Boiler

Drum type boilers of sub-critical technology, natural circulation, single furnace, four-
corner tangential firing, single reheat, balanced draft, full steel structure, full top-support
structure and inverse U-type arrangement.

Boiler main steam flow 548.5 t/h

Superheater outlet steam pressure 17.50 MPa.a

Superheater outlet steam temperature 541

Reheat steam flow 470.6 t/h

Reheater inlet steam pressure 4.09MPa.a

Reheater outlet steam pressure 3.88 MPa.a

Reheater inlet steam temperature 334

Reheater outlet steam temperature 541

Economizer inlet feedwater temperature 281

Steam turbine type: N167 16.7/538/53


Rate output 167.08 MW

Steam pressure at the inlet of MSV 16. 7 MPa.a

Steam temperature at the inlet of MSV 538

Steam flow at the inlet of MSV 512.425 t/h

Reheat steam pressure at combined valves 3.605 MPa

Reheat steam temp. at combined valves 538

Reheat steam flow at combined valves 441.576 t/h

Exhaust steam pressure 0.00862 MPa.a

The highest cooling water temperature 39

Condenser flow 330.034 t/h

Final feed water temperature 277.8

Generator type: QFS-167-2


Rated output 167MW

Rated voltage 18 kV

Power factor 0.85 (Lagging)

Frequency 50 Hz

Speed 3000 r/min

Cooling method Water cooled