PowerLink Power Calculation for PLPA and PLE Power Amplifier

Please select the type of amplifier: PLPA


Enter the nominal output power. For adjacent mode consider max output power adjustment(manual chapt.4 -TX level setti
Expected noise level for BW 4 kHz [dBm]:
Please enter the expected noise level !
75 Ohm

PowerLink Services
Transmit
Service selection Output Level [dB] Level dBm
Speech Ch1
Speech Ch2
Speech Ch3
Analog data F3 Ch1
Analog data F3 Ch2
Data FSK 1
Data FSK 2
Data FSK 3
Data FSK 4

F6 AMP with Speech Ch1


F6 AMP with Speech Ch2
F6 AMP with Speech Ch3
F6 SP/MP
DP QAM Signal Bandwidth
F6 AMP with DP
F2 Pilot 1
F2 Pilot 2
F2 Pilot 3
DP Pilot
SysPilot
Remote Monitoring RM
SUM ACN 0

EKP

No plausibility check of the service adjustments! No bandwidth calculation!


Power (W)
17 Noise Level?
nt(manual chapt.4 -TX level setting) 17
Max. possible Line attenuation [dB]:

min
Receive Level Noiselevel

The DP Function is activated, when the Bandwidth


Signal is selected!

#N/A

Required min DP bitrate for iMUX data channels 1-4


Bitrate UART
Ch1 9600 7N1
Ch2
Ch3
Ch4

iMUX 9600

Required min DP bitrate for vMUX


vMUX vMUX Bit rate calculation

Required DP bitrate for external data interfaces


X.21 9600..320000
G703.1 64000
EMUX 9600..320000
dth calculation!
oise Level?

tenuation [dB]:

ed, when the Bandwidth for the DP QAM


gnal is selected!

#N/A

MUX data channels 1-4

8534
0
0
0
8534 Max Rate: 8534
10391.3 Frame 66.675
RM 218.18
MUX

al data interfaces
Noise levels (adverse weather):

Values acc. IEEE 643 for a bandwidth of 4 kHz: Values acc. IEC 60663 for a band

HV - line Frequency Noise level HV - line in kV


in kV kHz dBm <220
>220
110 75 -17
110 250 -23
110 500 -25

230 75 -13
230 250 -18
230 500 -20

400 75 -8
400 250 -13
400 500 -15

Back to PowerCalc
acc. IEC 60663 for a bandwidth of 4 kHz:

Noise level in dBm


-25
-10
Calculation of the DP Bit rate when using the vMUX

Voice channels
kbps Bit rate Input Group
Voice Ch 1
Voice Ch 2
Voice Ch 3
Voice Ch 4
Voice Ch 5
Voice Ch 6
Voice Ch 7
Voice Ch 8

Asynchronous data channels


bps Bit rate Data Mode UART
RS232-1
RS232-2
RS232-3
RS232-4
RS232-5
RS232-6
RS232-7
RS232-8

Synchronous data channels


bps Bit rate
X21-1
X21-2

rFSK channels
Baudrate Data Mode UART/Samplerate
rFSK 1
rFSK 2

Remote Monitoring
Enabled
RM No

Datapump Bit rate for vMUX: bps

DP rate for vMUX and ETH: bps


Ethernet channel
bps Enabled Calc Eth rate Back to Power calculation
ETH data No
ack to Power calculation