TECHNICAL DATA
Operating range: from 0,4 - 4,2 m3/h with head of up to 8 metres.
Pumped liquid temperature range: from -10C to +110C.
Working pressure: 10 bar (1000 kPa).
Protection class: IP X4.
Insulation class: F.
Installation: with horizontal motor axis.
Standard power input: single-phase 1 x 230 V / 50/60 Hz.
Pumped liquid: Clean, free of solids and mineral oils, non-viscous,
chemically neutral, with properties similar to water (glycol max 30%).
Special versions on requests: alternative voltages and/or frequencies.
Low energy consumption electronic pump for water circulation in pressurised closed circuit, or open circulation type, domestic heating and air conditioning
systems.
ADVANTAGES
Thanks to the advanced technology employed, the permanent magnet synchronous motor, and the frequency converter, the new range of EVOTRON
circulators ensures high efficiency in all applications, with significant benefits in terms of energy saving. For this reason, all the new range of EVOTRON
circulators belongs to European Directive ErP 2009/125/CE. The circulator has a built-in electronic device that detects the changes demanded by the system
and automatically adapts the circulator performance accordingly, always ensuring optimum efficiency and minimum energy consumption.
Easy operation and easy to read control panel, with the display always showing the mode of operation selected.
The EVOTRON circulator can operate in three different control modes:
Possibility of economy regime operation (automatic night-time reduction, SMART SLEEP function).
Supplied as standard with electric connector for quick connection to the electric power network.
Insulation casing supplied as standard for all the range.
CONSTRUCTION FEATURES
Single body consisting of the cast iron hydraulic section, and the wet rotor motor.
Die-cast aluminium motor casing. Technopolymer impeller.
Ceramic motor shaft on graphite bushings lubricated by the pumped liquid.
Stainless steel rotor liner, stator liner and closing flange.
Ceramic thrust ring, ethylene-polypropylene seal ring and brass bleed cap. The wet rotor synchronous two-pole motor is controlled by a frequency converter, and
does not require overload protection.
6
EVOTRON
WET ROTOR ELECTRONIC CIRCULATORS
N. PARTS MATERIALS
4 IMPELLER ULTRASON
7B ROTOR MAGNET
8 STATOR -
7
EVOTRON
WET ROTOR ELECTRONIC CIRCULATORS
WET ROTOR ELECTRONIC CIRCULATORS
PERFORMANCE RANGE
The performance curves are based on kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
0,5 1 2 3 5 10 20 30 Q US gpm
50
5
EVOTRON 60/130
40
4
30 3 10
20 2
EVOTRON 40/130
10 1
0,1 0,2 0,3 0,4 0,5 0,8 1 2 3 4 5 6 7 8 10 Q m3/h
0,1 0,5 1 2 3 Q l/s
2 3 4 5 10 20 30 40 50 100 Q l/min
8
EVOTRON - ELECTRONIC CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS - SINGLE, WITH UNIONS
Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H (kPa)
0 2 4 6 8 10 12 Q US gpm
H (m)
H (ft)
0 2 4 6 8 10 Q IMP gpm
45 4,5
14
40 4
12
35 3,5
L2
30 3 10
Ma
x
25 2,5
L1
8
L
20 2
6
15 1,5
4
10 1
5 0,5 2
Min
0 0 0
0 0,5 1,0 1,5 2,0 2,5 3,0 Q (m3/h)
H
0 0.2 0.4 0.6 0.8 Q l/sec
H1 0 10 20 30 40 50 Q l/min
0 2 4 6 8 10 12 Q US gpm
0 2 4 6 8 10 Q IMP gpm
30
25
20
P (W)
15
10
5
Min
0
0 0,5 1,0 1,5 2,0 2,5 3,0 Q (m3/h)
0 0.2 0.4 0.6 0.8 Q l/sec
0 10 20 30 40 50 Q l/min
* The parameter of reference for the more efficient circulators is EEI 0,20.
EVOTRON 40/130 1/2" 130 158 79.5 147.5 53 140 85 1/2 148 193 217 3,0
EVOTRON 40/130 130 158 79.5 147.5 53 140 85 11/2 148 193 217 3,2
EVOTRON 40/180 180 158 79.5 147.5 53 140 85 11/2 148 193 217 3,3
EVOTRON 40/180 X 180 158 79.5 147.5 53 140 85 2 148 193 217 3,4
9
EVOTRON - ELECTRONIC CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS - SINGLE, WITH UNIONS
Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
WET ROTOR ELECTRONIC CIRCULATORS
B1 B
0 2 4 6 8 10 12 14 16 Q US gpm
H (kPa)
H (m)
0 2 4 6 8 10 12 14 Q IMP gpm
H
ft
60 6 20
L2
50 5
Ma 16
x
40 4
L1
L
12
30 3
8
20 2
10 1 4
Min
0 0 0
0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 Q mh
H 0 0.2 0.4 0.6 0.8 1.0 Q l/sec
0 10 20 30 40 50 60 Q l/min
H1
0 2 4 6 8 10 12 14 16 Q US gpm
0 2 4 6 8 10 12 14 Q IMP gpm
50
45
40
35
30
P (W)
25
20
15
10
5
0 Min
0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 Q mh
0 0.2 0.4 0.6 0.8 1.0 Q l/sec
0 10 20 30 40 50 60 Q l/min
* The parameter of reference for the more efficient circulators is EEI 0,20.
EVOTRON 60/130 1/2" 130 158 79.5 147.5 53 140 85 1/2 148 193 217 3,0
EVOTRON 60/130 130 158 79.5 147.5 53 140 85 11/2 148 193 217 3,2
EVOTRON 60/180 180 158 79.5 147.5 53 140 85 11/2 148 193 217 3,3
EVOTRON 60/180 X 180 158 79.5 147.5 53 140 85 2 148 193 217 3,4
10
EVOTRON - ELECTRONIC CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS - SINGLE, WITH UNIONS
Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H (kPa)
H (m)
0 2 4 6 8 10 12 14 16 Q IMP gpm
H
80 8 ft
24
70 7
Ma
x
L2
60 6 20
50 5 16
L1
40 4
L
12
30 3
8
20 2
4
10 1
Min
0 0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Q mh
0 0.2 0.4 0.6 0.8 1.0 1.2 Q l/sec
H Q l/min
0 10 20 30 40 50 60 70
H1
0 2 4 6 8 10 12 14 16 18 Q US gpm
0 2 4 6 8 10 12 14 16 Q IMP gpm
80
70
60
50
P (W)
40
30
20
10
0 Min
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Q mh
0 0.2 0.4 0.6 0.8 1.0 1.2 Q l/sec
0 10 20 30 40 50 60 70 Q l/min
* The parameter of reference for the more efficient circulators is EEI 0,20.
EVOTRON 80/130 1/2" 130 158 79.5 147.5 53 140 85 1/2 148 193 217 3,0
EVOTRON 80/130 130 158 79.5 147.5 53 140 85 11/2 148 193 217 3,2
EVOTRON 80/180 180 158 79.5 147.5 53 140 85 11/2 148 193 217 3,3
EVOTRON 80/180 X 180 158 79.5 147.5 53 140 85 2 148 193 217 3,4