Multimedia Server
System Installation Debug Manual
Version 1.0
ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen,
P. R. China
518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this
document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is
prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of
their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions are disclaimed,
including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE
CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained
herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject
matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of
this document shall not acquire any license to the subject matter herein.
The contents of this document and all policies of ZTE CORPORATION, including without limitation policies related to support or training
are subject to change without notice.
Revision History
ii
5.6.1 MSU............................................................................................................................................ 130
5.6.2 MDU ........................................................................................................................................... 131
5.6.3 MSCU ......................................................................................................................................... 131
5.6.4 MSTUKLinux cards............................................................................................................ 131
iii
Chapter 1 Server 129 Installation
Abstract:
The background server software includes the SQL Server 2005 server 129 installation and
the EMS network server and client installation. The proper startup of server 129 is the
prerequisite of the subsequent version installation and startup.
The default database file of SQL Server must be installed in drive D and the free space in
drive C must be greater than 30G.For the detailed modification.
2
Chapter 1 Server 129 Installation
If Windows is not installed with the IIS component, it will prompt alarm information. The
SQL Sever 2005 Reporting Services component needs the IIS service. But the EMS
database does not need this component, so ignore this alarm and go to the next step.
3
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
To lessen the server load, install the minimum components required by the EMS database.
Click the "Advanced" button to enter into the advanced function selection interface.
Choose to install the following components:
Database service
Documentation, demonstration and demo database (SQL Server online books only)
Then make sure that the free space of drive D is more than 30. To install the default
database file in drive D, first select "Database service", choose "Data file" in the
directory, and click "browse" to change drive C to drive D and click "OK".
4
Chapter 1 Server 129 Installation
5
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Select the hybrid mode. The password is determined on site. The password must conform
to the password rule (The password of the "sa" user that EMS uses is "netnumen". If the
"sa" user configuration is not "netnumen", then configure the database password to be the
corresponding password after the installation of EMS mini network management to
perform the database connection test.). The EMS database script needs to use this
password.
6
Chapter 1 Server 129 Installation
7
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
So far, SQL Server 2005 has been installed. Currently, in order to correct bugs, the
SQLServer2005 SP3 patch has been released. Therefore, we will have to install the SP3 patch
to SQLServer2005. The version information is 9.00.4035.00 (For SQLServer2000, also install
the SP4 patch of SQLServer2000.).
8
Chapter 1 Server 129 Installation
As shown in Figure1.22, for first installation, select "install"; for subsequent upgrade,
select "upgrade. Then click "Next".
9
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
3 Input the user name and password same as those of the operation system to be
installed, and verify them, as shown in Figure1.23.
10
Chapter 1 Server 129 Installation
6 Select the type of maintenance device. Here select "USS100".as shown in Figure1.2-6.
11
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
8 For a new system, it is necessary to initialize the database. Tick all the names of the
database system. If it is an upgrade, it is necessary to retain the database contents. Do not tick
them in installation. Select the installed sub-system database. Select all, as shown in
Figure1.2-8.
9 Communication configuration
Set the foreground and background communication configuration, as shown in Figure1.29.
12
Chapter 1 Server 129 Installation
1 For the foreground host IP, we can configure a temporary IP first. After the OMP version is started,
view the real IP of eth3 in system B on the SOMP card, change the corresponding IP of the
c:/zxmsg/CommCfg.ini configuration file. Currently, in the initial database of the OMP construction
version, the maintenance IP of the foreground OMP is 129.0.31.254. If OMP started once, the
maintenance IP will be changed to 129.0.31.1.
2 Server IP: Local IP of server 129 which should be configured to the address of 129 network
segment, for example, 129.0.1.129, subnet mask: 255.255.0.0.
Note:
2 The communication IP of server 129 and the subsequent SOMP server must be in 129
segment.
13
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
After the service is started properly, the status appears, as shown in Figure1.32.Do not close it,
or you will close the 129 service.
14
Chapter 2 Network Management Installation
2.1 Environment Requirements
Minimum installation environment requirements:
2 1G memory space
Extract the installation package. The files inside are described as follows:
install_helper.exe Installation auxiliary tool in Windows system, such as free disk space check,
and progress display.
In the Solaris system, it is not authorized to run "install.sh". Modify the authority in a way as
follows and run it again.
./install.sh
Then, as shown in Figure2.3-2, input the installation path. Make sure that the free space for the
installation path should be greater than 2G. Otherwise, the installation cannot go on.
Note:
Do not install the network management system in a directory with a Chinese path name or
a path with space characters.
16
Chapter 2 Network Management Installationn
Press "Enter" to install the NM system to the default path c:/netnumen. Or input "d" to install
the NM system to the path d:/netnumen. Or decide the installation path according to the on-site
server situation. After the path is inputted, select the EMS installation type, as shown in
Figure2.3-3. 1 is for client terminal. 2 is for client terminal and server. It is required to select 2
in the construction site.
After selection, install EMS. The installation procedure is shown in Figure2.34. Extract all zip
packages under the installation directory in order.
17
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
In a few minutes, the installation is completed, as shown in Figure2.3-5.Start the "config center"
interface. For detailed configuration operations, refer to the instructions in 2.4.
After installation, perform the configuration directly. In case of any subsequent modification,
start the configuration center by the means shown in Figure2.41.
18
Chapter 2 Network Management Installationn
2.4.2 NE Configuration
19
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
The database configuration interface is shown in Figure2.43. The database user name and
password need to be consistent with those of SQL. By default, the sa password of SQL Server
2005 is netnumen.The default sa user password configured on the EMS mini NM is netnumen.
If the sa user password is modified previously in SQLServer installation, use the actual
SQLServer sa user password.
As shown in Figure2.44, click "Test connection (T)" to start connection test. If Database
connection is successful" appears, it indicates that the test is OK. Otherwise, check whether the
SQL Server database is opened, or whether the sa password of the database system
administrator is correct.
20
Chapter 2 Network Management Installationn
2.4.5 ID Authentication
Note:
If it is EMS, change the Windows authentication mode in MS SQL Server to the hybrid
mode of SQL Server and Windows.Server 129 supports two modes. But for the EMS
server, it must be the hybrid mode.
Enter into the SQL Server 2005 Management Studio, as shown in figure 2.46.
21
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Click "Connect".
Click "Property".
22
Chapter 2 Network Management Installationn
Select "Security".
23
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Choose "Server ID authentication" to be SQL Server and Windows. After modification, restart
the database.
Note:
After the database is initialized, the original data will all be lost. In a new commissioning
or only when the original data can be discarded, can the database be initialized.
After initialization, check whether the database in the management studio is the same as the
figure 2.5-2.
24
Chapter 2 Network Management Installationn
2 Make sure that the server process management has started. Otherwise, restart the PC.
Double-click the "NetNumen N31 Server" shortcut on the desktop to start the NetNumen
UNMS console, as shown in Figure2.6-2.
25
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
3 By default, the console will automatically start the NetNumen NM process, CORBA
information service process, FTP process (Auxiliary NetNumen process). After the processes
complete, a green square icon will appear on the window. Wait until three services are started
successfully.
4 Double-click the "NetNumen N31 Client" shortcut on the desktop to start the NetNumen
UNMS client login interface, as shown in Figure2.6-3.
5 In "Server address" of the login window, input the IP address of the machine that the NM server
resides on, "user name", and "password. By default, the admin user's password is empty. Click
"OK". The client terminal continues to start. After the startup, the following interface appears.
26
Chapter 2 Network Management Installationn
Note:
When starting the machine of the EMS server, do not start other FTP services; or it may
affect the EMS FTP functions.
1. Preparations
NMS is installed. Database is installed. The service terminal can start each service process, as
shown in 2.7-1.
27
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
The NM client terminal is started properly and the default NM client interface can be displayed,
as shown in figure 2.7-2.3.
28
Chapter 2 Network Management Installationn
2. Creating NE
a) Creating group: To create a group is to manage the NE well and make the NE topology clearer.
Groups can be created on the Topology Tree on the left side of the "Topology Management"
interface, as shown in figure 2.7-4.
29
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
30
Chapter 2 Network Management Installationn
1 Creating NE: NE is created in "group". If a group is not created, the NE will be created in the
default group. There are two methods to create an NE.
Click Main view - Topology root. Select a group and right-click to create an NE, as shown
in figure 2.7-7.
31
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Figure2.77 Create an NE
Click the panel on the right of topology management. Select a group and right-click to
create an NE, as shown in figure 2.78.
Figure2.78 Create an NE
32
Chapter 2 Network Management Installationn
Figure2.79Create NE
2 Configure NE
Figure2.710Basic Property of NE
Note:
e User name, password, confirmation password: Device account for NMS login; Default:
admin; If the password of the admin user at the side of the device, it is necessary to
synchronize there.
Figure2.711Basic Property1 of NE
Note:
a IP1: Maintenance port address on OMP card; NM manages device through this device.
b Protocol type, link type: Corresponding to the ZXUSS device; to reserve the default
value
f EMF module: An unique mark that NM registers on the ZXUSS device; For a same
ZXUSS device, this module must be unique. The value range of this field is 130 - 300. For
one ZXUSS device, there are normally two sets of NMSs. One is for local operation and
maintenance, the other is for a centralized NM. Therefore, it is necessary to distinguish
this EMF module number of these two systems.
34
Chapter 2 Network Management Installationn
Figure2.713New NE
3. Modifying NE
35
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
On the topology tree or map, select the NE to be modified. Right-click the menu to modify
NE, as shown below:
Figure2.714Modify NE
4. Deleting NE
On the topology tree or map, select the NE to be modified. Right-click the menu to delete NE.
5. Policy Configuration
For ZXUSS management functions, it is necessary to configure "Stream media Abnormal Data
Clearing Policy" and "Service-layer Device_USS100_Performance Data Table Backup Clearing
Policy". Take the "Stream media Abnormal Data Clearing Policy" as an example.
a) On the main interface of the client terminal, select "View" -> "Policy Management" to
open the policy interface, as shown in
36
Chapter 2 Network Management Installationn
Figure2.715
b) Click "New" on the "Policy Management" interface to enter into the "Create
Measurement" interface to configure the basic information.
Figure2.716
Note:
37
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Figure2.717
Note:
a Select the start time in a time when the NMS load is small, such as early morning. For
different policies, this time point must be kept at intervals of 30 minutes to avoid multiple
policies from running at the same time.
38
Chapter 2 Network Management Installationn
Figure2.718
Note:
Retention days: Days of abnormal original data of stream media to be retained; When the
number of NEs is less than 10, retain the data for 3 days; less than 20 NEs, 2 days; greater
than 20 NEs, 1 day.
39
Chapter 3 SOMP Card Installation and
Startup
Abstract:
This chapter is to introduce the version software installation procedure of the foreground
SOMP card.
Remark: logical shelf number = physical shelf number-1, logical shelf number=physical
shelf number-1
Note:
In the following DIP switch diagram, the black block indicates the DIP switch location.
When the switch is at OFF side, it indicates that the switch is set to OFF=1 by default.
When the switch is at ON side, it indicates that the switch is set to ON=0.
Note:
Before boot, each rack needs to construct a SOMP boot version. It is not needed later. This
operation procedure needs to be completed on server 129. Upload all versions to server
129.
42
Chapter 3 SOMP Card Installation and Startup
1 First, extract the c:\zxmsg\starttool.exe compression package on server 129 to generate the
msgstrt package.
2 Then copy the version files of the foreground SOMP card to the sub-folder of the msgstart
folder, including CPU-x86 version and FPGA version. Refer to Table3.11.Normally, copy
version files to the c:\zxmsg\msgstart\MSCU\ directory. The directory is specified on site.
4 Select "Left OMPConfigure Info and right-click it to select "CPU Ver Configure Info
43
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Select a CPU version file in the version directory. The file name is
USS_MSCU_MP_X86_V1.00.04.01U01_H.USS. The interface appears, as shown in
Figure3.24.
44
Chapter 3 SOMP Card Installation and Startup
45
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
The small version number should be consistent with that of the configured CPU. The file name
is ZXUSS_MSCU-080101-FPGA_04_H.rbf. The interface appears, as shown in Figure3.2-7.
6 Select the MP type. Select OMP, SMP, CSU, and MSCU, as shown in Figure3.29.
46
Chapter 3 SOMP Card Installation and Startup
8 After the version information is configured, in Figure3.21, click "Construct OMP Vers Info".
The saved file name is "ompcfg". Please note to use the default "ompcfg.ini" when typing
the file name. The system will automatically add the extended suffix name .uniform details,
refer to Figure 3.2-10.
47
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
48
Chapter 3 SOMP Card Installation and Startup
2 Log into SOMP (Use a terminal directly or use a tool, such as "Secure Shell Client"
remotely.)
3 Get the SOMP version file ready. Obtain the version file from the version server according to
the version list. For the details, refer to Table3.3-1.
total.INI
HlpClass.txt
MpDbCfgInfo.INI
HlpMsg.txt
1. The delivered card has the software version which runs automatically. First, check whether
there are any versions running. Method: Log into the SOMP operation system System B shown in
figure 3.3.1).
Use the "ps -A|grep MSCU" command to check whether there is an _USS_MSCU_MP_X8
procedure. If yes, it indicates that the version has already started. If the version has started, log into
the SOMP operation system. Run "telnet 127.0.0.1 1026". Username/password: zte/zte. After login,
run the "kill" command to stop the version. Note: stop the active and standby OMP versions first and
perform the following operations.
If a reinforced script is running on the delivered card, roll it back manually. Method: Log into the
card. Use the "su - root" command to switch over to the "root" user and assign the execution
authority to the rollback script "home/rollbak_sec.sh" of the original version, namely, chmod +x
rollbak_sec.sh. Under the home directory, run "ollbak_sec.sh -c no -t mstu y" and delete ALL
files under the /home" directory.
Note: Execute the rollback and deletion operations on both active and
standby OMP cards.
The following step 2 to step 8 should all be performed on active/standby SOMP. Perform
the steps on the active SOMP first and then on the standby SOMP.
50
Chapter 3 SOMP Card Installation and Startup
51
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Note
3. If the card is in single user mode, connect the monitor to OMP. Carry out the following
command to repair it.
none# swapon /dev/hda2 (according to the real situation, corresponds to the switch
disk of the card.)
3 Create the following directories on SOMP. Pay attention to the case and create the directories
strictly as follows:
1 /home/VER
3 /home/dbs/DATA1
4 Upload the corresponding version files manually to the directory of /home/VER on SOMP
(they are the four constructed version files in chapter 3.2.)
Note:
1 When uploading version files, use PC locally or use server 129. The condition is that
eth3 network of SOMP can be reached.
2 When uploading files, use the "SSH Secure" tool in binary system.
2 FPGA versionZXUSS_MSCU-080101-FPGA_04_H.rbf
52
Chapter 3 SOMP Card Installation and Startup
6 Copy the initial data /DATA1/ to the directory "/home/dbs/DATA1" of the SOMP card to
ensure that the directory construction is shown in as follows:
1 CfgTable.ZDB
2 DBVer.ZDB
3 VerTable.ZDB
# pwd
/home/dbs
# ll
# pwd
/home/dbs/DATA1
# ll
#/home/MSCU_Boot.exe
1 Check whether the eth3 IP is reset to the specified IP: 129.0.31.254, and whether the
foreground and background can ping each other.
Note: The SOMP IP uses the original ZDB. The first started SOMP maintenance IP is
129.0.31.254. If the SOMP version or system is restarted, the SOMP maintenance IP will be
changed to 129.0.31.1. It is necessary to modify the configuration on server 129 according to
the real situation. Modify two files. The BoardIP field value in the /zxmsg/CommCfg.ini file
53
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
should be changed to the eth3 IP on the foreground SOMP. The IPAddr field value in the
/zxmsg/IpAddrs.cfg file should be changed to the eth3 IP on the foreground SOMP.
4 Check the indictors on the SOMP card. The normal status is: The RUN LED is ON and OFF
alternately; the ALARM LED is OFF. The ACT LED is constantly ON.
5 After an NE is created on EMS, we can see that the NE link status is normal.
6 The foreground and background communication is normal. On server 129, through
Ctrl+Alt+F12, check the communication status between server 129 and the foreground OMC. As
shown in Figure3.32, the Status should be "True".
1. Because the started FTP service on SOMP may prevent cards from obtaining version
information, it is necessary to close the following services. Method:
Log into SOMP with SSH Secure and switch over to the root user. Input "chkconfig | grep ftp", as
shown in figure below.
54
Chapter 3 SOMP Card Installation and Startup
If the status of "pure-ftpd" and "vsftpd" is not OFF, use the chkconfig pure-ftpd off and chkconfig
vsftpd off commands to close it and then use the /etc/init.d/xinetd restart command to effect the
modification.
2. If other routes except the following routes are configured on the OMP eth3 interface, delete
them all.
linux:~ # route
128.0.30.0 * 255.255.255.0 U 0 0 0
eth1
128.0.0.0 * 255.0.0.0 U 0 0 0
vlan10
129.0.0.0 * 255.0.0.0 U 0 0 0
eth3
130.0.0.0 * 255.0.0.0 U 0 0 0
eth2
192.0.0.0 * 255.0.0.0 U 0 0 0
vlan10
193.0.0.0 * 255.0.0.0 U 0 0 0
vlan20
loopback * 255.0.0.0 U 0 0 0
lo
3.4 Adding NE
Add an NE on the EMS client terminal. According to Figure 3.4-1 to configure the basic
properties and then configure the NE basis according to Figure 3.4-2.
55
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
3 Location: any
4 User and password: admin/admin; This is the initial password. It can be modified later.
2 Port: 5057
56
Chapter 3 SOMP Card Installation and Startup
3 EMF module: 156Permitted range of EMS module number: 144 - 254; Default: 156If this
NE is added to multiple NMs (for example, a same NE is created on the big NM and small
NM), it should be noticed that the EMF modules to be filled in should be different when this
NE is created on the different NMs.
In this case, the MSU rear plug-in card does not have to connect the network cables on the
media plane and the control plane.
Control Plane 1G
Shelf1Rack2
RMSU RMSU
There is only one media shelf, therefore, the media plane does not need to be cascaded.
57
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
58
Chapter 3 SOMP Card Installation and Startup
59
Chapter 4 ZXUSS-Side Configuration
Abstract
Start SOMP and then implement ZXUSS-side configuration. Add cards of all nodes in.
The NEs are supposed to have been added in properly.
Enter ZXUSS global basic properties configuration interface as shown in Figure below.
Configuration steps:
2Area number: 0-999 (Default number: 0), which keeps consistant with the areacode of
win_mgt.ini in Section 6.1.1. The following Figure shows the areacode.
Figure 2 Areacode
62
Chapter 4 ZXUSS-Side Configuration
3 Office number: Set local office number for WINTCP (for different USS, the office number
must be different). It is not a dip switch office number. In the rack chart, the card control
plane IP is calculated as the dip switch office number.
4 IP address: Configure the SOMP and background server 129 address used for
communication. To modify the IP address, you must restart the OMP first.
5 MAC address: It can be set to any number. Because our company manages and uses with
00-d0 as the start numbers, in projects, we usually use the address format as 00-d0-office
number-rack/shelf number-slot number-module number to define MAC address. For
example, we use 12 to indicate rack 1, shelf 2 and 22 to indicate rack 2, shelf 2.
63
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Figure 4.1-4 Time Zone and Daylight Saving Time Configuration Interface
Configuration steps:
64
Chapter 4 ZXUSS-Side Configuration
1. Media plane IP address prefix: 1-254 (the default number is 127), if the prefix is modified, all
sub-unit media plane IP addresses must be adjusted accordingly in the background.
2. USS certification code: The code is ussed for RTSP certification between USS. The code is
one in range 1-64, no default number.
3. Timeout demolition time: It is the time for STB demolition when the subscriber is at pause
status. The unit is second. The time can be confiugred to one in range 1-300. By default, it is
50 seconds.
4. Program source lack and STB screen malfunction: When the program source which is listed in
the program plan is lost, if it causes STB screen malfunction or typed enum. Default 1: screen
malfunction.
8. Preoccupy sources while live broadcasting or time shifting: It refers to the MDU or MSTU
source preoccupation while in live broadcasting or time shifting. By default, it is 0. 0 means
not to preoccupy.
9. Timeout demolition or not: When the STB pause time is out, USS demolites or not. By default,
the configuration is 0. 0 means not to.
10. Service on or not when disk space is not sufficient: By default, it is 0. 0 means not to provide
service any more.
11. Enable aging policy or not: By default configuraiton, USS does not support aging. The aging
funciton is initiated by MLSS.
12. Temporary channel threshold value: Use percentage to represent the total resources and
unoccupied resources ratio in the MDU sub-card. By default, the percentage is 50.
13. MDU unoccupied resource threshold value: Use percentage to represent the unoccupied
resources and the total resources ratio in the MDU sub-card. Use the default configuration
14. Shift-out subscriber threshold value: Use percentage to represent the shift-out subscriber and
total subscriber ratio. By default, the value is 50.
15. The following condtions must be satisfied when a temporary channel is set up:
aMDU sub-card unoccupied resources > Main channel specified MDU sub-card unoccupied
resources
cMDU sub-card is not the MDU sub-card which connects with the main channel.
65
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
fMDU sub-card unoccupied bandwidth the bandwidth occupied by the shift-out subscribers
iMDU sub-card occupied bandwidth + shift-in subscriber occupied bandwidth < temporary
channel threshold value
16. Subscriber shift-in threshold value: If the MSTU external resource occupation rate is lower
than the threshold value, subscribers are allowed to shift in. The value ranges from 0 to 100.
The default value is 70.
17. USS node identity: It must keep consistent with the configuration of MLSS. It has limits on
the upper and lower cases. The unitid created for CDN-Manager is obtained after being
operated in the portal iptvcdn gate. Refer to Figure 6.2-3.
18. USS node protocol type: It can be valued 1 or 2. 1 means WINNTTCP. 2 means SIP. By
default, it is 1.
19. File open frequency: By default, it is 0. 0 means the field is supported by USS on following
aging accumulation.
20. Filing directory: /iptv/Arch/, it cannt be modified once time-shift channel is set up. If it is
modified, the previous filing partition cannt be used any more. Carry out man-machine
commands to modify.
21. NTP local port: It is the NTP local external port. By default configuration, the port ID is 123.
22. Message tracing label: The label can be used for smoking test. By default, the configuratoin is
0.
23. Multi-shelf auto route-selecting label: It is used to configure to select resource shelf MSU
connection automatically or MSU connection specified by physical configuration. 0 means
automatically select. 1 means not to select automatically. By default, it is configured to 0.
24. Time-shift route: /iptv/Tvod/, it cannt be modified once time-shift channel is set up. If it is
modified, the previous filing partition cannt be used any more. Carry out man-machine
commands to modify.
25. Congestion message discard level: When the message volume is very big, discard some
message below a specific level. By default, it is configured 255. 255 means not to discard.
66
Chapter 4 ZXUSS-Side Configuration
26. VOD garbage clearance: When the content corresponding to overall routes is not listed in the
content table, the corresponding record in the content table can be deleted. By default, the
configuraiton is 0. 0 means to disable this function.
27. MTU: Set the maximum packet size for MTU. The size ranges from 1400 to 1500. By default,
it is 1500.
28. Maximum high-definition byte rate: Unit: Kbytes, Range: 100-9600, Default: 9600
29. High-definition byte rate limit: 1-9600, Unit: Kbytes, if a byte rate is bigger than the limit
value, it means high-definition. If a byte rate is smaller than the limit value, it means
standard-definition. By default, the limit is valued 2500.
30. Live broadcast pause time-shift time: Unit: s, Range: 1-20, Default: 5
31. Maximum MDU channel number: It refers to the maximum number of access channel or
provided channel in MDU. For the existing number, it is recorded in r_unitex channelnum1 or
channelnum2.
34. Maximum FEC support capability: It refers to the maximum FEC capability supported by
each MSTU. Take encoding and decoding as two capabilities. So a FEC which encodes and
decodes has two capbilities. By default, a FEC has 80 capabilities.
35. Maximum single transcoding channel: It refers to the single transcoding channel supported by
each MSTU. The single transcoding channel refers to transcoding but no time-shifting
channel. By default, it is 70.
67
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration specification:
37. Relay channel subscriber port number: Range: 200-500, Default: 250
38. Enable L3 check or not: Enum type, Default: 1, 1 means enabled. It is recommended to use
the default configuration.
39. Changeover or not in case of L3 check failure: Enum type, Default: 1, 1 means not. It is
recommended to use the default configuration.
40. Corresponding to MLSS version: Range: 1-5, Default: 3, 3 refers to the version 3.03.03U2.
41. Fan temperature check type: Enum type, the value 1 refers to taking the inlet temperature as
the fan temperature. 0 refers to taking the outlet temperature as the fan temperature. The
default value is 0.
42. Partitioning packet default module: Range: 1-32, Default: 1
43. MSTU inlet check: Enable the MSTU inlet packet loss check or not. Default value is 1. 1
means enabled.
44. MSTU inlet check period (s): The period refers to the MSTU inlet packet loss check period.
By default, it is 2.
45. MSTU inlet packet loss threshold value: By default, the value is 10.
46. Chunk verification deletion: The fault value is 1. 1 refers to verification deletion.
47. VOD aging threshold: VOD program ages. According to the capacity percentage, the fault
value is 80.
48. VOD aging interval: It refers to the period between the current time and time of last visit. By
default, the interval is 48.
49. Current node subscriber concurrency number: It refers to the maximum subscriber
concurrency number at a current node. Default number is 4000.
Configure the concurrency number according to the practical commercial requirements and
configuration capability.
68
Chapter 4 ZXUSS-Side Configuration
50. Service node ID: It is used for live broadcast service menu without default configuration. The
service node is identified by the node ID.
51. IGMP configuration: It refers to the MDU IGMP configuration. By default, the configuration is V2.
52. Node broadcasting type: This configuration consists of two values. One is the unicasting node. If this
parameter is configured, the node provides live unicast service for subscribers. The total capability
and the rest capability reported by VS8000C to MLSS keep the previous the same to MDU+MSTU
concurrency capability and the rest MDU+MSTU concurrency capability. The other is the
muticasting node. If this value is configured, the node does not provide live broadcasting service to
subscribers. And the total capability and the rest capability reported by VS8000C to MLSS only
consist of MSTU capability, not including MDU capability. That means only MSTU total
concurrency capability and the rest MSTU capability are reported.
53. Single node or not: If there is single node, configure YES. If there are multiple nodes, configure NO
by default.
54. Poweroff label enabled or not: This configuration is the shelf poweroff configuration. We suggest
using the NO configuration. If the configuration is YES, the shelf can be poweroff in case a card
reaches the configured poweroff temperature.
55. Node pulling maximum partition number: The number refers to the partition pulling between nodes
and the maximum pulling partition number. By default, it is 100.
56. Channel pulling maximum partition number: Channel pulling by partitions. The single channel
maximum concurrent partition number is four by default.
57. Subscriber data field size: It refers to the maximum RTSP subscriber number. It is 8000 by default.
58. Maximum stream break (s): If it is over stream break, there initiates an alarm. By default, the time is
30 seconds
69
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Select NetNumen N31 and command line terminal and then enter 4022. Modify subscriber
convergence moveback configuration item (A and U information as shown in following Figure) to be
1, meaning not moveback.
70
Chapter 4 ZXUSS-Side Configuration
71
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
72
Chapter 4 ZXUSS-Side Configuration
73
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration specification:
3 Global rack number: The global rack number is unique at this node. The rack which
configures the control shelf is identified as number 1.
4 A rack with multiple shelves: The control shelf and resource shelves are set in different
racks.
74
Chapter 4 ZXUSS-Side Configuration
Configuraiton specification:
1 Single shelf: The shelf must be identified number 2 and the shelf type must be
240-ST_USS_COMMON_BCTC, which refers to the control shelf.
2 Multiple shelves: The control shelf must be rack 1 shelf 2. Except one control shelf, the
type of other shelves must be 240-ST_USS_COMMON_BUSR which refers to the
resource shelf.
3 Global multiple rack: There must be only one control shelf. Other shelves are resource
shelves.
4 Consistency: The specific configuration must keep in consistency with dip code. For
details, refer to Table Table3.11.
75
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
76
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
1 For each shelf, the MSU card must be configured first. MSU card can only be configured at
slot 7 and 8 as active or standby cards.
77
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 Configure SOMP card at slot 9 or 10 as an active or standby card. Configure card type to be
211-BT_USS_MSCU.
78
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
1 Configure multiple MSCU cards as actual service required. And the active/standby MSCU
cards must be configured in control shelf at slot 5/6, 11/13, 12/14, 1/3 and 2/4 sequencely.
Set the card type as 211-BT_USS_MSCU.
79
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
80
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
1 MSTU card must be configured to be no standby card. So the card type must be set as
MSTU.
2 As to a configuration with multiple shelves, the MSTU cards must be set in medium shelf at
slots 1/3, 2/4, 5/6, 9/10, 11/12 and 13/14.
81
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
82
Chapter 4 ZXUSS-Side Configuration
1 Enter 1 for module number and select module type as OMP, SMP, MSCU or CSU.
3 CPU number1
4 Signal forwarding loop selection ratio: For any circumstance, enter 1 for module 1.
1 Enter 2 for module number and select module type as SMP or MSCU.
3 CPU number2
4 Signal forwarding loop selection ratio: In case of two modules at one node, enter 2. In case of four
modules at one node, enter 3.
83
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
1 Enter 3 for module number and select module type as SMP or MSCU.
3 CPU number: 1
4 Signal forwarding loop selection ratio: In case of four modules at one node, enter 3. For the
module number over four, the configuration is undetermined.
1 Enter 3 for module number and select module type as SMP or MSCU.
3 CPU number: 2
84
Chapter 4 ZXUSS-Side Configuration
4 Signal forwarding loop selection ratio: In case of four modules at one node, enter 3.
After adding all modules, modify module 1 capacity configuration as shown in the following
Figure.
Click the Modify capacity configuration button to modify the current value to be 120,000.
86
Chapter 4 ZXUSS-Side Configuration
Adding procedure:
Select All current node MSU All current node MDU Medium shelf 1 all MSTU (slot 1 to 14)
Medium shelf 2 all MSTU (slot 1 to 14)
1Adding a MSU
87
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
Module number: MSU must be configured at OMP. So select module 1 for MSU
number.
88
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
Sub-system configuration:
- Range: 0-255
- Default: 0
- 1: 50
- 2: 60
- 3: 70
- 4: 80
- 5: 90
89
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
1Adding a MDU
Configuration Specification
1 Module number: The current version only supports the MDU being configured to CSU. So MDU
can only be configured to Module 1.
2Sub-unit modification
90
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
1 Set 12 sub-unit as the signal interface and sub-unit type as 244-SUT_USS_MDU_SIG. The signal
interface can be set as required only if one node has one signal sub-unit.
2 Set the rest sub-units (18, 19, 20, 10 and 11 as medium interfaces. Set the sub-unit type to be
232-SUT_USS_MDU_EXTRIP.
Check network ports in MDU hardware backplane. From top to bottom, the sub-units in
sequence should be 18-19-20-10-11-12.
91
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 Configure external port IP, mask and default next-hop IP (NG IP) addresses as required.
2 MAC address: ZTE uses MAC address with 00-d0 head. In construction project, we suggest
configuring on the following principle: 00-d0 - CO number rack/shelf number slot number
unit number
3 L3 check interval: 0
92
Chapter 4 ZXUSS-Side Configuration
93
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification (If the node contains unicast channel, perform the following configurations 1-3.
Otherwise, ignore.):
1 The configuration refers to add or delete. When carry out add, enter the starting and terminal
circuits. The circuits range from 0 to 399.
2 The external port circuit configuration refers to the channel access port allocation. That is, the IP
and port of the live broadcast source SDP must be configured when a channel is added. The
configuration mirrors to the foreground data table r_channelset. If the information is not configured
or the configuration does not match, when a channel is created, the return application MDU failure
occurs. The first 400 external port inlet resource configurations must be set for each MDU
none-signal external port sub-unit.
3 When the channel access method is multicasting, idle channels must be provided because the added
circuits cant be the multicast access circuits. That is, when USS edge node needs 100 network
multicasting channels to receive the multicast code stream, with 100 idle channels, 0-299 channels
are to be added.
94
Chapter 4 ZXUSS-Side Configuration
Note
Restart all OMP cards after modifying MDU sub-unit type and forwarding module 1
variation table. And then restart all MDU cards.
1Adding a MSTU
95
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 Module number: Allocate MSTU according to physical allocation to avoide cross module operation. In
engineering, evenly allocate MSTUs to all modules.
Check network port of MSTU hardware backplane. 11 refers to the downlink port and 12
refers to the uplink port.
96
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
1 Configure external port IP, mask and default next-hop IP (NG IP) addresses as required.
2 MAC address: ZTE uses MAC address with 00-d0 head. In construction project, we suggest
configuring on the following principle: 00-d0 - CO number rack/shelf number slot number
unit number L3
2 Enable L3 check interval, switchover, loopback or not. These three configurations are not enabled
currently. It is recommended to use the default configuration.
97
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Modify the MSTU resource threshold value in NetNumen N31 as shown in the following Figure:
98
Chapter 4 ZXUSS-Side Configuration
If the file system IO resource is enough, such four resources as internal input bandwidth
resource, internal output bandwidth resource, external input bandwidth resource, external
output bandwidth resourceare are enough too (except for both internal or both external
ports being faulty). So use the default four configurations.
File system IO resource: Configure as required and ensure: the preserved resource
threshold Max. value + Max. FTP preserved percents = 100%.
The following table lists configuration parameters:
The following table lists file system IO resource allocation respectively for marginal node
MSTU, central node and regional node.
The Preserved Resource The Preserved Resource Min. FTP Preservation Max. FTP Preservation
Node Type
Threshold Min. Value(%) Threshold Max. Value(%) (%) (%)
Central node 0 50 20 50
Regional
0 50 50 50
node
Marginal
0 80 20 20
node
99
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configure as the following for regional node which is providing much service to many
subscribers.
Regional
0 60 40 40
node
100
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
2MSTU cards 1/3, 2/4, 5/6, 9/10, 11/13 and 12/14 are working as active and standby cards in pair.
4MSTU cards must work in pair. Both active and standby cards must be configured. If only one card
is configured, we reserve the right to acquire the commercial responsibility.
To ensure successful MSTU external network port adaption, the port must be configured to be
self-negotiation.
Add connection configuration to the three shelves. You must configure rack2 shelf1 MSU and rack2 shelf 2
MSU to be connected. Otherwise, the medium planes of two medium shelves can't connect to each other.
101
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
102
Chapter 4 ZXUSS-Side Configuration
Click the Add button and select the two MSU numbers to be connected in MSU
number list and the to be connected MSU list.
Figure4.4-27 Module Share Resource Selection Sequence Configuration Entering the Interface
103
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
104
Chapter 4 ZXUSS-Side Configuration
For a modules backup modules, select all other cards in sequence. For example, for
module 1, its backup card in sequence is 2-3-4. For module 2, its backup card in sequence
is 3-4-1.
Configuration Specification
1 Capacity number: Configure as actual requirements. The capacity number must be less than the
maximum capacity number the USS CDN node is allowed to release. Its value must be no more than
system content capacity in module configuration. For Jiangsu province, configure 120,000 to the
content number.
2 Channel number: Configure as actual requirements. The channel number must be less than the
maximum channel number the USS CDN node is allowed to create.
105
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
3 Storage space: Configure according to disk configuration of the node. The storage space must be less
than the file space which the USS CDN node is allowed to create. Curretly, it mainly refers to VOD
content size and time shift recording partition size. Configure the maximum value that the interface
allows on site.
Configuration Specification
VCDN configuration complies with the rule that the total VCDN capacity cant be more
than the sum of the corresponding configurations in CDN.
1 Node number must keep consistent with the VCDN number in the CDN platform.
Refer to section 6.2.6.
2 Content number and channel number: Configure as actual requirements. The content
number must be less than the maximum content number the USS CDN node is allowed to
106
Chapter 4 ZXUSS-Side Configuration
release. The channel number must be less than the maximum channel number the USS
CDN node is allowed to create. For Jiangsu province, configure 120,000 to the content
number.
3 Storage space: Configure according to disk configuration of the node. The storage
space must be less than the file space which the USS VCDN node is allowed to create.
Curretly, it mainly refers to VOD content size and time shift recording partition size.
Configure the maximum value that the interface allows on site.
Note:
If USS contains multiple VCDN nodes, there must configure multiple records. Otherwise,
it can influence the content release or channel creation. For foreground CDN and VCDN,
there are three more fields with actual value: channel number, content number and usable
space. The value of the three fields are not 0, the record table cant be deleted.
Note:
If USS contains multiple VCDN nodes, there must configure multiple records.
107
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
For the remote server configuration of CDN-MANAGER, it must be consistent to the configuration of service
Manager/home/zxin10/etc/win_mgt.scr. Refer to section 6.1.1.
2 IP address: Configure the IP address the same to the floating IP address of the service CDN-Manger
network.
4 CO number and module number: Configure Manager module number and CO number to be the
module number and CO number.
108
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
Configure APP which connects with USS node or CP node. Generally, USS test environment is simple. So
APP and CDN-Manager can be configured together.
Configuration Specification
3 APP port number: 4999, it is the number calculated by CDN-MANAGER port number 1, meaning
that APP and CP connection starts with 4999 + 1.
109
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 Communication link ID: Currently, a communication link is created in CSU with CDN-MANAGER.
It is numbered 1.
2 MDU sub-system number and MDU sub-unit number: The MDU sub-unit number is configured to
be the signal sub-unit external port.
3 MLSS port number: It is the port number used to connect USS with MLSS. It can be configured by
any number in condition it is consistent with the port configured at MLSS side. In engineering
practice, configure 6000 to all USS nodes.
110
Chapter 4 ZXUSS-Side Configuration
4 MLSS module number: It is the module number used to connect with MLSS. It must be configured
to CSU module which is currently configured as the module 1.
5 MDU unit number and sub-unit number: It is determined by Figure Figure4.4-3 and Figure4.4-4 in
section 2.
Configuration Specification
3. MDU sub-system number and MDU sub-unit number: The MDU sub-unit number is
configured to be the signal sub-unit external port.
111
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
4. MLSS port number: It is the port number used to connect USS with APP. It can be
configured by any number in condition it is consistent with the port configured at APP side.
And it does not conflict with MLSS configuration.
Add a communication link according to Table 4.55-. Add first two communication links if there are two
modules. And add four links if there are four modules.
112
Chapter 4 ZXUSS-Side Configuration
Configuration Specification
1 MDU sub-system number and MDU sub-unit number: The MDU sub-unit number is configured to
be the signal sub-unit external port.
113
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 FTP Server user and FTP Server passward are both zxuss.
2 Bandwidth (Kbytes) of single-subscriber user-side: The bandwidth is the bandwidth allocated to one
subscriber. Bandwidth refers to the configuration value. As the bandwidth is larger, the speed is
faster and it occupies more resource. By default, it is 2 M.
3 Key: When the Key is transformed into binary numbers. The quantity of 1 must be the same to the
quantity of code characters.
Note:
This configuration is not completely used so far. When the main content is dropped down,
it must gain the bandwidth limit. Then when the USS is used as a server, this configuration
must specify MSTU user, password and maximum links.
114
Chapter 4 ZXUSS-Side Configuration
1Select DLSN parameter and click Modify. Then enter 1 in Parameter Value
column. The following Figure shows the configuration interface.
115
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
2Select SSBI parameter and click Modify. Then enter 40 in the Parameter Value column. The following
Figure shows the configuration interface.
116
Chapter 4 ZXUSS-Side Configuration
After the parameters are successfully modified, a table must be transmitted through EMS. And then
restart MSTUs one by one to activate these parameters.
117
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
1Select 1 in Module type list and select Specific module R_CONST table in the Command type field. Tick
both check boxes of Transmission type and click Send. Wait till the saving and synchronizing process over.
2Select 1 in Module type list and select Specific module variation relation table in the Command type field.
Tick both check boxes of Transmission type and click Send. Wait till the saving and synchronizing process
over.
Note:
Before a table is sent, the configurations described before section 4.6 must be
accomplished. We are not responsible for faulties caused by deregular operation.
118
Chapter 5 Version Configuration and Card
Start
Abstract
This chaptor describes the installation carried by the production line for the first time. For
other engineering occasions, the installation step sequence changes. And refer to section.0
first.
Copy version files to the directory /USS100/USS100 of the Platform server as listed in Table 5.1-1.There are
23 files in total.
The version files to be uploaded are 23 files in total including both Linux and KLinux files. The main files are
listed below:
- FPGA version
- Watchdog version
- 85xx version
- Xscal version
120
Chapter 5 Version Configuration and Card Start
FPGA ZXUSS_MSCU-080101-FPGA_04_H.rbf
target_hardware\FPGA
Boot MSCU_Boot_H.exe
Boot\Linux_Boot\MSCU
Boot MSTU_Boot_bigsmp_H.exe
Boot\Linux_Boot\MSTU\bigsmp
reinforcement script mstu_script_bigsmp_h
Boot\Linux_Boot\MSTU\bigsmp
MSTUB( MSTUB CPU KLINUX_USS_MSTU_MSTU_X86_V1.0
KLinux) (KLinux) USS\Release\MSTU\bigsmp 0.04.01U01_H.USS
121
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
WatchDog Klinux_zmsscmd_h
USS\Release\MSTU\WatchDog
Streaming media version R_KLINUX_ZMSS_H.rpm
(target_hardware\KLINUX_ZMSS)
File system library version KLINUX_USS_MSTU_LIBFS.so
(target_hardware\Lib) KLINUX_USS_MSTU_LIBIPC.so
Boot klinux_boot_h
(Boot\KLinux_Boot\MSTU)
Boot KLINUX_MSTU_Boot_bigsmp_H.exe
(Boot\Linux_Boot\MSTU\bigsmp)
Operation system version OS_KLINUX_USS_MSTU_MSTU_V1.00.
(USS\Release\MSTU\klinux) 04.01U01_H
122
Chapter 5 Version Configuration and Card Start
Select all of the versions in the left version list and click >> button to release them to the
Version downloading process table.
123
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
124
Chapter 5 Version Configuration and Card Start
Select slot 9 and 10 and CPU 1 (no matte it is online or not) by entering corresponding
number as shown in the following Figure.
125
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Select slot 9 and 10 and CPU 1 (no matte it is online or not) by entering corresponding
number as shown in the following Figure.
Configuration Specification
1 Rack number and shelf number: Enter numbers according to actual configuration. The shelf refers to
the control shelf.
2 Slot number: Enter the slot number where SOMP card locates.
126
Chapter 5 Version Configuration and Card Start
Select slot 9 and 10 and CPU 1 (they must be online) by entering corresponding number as shown in the
following Figure.
127
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 Rack number and shelf number: Enter numbers according to actual configuration. The shelf refers to
the control shelf.
2 Slot number: Enter the slot number where SOMP card locates.
Select Preview and then select all versions. Click >> to release these versions as shown in
the following Figure.
128
Chapter 5 Version Configuration and Card Start
Click the Execute a batch of commands button and wait because the whole process takes
time. When the process is over, a success message prompts up.
Note : After successful version setting, reboot simuteneously the active and standby OMP.
After OMP reboot (it usually takes 15 minutes), transmit all relation tables of module 1
and implement further operation. In addtion, after OMP reboot, NE OMP address changes
to the global property configuraiton - Basic property - IP address. If this IP address is
previously modified, the corresponding BoardIP in background 129 directory
/zxmsg/CommCfg.ini and IPAddr value in file /zxmsg/IpAddrs.cfg. Use new OMP 129
address to create a NE in EMS.
129
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
5.6.1 MSU
6 Log in MSU through Telnet and enter i to check the starting process.
7 MSU can start normally after it gets versions from OMP. If fault occurs, start again and again till it
is normal.
1 Accomplish the logic resource allocation in EMS data configuration. The configuration must be
implemented, logic resource configuration physical connection configuration
2 Data transmission method The tables arrive to the forground and activate the configuration data.
Note:
2 In case MSU card poweron error, carry out command PING in OMP to verify if MSU
of the shelf is connected. Ensure the normal operation of cross-shelf control plane
5.6.2 MDU
1 Reset MDU in rack chart.
3 Check if MDU 128 network segment and external port are properly connected by command PING.
5.6.3 MSCU
4 Connect to MSCU through SSH from a card or server with a port number, 22222, user
name/password, zxiptv/ZTE@uss100.
MSTU with reinforced version 04.01 uses remote SSH to log in with user name/password, sshd/ZTE@uss100.
2 After login, check if the three hard disks have been formatted and partitioned.
# cat /proc/partitions
8 0 156290904 sda
131
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
8 1 136521 sda1
8 2 2104515 sda2
8 3 154039252 sda3
8 16 732574584 sdb
8 17 732572001 sdb1
8 32 732574584 sdc
8 33 732572001 sdc1
8 48 732574584 sdd
8 49 732572001 sdd1
In case of difference from the above display, implement partition and format operations according to the
following description.
# cat /proc/partitions
8 0 156290904 sda
8 1 136521 sda1
8 2 2104515 sda2
8 3 154039252 sda3
8 16 732574584 sdb
8 32 732574584 sdc
8 48 732574584 sdd
The above informaton tells us that sdb, sdc and sdd are the three hard disks connected
to MSTU.
# fdisk /dev/sdb
There is nothing wrong with that, but this is larger than 1024,
Command action
e extended
WARNING: Re-reading the partition table failed with error 16: Device or resource busy.
Syncing disks.
Repeat the above operation for sdc and sdd one by one.
# cat /proc/partitions
8 0 156290904 sda
8 1 136521 sda1
8 2 2104515 sda2
8 3 154039252 sda3
8 16 732574584 sdb
8 17 732572001 sdb1
8 32 732574584 sdc
8 33 732572001 sdc1
8 48 732574584 sdd
8 49 732572001 sdd1
133
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
= sectsz=512
Format hard disks sdb, sdc and sdd in turn. Check if the format is successful by
executing the following commands.
# ps ef | grep ZMSS
# ftp 127.0.0.1
Both user name and password are iptv. Check if FTP function is OK.
134
Chapter 6 IPTV Service-Side Configuration
6.1 CP Configuration Files
[general]
isappserver=1
ntserver=129
jfserver=129
bindip=1
ommmp=2
modulecount=0
Note:
6.1.2.1 CDNM
[GENERAL]
CDNProxyActive=0
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
RGMActive=0
DRMActive=0
DLSActive=0
LCSActive=0
[NODEINFO]
CDNpost = 129
CMSpost = 129
OSSpost = 129
SLPpost = 129
CPMpost = 129
;-------------------------------------------------------------------------------------------------
[CDN]
;common
TcpThreadNum= 3
RtspThreadNum=0
TcpThreadSleepTime=20
RtspThreadSleepTime=30
;-----------------
136
Chapter 6 IPTV Service-Side Configurationt
Mode=3 ;0:
none,1:manager,2:agent,3:manager+agent,4:livecast
[GENERAL]
CDNProxyActive=0
RGMActive=0
DRMActive=0
DLSActive=0
LCSActive=0
[CP]
DeviceType = 5
DeviceID =1
137
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Note:
Use 1 for CPMgr independent deployment. If CPAgent is started, x.c terminal number in
zxin10.ini must be configured.
Configuration Specification
2 Enter node name, bandwidth threshold, storage threshold and cocurrency threshold according to
physical configuration.
3 Node weight: 1
138
Chapter 6 IPTV Service-Side Configurationt
Configuration Specification
2 Agent name and IP: Consistent with the SCP IP configured in CDN-MANAGER win_mgt.ini file.
4 Module number and CO number: Input CDN-Manager module number and CO number.
Configuration Specification
2 USS unit IP address and USS unit signal IP address: Enter the MDU signal IP addrss.
4 USS unit logic space limit: 750*3*0.8*n/2, n refers to the MSTU card number.
5 USS unit logic cocurrency stream limit: 400*n, n refers to the MSTU card number.
After a ZXUSS node POP unit is added, get the unit ID and add it to the USS global
configuration as shown in Figure Figure4.1-53.
140
Chapter 6 IPTV Service-Side Configurationt
Configuration Specification
1 Node name and POP unit name: Select the same one as used in section 6.2.1 and 6.2.3.
4 CO number: Be consistent with the number set in section 4.1.1 and associates with 6.1.1
configuration file. The CO number is unique and starts with 1. Make a good plan beforhand as the
number increases.
141
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 Node name and POP unit name: Select the same one as used in section 6.2.1 and 6.2.3.
2 FTP address: Enter an any MSTU external network IP address of this USS node.
3 FTP port: 21
For pilot commissions, ensure VCDN number is consistent with the service operators ID.
Both are digits.
142
Chapter 6 IPTV Service-Side Configurationt
Ensure the VCDN number is the same to USS-side configuration. For reference, see 4.4.6.
Configuration Specification
1 VCDN name and node name: Configure according to configurations in section 6.2.5 and 6.2.1.
143
Chapter 7 Maintenance After Configuration
7.1 Remote Management
In engineering, the ZXUSS CO-side 129 is installed together with EMS. Start USS remote maintennace and
manage operations through remote EMS for after-configuraiton maintenance.
Configuration Specification
1 Maintenance IP address 1: Set SOMP remote IP. Usually, it is a public network IP.
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
2 Maintenance IP address 1 mask code: Set SOMP remote maintenance address mask code.
Configuration Specification
1 Destination IP: Remote maintenance EMS IP address. Usually, it is a public network floating IP of
the service dual-standby EMS.
2 Destination mask: It is determinded by the remote maintenance EMS and can be reached by the
router.
146
Chapter 7 Maintenance After Configuration
Configuration Specification
3 User name and password: admin, which is the default configuration of NE management, irrelated to
EMS Client user name and password, admin.
147
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
1 IP1: Enter management USS node SOMP remote maintenance IP taking reference of Figure7.1-2.
3 EMP module number: 157, which ranges from 144 to 254. For SOMPs of one USS node, the EMP
module number cant conflict over one network. Previously, the local USS SOMP module is
numberd 156. For one newly added remote maintenance EMS and a NE, the EMP is numbered 157
and so on.
148
Chapter 7 Maintenance After Configuration
Check specification:
If the addtion is a success, the NE script number is not null, link status is Normal link and link token is valued
by digits but not -1.
After the addition, it supports adding global USS nodes in one remote maintenance EMS and implementing
unified management.
# vi /etc/ntp.conf
#This Client source is taken as an unbelievable network field unless the Client is
autheticated.
149
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
restrict 127.0.0.1
##############################################################
#Enable the active equipment IP too. For SCP, enter active equipment network card
IP and floating IP at the active equipment and enter standby equipment network card IP
and floating IP at the standby equipment.
restrict 10.17.0.11
restrict 10.17.0.13
##############################################################
#Configure all agents including the added new ones. Add related configurations for
new agents.
#AGENT configuration uses the active equipment address with the mask address
255.255.255.255. It is prohibited to use network segment method.
#Marginal node 1
150
Chapter 7 Maintenance After Configuration
#Marginal node 2
#...
#Marginal node N
#Configure Manager visit time server here. Normally it refers to the Internet time
server or other specified server.
#In this example, we use the Internet time server as the synchronization clock source.
#time.nist.gov
#time.windows.com
server 0.pool.ntp.org
server 1.pool.ntp.org
server 2.pool.ntp.org
#Here configure Manager time server can visit Manager. Otherwise, the time can't be
synchronized.
# /etc/init.d/ntpd restartturbo
# /etc/init.d/xntpd restartsuse
151
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Configuration Specification
5 For backup server IP and the second backup server IP, enter the default 0.0.0.0 if they are not
configured. For backup port number and the second backup port number , enter the default 0 if they
are not configured. It is prohibited to use the IP address the same to the server IP.
152
Chapter 7 Maintenance After Configuration
NTP networking is architecture by multiple levels. USS can be the NTP Server of the
lower level node. In such an occasion, it is necessary to configure the marginal NTP as
shown in Figure7.2-3.
After NTP configuration, check if NTP signal message can be captured by monitoring in
NTP Server. If NTP signal can be captured, that indicates NTP configuration a success. At
USS side, a few minutes wait is needed. Then log in SOMP or MSTU to check time.
153
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
The following lists the advantages of the command line and terminals:
1 When EMS picture interface does not work due to version error, the operation can be implememted
by command line and terminals.
154
Chapter 7 Maintenance After Configuration
2 Some specific functions cant be accomplished in the man-machine interface but can be
accomplished by command line. For example, carry out the command line GET_MPTABLE_LIST
to get all foreground tables.
7.3.2 Probe
The functions of probe is to check the foreground database content and foreground equipment status.
USS1 database management has different data resources including USS node descriptive data, file system data,
USS node internal data, service related data and CDN load balance and resource selection machinism data.
1 Rack, shelf, card and CPU configuration table, type table and data table.
Content allocation table R_CDNCAP describes USS node CDN quota information, mainly related to content
service operations. As to protocol, it is managed by CSU. So the table does not contain modules. The reason to
list the occupation and statistics information such as current content and channel in this table is because the
information must be saved as static data and must be differed from the dynamic statistics information such as
the subscriber concurrency stream and bandwidth.
Use this table to check the rest unoccupied space when channel creation failure occurs because of inadequate
storage space.
156
Chapter 7 Maintenance After Configuration
This table is used to check VCDN which a program belongs to. Sometimes, VOD and live broadcast failure is
caused by the corresponding VCDN not able to be found. In addition, SDP description can check if the
corresponding MDU media port resource is configured or not.
R_STREAM describes the resource number occupied by each stream. The information can gained through the
resource type one applies. It records the resource occupation information according to the database stream
record. When the information is released, no judgement based on service type is needed. At the same time, the
Index can be used as the service and MSTU data field ID.
157
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
rescpu DWORD CPU capacity occupied this time (not configured for dynamic field on the
background)
resfileio DWORD File system IO capacity occupied this time (not configured for dynamic field
on the background)
resinrev DWORD Internal port input bandwidth occupied this time (not configured for dynamic
field on the background)
resinsend DWORD Internal port output bandwidth occupied this time (not configured for
dynamic field on the background)
resextrev DWORD External port input bandwidth occupied this time (not configured for
dynamic field on the background)
resextsend DWORD External port output bandwidth occupied this time (not configured for
dynamic field on the background)
isvod DBBOOL
R_STREAM table is used to check the circuit status, which can also be checked by watching the physical
circuit status.
Sub-unit relation table is controlled by such physical devices as the card, DSP and PCM. For a platform,
physical devices also include the unit CPU sub-card. The sub-unit describes their logic information. For the
platform hardware, the CPU sub-unit is numberd from 1 to 8. For other sub-units, they are numbered with 9 as
a starting.
158
Chapter 7 Maintenance After Configuration
This table is used to check status. MSTU number 16 sub-unit is streaming media, which can be checked by
checking the sub-unit table.
Sub-unit attachment relation table is controlled by such physical devices as the card, DSP and PCM. For a
platform, physical devices also include the unit CPU sub-card. The sub-unit describes their logic information.
For the platform hardware, the CPU sub-unit is numberd from 1 to 8. For other sub-units, they are numbered
with 9 as a starting. For the access J10 module, the sub-unit number begins with 1.
159
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
This table is used to check if the external port IP address is configured or not.
This table is used to check such information as isalarm, filesysused, serused and ftpused.
In Restype, 1 refers to CPU, 2 to FTPIO, 3, 4, 5 and 6 respectively corresponding to
internal and external output and input. If there is not content released but still there is FTP
resource occupied, that means problem. The solution is to restart SOMP.
Signal tracing is used to check signals and protocols. The RTSP tracing and WINTCP
tracing are frequently used as shown in Figure Figure7.3-3 and Figure7.3-4.
160
Chapter 7 Maintenance After Configuration
161
ZXUSS VS8000C (V1.0) Multimedia Server System Installation Debug Manual
Diagnosis test is to test communication of the units in the media server module, to check if
server system hardware works properly, to ensure timely fault location and troubleshooting
and the server's normal operation.
Diagnosis test can implement timely test, routine test and execution of a batch of
commands.
This test is often used to timely locate communication fault in the installation system or
when a communication fault is detected. For example, for the internal communication test
between cards, use card diagnosis test or between-card diagnosis test; for card external
port communication, use external stream test to check if the external port is reachable and
its communication status.
162