAC 1000VA
33F to 42F. with Digital timer NEMA 3
120/240 Freeze protection Mechanism and 120VAC 2HP
PFPEW1103 94040 PFPEW1103-M 1104-M-IAP 10051 240 DPST Motor
w/neutral with Digital timer mounting plate 240VAC 5HP
COMBINATION PANEL Freeze protection Noryl Indoor/Outdoor NEMA
PP-20R-F2 94033 PFP1102-M 240VAC 1101FM-N 10043 120 SPST
with timer 3R with fireman switch
Combination of timers, freeze protection,
breaker base, and device mountings. PFP1102-M & Timer 2 includes Noryl
Indoor/Outdoor NEMA
PP-100R-F2F4FM 94034 240VAC 1104FM-N 10044 208-277 DPST
P1104FM-M Fireman Switch 3R with fireman switch
PP-20R: 20 amp load center 120-240V, 12
circuit breaker base. PFPT 94028 120/240VAC Thermostat accessory Mechanism with fireman
1101FM-M 10043 120 SPST switch
PP-100R: 100 amp load center 120-240V, 510
Mechanism with fireman
circuit breaker base. 1104FM-M 10044 208-277 DPST switch
BEAKERS: Listed for Cutler Hammer (BR), GE 1101D 10028 120 Two 1101 Metal Indoor/Outdoor
(THQL), Murray/Siemens (MP) and Square D SPST each NEMA 3R
(HOM) (not included). Two 1104 Metal Indoor/Outdoor
1104D 10029 208-277 DPST each NEMA 3R
WHILE-IN-USE COMPARTMENT: Inside One 1104 Metal Indoor/Outdoor NEMA
1104DF 10032 208-277
mounting for two devices with cord exit. One 1104FM 3R
Order #P47 for a pair of ON/OFF trippers
DEVICE MOUNTING: Provision for mounting Replacement Trippers Order #PF48 for a pair of ON/OFF trippers for 1100FM series
one or two devices in any combination accepts
toggle, GFCI, X-10 and UPB type devices. Replacement Motor #101 (120V) & #201 (208-277V)
NOTE: " " = Indicates Freeze Protection.

POOL & SPA


CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 143 USA 800.321.5847 www.nsiindustries.com TORK 144
DW200B TIMER SPECIFICATIONS CONTACT RATINGS
TWO SPEED PUMP CONTROL CONTACT
TYPE VOLTAGE
TIME SWITCH TIMING ACCURACY: Line Frequency. RATING
NO NC
INPUT VOLTAGE:
120/208-240/277VAC, 50/60Hz. General Purpose 24-277VAC 30A 30A

TERMINAL RANGE: #12 - #16AWG. 120VAC 30A 10A


Ballast
277VAC 20A 10A
OPERATING TEMPERATURE:
Tungsten 120-277VAC 15A 2A
APPLICATIONS -40F to 158F (-40C to +70C).
POWER CONSUMPTION: 5VA max. Pilot Duty 120-277VAC 720VA 720VA

Two speed pumps ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R 120VAC 1HP 1HP
Motor Load
208-277VAC 2HP 2HP
SVRS device is standard with lockable hasp. See page 153 for
enclosure dimensions and accessories. Resistive 28VDC 30A 30A

CH 1 CH 2
SPDT SPDT
WIRING DIAGRAMS
SPDT
DWZ100B SERIES DW200B SERIES
CH 1 CH 2
SPDT SPDT
FEATURES ORDERING INFO TIMER SUPPLY SPDT
C NO NC TIMER SUPPLY C NO NC C NO NC
DWZ100B SERIES DW200B SERIES
CATALOG UPC TIMER SUPPLY NO. OF DRY CONTACTS
NO. CODE (VAC) 60Hz CHANNELS (UNPOWERED)
TWO CHANNEL: Two programmable contacts TIMER SUPPLY
N 120 208-240 277
C NO NC TIMER SUPPLY
N 120
C
208-240 277
NO NC C NO NC
for independent control of pool equipment and DW200B 82190 120/208-240/277VAC 2 SPDT L
120V 120V
SVR or coordinated control for two speed pumps. LOAD L L
N N 120 208-240 277
DW200B-0 82231 120/208-240/277VAC 2 SPDT 120 208-240 277
208-240V 208-240V LOAD LOAD
SCHEDULING: 99 ON & OFF set points allow L N
120V 120V
individual programs for each day of the week at 277V LOAD 277V L L N N
a minimum 1 minute apart. 208-240V N 208-240V
AC LINE INPUT
LOAD LOAD
AC LINE INPUT
SELECT277V
PROPER TERMINALS SELECT PROPER TERMINALSN N
HOLIDAYS: 1 to 24 individual dates for 277V
AND APPLY ONLY ONE VOLTAGE
AND APPLY ONLY ONE VOLTAGE
preprogrammed longer run times for heavy use AC LINE INPUT AC LINE INPUT
times. SELECT PROPER TERMINALS SELECT PROPER TERMINALS
AND APPLY ONLY ONE VOLTAGE AND APPLY ONLY ONE VOLTAGE
DAYLIGHT SAVING: Automatic adjustment
(can be omitted) for year-round pools.
TWO SPEED PUMP WIRING
MANUAL OVERRIDE: Until the next regularly
scheduled ON or OFF, automatic operation then TWO SPEED PUMP WIRING
resumes.
CLOCK FORMAT: AM/PM or Military time
POWER OUTAGE BACKUP: Permanent
schedule retention when timer is powered
down at the end of the season. Super capacitor
provides 7 days of real time backup.

POOL & SPA


CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 145 USA 800.321.5847 www.nsiindustries.com TORK 146
P1100 SERIES QUICK INSTALL/RELEASE LEVER: For easy installation P1100 SERIES QUICK INSTALL/RELEASE LEVER: For easy installation
and removal when installing into pool panels.
SWIMMING POOL TIMERS, 24 HOUR and removal when installing into pool panels. SWIMMING POOL TIMERS, 7 DAY
ELECTROMECHANICAL LOAD INDICATOR LAMP DIGITAL CONTROL LOAD INDICATOR LAMP
CONTROL CONVENIENT EXTERNAL ROCKER SWITCH: 3 position LARGE LCD DISPLAY
switch: OFF/ON/AUTO. Use switch to turn OFF pump at the LARGE "MANUAL" BUTTON: 3 operating modes
end of pool season. available: OFF/ON/AUTO. Using the OFF mode, the pool can
REAL TIME SWITCH FACE: Easy to set and check time. be closed down without disrupting the time settings.

CAPTIVE TRIPPERS: 15 minute intervals, no lost trippers. POWER OUTAGE BACKUP: Battery retains time and
schedule.
HEATER CONTACTS: FM suffix includes "Fireman Switch"
to turn off pool heater 20-30 minutes before timer turns OFF. 7 DAY PROGRAMMING ONE MINUTE INTERVAL:
Contact rates SPST, 15A @120V. Allows for the control of various electrical equipment on a 7
day schedule. 15 schedule weekly programs.
THERMOSTAT: PFP models include built in Freeze
Protection. No extra wiring. Thermostat turns on load at THERMOSTAT: PFPEW models include built in Freeze
user settable level between 33F and 42F. Moving water Protection. No extra wiring. Thermostat turns on load at
prevents costly freeze damage. user settable level between 33F and 42F. Moving water
prevents costly freeze damage.
ACCESSORY CONTACT: PF models include extra contact to
accept PFPT Freeze Protection Accessory. Thermostat turns ON ACCESSORY CONTACT: PFEW models include extra
load at user settable level between 33F adn 42F. Moving contact to accept PFPT Freeze Protection Accessory.
water prevents costly freeze damage. Thermostat turns ON load at user settable level between 33F
ORDERING INFO and 42F. Moving water prevents costly freeze damage.
TIMER INTERLOCK: Makes one second timer dependant
on operation of another timer. CATALOG UPC INPUT SUPPLY RESISTIVE/ TIMER INTERLOCK: Makes one timer dependant on
CODE (VAC) 60Hz CONTACTS INDUCTIVE HP RATING NOTES operation of another timer.
NO. RATINGS
PEW101-M 82432 120 DPST 40A 3 HP @ 120
ORDERING INFO
Accepts PFPT
RESISTIVE/ PFEW101-M 94029 120 DPST 40A 3 HP @ 120
CATALOG UPC INPUT SUPPLY thermostat input
CODE (VAC) 60Hz CONTACTS INDUCTIVE HP RATING NOTES
NO. RATINGS
7.5HP @ 240V Freeze protection
PFPEW1102-M 94031 240 DPST 40A
Thermostat included NOTE: " " = Indicates Freeze Protection.
PFP2-M 94026 240 DPST 40A 7.5HP @ 240V only 120/240 3 HP @ 120V Freeze protection
PFPEW1103-M 94032 DPST 40A
120/240 3 HP @ 120V Thermostat w/neutral 7.5HP @ 240V included
PFP3-M 94027 DPST 40A
w/neutral 7.5HP @ 240V only
PEW104-M 82442 240 DPST 40A 7.5HP @ 240V
P1101-M 10056 120 DPST 40A 3 HP @ 120V
Accepts PFPT
PFEW104-M 94030 240 DPST 40A 7.5HP @ 240V thermostat
Fireman input
P1101FM-M 10060 120 DPST 40A 3 HP @ 120V Switch
Accepts PFPT
PF1101-M 94020 120 DPST 40A 3 HP @ 120V thermostat input
WIRING DIAGRAMS
POOL & SPA
Fireman Switch & Accepts
PF1101FM-M 94024 120 DPST 40A 3 HP @ 120V PFPT thermostat input
PFP1102-M 94022 240 DPST 40A 7.5HP @ 240V Freeze Protection
included JUNCTION BOXES
120/240 3 HP @ 120V Freeze Protection
PFP1103-M 94023 DPST 40A included A B C
w/neutral 7.5HP @ 240V
P1104-M 10057 240 DPST 40A 7.5HP @ 240V
Fireman
P1104FM-M 10061 240 DPST 40A 7.5HP @ 240V Switch APPLICATIONS
Accepts PFPT
PF1104-M 94021 240 DPST 40A 7.5HP @ 240V ORDERING INFO
thermostat input For installation of underwater pool
PF1104FM-M 94025 240 DPST 40A 7.5HP @ 240V Fireman Switch & Accepts lights or low voltage connections. CATALOG UPC NPF CONDUIT HUB PIPE INPUT
PFPT thermostat input Solid brass with grounded post and NO. CODE A/B/C SIZE
Replacement for 3 ground terminals for use with
P1101-2M 10058 120 DPST 40A 2HP @ 120V PP-20R-2P1 PB-50 94041 12" / 12" / 12" 12"
metallic or PVC conduit.
Replacement for
P1104-2M 10059 240 DPST 40A 5HP @ 240V PP-20R-2P4 PB-75 94042 34" / 34" / 34" .34"
NOTE: " " = Indicates Freeze Protection.
34"
PB-100 94043 / 1"/ 34" 34" & 1"

POOL & SPA


CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC
TORK 147 USA 800.321.5847 www.nsiindustries.com TORK 148
SR-500 & SR-500PS NEW!

SAFETY VACUUM
RELEASE SYSTEMS 2
1

Of all the protections you can put


between your family and the risk of
APPLICATIONS entrapment, the best protection is

AT THE SOURCE.
A Safety Vacuum Release System (SVRS)
works by monitoring the vacuum on the
suction side of the pool or spa pump. When a Make Your Pool & Spa Safer, Update your
LAYERS OF PROTECTION
blockage occurs in the main drain or skimmer,
a sudden rise in vacuum will cause the SR-500
and SR-500PS to shut down and activate an
audible alarm. The pump will remain off with
the alarm sounding until manually reset. 1 DOOR ALARMS OUTSIDE
Door alarms on doors leading to the pool or spa area THE POOL AREA
Commercial & Residential help to alert parents or staff to anyone entering the
Swimming pools and spas pool from the house or building. Keep children from
Fountains
Ponds
Remote alarms linked to the Safety Vacuum Release
System (SVRS) alert parents or attendants when the accessing the pool
Any pump size ORDERING INFO SVRS is activated, indicating that someone in the pool
may need help.
or spa when
FEATURES CATALOG
NO.
UPC
CODE
INPUT SUPPLY DRY CONTACTS
(VAC) 60Hz (UNPOWERED) unattended
2
FENCE & GATE
EMERGENCY STOP
PROTECTION: POWER OUTAGE BACKUP: Insures SR-500 95425 120/240 DPST
Restrict access to a pool or spa by surrounding the 3
Provides an important layer of protection, settings and reading will be saved, 30 minute area with fencing that is equipt with a self-closing,
reducing entrapment risk. rapid recharge. SR-500PS 95426 120/240 DPST An emergency STOP button allows parents or attendants in the
self-latching gate closure. Utilize gate latches that
Turns off pump in milliseconds upon detecting area to immediately and easily shut down the pump system in
MAINTENANCE OVERRIDE: 30 minute are adjustable, magnetically operated as well as key
sudden vacuum change. the event of entrapment.
maintenance override - (for pool or spa lockable.
Vacuum monitored 128 times per second, service). CONTACT RATINGS
rapid response and accurate readings.
Power monitored 50/60 times per second,
BUILT-IN DIAGNOSTICS: Displays TYPE VOLTAGE CONTACT
RATING
INSIDE 4
SVRS
insures continuous power detection.
error codes, prevents guessing during
troubleshooting. 120VAC
THE POOL AREA The SVRS automatically shuts down the vacuum pump when
sensing a rise in vacuum pressure in some cases, reacting to
Newest state-of-art NEC microprocessor General Purpose 20A
technology-- guaranteed reliability and EASY RETROFIT: Integrates with common
existing timer box Trouble free installation, no
240VAC
120VAC
Minimize the potential entrapment conditions in LESS THAN ONE SECOND!
performance. Motor 3HP Audible alarms linked to the SVRS alert those nearby to a
WARNING ALARM: Multiple audible alarm
pipes to cut or glue. 240VAC
risk of entrapment potential entrapment.
capabilities allows for quicker alert to harmful
situations.
COMPLIANCE: ASME/ANSI 112.19.17 as
required by the International Building Codes
injuries or drowning SVRS should meet or exceed ASME/ANSI A112.19.17 standards
in order to comply with IRC and IBC codes.
(IBC) and the International residential Codes
AUXILARY CONTACTS: Accessible extra dry (IRC). Meets all current codes and standards
contact auxiliary equipment can be added. for
3
5 DRAIN COVERS
EQUIPMENT PROTECTION: Low vacuum SVRSs on new and existing pools and spas. Minimize potential entrapments or Differential Hold Down
sensing - (prevents cavitations or running the ENCLOSURE: Plastic Indoor/Outdoor NEMA 4 Forces, thereby minimizing the potential for a swimmer to
pump dry, eliminating costly equipment failure). 3R with lockable hasp. See page 153 for be entrapped.
SCHEDULING: Programmable 24 hour timer, dimensions and additional information. Anti-entrapment drain covers should meet or exceed ASME
or as stand-alone SVRS working in conjunction and ANSI A112.19.8 2007 and 2007 Federal Pool & Spa
with existing pool controller. 5 Safety Act and have a Certified Safe Flow Rating. Many
compliant drain covers are easily retrofitted to existing drains.

POOL & SPA ALL ITEMS AVAILABLE FROM NSi/TORK!


CONTROLS More details available in our Safety Products catalog and Layers of
A DIVISION OF NSi INDUSTRIES, LLC
Protection brochure, ask your sales representative for more information.
TORK 149 USA 800.321.5847 www.nsiindustries.com
ANTI-ENTRAPMENT SELF-LATCHING
DRAIN COVERS NEW!
GATE CLOSURES NEW!

& SELF-CLOSING
GATE HINGES
640-475XV

TCA1-MK2
DS360M TCHD1ARP-MK2

AV20X20 & AV26X26


FEATURES
FEATURES DS12X12P
MAGNALATCH GATE CLOSURES ORDERING INFO
DS360M DRAINSAFE MagnaLatch quality latches are self-latching with
Designed for use with suction outlet sumps up permanent magnets which never lose power, for MLTPS2BGA CATALOG UPC FENCE PACKAGING
NO. CODE DESCRIPTION
to 8" in size, will retrofit smaller 5 sumps using DS12X12H safer, child-resistant security for your swimming MATERIAL AVAILABLE
additional knockouts. pool gate. The Top Pull model can be mounted so
Certified Safe flow of 123 GPM. ORDERING INFO MLTPS2BGA 95439 MagnaLatch Top Pull Gate Latch Wholesale
the release knob reaches the minimum code height,
ASME/ANSI A112.19.8 2007 Standard Compliant. CATALOG UPC SURFACE AREA RETROFIT typically 54", on a shorter gate. It's adjustable for MagnaLatch Top Pull Gate Latch, 2" Gap
DESCRIPTION MLTPRP 95445 Retail
NO. CODE (SQ.IN) FRAME when the gate gets out of alignment. The Vertical Spacer included
DS12X12P DRAINSAFE
Designed to retrofit Pentair style frames, and Drainsafe Anti-Entrapment Pull model is designed for gates and fences that MLVPS2BGA 95440 MagnaLatch Vertical Pull Gate Latch Wholesale
DS360M 95431 27 N/A
Type Suction Outlet Cover are 60 or more in height.
functions on dual drain as well as single suction MagnaLatch Vertical Pull Gate Latch, 2"
Drainsafe 12 x 12" Anti-Entrapment MLVPRP 95444 Retail
outlets. DS12X12P 95429 53 Pentair TRUCLOSE GATE HINGES Gap Spacer included
Type Suction Outlet Cover
Certified Safe flow of 250 GPM @ 1.5 FPS. TruClose hinges are designed so the residential
Drainsafe 12 x 12" Anti-Entrapment MLS2RPAKA 95446 Round Post Adapter Kit Wholesale
ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12H 95430 53 Hayward homeowner can quickly and easily adjust tension to
Type Suction Outlet Cover
DS12X12H DRAINSAFE Waterway 18 x 18" support a 375lbs gate load and self-closes up to a MLSPACER 95447 MagnaLatch Gap Spacer Retail
640-475XV 95432 159.6 18 x 18
Designed to retrofit Hayward style frames, and Anti-Entrapment Drain Cover 55lb gate, for the ultimate safety around pools and
REGULAR DUTY MODELS
functions on dual drain as well as single suction AV20X20 95433
Eureka 20 x 20"
73.6
12 x 12 other areas requiring self-closing gates. Hinges
Anti-Entrapment Drain Cover (9 x 9 minimum) are rust-free and are self-lubricating. Regular duty TCA1RP-MK2 98018 TruClose Regular Range Gate Hinge Metal Retail
outlets.
Eureka 26 x 26" 18 x 18 and heavy duty models available.
Certified Safe flow of 250 GPM @ 1.5 FPS. AV26X26 95434
Anti-Entrapment Drain Cover
108.9
(12 x 12 minimum) TCA1-MK2 98026 TruClose Regular Range Gate Hinge Metal Wholesale
ASME/ANSI A112.19.8 2007 Standard Compliant.
640-475XV WATERWAY TCA3RP-MK2 98019 TruClose Regular Range Gate Hinge Vinyl, Wood Retail
Designed for single and multiple drain use, the POOL & SPA SAFETY TCA3-MK2 98027 TruClose Regular Range Gate Hinge Vinyl, Wood Wholesale
640-475XV works on dual drain as well as single
suction outlets. ACCESSORIES TCAMA2RND 98024
TruClose Regular Range Gate Hinge,
Round frames Wholesale
Minimizes Differential Hold Down Forces of adjustable gap
dual drain systems. HEAVY DUTY MODELS
Certified Safe flow rate of 540 GPM @ 1.09 FPS. TCHD1ARP-MK2 98020 TruClose Heavy Duty Metal Retail
AV20X20 & AV26X26 EUREKA
Eureka drain covers unique grating system is TCHD1AL2-MK2 98021 TruClose Heavy Duty, with 2 legs Metal Wholesale
designed for new construction and retrofit, to add
TCHD2RP-MK2 98022 TruClose Heavy Duty Vinyl, Wood Retail
protection from entrapment.
ASME/ANSI A112.19.8 2007 Standard Compliant. TCHD2L2-MK2 98023 TruClose Heavy Duty, with 2 legs Vinyl, Wood Wholesale
Certified Safe flow rate of 223 GPM (20x20),
DS-MR SAFETY ACCESSORIES
495 GPM (26x26). SR-RA
SR-RA 95437 Remote Alarm

SR-ESB 95438 Emergency Stop Button

Drainsafe Masonry Anchor Kit - for


DS-AA 95435
SR-ESB DS360M
DS-AA DS-MR 95436 Drainsafe Mud Rings, Universal Fit

POOL & SPA ALL ITEMS AVAILABLE FROM NSi/TORK!


CONTROLS More details available in our Safety Products catalog and Layers of
A DIVISION OF NSi INDUSTRIES, LLC
Protection brochure, ask your sales representative for more information.
TORK 151 USA 800.321.5847 www.nsiindustries.com TORK 152
ENCLOSURES ENCLOSURES

STANDARD METAL INDOOR NEMA 1 STANDARD METAL INDOOR/OUTDOOR NEMA 3 STANDARD METAL INDOOR NEMA 1 MECHANISM & ELC71 & ELC72 SERIES
MODELS TRP400
FOR MODELS ENCLOSURE #68229 FOR MODELS MODEL #9006 FOR MODELS ENCLOSURE #63016-1 MOUNTING BRACKET #62153-1 TRP 400 (GROUP OF 4) TRP 800 (GROUP OF 8) ENCLOSURE
1101 7120 TZ220L-0 TZ300L-0 TZ220L TW220L Use Bracket #64039 TRP400 9/32"
ELC71PC/120
9/32"
1102 7122 TZ300L-0 T920L-0 TZ300L TW300L W100 W120 7-5/8" TRP402 MOUNTING HOLES ELC71PC/208-240
MOUNTING HOLES
3-5/8 "
1103 8001 T930L-0 W300 T920L W200 W220 3-1/2" ELC71PC/277
2-1/2"
1104 8004 W302 T930L W202 W222 3-1/16" ELC72PC/120
1101FM 8061 W300L TW222L Use Bracket #62153-1 11-1/2" ELC72PC/208-240
W300 W302 12" ELC72PC/277
1104FM 8121 W302L TW302L
18"
7100 8301 #62158 "E" DOOR
7102 8601 T920L-E T930L-E MECHANISM MECHANISM MECHANISM 4" 10"
ONLY WITH BRACKET WITH BRACKET
7200 8602 TW220L-E #62153-1 #64039
7202 TU40-Y
12" 4" ELC74
1101-7 EW201-Y TRP800
TRP 400 (GROUP OF 4) TRP 800 (GROUP OF 8)
ENCLOSURE
EW130B-Y EW120B-Y
9/32" TRP800 ELC74
STANDARD METAL INDOOR NEMA 1 STANDARD NORYL & LEXAN IAP BRACKET
MOUNTING HOLES 9/32"

DLC400BP STANDARD TRP800 MOUNTING HOLES

FOR MODELS ENCLOSURE #63100 FOR MODELS INDOOR/OUTDOOR DG SERIES MECHANISM ONLY
INTERMATIC ADAPTER PLATE
MECHANISM & BRACKET
FOR MODELS BRACKET

DLC400BP NEMA 3R MODEL #9000NC 4-9/16 " 2-3/32 " 4-9/16 " 3-5/8 "

7220 1847AZL LDS-A DLC400BP 1101NC DGLC100A-NC 1101-M-IAP 7200


12"
7222 8007 LDSH-A 12-1/4"
1103NC DGLC200A-NC 1104-M-IAP 7202 18"
6-5/8 " 6-5/8 "

7200L 8007L 1104NC 1102 7120


4" 10"
7202L 8007V 8001-NC 1103 7122
7120L 8150 14-1/4" 7100 E Series TERMINAL BLOCK TERMINAL BLOCK
3-1/16 " 12" 4"
1847A 8150U 7102 EW Series 1-15/16 "

DZS, DTS, MECHANISM ONLY MECHANISM & BRACKET


1848A 8007U EWZ SeriesDZM, DW,
GROUND
4-9/16 " CLEARANCE HOLE 4-9/16 "
ELC78 & ELC712
1849A 8007VL DWZ SCREW FOR GROUND SCREW
MODELS BRACKET
5401 ENCLOSURE
1847AZ 8008 70100 3-3/8"
SERIES
5441 and 5440 REMOTE CONTACTORS
ENCLOSURE
1847AL 8008L 6-5/8 " 5441
6-5/8 " 1/4" 8-3/4" 4-3/16" ELC78
MOUNTING

9000P ELC712
HOLE
1/2" or 3/4" KO

3/4" or 1" KO

STANDARD NORYL INDOOR/OUTDOOR STANDARD METAL INDOOR NEMA 1 PLASTIC INDOOR/OUTDOOR


FOR MODELS ENCLOSURE #70100 MODELS EWZ SERIES 14-1/8"

FOR MODELS NEMA 3R MODEL #9000N NEMA 3R #9000P


7-5/8" 12-3/4"
3-1/2"
TERMINAL BLOCK TERMINAL BLOCK
2-1/2" 3-1/16 "
DG SERIES MECHANISM ONLY MECHANISM & BRACKET
DG SERIES MECHANISM ONLY MECHANISM & BRACKET 1-15/16 "
7200Z, ZL 1101-N W100 W220L 7-5/8" TU40 DTU40 5-1/16"
BRACKET
EWZ101-MB BRACKET 11-1/2"

4-9/16 " 2-3/32 " 4-9/16 " 3-5/8 " 4-9/16 " 2-3/32 " E, EWZ, EH 4-9/16MECHANISM
" & BRACKET
3-5/8 " SMC-3D MECHANISM & BRACKET
7202Z, ZL 1102-N W200 W222L E101PB EWZ103-MB SERIES 3-3/8" WIRING COMPARTMENT
MECHANISM WITH MOUNTING 10-1/8"

7120Z, ZL 1103-N W202 1847AW E Series EWZ120-MB


ONLY BRACKET

STINGL
#64039

3/4" or 1" KO
7-5/8"

7122Z, ZL 1104-N W120 1847AWL 11-7/8" EW Series 6-5/8 " 6-5/8 " 6-5/8 "
EWZ201-MB 6-5/8 " 3-5/8 "

8-5/16" 3-1/16"
1/2" or 3/4" KO

Note: Indoor Enclosure Only


DG Series DZS Series W220 EWZ Series 11-1/2"

4-11/16" 4"
8001-N DTS Series W222
8001U-N DW Series STINGL SVRS EWJT & E500T SERIES
MODELS
TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK WITH MOUNTING

9000PC
BRACKET
3-1/16 " 3-1/16 " MECHANISM

ENCLOSURE ENCLOSURE
#62153-1
ONLY
1-15/16 " 1-15/16 "

SMC-3D DWZ Series DZS, DTS, 3-1/16"


MECHANISM ONLY DZS, DTS,
MECHANISM & BRACKET MECHANISM ONLY
ADAPTER
MECHANISM & BRACKET
3-1/4" DZM, DW, DZM, DW, PLATE
DZM Series 4-9/16 " 4-9/16 " 4-9/16 " 4-9/16 " SR-500 5-1/2" EJWT
DWZ DWZ BRACKET BRACKET
3.4000"

SERIES SERIES SR-500PS E500T


LC200M MECHANISM & BRACKET LDS MECHANISM & BRACKET
STANDARD METAL INDOOR NEMA 1 STANDARD METAL DUPLEX INDOOR/OUTDOOR PLASTIC INDOOR/OUTDOOR MECHANISM & MOUNTING E501T
FOR MODELS ENCLOSURE FOR W400 SERIES MODELS MODELS 4-17/32 "
LDSH 7 1/2 7 1/ 11 11

FOR MODELS NEMA 3 MODEL #9004L NEMA 3R WITH CLEAR WINDOW


3-9/32 " 3-13/32 " 1-13/16 " 2

BRACKET #65446
6-5/8 " 6-5/8 " 6-5/8 " 6-5/8 "
9-3/8"
2-1/8 "
E502T
PP-100R
W400A 1101D 1101DF EW103B-C EW120B-C 5-1/16" 1101-M 1102-M 3-1/2" MECHANISMS/BRACKETS
PP-20RPP-20R
PP-20R-P1
PP-100R
PP-100R-P4
4-9/16" #64039/62153-1/65447
PP-20R-P1 PP-100R-P4
PP20R-P4 PP-100R-P1P4
PP-100R-P1P4
W402A 1114D 1114DF 1103-M 1104-M 5-13/16 " 5-37/64 "
PP20R-P4
PP-20R-2P1
PP-20R-2P1 PP-100R-2P4
PP-100R-2P4
TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK
PP-20R-2P4
PP-20R-2P4 PP-100R-P4P4FM
PP-100R-P4P4FM
W400AL 1104D 1104DF
3-1/16 " 3-1/16 " 13 3/8 13 3/ 17 3/4 17 3/
1-15/16 "
7000 Series
1-15/16 "
1847A, Z 8 4

NEMA 1 ENCLOSUREE, EWZ, EH MECHANISM & BRACKET


8-5/16"
SMC-3D E, EWZ,
MECHANISM & BRACKET EH MECHANISM & BRACKET 1848A SMC-3D
8001-LC/WB MECHANISM & BRACKET 3-3/4"
SERIES 3-3/8" SERIES 7-1/2" 3-3/8" SHOWN WITH
STANDARD FOR MODELS 8601 8121
SNAP TRACK

DTWH40 8602 8061


8301 POOL PANEL SERIES 4 1/4 4 1/ 4 5/8 4 5/
4 8

3-1/16" 4-11/16" 4"


MECHANISM
4-11/16"
MECHANISM
4"

ONLY WITH BRACKET


12 3/4 12 3/ 6 1/8 6 1/
7 1/2 7 1/2 11 11 4 8

METAL INDOOR/OUTDOOR
STANDARD STANDARD METAL INDOOR/OUTDOOR NEMA 3 LC200M MOUNTING LDS SERIES MOUNTING
NEMA 3 MODELS MODELS PP-125R PP-10R-M-GFCI
PP-10R-M-GFCI
FOR MODELS FOR MODELS MODEL 9000B SUFFIX "O" WITH BRACKET 3.4000"
WITH BRACKET
3.4000"
PP-20R PP-20R PP-100R PP-100R PP-125R
PP-10R-E-GRCI
MODEL 9000A SUFFIX "0" PP-20R-P1 PP-20R-P1 PP-100R-P4 PP-100R-P4 PP-125R-P4
PP-125R-P4 PP-10R-E-GRCI
PP20R-P4 PP20R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-125R-2P4
PP-125R-2P4
LC200M MECHANISM & BRACKET LDS LC200M
MECHANISM & BRACKET MECHANISM & BRACKET LDS MECHANISM & BRACKET PP-20R-2P1 PP-20R-2P1 PP-100R-2P4 PP-100R-2P4 PP-125R-P4-100X
PP-125R-P4-100X
7300, L, Z, ZL 8001-0 1101-O 1104-O LC200M LDS LDSH PP-20R-2P4 PP-20R-2P4 PP-100R-P4P4FMPP-100R-P4P4FM PP-125R-P4-300X
PP-125R-P4-300X
4-17/32 " 3-9/32 "
LDSH 3-13/32 " 1-13/16 " 4-17/32 " 3-9/32 "
LDSH 3-13/32 " 1-13/16 "
13 3/8 13 3/8 17 3/
4 17 3/ 4
20 3/4 20 3/
4
9 3/4 9 3/
4

7302, L, Z, ZL 8001U-0 1102-0 7200-O 2-1/8 " 2-1/8 "

8007U-0 8007-0 1103-0 7202-O


DZS100BP-0 DZS200BP-0
5-13/16 " 5-37/64 " 5-13/16 " 5-37/64 "
DZS200BP DW200B-0
DZM200BP-0 5401 4 1/4 4 1/4 4 5/8 4 5/8 4 5/8 4 5/
8
4 1/2 4 1/
2

SHOWN WITH SHOWN WITH


SNAP TRACK SNAP TRACK

12 3/4 12 3/4 6 1/8 6 1/8

TORK 153 TORK 154


PP-125R PP-125R PP-10R-M-GFCI PP-10R-M-GFCI
ALPHANUMERIC INDEX ALPHANUMERIC INDEX

1101 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144 2104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 652A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS100BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 654A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
1101D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 2115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 655D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP-12 . . . . . . . . . . . . . . . . . . . . . . . 65
1101FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144 2116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 701A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 8007L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP-24 . . . . . . . . . . . . . . . . . . . . . . . 65
1101FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144 2117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 701AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 8007-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS200BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 711A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 8007U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D1060LA . . . . . . . . . . . . . . . . . . . . . . . . . . 104 DZS400BP . . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144 2224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8007U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D1060M . . . . . . . . . . . . . . . . . . . . . . . . . . 104 DZS400BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8007V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D1060MW . . . . . . . . . . . . . . . . . . . . . . . . . 104 E101B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1101-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8007VL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D212H . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 E101PB . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1101-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D212HA . . . . . . . . . . . . . . . . . . . . . . . . . . 104 E103B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8008L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D212HW . . . . . . . . . . . . . . . . . . . . . . . . . . 104 E120B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 7120ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E201B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 401A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E500T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1102-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7122ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG180A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 E501T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 403A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 8601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DG200A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E502T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 405A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7200L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 90058-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 DG280A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EJWT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 422A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 7200-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DG280A-24 . . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1103-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 454D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7200Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A502HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGLC100A-NC . . . . . . . . . . . . . . . . . . . . . . . 79 ELC71PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73
1103-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 455D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7200ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A502HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGLC200A-NC . . . . . . . . . . . . . . . . . . . . . . . 79 ELC71PC/208-240 . . . . . . . . . . . . . . . . . . . 73
1104 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144 457Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGM100A . . . . . . . . . . . . . . . . . . . . . . . . . . 63 ELC71PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73
1104D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 460D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7202L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A506HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGM100A-Y . . . . . . . . . . . . . . . . . . . . . . . . 63 ELC72PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73
1104DF . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 5001M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7202-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A506HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGS100A . . . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC72PC/208-240 . . . . . . . . . . . . . . . . . . . 73
1104FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144 5004M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7202Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGS100A-12 . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC72PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73
1104FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144 5007M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7202ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGS100A-24 . . . . . . . . . . . . . . . . . . . . . . . . 85 ELC74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5008M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A512HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGU100A-Y . . . . . . . . . . . . . . . . . . . . . . . . . 79 ELC78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1104-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144 5021M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A512HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGUM100A . . . . . . . . . . . . . . . . . . . . . . . . . 79 ELS-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
1104-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 5024M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DGUM100A-Y . . . . . . . . . . . . . . . . . . . . . . . 79 EPC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
1104-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5026M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DIN100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EPC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
1104-O . . . . . . . . . . . . . . . . . . . . . . . . 31, 144 5231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DIN200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
1847A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5237 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A515MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . 81 EPC-LC . . . . . . . . . . . . . . . . . . . . . . . . . . 73, 75
1847AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 7300Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A515MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS12X12H . . . . . . . . . . . . . . . . . . . . . . . . 151 EW101B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AW . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7300ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS12X12P . . . . . . . . . . . . . . . . . . . . . . . . . 151 EW103B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AWL . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A530MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS360M . . . . . . . . . . . . . . . . . . . . . . . . . . 151 EW103B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5404-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 A530MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS-AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 EW103B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AZL . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7302Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A530MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DS-MR . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 EW120B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1848A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 7302ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 A530MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTS100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 EW120B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 73866 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 A560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTS200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 EW120B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5500-OC . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 A560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTS400B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 EW201B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5737TM . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 806B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 A560MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 EW201B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5737TZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 806D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 A560MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105 DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 EWZ101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 601A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 AV20X20 . . . . . . . . . . . . . . . . . . . . . . . . . 151 DW200B . . . . . . . . . . . . . . . . . . . . . . . . . . 145 EWZ101-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2005A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 602A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001-LC/WB . . . . . . . . . . . . . . . . . . . . . . . . 37 AV26X26 . . . . . . . . . . . . . . . . . . . . . . . . . . 151 DW200B-O . . . . . . . . . . . . . . . . . . . . . . . . 145 EWZ103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2007A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 611A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 8001-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C412H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 EWZ103-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2008A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 611D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8001-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C460M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DWZ100B . . . . . . . . . . . . . . . . . . . . . . . . . . 69 EWZ120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 621D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8001-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZM200BP . . . . . . . . . . . . . . . . . . . . . . . . . 71 EWZ120-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 631D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 8001U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZM200BP-O . . . . . . . . . . . . . . . . . . . . . . . 71 EWZ201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 640-475XV . . . . . . . . . . . . . . . . . . . . . . . . 151 8001U-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 DZS100BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65 EWZ201-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
TORK 155 TORK 156
ALPHANUMERIC INDEX ALPHANUMERIC INDEX
HPS30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 PFP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 T920L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA93-2RN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD1ARP-MK2 . . . . . . . . . . . . . . . . . . . . . 152
LC200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 PFP2-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147 T920L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA503SW . . . . . . . . . . . . . . . . . . . . . . . . . 138 TA94AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD2L2-MK2 . . . . . . . . . . . . . . . . . . . . . . 152
LC200M . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 PFP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 T920L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA52AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA94BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD2RP-MK2 . . . . . . . . . . . . . . . . . . . . . . 152
LCS115M . . . . . . . . . . . . . . . . . . . . . . . 75, 112 PFP3-M . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 T930L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA52BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA94RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TRP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1102 . . . . . . . . . . . . . . . . . . . . . . . 143 T930L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA52RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA-ADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDS-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1102-M . . . . . . . . . . . . . . . . . . . . . . 148 T930L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TA53AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-ADB . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1103 . . . . . . . . . . . . . . . . . . . . . . . 143 TA09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA53AF1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-ADR . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDSH-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PFPEW1103-M . . . . . . . . . . . . . . . . . . . . . . 148 TA1245Y-50 . . . . . . . . . . . . . . . . . . . . . . . 137 TA53AG . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MLS2RPAKA . . . . . . . . . . . . . . . . . . . . . . . . 152 PFPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 TA1245Y-75 . . . . . . . . . . . . . . . . . . . . . . . 137 TA53RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP802 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MLSPACER . . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TA131DAN5 . . . . . . . . . . . . . . . . . . . . . . . 136 TA54AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TRP-U . . . . . . . . . . . . . . . . . . . . . 79, 112, 116
MLTPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-2P4 . . . . . . . . . . . . . . . . . . . . . . 141 TA131DAU . . . . . . . . . . . . . . . . . . . . . . . . 136 TA54RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TA-B-8332 . . . . . . . . . . . . . . . . . . . . . . . . . 132 TU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MLTPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-F2F4FM . . . . . . . . . . . . . . . . . . . . 143 TA131DRN5 . . . . . . . . . . . . . . . . . . . . . . . 136 TA5508H-G1 . . . . . . . . . . . . . . . . . . . . . . . 127 TA-BBSF . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TU40-Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MLVPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA131DRU1 . . . . . . . . . . . . . . . . . . . . . . . 136 TA590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-B-KHD-1000-PP . . . . . . . . . . . . . . . . . . 131 TW-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
MLVPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152 PP-100R-P4P1 . . . . . . . . . . . . . . . . . . . . . . 141 TA152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA591 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-B-KHD-120VAC . . . . . . . . . . . . . . . . . . 131 TW-220L-E . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC10U . . . . . . . . . . . . . . . . . . . . . . . . . . 114 PP-100R-P4P4FM . . . . . . . . . . . . . . . . . . . 141 TA154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA592 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-B-KHS-1000-PP . . . . . . . . . . . . . . . . . . 131 TW-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . 112 PP-10R-E-GFCI . . . . . . . . . . . . . . . . . . . . . . 141 TA1786B . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA598 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TAC210W . . . . . . . . . . . . . . . . . . . . . . . . . 129 TW-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . 111 PP-10R-M-GFCI . . . . . . . . . . . . . . . . . . . . . 141 TA1786CB . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TAC212WL . . . . . . . . . . . . . . . . . . . . . . . . 129 TW-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC20U . . . . . . . . . . . . . . . . . . . . . . . . . . 114 PP-125-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1880 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TAC212WS . . . . . . . . . . . . . . . . . . . . . . . . . 129 TZ-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 PP-125R . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TA1880 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D5B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ220L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSC5U . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 PP-125R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1882 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D6A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSCS20UP . . . . . . . . . . . . . . . . . . . . . . . . . 113 PP-125R-P4-100X . . . . . . . . . . . . . . . . . . . 141 TA1882 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D6C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9P-120 . . . . . . . . . . . . . . . . . . . . . . . 110 PP-125R-P4-300X . . . . . . . . . . . . . . . . . . . 141 TA1886 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA603L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D6R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-300L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9P-277 . . . . . . . . . . . . . . . . . . . . . . . 110 PP-20R . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TA1886 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-D7A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 TZ-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9PD . . . . . . . . . . . . . . . . . . . . . . . . . 110 PP-20R-2P1 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1887 B . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA-D7B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 USB-MMP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
OSWS9PDM . . . . . . . . . . . . . . . . . . . . . . . . 110 PP-20R-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141 TA1887 BK . . . . . . . . . . . . . . . . . . . . . . . . 132 TA62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA-D7C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147 PP-20R-F2 . . . . . . . . . . . . . . . . . . . . . . . . . 143 TA1887 G . . . . . . . . . . . . . . . . . . . . . . . . . 132 TA620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D7R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 PP-20R-P1 . . . . . . . . . . . . . . . . . . . . . . . . 141 TA215LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA620B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D8A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147 PP-20R-P4 . . . . . . . . . . . . . . . . . . . . . . . . 141 TA236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA620L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-D8R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147 SMC3D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 TA270A . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 TA620LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 SR-500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 TA315-1N5 . . . . . . . . . . . . . . . . . . . . . . . . 130 TA631L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L10-1 . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104FM-M 240VAC . . . . . . . . . . . . . . . . . 143 SR-500PS . . . . . . . . . . . . . . . . . . . . . . . . . 149 TA340-10G5 . . . . . . . . . . . . . . . . . . . . . . . 128 TA635 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L12 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147 SR-ESB . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 TA340-4G5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 TA-L3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 SR-RA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 TA340-4N5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA656B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 SS13B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA340-6G5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA666BK . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TA-L6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 SS13F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA340-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 TA-L8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W300-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PEW101-M . . . . . . . . . . . . . . . . . . . . . . . . 148 SS20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA371LRN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TA740 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 TA-L9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PEW104-M . . . . . . . . . . . . . . . . . . . . . . . . 148 SS20F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 TA434-10N5 . . . . . . . . . . . . . . . . . . . . . . . 128 TA744 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 TA-M1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 SS700Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA434-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA874-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TA-MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 W400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1101-M . . . . . . . . . . . . . . . . . . . . . . . . . 147 SS700ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA874-N5R . . . . . . . . . . . . . . . . . . . . . . . . 127 TA-SFPF . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W400AL . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147 SS720A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 TA45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA875-1G1 . . . . . . . . . . . . . . . . . . . . . . . . 128 TA-SFPFR . . . . . . . . . . . . . . . . . . . . . . . . . . 138 W402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1104-M . . . . . . . . . . . . . . . . . . . . . . . . . 147 SS720AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 TA46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA875-G1 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TA-WBBF . . . . . . . . . . . . . . . . . . . . . . . . . . 138
PFEW101-M . . . . . . . . . . . . . . . . . . . . . . . 148 SS721Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA47AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA876-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TCA1-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152
PFEW104-M . . . . . . . . . . . . . . . . . . . . . . . 148 SS721ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TA47AR5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA879 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TCA1RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1102 . . . . . . . . . . . . . . . . . . . . . . . . . . 143 SSA100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 TA47RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135 TA880-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127 TCA3-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1102-M . . . . . . . . . . . . . . . . . . . . . . . . 147 SSA100R-24 . . . . . . . . . . . . . . . . . . . . . . . 102 TA502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 TA93-2AN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCA3RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1103 . . . . . . . . . . . . . . . . . . . . . . . . . . 143 SSA200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 TA502-BX . . . . . . . . . . . . . . . . . . . . . . . . . 138 TA93-2BN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCAMA2RND . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1103-M . . . . . . . . . . . . . . . . . . . . . . . . 147 SSA200R-24 . . . . . . . . . . . . . . . . . . . . . . . 102 TA502SW . . . . . . . . . . . . . . . . . . . . . . . . . 138 TA93-2CN5 . . . . . . . . . . . . . . . . . . . . . . . . 135 TCHD1AL2-MK2 . . . . . . . . . . . . . . . . . . . . . 152
TORK 157 TORK 158
NOTES

TERMSOFSALE ADDRESS
TORK VENDORNUMBER: 662381 9730 Northcross Center Court
1. Prices are F.O.B. our plant. Huntersville, North Carolina
2. Prices do not include any sales tax. 28078 USA
3. Freight charges will be prepaid on all orders $100.00
and over shipping within continental USA using standard PHONE
shipping methods and service. office 800.321.5847
4. Minimum order $100.00. technical support 888.500.4598
5. Claims for shortage, erroneous charges or price corrections
shall be deemed waived unless made in writing, delivered
to NSi within 30 days of invoice. FAX
6. Terms of payment 2% 10th prox. net 25th following. 800.841.5566
7. Warranties We strive to produce the highest quality
products on the market today. NSi guarantees all products
to be free of defects in material and workmanship for
a period of 90 days from date of sale. Any claims for EMAIL
defective material must be agreed to in writing by NSi.
nsi@nsiindustries.com
Defective material will be replaced on an F.O.B., our
factory basis. NSi disclaims the implied warranty of fitness
for a particular application.
WEB
OTHER PRODUCTS AVAILABLE www.nsiindustries.com
NSi can provide many other products for special applications
which are not listed in this catalog. If you require an item which
you do not find listed, please contact us. We would be pleased
to provide a quotation upon receipt of a drawing or a sample.

GUARANTEE
It is our goal to provide extraordinary
products and services on a daily basis. If our
products or service do not meet with your
satisfaction, please let us know immediately
and we promise to make every reasonable
effort to remedy the situation.

Das könnte Ihnen auch gefallen