Sie sind auf Seite 1von 48

Call Processing

1
CONTENTS
Sprint MMBS System
System Information Broadcast
Cell Selection
Cell Reselection
Paging and Connection Setup
Intra-LTE Mobility

2013 Samsung Electronics 2


Sprint MMBS System

System Information Broadcast

2013 Samsung Electronics 3


System Information

The UE shall apply the system information acquisition procedure


Upon selecting a cell (e.g. upon power on) and reselecting a cell
After handover completion
After entering E-UTRA from another RAT
Upon return from out of coverage
Upon receiving a notification that system information has changed
Upon exceeding the maximum validity duration

SystemInformationBlocks (SIBs)
SIBs other than SIB1 are carried in SystemInformation (SI) messages
Mapping between SI messages and SIBs are flexibly configured by schedulinginfolist in SIB1

2013 Samsung Electronics SAMSUNG Electronics Co., Ltd. Confidential and Proprietary 4
System Information Control (1/3)
Master Information Block (MIB) Broadcast
The master information is transmitted at the fixed intervals defined in the specification.

It includes the eNBs downlink bandwidth, PHICH-related information, and system frame
number, etc.
Parameter

Parameter Name Parameter Meaning Default Value Relevant Command


DL_BANDWIDTH Downlink bandwidth used by an operating cell ci_SystemBandwidth_n50 DL BW value is set
{ci_SystemBandwidth_n6/ when the cell is growed.
ci_SystemBandwidth_n15/
ci_SystemBandwidth_n25/
ci_SystemBandwidth_n50/
ci_SystemBandwidth_n75/
ci_SystemBandwidth_n100}

2013 Samsung Electronics 5


System Information Control (2/3)
System Information Block (SIB) Broadcast
The system information consists of SIB1 to SIB13. Each of these is transmitted at its own set intervals, or
the same interval.

SIB1 : Information on scheduling, cell selection, and PLMN list for other SIBs (2-13)
SIB2 : Information on physical channel, and timer used by the UE
SIB3 : Information on cell reselection into an intra frequency in the EUTRAN system
SIB4 : Information on the list of neighbors which have an intra frequency
SIB5 : Information on cell reselection to an inter frequency in the EUTRAN system
SIB6 : Information on cell reselection into the UTRAN system
SIB7 : Information on cell reselection to the GSM EDGE Radio Access Network (GERAN) system
SIB8 : Information on cell reselection into the CDMA system
SIB9 : Home eNB-related information
SIB10 : Earthquake and Tsunami Warning System (ETWS) primary warning message
SIB11 : ETWS secondary warning message
SIB12 : Commercial Mobile Alert System (CMAS) warning message
SIB13 : Information on Multimedia Broadcast Multicast Service (MBMS)

2013 Samsung Electronics 6


System Information Control (3/3)
SIB Modification
A change is made to the system information when a system information parameter value changes, except for the warning message
parameter values (SIB10, 11, and 12).
When the UE receives the changed system information through paging, or the systemValueTag within SIB1, it applies the new system
information at the next modification period. The existing system information is maintained until the UE applies the new system
information
Parameter

Parameter Name Parameter Meaning Default Value Relevant Command


SIB2_PERIOD The transmission period for the system ci_rf16 CHG-SIB-INF
information block type 2 of the cell in the eNB {ci_rf8, ci_rf16, ci_rf32,
ci_rf64, ci_rf128, ci_rf256,
ci_rf512, ci_not_used}
... ... ...

SIB12_PERIOD The transmission period for the system ci_rf512


information block type 12 of the cell in the eNB {ci_rf8, ci_rf16, ci_rf32,
ci_rf64, ci_rf128, ci_rf256,
ci_rf512, ci_not_used}
SI_WINDOW The system Information window size of a cell in ci_si_WindowLength_ms20
the eNB. Each SI message is associated with one {ci_si_WindowLength_ms1/
SI-window, and does not overlaps with the SI- ci_si_WindowLength_ms2/
windows of other SI messages. That is, one SI is ci_si_WindowLength_ms5/c
sent to one SI window. The length of SI-window i_si_WindowLength_ms10/
is the same for all SI messages. The ci_si_WindowLength_ms15/
corresponding SI message in the SI-window is ci_si_WindowLength_ms20/
sent repeatedly ci_si_WindowLength_ms40}

2013 Samsung Electronics 7


Sprint MMBS System

Initial Cell Selection

2013 Samsung Electronics 8


PLMN Selection
USIM contains
A list of PLMN with associated access technology in priority order

PLMN selection
Automatic mode: UE utilizes a list of PLMNs in priority order. The highest priority PLMN is
selected
Manual mode: UE indicates to the user which PLMNs are available. Only when the user
makes a selection, UT tries to obtain normal service on the VPLMN

Support for PLMN selection


UE scans all RF channels in the E-UTRA bands to find available PLMNs
On each carrier, the UE search for the strongest cell and read its system information
Each found PLMN is reported to NAS as a high quality PLMN if the measured RSRP value is
greater than or equal to -110dBm

2013 Samsung Electronics 9


Cell Selection (1/2)
Searching for a Suitable Cell
The selected PLMN or registered PLMN or one of the Equivalent PLMN list

Not barred

Not part of forbidden TA

A cell that meets the cell selection criteria

Stored information cell selection or initial cell selection

2013 Samsung Electronics 10


Cell Selection (2/2)
Cell selection criteria
Srxlev > 0 AND Squal > 0

Where, Srxlev = Qrxlevmeas (Qrxlevmin + Qrxlevminoffset) Pcompensation

Squal = Qqualmeas (Qqualmin + Qqualminoffset)


Srxlev Cell selection RX level value (dB)
Squal Cell selection quality value (dB)
Qrxlevmeas Measured cell RX level value (RSRP)
Qqualmeas Measured cell quality value (RSRQ)
Qrxlevmin Minimum required RX level in the cell (dBm)
Qqualmin Minimum required quality level in the cell (dB)
Qrxlevminoffset Offset to the signalled Qrxlevmin taken into account in the Srxlev evaluatio
n as a result of a periodic search for a higher priority PLMN while campe
d normally in a VPLMN
Qqualminoffset Offset to the signalled Qqualmin taken into account in the Squal evaluation
as a result of a periodic search for a higher priority PLMN while camped
normally in a VPLMN
Pcompensation max(PEMAX PPowerClass, 0) (dB)
PEMAX Maximum TX power level an UE may use when transmitting on the uplin
k in the cell (dBm) defined as PEMAX in [TS 36.101]
PPowerClass Maximum RF output power of the UE (dBm) according to the UE power
class as defined in [TS 36.101]
Reference : 3GPP TS36.304 Section 5.2.3.2

2013 Samsung Electronics 11


SIB1
Access information and scheduling of other SIBs
Scheduling for SIB1
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
MCC0, MNC0 ~ PLMN-identityList DIGIT_MCC, DIGIT_MNC CHG-CELL-INFO
MCC5, MNC5
TRACKING_AREA_C The tracking area code (TAC) used by the cell in 0
ODE operation. It is used for transmission and stop {0x0-0xFFFF}
of warning message during paging to the UE.
This information is broadcast to the UE through
the SIB 1
PHY_CELL_ID The physical cell ID 0 CHG-CELL-IDLE
{0-503}
CELL_BARRED Whether a cell is barred or not. If the cell status ci_notBarred CHG-CELL-ACS
becomes shutdown, the cellBarred value of SIB1 {ci_barred/ci_notBarred}
becomes ci_barred. Also, when an operator set
this parameter to ci_barred, the cellBarred
value of SIB1 becomes ci_barred and it is
broadcasted
INTRA_FREQ_CELL_ Reselection of an intra frequency cell when a ci_intraFreqReselect_notAll
RESELECT cell selected by a UE is barred owed
{ci_intraFreqReselect_allow
ed/ci_intraFreqReselect_not
Allowed}
FREQUENCY_BAND Frequency band indicator information for 5 CHG-CELL-IDLE
_INDICATOR frequency of operating cell. This information is {1-64}
broadcasted to a UE through SIB 1
2013 Samsung Electronics 12
SIB2 (1/2)
Radio resource configuration information that is common for all Ues
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
ACCESS_BARRING_ Whether to use emergency call barring of a cell False CHG-BAR-PARA
EMERGENCY_CALL in a station {False/True}
BARRING_SIGNAL_ Whether to use ac-BarringforMO-Signaling of a False
USAGE cell in a base station {False/True}
BARRING_DATA_US Whether to use ac-BarringforMO-Data of a cell in False
AGE a base station {False/True}
UL_BANDWIDTH The uplink bandwidth used in the cell in ci_SystemBandwidth_n50 DL BW value is set
operation {ci_SystemBandwidth_n6/ when the cell is growed.
ci_SystemBandwidth_n15/
ci_SystemBandwidth_n25/
ci_SystemBandwidth_n50/
ci_SystemBandwidth_n75/
ci_SystemBandwidth_n100}

2013 Samsung Electronics 13


SIB2 (2/2)
Parameter Name Parameter Meaning Default Value Relevant Command
ACC_PROB_FAC_SI Access probability factor of a cell in a station. ci_p95 CHG-BAR-PARA
GNAL A UE can access a cell if a rand value (from 0 to {ci_p00/ci_p05/ci_p10/ci_
1), generated by the UE, is rand lt; p15/ci_p20/ci_p25/ci_p30
accessProbabilityFactor. If not, it cannot access a /ci_p40/ci_p50/
cell ci_p60/ci_p70/ci_p75/ci_p
80/ci_p85/ci_p90/ci_p95}
ACC_CLASS_BAR_TI Access barring time for a cell in a base station. ci_s512
ME_SIGNAL A UE does not perform RRC connection {ci_s4/ci_s8/ci_s16/ci_s32/
configuration until the T305 timer is elapsed if a ci_s64/ci_s128/ci_s256/ci_
random value (from 0 to 1), generated by the UE, s512}
is less than accessProbabilityFactor by assuming
the cell is barred. The T305 timer value is
calculated based on (0.7 + 0.6 * rand) * acBarring
time.
ACC_PROB_FAC_DA Access probability factor of a cell in a station. ci_p95
TA A UE can access a cell if a rand value (from 0 to {ci_p00/ci_p05/ci_p10/ci_
1), generated by the UE, is rand lt; p15/ci_p20/ci_p25/ci_p30
accessProbabilityFactor. If not, it cannot access a /ci_p40/ci_p50/
cell ci_p60/ci_p70/ci_p75/ci_p
80/ci_p85/ci_p90/ci_p95}
ACC_CLASS_BAR_TI Access barring time for a cell in a base station. ci_s512
ME_DATA A UE does not perform RRC connection {ci_s4/ci_s8/ci_s16/ci_s32/
configuration until the T305 timer is elapsed if a ci_s64/ci_s128/ci_s256/ci_
random value (from 0 to 1), generated by the UE, s512}
is less than accessProbabilityFactor by assuming
the cell is barred. The T305 timer value is
calculated based on (0.7 + 0.6 * rand) * acBarring
time.

2013 Samsung Electronics 14


Sprint MMBS System

Cell Reselection

2013 Samsung Electronics 15


Cell Reselection (1/2)
Intra-frequency and equal priority inter-frequency cell
reselection criteria
The cells are ranked according to the R criteria

The UE shall perform cell reselection to the best cell if


it is better ranked than the serving cell during a time interval TreselectionRAT
more than 1 second has elapsed since the UE camped on the current serving cell.

Rs = Qmeas,s + QHyst

Rn = Qmeas,n - Qoffset
Qmeas RSRP measurement quantity used in cell reselectio
ns.
Qoffset For intra-frequency: Equals to Qoffsets,n, if Qoffsets,n
is valid, otherwise this equals to zero.
For inter-frequency: Equals to Qoffsets,n plus Qoffsetf
requency, if Qoffsets,n is valid, otherwise this equals to
Qoffsetfrequency.

Reference : 3GPP TS36.304 Section 5.2.4.6

2013 Samsung Electronics 16


Cell Reselection (2/2)
E-UTRAN inter-frequency and inter-RAT frequency cell
reselection criteria

To Higher Priority Frequency


A cell of a higher priority RAT/ frequency fulfils Srxlev > ThreshX, HighP during a time interval
TreselectionRAT; and

More than 1 second has elapsed since the UE camped on the current serving cell.

To Lower Priority Frequency


The serving cell fulfils Srxlev < ThreshServing, LowP and a cell of a lower priority RAT/ frequency
fulfils Srxlev > ThreshX, LowP during a time interval TreselectionRAT; and

More than 1 second has elapsed since the UE camped on the current serving cell.
Reference : 3GPP TS36.304 Section 5.2.4.6

2013 Samsung Electronics 17


SIB3 (1/2)
Cell-reselection information
Parameter
Parameter Name Parameter Meaning Default Value Relevant
Command
Q_HYST In the cell reselection criteria, it is the offset value ci_q_Hyst_dB0 CHG-CELL-
added to the current serving cell. ci_q_Hyst_dB1 {ci_q_Hyst_dB0, ci_q_Hyst_dB1, RSEL
means the 1dB; and ci_q_Hyst_dB2 means the 2 dB ci_q_Hyst_dB2, ci_q_Hyst_dB3,
ci_q_Hyst_dB4, ci_q_Hyst_dB5,
ci_q_Hyst_dB6, ci_q_Hyst_dB8,
ci_q_Hyst_dB10, ci_q_Hyst_dB12,
ci_q_Hyst_dB14, ci_q_Hyst_dB16,
ci_q_Hyst_dB18, ci_q_Hyst_dB20,
ci_q_Hyst_dB22, ci_q_Hyst_dB24}
Q_HYST_SFMEDIU As for the Qhyst added to the current serving cell in 0
M the cell reselection criteria, it is the value added {0-3}
when the UE speed is medium. To apply the change
of this parameter, the
SPEED_STATE_RESEL_PARAMS_USAGE should be
changed to 1 in the CHG-MOBIL-STA beforehand
Q_HYST_SFHIGH As for the Qhyst added to the current serving cell in 0
the cell reselection criteria, it is the value added {0-3}
when the UE speed is high.
ci_Q_HystSF_dB_6 means -6dB and
ci_Q_HystSF_dB_4 means -4dB.
To apply the change of this parameter, the
SPEED_STATE_RESEL_PARAMS_USAGE should be
changed to 1 in the CHG-MOBIL-STA beforehand

2013 Samsung Electronics 18


SIB3 (2/2)
Cell-reselection information
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
THRESH_SERVING_L Cell reselection to a cell on a lower priority E- 31 CHG-EUTRA-FA
OW UTRAN inter-frequency or inter-RAT frequency if {0-31}
the serving cell fulfils Srxlev < ThreshServing,
LowP and a cell of a lower priority RAT/
frequency fulfils Srxlev > ThreshX, LowP during a
time interval TreselectionRAT
PRIORITY Priority of EUTRA FA 7
{0-7}
Q_RX_LEV_MIN Minimum Rx level required in the cell (in dBm) -64
{-70 to -22}
NEIGH_CELL_CONFI Indicates the neighbor cells configuration 1
G information {0-3}
T_RESELECTION Reselection timer value 1
{0-7}

2013 Samsung Electronics 19


SIB 4
Neighboring cell information relevant only for intra-frequency cell re-selection
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
PHY_CELL_ID Indicates the physical cell ID of the E-UTRAN 1 CHG/CRTE-NBR-
neighbor cell located near the eNB {0-503} EUTRAN
START_PCI The starting physical cell ID value of a black list 1 CHG/CRTE-BLACK-LIST
cell {0-503}
PCI_RANGE The range from the starting physical cell ID of a ci_rangePCI_n4
black list cell. For the single physical cell ID type, {ci_rangePCI_n4/ci_rangeP
it is not used CI_n8/...
ci_rangePCI_n252/ci_rang
ePCI_n504}

2013 Samsung Electronics 20


SIB 5
Information for inter-frequency cell re-selection
Parameter
Parameter Name Parameter Meaning Default Value Relevant
Command
EARFCN_DL Downlink E-UTRA Absolute Radio Frequency Channel 2525 CHG-EUTRA-FA
Number {0-65535}
Q_RX_LEV_MIN Minimum Rx level required in the cell (in dBm) -64
{-70 to -22}
T_RESELECTION Reselection timer value 1
{0-7}
THRESH_XHIGH The threshold used by the UE when reselecting the 31
frequency with priority higher than the currently {0-31}
camped frequency
THRESH_XLOW The threshold used to reselect the low-priority 31
frequency from the high-priority frequency {0-31}
MEASUREMENT_BAN Max. allowed measurement bandwidth for carrier ci_mbw50
DWIDTH frequency {ci_mbw6/ci_mbw15/ci_mbw25/ci
_mbw50/ci_mbw75/ci_mbw100}
PHY_CELL_ID Indicates the physical cell ID of the E-UTRAN neighbor 1 CHG/CRTE-NBR-
cell located near the eNB {0-503} EUTRAN
START_PCI The starting physical cell ID value of a black list cell 1 CHG/CRTE-BLACK-
{0-503} LIST
PCI_RANGE The range from the starting physical cell ID of a black ci_rangePCI_n4
list cell. For the single physical cell ID type, it is not {ci_rangePCI_n4/ci_rangePCI_n8/...
used ci_rangePCI_n252/ci_rangePCI_n50
4}
2013 Samsung Electronics 21
Sprint MMBS System

Paging and Connection Setup

2013 Samsung Electronics 22


Paging
The paging procedure transmits paging information to the UE in the RRC_IDLE status,
or notifies the UE in the RRC_IDLE or RRC_CONNECTED status that the system
information has changed. This section describes the paging procedure when the UE is
in idle mode.

Paging Message
PCCH : P-RNTI transmitted on PDCCH to address a paging message

Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
DEFAULT_PAGING_ When DRX is used, UE monitors a single paging ci_rf_256 CHG-PCCH-CONF
CYCLE occasion per DRX cycle. If UE-specific DRX is not {ci_rf32, ci_rf64, ci_rf128,
set by the upper layer, defaultPagingCycle of ci_rf256}
PCCH-Config in SIB2 is applied as the default DRX
cycle
NB The parameter required to calculate the paging ci_oneEighthT
frame and paging occasion using the TS 36.304 {ci_fourT, ci_twoT, ci_oneT,
method, which is a multiple of ci_halfT, ci_quarterT,
defaultPagingCycle ci_oneEighthT,
ci_oneSixteenthT,
ci_oneThirtySecondT}

2013 Samsung Electronics 23


Paging and Connection Setup

2013 Samsung Electronics 24


RRC Connection Establishment (1/2)
The RRC connection establishment procedure is to configure an RRC connection
between the eNB and the UE. The SRB1 is configured through this procedure.

In addition, the initial NAS dedicated information/message is sent from the UE to the
eNB through this procedure.

RACH

DL_SCH

(S-TMSI or 40bits random value)

(Add SRB, MAC Config, RLC Config)

(Selected PLMN, Registered MME)


25

2013 Samsung Electronics 25


RRC Connection Establishment (2/2)
PDCP Parameter
Parameter Name Parameter Meaning Default Value Relevant
Command
UM_SN_SIZE Size of the PDCP sequence number (SN) in the ci_len12bits CHG-PDCP-INF
RLC UM mode {ci_len7bits, ci_len12bits}
- ci_len7bits: 7 bit size (0-127) is used.
- ci_len12bits: 12 bit size (0-4095) is used
FWD_END_TIMER Time duration for which the PDCP layer of a 200
target eNB waits for End Marker after it receives {10-1000}
HO_COMPLETE message
DISCARD_TIMER Discard timer value for a packet buffer managed ci-discardTimer_infinity
per RB in the RLC AM mode. If no ACK is received {ci-discardTimer_ms50/
from RLC for a certain period of time, the packet ci-discardTimer_ms100/
is discarded in the packet buffer ci-discardTimer_ms150/
ci-discardTimer_ms300/
ci-discardTimer_ms500/
ci-discardTimer_ms750/
ci-discardTimer_ms1500/
ci-discardTimer_infinity}

2013 Samsung Electronics 26


Security Activation

2013 Samsung Electronics 27


Initial Security Activation
RRC connection establishment involves the establishment of SRB 1
AS security is not activated during the initial phase of RRC connection

After having initiated the initial security activation procedure, E-UTRAN initiates the
establishment of SRB2 and DRBs

Security comprises of
Integrity protection of RRC signaling (SRBs)
Ciphering of RRC signaling (SRBs) and user data (DRBs)

RRC handles the configuration of the security parameters which are part of AS
configuration
Integrity protection algorithm
Ciphering algorithm and parameters

2013 Samsung Electronics 28


Initial Security Activation
E-UTRAN applies procedures for security of UE in RRC_CONNECTED
Applied when only SRB1 is established

SecurityModeCommand message
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
INTEGRITY_EA_PRI Integrity Protection algorithm information that is EIA2 CHG-SECU-INF
OR supported by a base station {EIA0 : NULL, EIA1 : SNOW
3G, EIA2 : AES}

CIPHER_EA_PRIOR Ciphering algorithm information supported by a EEA2


base station {EEA0 : NULL, EEA1 :
SNOW 3G, EEA2 : AES}

2013 Samsung Electronics 29


Intra-LTE Mobility

30
Handover Procedures
Measurement Configuration
MeasurementControl

Handover Preparation

Handover Execution
Data Forwarding

Handover Completion

2013 Samsung Electronics 31


Handover Control of UE in RRC_CONNECTED
eNB configures the measurement and reporting of UE
Control of UE Measurements (frequency and neighbor cells)

Control of UE Reporting (Event based or periodic)

Subscriber specific control based on UE capability and information from MME


RAT supported, frequency and bandwidth supported, release, MIMO
HRL(Handover Restriction List), SPID, PLMN, etc.

eNB triggers handover procedures


Target cell decision based on measurement report

X2 Handover

S1 Handover

2013 Samsung Electronics 32


Sprint MMBS System

Measurement Configuration

2013 Samsung Electronics 33


Measurement Configuration (1/6)
The following parameters are included in the measurement configuration provided to the
UE.
Measurement objects
The object on which the UE must perform measurements.
The measurement object is a single E-UTRA carrier frequency for intra-frequency and inter-frequency.
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
EARFCN_DL Downlink E-UTRA Absolute Radio Frequency 2525 CHG-EUTRA-FA
Channel Number {0~65535}
MEASUREMENT_BAN Max. allowed measurement bandwidth for carrier ci_mbw50
DWIDTH frequency {ci_mbw6/ci_mbw15/ci_mb
w25/ci_mbw50/ci_mbw75/ci
_mbw100}
OFFSET_FREQ The frequency offset value which is applied to the ci_dB0
offsetFreq in the RRC Connection Reconfiguration {ci_dB-24/ci_dB-22/ci_dB-
message 20/ci_dB-18/ci_dB-16/ci_dB-
14/
ci_dB-12/ci_dB-10/ci_dB-
8/ci_dB-6/ci_dB-5/ci_dB-
4/ci_dB-3/
ci_dB-2/ci_dB-
1/ci_dB0/ci_dB1/ci_dB2/ci_d
B3/ci_dB4/ci_dB5/
ci_dB6/ci_dB8/ci_dB10/ci_dB
12/ci_dB14/ci_dB16/ci_dB18
/ ci_dB20/ci_dB22/ci_dB24}

2013 Samsung Electronics 34


Measurement Configuration (2/6)
Parameter Name Parameter Meaning Default Value Relevant Command
PHY_CELL_ID Indicates the physical cell ID of the E-UTRAN 1 CRTE/CHG-NBR-
neighbor cell located near the eNB {0-503} EUTRAN
IND_OFFSET Cell individual offset applied to an E-UTRAN neighbor ci_dB0
cell that is located around a base station. This is used {ci_dB-24/ci_dB-22/ci_dB-
for UE measurement in the RRC connected mode 20/ci_dB-18/ci_dB-16/ci_dB-
14/
ci_dB-12/ci_dB-10/ci_dB-
8/ci_dB-6/ci_dB-5/ci_dB-
4/ci_dB-3/
ci_dB-2/ci_dB-
1/ci_dB0/ci_dB1/ci_dB2/ci_d
B3/ci_dB4/ci_dB5/
ci_dB6/ci_dB8/ci_dB10/ci_dB
12/ci_dB14/ci_dB16/ci_dB18
/ ci_dB20/ci_dB22/ci_dB24}
PHY_CELL_ID Indicates the physical cell ID of the E-UTRAN 1 CHG/CRTE-BLACK-LIST
neighbor cell located near the eNB {0-503}

2013 Samsung Electronics 35


Measurement Configuration (3/6)
The following parameters are included in the measurement configuration provided to
the UE.
Reporting configuration
The reporting configuration list, each item of which consists of the reporting criterion and the
report format.
The reporting criterion is the reference information that the UE triggers to send a measurement
report. It is either a periodical event or a single event.
The report format includes the quantity information and the related information included by the
UE in a measurement report (e.g. number of cells to report).
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
A3_OFFSET RSRP threshold used for the EUTRA measurement 4 CHG-EUTRA-A3CNF
report triggering condition of Event A3 {-30 to 30}
A3_REPORT_ON_LE Whether to report when an UE satisfies Event A3 FALSE
AVE leaving condition. {FALSE/TRUE}
- False: Set the a3ReportOnLeave parameter to
False. Even when an UE satisfies leaving
condition, it is not reported (default).
- True: Set the a3ReportOnLeave parameter to
True. When an UE satisfies leaving condition, it is
reported.
HYSTERESIS Hysteresis value used in the entry or leave 0
condition for Event A3 {0-30}

2013 Samsung Electronics 36


Measurement Configuration (4/6)
Parameter Name Parameter Meaning Default Value Relevant Command
TIME_TO_TRIGGER The timeToTrigger value for the Event A3. The ci_TimeToTrigger_ms480 CHG-EUTRA-A3CNF
timeToTrigger is the time which should be {ci_TimeToTrigger_ms0/
satisfied for the UE to trigger the measurement ci_TimeToTrigger_ms40/
report .../
ci_TimeToTrigger_ms5120}
TRIGGER_QUANTIT The quantity used to calculate the triggering ci_rsrp
Y condition for Event A3. {ci_rsrp/ci_rsrq}
Either RSRP or RSRQ value is specified.
- ci_rsrp: trigger quantity of this event is set RSRP.
- ci_rsrq: trigger quantity of this event is set
RSRQ
REPORT_QUANTITY The information on quantity included in the ci_both
measurement report for the Event A3. It can be {ci_sameAsTriggerQuantity
specified to be the same as the trigger quantity, /ci_both}
or to contain both RSRP and RSRQ value
MAX_REPORT_CELL Max. number of cells included in the 8
measurement report for Event A3 {1-8}

2013 Samsung Electronics 37


Measurement Configuration (5/6)
Parameter Name Parameter Meaning Default Value Relevant Command
REPORT_INTERVAL The interval of measurement reports for the ci_ReportInterval_ms480 CHG-EUTRA-A3CNF
Event A3 {ci_ReportInterval_ms120/
ci_ReportInterval_ms240/
ci_ReportInterval_ms480/c
i_ReportInterval_ms640/
ci_ReportInterval_ms1024
/ci_ReportInterval_ms204
8/
ci_ReportInterval_ms5120
/ci_ReportInterval_ms102
40/
ci_ReportInterval_min1/ci_
ReportInterval_min6/
ci_ReportInterval_min12/c
i_ReportInterval_min30/
ci_ReportInterval_min60}
REPORT_AMOUNT The number of measurement reports for the ci_reportAmount_infinity
Event A3 {ci_reportAmount_r1/ci_re
portAmount_r2/ci_reportA
mount_r4/
ci_reportAmount_r8/ci_re
portAmount_r16/ci_report
Amount_r32/
ci_reportAmount_r64/ci_r
eportAmount_infinity}

2013 Samsung Electronics 38


Measurement Configuration (6/6)
Measurement identities
The measurement identity list, each item of which is associated with one measurement object and
one reporting configuration.

Quantity configuration
Quantity configuration includes the measurement quantities and related filtering information for
all event evaluation, each of which is set by the RAT type.

Measurement gaps
The period of time during which the UE performs measurements. UL/DL data transmission is
restricted during this period.
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
GAP_PATTERN_FOR_I Measurement gap pattern information used for inter- gapPattern0 CHG-MSGAP-INF
NTER_FA frequency measurement. The default is gapPattern0. {gapPattern0/gapPattern1}
- gapPattern0: 0-39.
- gapPattern1: 0-79

2013 Samsung Electronics 39


Measurement Report Triggering
Intra-LTE measurement events
Event A1 - Serving becomes better than threshold. (Gap deactivated)
Ms Hys Thresh

Event A2 - Serving becomes worse than threshold. (Gap activated)


Ms Hys Thresh

Event A3 - Neighbour becomes offset better than serving.(HO triggering)


Mn Ofn Ocn Hys Ms Ofs Ocs Off

Event A4 - Neighbour becomes better than threshold.


Mn Ofn Ocn Hys Thresh

Event A5 - Serving becomes worse than threshold1 and neighbour


becomes better than threshold2.
Ms Hys Thresh1 Mn Ofn Ocn Hys Thresh2
2013 Samsung Electronics 40
Neighbor eNB
This Table is for neighbor eNB Configuration
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
NO_X2 Whether to make X2 connection to the neighboring eNB. False CRTE/CHG-NBR-ENB
- False: X2 connection with the neighboring eNB is made. {False/True}
- True: X2 connection to the neighboring eNB is not made.
NO_HO Whether to perform handover to the neighboring eNB. False
- False: Handover to the neighboring eNB is performed. {False/True}
- True: Handover to the neighboring eNB is not
performed.
ENB_ID The eNB ID represents the neighboring eNB. If the 0
enbType value is macro eNB, 20 bit of the value is eNB ID. {0x0 - 0xff}
If the enbType value is home eNB, 28 bit of the value is
eNB ID.
ENB_MCC The PLMN information (MCC) that represents the "DIGIT_MCC"
neighboring eNB. It is a three-digit number with each
digit being from 0 to 9.
ENB_MNC The PLMN information (MNC) that represents the "DIGIT_MNC"
neighboring eNB. It is a three-digit or two-digit number
with each digit being from 0 to 9.
NBR_ENB_IPV4 Enter the IP address of the neighboring eNB in the IP "0.0.0.0"
version 4 format.

2013 Samsung Electronics 41


Neighbor Cell (1/2)
This Table is for neighbor Cell Configuration
Parameter
Parameter Name Parameter Meaning Default Value Relevant Command
ENB_ID The eNB ID represents the neighboring eNB. If the 0 CRTE/CHG-NBR-ENB
enbType value is macro eNB, 20 bit of the value is eNB ID. {0x0 - 0xff}
If the enbType value is home eNB, 28 bit of the value is
eNB ID.
ENB_MCC The PLMN information (MCC) that represents the "DIGIT_MCC"
neighboring eNB. It is a three-digit number with each
digit being from 0 to 9.
ENB_MNC The PLMN information (MNC) that represents the "DIGIT_MNC"
neighboring eNB. It is a three-digit or two-digit number
with each digit being from 0 to 9.
PHY_CELL_ID Indicates the physical cell ID of the E-UTRAN neighbor cell 0
located near the eNB {0-503}
TAC The tracking area code of the E-UTRAN neighbor cell 0
located near the eNB {0x0-0xFFFF}
MCC0 The PLMN list information (MCC) of a E-UTRAN neighbor "DIGIT_MCC"
cell located around a base station, Enter 3-digit number
whose each digit range is 0-9
MNC0 The PLMN list information (MNC) of a E-UTRAN neighbor "DIGIT_MNC"
cell located around a base station, Enter 3-digit or 2-digit
number whose each digit range is 0-9

2013 Samsung Electronics 42


Neighbor Cell (2/2)
Parameter Name Parameter Meaning Default Value Relevant
Command
EARFCN_UL Uplink EARFCN (E-UTRAN Absolute Radio Frequency 20500 CRTE/CHG-NBR-ENB
Channel Number) of a E-UTRAN neighbor cell located {0-65535}
around a base station
EARFCN_DL Downlink EARFCN (E-UTRAN Absolute Radio Frequency 2525
Channel Number) of E-UTRAN neighbor cell located {0-65535}
around a base station
BANDWIDTH_UL Uplink bandwidth information of a E-UTRAN neighbor cell ci_SystemBandwidth_n25
around a base station {ci_SystemBandwidth_n6/
ci_SystemBandwidth_n15/
ci_SystemBandwidth_n25/
ci_SystemBandwidth_n50/
ci_SystemBandwidth_n75/
ci_SystemBandwidth_n100}
BANDWIDTH_DL Downlink bandwidth information of a E-UTRAN neighbor ci_SystemBandwidth_n25
cell around a base station {ci_SystemBandwidth_n6/
ci_SystemBandwidth_n15/
ci_SystemBandwidth_n25/
ci_SystemBandwidth_n50/
ci_SystemBandwidth_n75/
ci_SystemBandwidth_n100}
TAC The tracking area code of the E-UTRAN neighbor cell 0
located near the eNB {0x0-0xFFFF}

2013 Samsung Electronics 43


Terminology
Mn is the measurement result of the neighbouring cell, not taking into account any offsets.
Ofn is the frequency specific offset of the frequency of the neighbour cell (i.e. offsetFreq as defined
within measObjectEUTRA corresponding to the frequency of the neighbour cell).
Ocn is the cell specific offset of the neighbour cell (i.e. cellIndividualOffset as defined within
measObjectEUTRA corresponding to the frequency of the neighbour cell), and set to zero if not
configured for the neighbour cell.
Ms is the measurement result of the serving cell, not taking into account any offsets.
Ofs is the frequency specific offset of the serving frequency (i.e. offsetFreq as defined within
measObjectEUTRA corresponding to the serving frequency).
Ocs is the cell specific offset of the serving cell (i.e. cellIndividualOffset as defined within
measObjectEUTRA corresponding to the serving frequency), and is set to zero if not configured for the
serving cell.
Hys is the hysteresis parameter for this event (i.e. hysteresis as defined within reportConfigEUTRA for
this event).
Off is the offset parameter for this event (i.e. a3-Offset as defined within reportConfigEUTRA for this
event).
Mn, Ms are expressed in dBm in case of RSRP, or in dB in case of RSRQ.
Ofn, Ocn, Ofs, Ocs, Hys, Off are expressed in dB.
2013 Samsung Electronics 44
Copyright and Confidentiality
Copyright 2013, SAMSUNG Electronics Co., Ltd. SAMSUNG Electronics reserves the right to make changes to the specifications of
the products detailed in this document at any time without notice and obligation to notify any person of such changes. Information
in this document is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated,
transcribed or duplicated by any form without the prior written consent of SAMSUNG Electronics.
Problem Report

46
The problem

2013 Samsung Electronics 47


Copyright and Confidentiality
Copyright 2013, SAMSUNG Electronics Co., Ltd. SAMSUNG Electronics reserves the right to make changes to the specifications of
the products detailed in this document at any time without notice and obligation to notify any person of such changes. Information
in this document is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated,
transcribed or duplicated by any form without the prior written consent of SAMSUNG Electronics.

Das könnte Ihnen auch gefallen