Beruflich Dokumente
Kultur Dokumente
backwater valve.
EN 13564
2
The new Staux.
We have made the impossible
possible and made the original
Staufix backwater valve even
better.
3
The new original
at a glance.
4
Guara
ntee
Decad
es-
rts
l on
pa
av
a re
g
Removable two-way ail
abi
lity gu for
sp
a ra n t e e
socket.
More information on the removable and individ-
ually combinable two-way socket is provided on
page 7.
We assist you with a comprehensive service
offer from choosing the right product to
installation and maintenance through to our
KESSEL guarantee. This guarantees that
spare parts for the Staux product range
are available at any time and for decades
to come.
5
Installation set for
the concrete slab. Flexibly installable.
The new installation set is available with
three different telescopic extension sec-
tions and can thus be exibly installed at
all depths. A standard extension section,
Installation even more convenient. with ange and counter ange made of
stainless steel and elastomer waterproof-
ing membrane for deeper installation
in waterproof concrete are available to
choose from.
Black or tileable.
The new Staux is available with two different
covers. The upper section with a black cover ts
seamlessly into the oor. The upper section with
the grey cover can be covered with tiles.
6
Removable
two-way socket. Individually
combinable.
The sockets and spigots are available
with the same sizes or different inlet and
Drain body
125 - 200
200
160
125
Drain body
110
110
100
Removable.
The new two-way sockets are removable and
therefore make installation of the Staux easier
and faster than ever before.
7
Staux Control
with alarm.
Backwater protection even smarter.
Staux Control.
The new Staux Control is particularly smart.
It is equipped with an audible alarm, which emits
a visual and an acoustic warning signal in the
event of backwater. This means that home owners
are in full control and always know what is
happening in the basement.
8
Upgradable.
The new Staux can also be upgraded to the
new Staux Control by adding the lockable
Control cover (with radio-based audible alarm).
Functions.
Standard: Radio-based audible alarm in
the Staux Control for visual and acoustic
warning signal.
Optional: Additional radio-based audible
alarm for visual and acoustic warning in
the living area.
Optional: Radio receiver as switched socket
in the event of backwater, for example
a switched on washing machine is automat-
ically disconnected from the mains.
Backwater level
9
The complete Staux
product range.
10
Staufix backwater valves
for wastewater Available from mid-2017
Staufix Control twin flap backwater valve (with visual and acoustic warning)
Outer diameter
Illustration Article description Art. No.
( in mm)
Staufix Control twin flap backwater valve 100 770 090.10X
made of polymer 110 770 100.10X
With emergency closure, 125 770 125.10X
for wastewater 160 770 150.10X
with visual and acoustic warning in the 200* 770 200.10X
event of backwater
Installation in the concrete slab 100 770 090.10S
tileable cover (X), Class A 15 110 770 100.10S
black cover (S), Class A 15 125 770 125.10S
380 tileable cover (XR), Class A 15, one stain- 160 770 150.10S
less steel flap as rat protection 200* 770 200.10S
max. 170
min. 47
EN 13564 Type 2
Staufix Control twin flap backwater valve (with visual and acoustic warning)
Outer diameter
Illustration Article description Art. No.
( in mm)
Staufix Control twin flap backwater valve 100 770 090
made of polymer 110 770 100
With emergency closure, 125 770 125
for wastewater 160 770 150
with visual and acoustic warning in the event 200* 770 200
of backwater
Installation in an exposed drainage pipe 100 770 090R
with two polymer flaps 110 770 100R
with one polymer flap and one stainless 125 770 125R
AxB
steel flap as rat protection (Version R) 160 770 150R
200* 770 200R
H
EN 13564 Type 2
Staufix
Artikelabbildung
twin flap backwater valve (can be retrofitted on Staufix Control)
Outer diameter
Illustration Article description Art. No.
( in mm)
Staufix twin flap backwater valve 100 730 090.10X
made of polymer 110 730 100.10X
With emergency closure, 125 730 125.10X
for wastewater 160 730 150.10X
can be retrotted on the Staux Control 200* 730 200.10X
EN 13564 Type 2
EN 13564 Type 2
min. 47
179
40
30
355 355
136
40
197
209
337
130
130
196
130
330 330 330
for deeper installation for deeper installation with flange for installation in waterproof
incl. sealing, max. extension: 147 mm with flange and mating flange made of stain- concrete
suitable for installation in the concrete slab/ less steel for connection to an on-site mem- incl. sealing set, consisting of:
floor. brane incl. sealing, max. extension: 147 mm Counter flange made of stainless steel, incl.
screws
In case of deeper installation ensure mainte- In case of deeper installation ensure mainte- Elastomer waterproofing membrane made of
nance capability! nance capability! NK/SBR 700 mm max. extension: 294 mm.
Completely assembled.
Art.No. 830 070 Art.No. 830 073
Suitable for systems for installation in a
concrete slab/floor
Spigot Socket
removable fitting mountable on both sides and in different dimensions removable fitting mountable on both sides and in different dimensions
for exposed drainage pipe for installation in a concrete slab Staufix twin flap backwater valve
Staufix twin flap backwater valve
with black cover with tileable cover
100 - 110 Art.No. 730 000.10 100 - 110 Art.No. 730 000.10S 100 - 110 Art.No. 730 000.10X
125 - 200* Art.No. 730 000.15 125 - 200* Art.No. 730 000.15S 125 - 200* Art.No. 730 000.15X
Accessories Staufix
Outer diameter
Illustration Article description Art. No.
( in mm)
Radio-based audible alarm 72 222
for forwarding a visual and acoustic signal in the
event of backwater, suitable for the Staufix Control
16 SDF