eNodeB LTE V100R008 Local Commissioning

Enable the ALD power


MOD RETPORT: CN=0, SRN=60, SN=0, PN=RET_PORT, PWRSWITCH=ON,
THRESHOLDTYPE=RET_ONLY_MULTICORE;
Scan for Antenna Line Devices
SCN ALD:;
Add Antenna Line Devices
ADD RET: DEVICENO=0, DEVICENAME="dev0",CTRLPORTCN=0,CTRLPORTSRN=60,
CTRLPORTSN=0, RETTYPE=SINGLE_RET, POLARTYPE=DUAL, SCENARIO=REGULAR;
Download RET configuration (this can be obtained from RET manufacturer)
DLD RETCFGDATA: OPMODE=SITE, IP="192.168.0.88", USR="admin", PWD="*****",
SRCF="C:/ret/ret.bin";
Calibrate the Remote Electrical Tilt
CLB RET: OPMODE=SITE;
Modify configuration according to Planning
MOD RETSUBUNIT: DEVICENO=0, SUBUNITNO=1, CONNCN1=0, CONNSRN1=60, CONNSN1=0,
CONNPN1=R0A, CONNCN2=0, CONNSRN2=60, CONNSN2=0, CONNPN2=R0B, TILT=50;
MOD RETDEVICEDATA: DEVICENO=0, SUBUNITNO=1, BEARING=80;

Confidential Information of Huawei. No Spreading Without Permission


eNodeB LTE V100R008 Local Commissioning

Enable ALD power


MOD ANTENNAPORT:
CN=0,SRN=60,SN=0,PN=R0A,PWRSWITCH=ON,FEEDERTYPE=7/8_Feeder;
MOD ANTENNAPORT:
CN=0,SRN=60,SN=0,PN=R0B,PWRSWITCH=OFF,FEEDERTYPE=7/8_Feeder;
Scan for Antenna Line Devices
Add Antenna Line Devices
Download RET configuration (this file can be obtained from RET manufacturer)
Calibrate the Remote Electrical Tilt
Modify configuration according to Planning

Confidential Information of Huawei. No Spreading Without Permission


eNodeB LTE V100R008 Local Commissioning

Enable the ALD power


MOD ANTENNAPORT:
CN=0,SRN=60,SN=0,PN=R0A,PWRSWITCH=ON,THRESHOLDTYPE=UER_SELF_DEFINE, UOTHD=40,
UCTHD=60, OOTHD=400, OCTHD=380, FEEDERTYPE=7/8_Feeder;
MOD ANTENNAPORT: CN=0,SRN=60,SN=0,PN=R0B,PWRSWITCH=OFF,FEEDERTYPE=7/8_Feeder;
Scan for Antenna Line Devices
Add Antenna Line Devices

ADD RET: DEVICENO=0, DEVICENAME="dev0",CTRLPORTCN=0,CTRLPORTSRN=60,


CTRLPORTSN=0, RETTYPE=SINGLE_RET, POLARTYPE=DUAL, SCENARIO=REGULAR;
ADD TMA: DEVICENO=10, DEVICENAME="tma0", CTRLPORTCN=0, CTRLPORTSRN=60,
CTRLPORTSN=0, SUBUNITNUM=2, CONNCN1=0, CONNSRN1=60, CONNSN1=0, CONNPN1=R0A,
CONNCN2=0, CONNSRN2=60, CONNSN2=0, CONNPN2=R0B;
Download RET configuration (this file can be obtained from RET manufacturer)

Calibrate the Remote Electrical Tilt