Product Information

PRODUCT SERIES: GENSYS

Complete power management control for


generating sets and cogeneration

THE ADVANTAGES

Combines multiple discrete components, All in One


Multi-function large graphic screen for parameters display
Multiple languages supported for information display
Enables parallel operation for up to 16 generator sets
Internal plc provides programmable logic sequencing for expanded
control and monitoring functionality
Compact module measures 10x8x2.25
Internet connection available*

Product Interface:
* Front panel display screen with keypad
* Local access by PC with internet explorer software (non-dedicated software)
* Remote access via PC modem (Internet explorer)

*future capabillity

Barber-Colman
Barber-Colman DYNA Products
P.O. Box 2940 Tel: (815) 637-3000
1354 Clifford Avenue Fax:(815) 877-0150
Loves Park, IL 61132 www.dynaproducts.com
USA
DYNA 314
FUNCTIONS INPUTS/OUTPUTS
Automatic or manual engine control. Genset three phase voltages (3 or 4 wires).
All engine parameters display. Genset three phase currents.
All genset electrical parameters display. 15 logic inputs with programmable sequences.
All utility/mains electrical parameters display. 7 logic outputs with programmable sequences.
Manual and automatic synchronization 1 magnetic pick up speed input for isochonous
(synchronizing scope available on screen). regulation.
Isochronous active load sharing control. 1 output (analog or PWM) for speed control
Iso-voltage reactive load sharing control. compatible with all electronic regulations
Power factor control when paralleling with utility. (Barber Colman, woodward, GAC, Heinzmann,
Automatic start/stop genset control according Ambac, DDEC, MDEC,).
with load. 1 analog output for voltage control compatible
Power level control (constant power or peak with most AVR (Leroy Sommer, Stanford,
shaving) when paralleling with utility. Basler,).
Temperature regulation for cogeneration.
Data circular records.* SERIAL PORTS
Events records/data logging.*
Maintenance cycle control. 1 RS232 port for PC communication + modem.
Hour run meter. 1 RS485 port with protocol Modbus RTU.
Active and reactive energy counters. 1 Bus Can port for inter Gensys communication.
Web email message on alarm detection (option). 1 Bus Can port for opencommunication with
Real time clock other modules.
Genset electrical protections:
over/under voltage
over/under frequency
over current
over neutral current
over power
over reverse power
over reactive power
over reverse reactive power
Utility/Mains electrical protection:
over/under voltage
over/under frequency
vector jump
df/dt or rate of change of frequency

WARNING
Barber-Colman requires an independent overspeed shut
down device to prevent loss of engine control which may
cause personal injury and/or equipment damage.

- NOTE -
Barber-Colman believes that all information provided herein is
correct and reliable and reserves the right to update at any time.
Barber-Colman does not assume any responsibility for its use unless
otherwise expressly undertaken.

*future capabillity

2002 Invensys plc. All Rights Reserved.


2002 Invensys plc. All Rights Reserved.
3
DYNA 314
Pickup input
Pickup +
Pickup -
-Alim
G8 G7

analog
Speed out+
-

power supply -
K3
Speed

Speed ref
regulator

Shield
F
OR

Power supply PWM


+
K2

+ Actuator +
Actuator -
F
G9 G11 G10 K4 K5

Emergency
A3

stop
Analog
+
G

AVR out +
Crank
AVR

CRANK -
A1

relais out AVR out -


Shield 1
H2 H4 H3

+Alim

Fuel
A2

FUEL relay out


F

Gen L1 100 - 480 V


L1

Gen L2
L2

Gen L3
L3

Gen N
N

B2 B3 B4 B1

SPARE Output 1
C1
S1
P1

Gen I3+ 1-5A


D2

Spare output examples:


- +/- speed to speed governor
SPARE Output 2
- Engine preglow
C2

Gen 3-
D1

- Visual / Audio alarm


- Generator breaker trip
S2

- Lubrification pmp
P2 S1
P1

- Reverse power Output 3 Gen I2+


D4

- ... SPARE
C3

Gen I2-
D3
S2

Output 4
SPARE
C4
P2 S1
P1

Gen I1+
D6

Output 5
C5

SPARE Gen I1-


D5

+Alim
S2
P2

Shield
F5

Gen common
E6
- Alim

Oil pressure meas. -


F8

Gen Breaker NO
E5

Oil Pressure
Oil pressure meas. +
F9
E4

Gen Breaker NC
Water temp meas. -
F6

Water temp
Water temp meas +
F7
Load

Engine meas. 1 -
F1

Spare 1 Mains common


E3

Engine meas. +
F2

Mains Breaker NO
E2

Engine meas. 2 -
F3

Spare 2
Mains Breaker NC
E1

Engine meas. 2 +
F4
- Alim

100 - 480 V
F

Mains L3
L3

Mains L1
B6 B5
S1
L1 P1

Shield Mains I1 +
D8

0-20mA -

G2 G3
Mains power or spare Mains I1 -
D7

analog input +/- 20mA or +/- 10V


GENSYS
S2
P2

0-20mA +

G1
Shield
Parallel +
Mains

G5 G6
Parallel lines to GCR or BC
analog load sharing Mains breaker IN
J1

Parallel -

G4
Gen Breaker IN
J2

Spare input examples:


Remote start/stop
J3

- +/- speed inputs


- Low temp warning
Oil pressure J4 - Low water level
RS485 / MODBUS - Low fuel warning

6 - Tx

9 - 0V
5 - Rx
4 - 0V
3 - 0V

8 - NC
7 - NC
2 - NC
1 - NC
- Charger fault

RS 485
Water temp

J5

DB9 male
- Air damper shut
- Exter electrical fault
Input 1

J6
- ...

Infos / Alarms
/ realtime display
Configuration / tele-maintenance
(MDEC,...)
Input 2

J7
CAN1 to

6 - 0V
5 - 0V
3 - 0V

9 - NC
8 - NC
4 - NC
1 - NC

Remote E/S, Cogeneration


other GENSYS

CAN 1

management,... (CRE options)

Engine management system


2 - CANL

DB9 male
7 - CANH
Input 3

J8
Input 4

J9

/ realtime display
Configuration / maintenance
CAN 2 to options Input 5

...
6 - 0V
5 - 0V
3 - 0V

9 - NC
8 - NC
4 - NC
1 - NC

CAN 2
DB9 male
2 - CANL

7 - CANH
Input 6

J10 J11

Modem
Modem
Input 7

J12
RS232 to PC or modem Input 8

J13

9 - RI
2 - Tx

5 - 0V
3 - Rx
1 - NC

RS 232
8 - CTS
7 - RTS
6 - DTR
4 - DSR

DB9 female
Input 9

J14
- Alim
Input 10

J15