In-situ data for wastewater sample.

The mean data of pH, dissolved oxygen (DO), conductivity, and temperature has been
recorded. Based on the results, the readings of pH, dissolved oxygen (DO), conductivity, and
temperature depends on the type of samples has been taken.
Based on the mean pH reading on every samples, the higher reading recorded are at the
influent state with pH 8.73. Followed by effluent sample with pH of 8.51 and aeration tank
which is 7.68. Besides, Clarifier recorded the lowest reading compared to the other sample
with pH value of 1.45.
For the mean of dissolve oxygen (DO) data, the influent sample recorded the lowest
reading (0.09 mg/L) and the clarifier sample are the highest with mean value of 7.69 mg/L.
However, the mean dissolve oxygen (DO) data of aeration tank and effluent are 4.64 mg/L
and 3.13 mg/L respectively.
At the same time, the mean conductivity for each sample are not consistence. As we can
see at the table 6.2 s/cm , the greater value are at the effluent (527.33 s/cm ), and
lowest mean conductivity data recorded at clarifier because of a few reasons that will be
discuss at the discussion part.
Lastly, focus to the mean temperature of the sample, the mean different are not too far
which is only 1.0. For influent, aeration tank, clarifier and effluent, the mean temperature
recorded are 28.87 C , 28.31 C , 28.52 C , 27.20 C respectively. We can say
that the temperature of each samples are almost constant at every stage.