Sie sind auf Seite 1von 4

The Spot Free Car Wash Solution.

The Professional
Car Wash Operator
Now Has a Choice...
Spot Free Systems
Models BT-1800 CT-4000 CT-7000 DT-10000 JT-2000 JT-4000
Design
Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass
Feed Water Source (ppm)*** TDS < 2,000 TDS < 2,000 TDS < 2,000 TDS < 2,000 TDS < 2,000 TDS < 2,000
Standard Recovery Rate 41% 48% 62% 55% 31% 48%
Recovery with Concentrate Recycle Up to 75% Up to 75% Up to 75% Up to 75% Up to 75% Up to 75%
Rejection and Flow Rates
Nominal Salt Rejection 98.5% 98.5% 98.5% 98.5% 98.5% 98.5%
Permeate Flow* (gpm / lpm) 1.25 / 4.73 2.78 / 10.52 4.86 / 18.40 6.94 / 26.27 1.38 / 5.22 2.78 / 10.52
Minimum Feed Flow (gpm / lpm) 4.25 / 16.10 5.78 / 21.00 7.86 / 29.80 12.94 / 49.00 4.38 / 16.56 5.78 / 21.00
Maximum Feed Flow (gpm / lpm) 14.00 / 53.00 14.00 / 53.00 14.00 / 53.00 28.00 / 106.00 14.00 / 53.00 14.00 / 53.00
Minimum Concentrate Flow (gpm / lpm) 3.00 / 11.36 3.00 / 11.36 3.00 / 11.36 6.00 / 22.71 3.00 / 11.36 3.00 / 11.36
Connections
Feed (in) 1 FNPT 1 FNPT 1 FNPT 2 FNPT 1 FNPT 1 FNPT
Permeate (in) 3/8 TUBE 1 FNPT 1 FNPT 1 FNPT 1/2 FNPT 1/2 FNPT
Concentrate (in) 3/8 TUBE 1 FNPT 1 FNPT 1 FNPT 1/2 FNPT 1/2 FNPT
Membranes
Membranes Per Vessel 1 1 1 1 1 1
Membrane Quantity 1 2 4 6 1 2
Membrane Size 4040 4040 4040 4040 4040 4040
Vessels
Vessel Array 1 1:1 1:1:1:1 2:2:2 1 1:1
Vessel Quantity 1 2 4 6 1 2
Pumps
Rotary Vane 1001
Pump Type Multi-Stage Multi-Stage Multi-Stage Multi-Stage Multi-Stage
Brass or 1011 SS
Motor HP (kw) 3/4 1.5 1.5 3 1.5 1.5
RPM @ 60/50Hz 1725 / 1465 3450 / 2900 3450 / 2900 3450 / 2900 3450 / 2900 3450 / 2900
Electrical
Standard Voltage 110V, 60Hz, 1Ph, 11.0A 220V, 60Hz, 1Ph, 8.3A 220V, 60Hz, 1Ph, 8.3A 220V, 60Hz, 1Ph, 16.0A 220V, 60Hz, 1Ph, 8.3A 220V, 60Hz, 1Ph, 8.3A

220V, 50Hz, 1Ph, 8.9A 220V, 50Hz, 1Ph, 8.9A 220V, 50Hz, 1Ph, 17.0A 220V, 50Hz, 1Ph, 8.9A 220V, 50Hz, 1Ph, 8.9A
220V, 60Hz, 3Ph, 5.1A 220V, 60Hz, 3Ph, 5.1A 220V, 60Hz, 3Ph, 18.1A 220V, 60Hz, 3Ph, 5.1A 220V, 60Hz, 3Ph, 5.1A
220V, 60Hz, 1Ph, 5.6A
Voltage Options 220V, 50Hz, 1Ph, 5.6A
220V, 50Hz, 3Ph, 6.1A 220V, 50Hz, 3Ph, 6.1A 220V, 50Hz, 3Ph, 19.1A 220V, 50Hz, 3Ph, 6.1A 220V, 50Hz, 3Ph, 6.1A
380V, 50Hz, 3Ph, 4.5A 380V, 50Hz, 3Ph, 4.5A 380V, 50Hz, 1Ph, 5.3A 380V, 50Hz, 3Ph, 4.5A 380V, 50Hz, 3Ph, 4.5A
460V, 60Hz, 3Ph, 3.5A 460V, 60Hz, 3Ph, 3.5A 460V, 60Hz, 3Ph, 4.6A 460V, 60Hz, 3Ph, 3.5A 460V, 60Hz, 3Ph, 3.5A

System Dimensions**
19 x 23 x 46 / 30 x 38 x 47 / 30 x 38 x 47 / 49 x 33 x 54 / 12 x 48 x 49 / 12 x 48 x 49 /
L x W x H (in / cm)
48 x 58 x 116 76 x 86 x 119 76 x 86 x 119 125 x 84 x 137 30 x 122 x 124 30 x 122 x 124
Weight (lb / kg) 105 / 47.63 235 / 107 265 / 120 350 / 159 150 / 68 175 / 79
* Product flow and recovery rates are based on equipment test parameters.
** Does not include operating space requirements.
*** Treatment ability of the RO system is dependent on feed water quality. Performance projections must be run for each installation.

Operating Limits
Maximum Feed Temperature (F / C) 85 / 29 Maximum Free Chlorine (ppm) 0
Minimum Feed Temperature (F / C) 40 / 4.4 Maximum TDS (ppm) 2,000
Maximum Ambient Temperature (F / C) 120 / 48.9 Maximum Hardness (gpg) 0
Minimum Ambient Temperature (F / C) 40 / 4.4 Maximum pH - Continuous 11
Maximum Feed Pressure (psi / bar) 85 / 5.9 Minimum pH - Continuous 5
Minimum Feed Pressure (psi / bar) 45 / 3.1 Maximum pH - Cleaning 30 Min. 12
Maximum Pressure (psi / bar) 150 / 10.34 Minimum pH - Cleaning 30 Min. 2
Maximum SDI Rating (SDI) <3 Maximum Turbidity (NTU) 1
Test Parameters: 550 TDS Filtered (5 Micron), De-Chlorinated, Feed Water, 65 psi (4.5 bar) Feed Pressure, 100 psi (6.89 bar) Operating Pressure, 77 Degrees F (25 Degrees
C), Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.
Low temperatures and high feed water TDS levels will significantly affect the systems production capabilities. Computer projections should berun for individual applications
which do not meet or exceed minimum and maximum operating limits.
Scale prevention measures must be taken to prolong membrane life.
BT-1800 CT-4000 CT-7000
Provides water for Provides water for provides water for
180 - 360 Cars/Day* 400 - 800 Cars/Day* 700 - 1400 Cars/Day*
1,800 Gallons per Day 4,000 Gallons per Day 7,000 Gallons per Day

High Recovery Rates = Less Waste Water High Recovery Rates = Less Waste Water High Recovery Rates = Less Waste Water

Nominal Salt Rejection: 98.5% Nominal Salt Rejection: 98.5% Nominal Salt Rejection: 98.5%

Carbon Pre-Filter: 1.5 Cubic Feet Carbon Pre-Filter: 2.0 Cubic Feet Carbon Pre-Filter: 2.5 Cubic Feet

Water Softener: 2.0 Cubic Feet Water Softener: 2.5 Cubic Feet Water Softener: 3.0 Cubic Feet

Atmospheric Tank: 300 Gallon Atmospheric Tank: 500 Gallon Atmospheric Tank: 750 Gallon

Re-Pressurization Pump: 3/4 HP Re-Pressurization Pump: 3/4 HP Re-Pressurization Pump: 1 HP

DT-10000 JT-2000 JT-4000


Provides water for Provides water for Provides water for
1,000 - 2,000 Cars/Day* 200 - 400 Cars/Day* 400 - 800 Cars/Day*
10,000 Gallons per Day 2,000 Gallons per Day 4,000 Gallons per Day

High Recovery Rates = Less Waste Water High Recovery Rates = Less Waste Water High Recovery Rates = Less Waste Water

Nominal Salt Rejection: 98.5% Nominal Salt Rejection: 98.5% Nominal Salt Rejection: 98.5%

Carbon Pre-Filter: 3.0 Cubic Feet Carbon Pre-Filter: 2.0 Cubic Feet Carbon Pre-Filter: 2.0 Cubic Feet

Water Softener: 4.0 Cubic Feet Water Softener: 2.5 Cubic Feet Water Softener: 2.5 Cubic Feet

Atmospheric Tank: 1000 Gallon Atmospheric Tank: 300 Gallon Atmospheric Tank: 500 Gallon

Re-Pressurization Pump: 1 HP Re-Pressurization Pump: 3/4 HP Re-Pressurization Pump: 3/4 HP

*Note: Based on an estimation of 5-10 gallons of spot-free rinse water per car.
Spot Free Systems
7

4
1
BT through JT Series
5
Reverse Osmosis System
3
2

6
150 150
100 200 100 200

50 250 50 250

2 00 2 00
0 0

80 80
60 100 60 100
40 120 40 120
20 140 20 140
6 6

11
80
60 100
40 120
20 1 40

0 160

10
9

8
FLEXEONs Spot Free Systems
1 Carbon Pre-Filter Reduces Chlorine, Bad Taste and Odor 7 Air Vent Filters Air
2 Water Softener Reduces Hardness 8 Drain Valve Drains Storage Tank
3 Reverse Osmosis Purifies Water 9 Feed Valve Shuts Off Supply to Repressurization Pump
4 Power Power for Reverse Osmosis System 10 Repressurization Pump Distributes Purified Water
5 Float Switch Turns Reverse Osmosis System On/Off 11 Output Valve Shuts Off Supply to Point Of Use (POU)
6 Storage Tank Stores Purified Water

Features and Benefits:


Complete Spot Free Solutions High Flow & Low Energy Membranes Individually Tested & Sanitized
Customizable System to Suit any Feed Water Quality Up to 98.5% Salt Rejection 1 Year Limited Warranty
High Recovery Rate (Product to Waste Ratio) Easy Maintenance & Servicing Made in the U.S.A.
Fully Equipped & Economical Compact & Space Saving

Customizable Stages:
Pre-Treatment: System can be customized with a chemical injection system, water softener,
and/or carbon pre-filter to help preserve the membrane and extend the life of the system.

Reverse Osmosis System: FLEXEON BT through JT Series can be configured as a complete


solution for many point-of-use and point-of-entry applications. See individual system specifi-
cation sheets for standard features and options.

Storage Tank: 300 Gallon white atmospheric storage tank (36 W x 79 H). Larger capac-
ity tanks are available.

Float Switch: Normally closed float switch automatically turns the reverse osmosis system on
and off and comes pre-wired with 110 or 220 volts.

Repressurization System: Delivery System provides proportional water delivery and features
a built-in pressure switch, 1 NPT connections, and is available with 110 or 220 volts. It
also allows for up to 22 gpm @ 30 psi with a maximum suction lift of 25 ft. at sea level.

P: 800-320-4074 W: www.axeonwater.com
F: 800-609-0829 E: sales@axeonwater.com
40980 County Center Drive, Suite 100, Temecula, CA 92591
MKTF-240 AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 04/15 2015 AXEON Water Technologies

Das könnte Ihnen auch gefallen