Beruflich Dokumente
Kultur Dokumente
AxonGroupLtda
Making Big Things
PBX: (+57)(1) 7 55 99 00
Email: ventas@axongroup.com.co
Web Site: www.axongroup.com.co
Support: support@axongroup.com.co
IKELOS 20160901AT6111UG1S
CONTENTS
1 CONTROL DE CAMBIOS....................................................................................................... 5
2 OVERVIEW.......................................................................................................................... 6
3 VERSIN V1.1 ..................................................................................................................... 7
4 INSTALLATION .................................................................................................................... 8
4.1 REQUISITOS PARA LA INSTALACIN DEL SOFTWARE ........................................................ 8
4.2 INSTALACIN DE COMPONENTES.................................................................................... 8
4.2.1 MICROSOFT .NET FRAMEWORK 4.5SP2 .................................................................. 8
4.2.2 MICROSOFT VISUAL C++ 2013 COMPONENT .......................................................... 9
4.2.3 WinpCap Installation ........................................................................................... 10
4.3 AXON TEST IEC61850 INSTALLATION ............................................................................. 11
5 FUNCTIONAL COMPONENTE ............................................................................................ 14
5.1 WORK AREA ................................................................................................................. 14
5.2 MENU BAR ...................................................................................................................... 15
5.3 FILE MENU .................................................................................................................... 16
5.4 MENU TOOLS................................................................................................................... 17
5.5 ABOUT MENU .................................................................................................................. 17
5.6 ICONS BAR ...................................................................................................................... 18
5.7 IEDS TAB ....................................................................................................................... 19
5.8 PROPERTIES TAB .............................................................................................................. 19
5.9 DATA OBJECTS TAB ....................................................................................................... 20
5.10 POLLING TAB............................................................................................................ 20
5.11 DATA MONITOR TAB ..................................................................................................... 21
5.12 MESSAGE TAB .......................................................................................................... 21
6 FUNCTIONALITY & CONFIGURATION ................................................................................ 22
6.1 LOAD CONFIGURATION................................................................................................. 22
FIGURE INDEX
1 CONTROL DE CAMBIOS
2 OVERVIEW
AT61 is a software for simulation and analysis of IEC 61850 standard, IEC 61850
is a part of the International Electrotechnical Commission's (IEC) Technical Committee
57 (TC57) for vendor-agnostic engineering of the configuration of Intelligent Electronic
Devices (IED) for electrical substation automation systems to be able to communicate
with each other. This tool allows you to upload the CID, ICD, SCD or get the settings
directly from the IEC 61850 server, also allows sending commands, activation of general
polling, reports, etc.
This manual provides advantage in the use of AT61, speeding up test for analysis
and simulation, making them more specific, easier and faster.
To the culminate the manual is expected that reach a great domain of the software
and know fully the features, both them tools, as well as them modules, so that can develop
their projects of way versatile, with great ease and success.
Welcome!
3 VERSIN V1.1
Load IED settings through SCL (Substation Configuration Language) format files.
Validate SCL files syntax, in according with edition 1 or edition 2 rules.
Make dynamic discovery for IED capability.
Export to SCL (cid,icd,scd) file IED data model.
Visualize data model of hierarchical structure, including both report as data sets.
Execute read query for data model.
Make write operations on data model.
Enable or disable reports (Unbuffered and Buffered).
Setup recurrent query (polling) to objects of data model
Export in format cvs the values of data reports
Commands Execute (Direct-Operate, Select-Before-Operate, with or without
enhanced security).
Access to the functions of transfer files Protocol MMS.
4 INSTALLATION
Software:
- Windows 7 SP1 or Higher.
- Framework: Microsoft .NET 4.5 SP2
- Component: Visual C++ 2013
Hardware:
- 200 MB free Hard Disk space
- 1.5 GHz or Higher Processor Speed
- 1GB Memory RAM
The .NET Framework can be installed under Windows Vista, Windows 7 SP1 and
Windows 10. This feature set provides support to Axon Test so that it can be implemented
on any computer regardless of hardware platforms.
For Install the simulator, it is necessary to download latest version AT61 Software
from Axon Group WEB Site:
(http://www.axongroup.com.co/axon_descargas.php)
Please run downloaded files for begin install programs Accept the license terms
by checking I accept the license terms Press Install button.
Then a window with progress bar is shown, to indicate advance in the installation.
A window is displayed with the message "Installation is complete" Once the
installation process completes clicking Finish button for completes the process.
The process is resuming shown in Figure 2.
Microsoft Visual C++ 2013 is a software component necessary for the operation of
some libraries of Axon Test, this Visual C++ Redistributable package installs runtime
components needed to run C++ applications each of these are predefined for the General
needs of the programming of applications, among them can be installed under Windows
7SP1 and Windows 10. These feature sets provide support to Axon Test so that it can be
implemented on any computer regardless of hardware platforms.
These feature sets provide support to Axon 61850 Test so that it can be
implemented on any computer regardless of hardware platforms. This application can
be found in the installation directory of the application of AT61 C:\Program Files (x
86) \Axon Group\Axon Test 61850 in this directory the file WinPcap_4_1_3.exe is run
and follow each of the steps the wizard of WinPCap to be done in a satisfactory
manner.
Run the installation program file for begins to install the software AT61 (a
welcome screen for the installation of the application is shown Figure 4) Press Next
button (shows another screen with the terms of license Figure 5) Select I accept the
terms of the license agreement clicking Next button
Then a window will be displayed, in which you have to enter the data of the
computer or terminal user where it will be installed Axon Test Name, Company, and
Email Figure 6 Enter data and clicking Next button.
Later shows a window with the path of the folder where it will be installed the
software. However, this path can be modify clicking change button Figure 6, clicking
Next button.
Then, is display a window that you will allow the installation of the respective
access direct for different user execution, see Figure 7
The next screen allows show a summary on the features configured for Axon Test
simulator installation on the computer Figure 9, clicking Next button.
Later the installation program file begins to install the software Axon Test, once
the installation has finished, a window indicating that the installation has been successful
Figure 10. Clicking Finish button. To end the process.
5 FUNCTIONAL COMPONENTE
Axon Test IEC 61850, has a series of tools for the management of any automation
project, once accesses to the application are deployed all windows and specific
components such as:
The workspace is composed by five tabs for easy manage of information report
from a station or a device with Protocol of communication IEC61850.
Note: When application start, display a dialog box with two option, first one load a
SCL (open SCL), or second Discovery device for read its configuration from server
device, it is important remember simulator must be connected to network and know IP
address of devices.
The Menu bar have all tools necessary for interactive with application AT61.
Discovery: Lets find out the settings directly from the device server, the IP
address of the device is necessary and also shows other necessary parameters.
Recently IEDs Discovered: Access last IED recently found by Discovery option.
This option displays a dialog box with version and license type information.
On this tab, is displayed data model IEC61850 of IED loaded. Allow select a
specific IED when have been load several from a SCD file.
This tab show selected object properties, from data model tree or by data object.
Tab for drag & drop signals from data model and programming cyclic read
operations (polling) according time interval configurable, this is a second by default.
This signals are received without enable report and data monitor display them.
Enabled Trace Mode: Add signals to table, doesnt care if already exist.
Clear All: delete all signals from table.
ExportList: Save data from tab to disk, txt or rtf file type.
For show errors message or important information such, device connection, SCL
information, etc.
This section shows the Simulator tools, and how to use each of these.
IEC 61850 protocol allow connect to IED for read and write configuration files,
The IEC 61850 specifies the usage of Manufacturing Message Specification (MMS,ISO
9506) over TCP/IP as communication between the IEC 61850 server and client
(device/IEC 61850 OPC Server). AT61 simulator load IED configuration by open SCL
(.cid .icd .scd) file option or discovery mode, to connect with a IED and load its
configuration.
After load configuration files through open SCL option, data model is displayed in
tree view with all IED information in the configuration file. It is possible load IED
configuration file using discovery option considering IED and simulator both are
connected in same network, and can be reached each other.
AT61 allow validate configuration SCL file prior loaded, according to standard
edition version 1 or version 2, for detect possible compatibility errors. It is also allows to
export the data model of an device to SCL (.cid .icd .scd) compatible with standard
edition.
When a SCL file containing several IEDs, we can select one by one using IED tab,
shown Figure 28.
AT61 simulator connect integrates the IEC 61850 Network and devices (IEDs)
using the IEC 61850 standard Ed1 or Ed2. The data of the various IEDs on the IEC 61850
network is read by the AT61 application, facilitating the vertical communication as
defined in the IEC 61850 Ed1 & Ed2 standards. Only the MMS (Manufacturing Message
Specification) based signals on the IEC 61850 bus are read by the simulator and given to
the IED client, by select Discovery options or clicking on icon , must specific IP
address of IEC 61850 server (IED) and complete parameters in the dialog box, then
clicking aceptar button to get SCL file and show it in the data model tree.
7 IED Connection
Once IED have loaded in data model tree, can proceed to the connection with
the server 61850, clicking on the icon , with connection to server 61850 this will
pass to Online, then read and see states of the variable, enable reports, run commands,
read files, etc. For successful connection, is displayed on bottom bar, message with IP
address follow Connected word in background color green, shown Figure 30.
For connection failed, is displayed on bottom bar, message with IP address follow
failed word in background color red, shown Figure 31.
8 ENABLE REPORTS
Once the 61850 server online, for signal receive spontaneously, without configured
Properties tab show report parameters located in work area and bottom bar display
Enable or Disable according report condition, shown Figure 33.
9 CONTROL
AT61 simulator supports data objects for status, measuring, controllable status, and
controllable analog information. The IEC 61850 OPC Server supports data object types
for an IEC 61850 Device. The data objects are configured whenever they are imported
with IEC 61850 devices. The configurations can be monitored with Data Object model
tree.
AT61 allows you to run different types of commands defined by the standard IEC
61850 (Direct-Operate, Select-Before-Operate, with or without enhanced security).
Operation allows configure the Originator categories (orCat) according to test
requirement. The result of the operation is notified by adding a possible cause of failure
according to what was reported by the IED when this occurs.
Control dialog box, is setting to mode control showing operations such OPERATE
SELECT CANCEL OPERAT according command type.
10 POLLING SIGNALS
11 GENERAL INTERROGATION
This function reads the value of the signs included in the active report that
previously is selected, Figure 37, show read process for signals included in
LLN0.RP.urcb01 report, previously enable like indicated last item 8.
12 FUNCION WRITE
AT61 allows the transfer of files through the MMS (Manufacturing Message
Specification) that are available in the IED Protocol. These files may contain
configuration information or oscilografias according to the device. These read files are
displayed at the end of the data model tree, shown Figure 39.
support@axongroup.com.co