Sie sind auf Seite 1von 1

Operational Note: Powering Down CLARiiON CX4

Series Systems with DC Power


and FLARE Software 04.28

DC-powered CX4 series systems Powering down a DC-powered CX4 series


running FLARE software release system
R28 may not efficiently destage 1. Stop all I/O activity to the storage system.
write cache during the Stopping the I/O will allow the storage processor to
powerdown procedure described destage the cache data more quickly, and will permit a
in your installation and operating graceful shutdown of the servers attached to the array.

!
guidelines. To ensure the 2. If the server connected to the storage system is
complete and clean transfer of running a UNIX operating system, unmount the file
cached data to disk, follow this systems.
procedure.
3. Destage write cache from the Navisphere Secure
Command Line Interface. Perform this step on either
SP A or SP B:
a. Issue the following Navisphere command to disable
the write cache and to complete the destage of cache
data:
naviseccli h <sp_name> setcache wc 0
b. Issue the following Navisphere command to
determine when the destage is complete (on a large
configuration; this can take several minutes):
naviseccli -h <sp_name> getcache
c. Examine the Cache state and unassigned cache
pages fields in the Navisphere display. Do not
continue unless cache is DISABLED on both SPs and
the number of unassigned cache pages is 0.
SP Read Cache State Disabled
SPA Write Cache State Disabled
SPB Write Cache State Disabled
Cache Page size: 2
Write Cache Mirrored:YES
Low Watermark: 60
High Watermark: 80
SPA Cache pages: 604415
SPB Cache pages: 604416
Unassigned Cache Pages:0
Read Hit Ratio: N/A
4. On the storage processor enclosure, push the power
button on each power supply and hold the button in
for two seconds. Blinking power supply LEDs indicate
that the shutdown sequence is in progress. Allow two
minutes for the array to power down completely.
5. You can retain power to other devices in a rack/
cabinet, or shut down power distribution units A and
B. To shut down an individual DAE, toggle its power
switches to the off position.

Copyright 2008 EMC Corporation. All rights reserved. P/N 300-008-620 Rev A01