Sie sind auf Seite 1von 5

Test Results of TMT Steel Bar

Forwarded to; Name of Client : Senior Section Engineer ( C ) (Works) Western Railway-Patan
Senior Section Engineer
( C ) (Works) Western Railway- Name of Work : DY/CE/C/PYN-BUDI/8
Patan
Ref No.and Date: T.N. PTM-BUDI/8 Dtaed: '05/12/10
Sample Sent by : Client
Report No.: MAP/10-11/12/05/AS-3 Name of Agency : M/s Ajay Engi Infra Pvt Ltd. Mehsana
Date: 13/12/10 Agreement No.: --
Page : 1 of 1 Structure(s) Name: --
Date of Sample Received: 05/12/10 Type of Sample : TMT Steel Bars
No. of Sample(s): 1 Diameter of Sample: 20.00 mm
Condition of Sample on Receipt: Satisfactory Specification of Sample:
Name of Test: As mentioned below Garde of Sample : Fe 415
Test Method Standard: As mentioned below Environmental Condition during test : As per the test procedure
Date of Test Starting : 05/12/10 Date of Test Completion : 12/12/10
Sr. Test Method Results obtained Specifications Remarks
Type of Test
No. Standard Sample-1 Sample-2 Sample-3 As per IS - 1786

1 Diameter (mm) IS - 1786 20.04 -- -- Min. 20.00 mm

2 Cross Sectional Area (mm2) IS - 1786 315.26 -- -- Min. 314.3 mm2

3 Gauge Length ( mm ) IS - 1608 100.32 -- -- Min. 100 mm

4 Weight per meter run (kg ) IS - 1786 2.470 -- -- Min. 2.47 Kg/m 3 %

Results are
Yield Stress / Proof Stress 0.2 %
5 IS - 1608 428 -- -- Min. 415 N/mm2 Conformed as
(N/mm2)
per IS-1786

6 Ultimate Stress (N/mm2) IS - 1608 520 -- -- Min . 485 N/mm2

7 Elongation ( % ) IS - 1608 24.10 -- -- Min. 14.5 %

8 Bend IS - 1599 No Crack -- --


Should not show any
transverse Crack
9 Rebend IS - 1786 No Crack -- --

* The test result relates to the sample(s) supplied by the client/agency. for MAP Technical Consultancy
NOTES

* The Results / Reports are issued with specific understanding that MAP will not
in way be involved in acting following interpretation of the test results.
* The Results / Reports are not supposed to be used for publicity. Authorised Signatory
Test Results of TMT Steel Bar
Forwarded to; Name of Client : Senior Section Engineer ( C ) (Works) Western Railway-Patan
Senior Section Engineer
( C ) (Works) Western Railway- Name of Work : DY/CE/C/PYN-BUDI/8
Patan
Ref No.and Date: T.N. PTM-BUDI/8 Dtaed: '05/12/10
Sample Sent by : Client
Report No.: MAP/10-11/12/05/AS-3 Name of Agency : M/s Ajay Engi Infra Pvt Ltd. Mehsana
Date: 13/12/10 Agreement No.: --
Page : 1 of 1 Structure(s) Name: --
Date of Sample Received: 05/12/10 Type of Sample : TMT Steel Bars
No. of Sample(s): 2 Diameter of Sample: 25.00 mm
Condition of Sample on Receipt: Satisfactory Specification of Sample:
Name of Test: As mentioned below Garde of Sample : Fe 415
Test Method Standard: As mentioned below Environmental Condition during test : As per the test procedure
Date of Test Starting : 05/12/10 Date of Test Completion : 12/12/10
Sr. Test Method Results obtained Specifications Remarks
Type of Test
No. Standard Sample-1 Sample-2 Sample-3 As per IS - 1786

1 Diameter (mm) IS - 1786 25.02 25.03 -- Min. 25.00 mm

2 Cross Sectional Area (mm2) IS - 1786 491.41 491.80 -- Min. 491.1 mm2

3 Gauge Length ( mm ) IS - 1608 125.25 125.30 -- Min. 125 mm

4 Weight per meter run (kg ) IS - 1786 3.850 3.846 -- Min. 3.85 Kg/m 3 %

Results are
Yield Stress / Proof Stress 0.2 %
5 IS - 1608 420 416 -- Min. 415 N/mm2 Conformed as
(N/mm2)
per IS-1786

6 Ultimate Stress (N/mm2) IS - 1608 516 510 -- Min . 485 N/mm2

7 Elongation ( % ) IS - 1608 20.50 20.68 -- Min. 14.5 %

8 Bend IS - 1599 No Crack No Crack --


Should not show any
transverse Crack
9 Rebend IS - 1786 No Crack No Crack --

* The test result relates to the sample(s) supplied by the client/agency. for MAP Technical Consultancy
NOTES

* The Results / Reports are issued with specific understanding that MAP will not
in way be involved in acting following interpretation of the test results.
* The Results / Reports are not supposed to be used for publicity. Authorised Signatory
Test Results of TMT Steel Bar
Forwarded to; Name of Client : Senior Section Engineer ( C ) (Works) Western Railway-Patan
Senior Section Engineer
( C ) (Works) Western Railway- Name of Work : DY/CE/C/PYN-BUDI/8
Patan
Ref No.and Date: T.N. PTM-BUDI/8 Dtaed: '05/12/10
Sample Sent by : Client
Report No.: MAP/10-11/12/05/AS-3 Name of Agency : M/s Ajay Engi Infra Pvt Ltd. Mehsana
Date: 13/12/10 Agreement No.: --
Page : 1 of 1 Structure(s) Name: --
Date of Sample Received: 05/12/10 Type of Sample : TMT Steel Bars
No. of Sample(s): 1 Diameter of Sample: 32.00 mm
Condition of Sample on Receipt: Satisfactory Specification of Sample:
Name of Test: As mentioned below Garde of Sample : Fe 415
Test Method Standard: As mentioned below Environmental Condition during test : As per the test procedure
Date of Test Starting : 05/12/10 Date of Test Completion : 12/12/10
Sr. Test Method Results obtained Specifications Remarks
Type of Test
No. Standard Sample-1 Sample-2 Sample-3 As per IS - 1786

1 Diameter (mm) IS - 1786 32.03 -- -- Min. 32.00 mm

2 Cross Sectional Area (mm2) IS - 1786 805.35 -- -- Min. 804.6 mm2

3 Gauge Length ( mm ) IS - 1608 160.34 -- -- Min. 160 mm

4 Weight per meter run (kg ) IS - 1786 6.311 -- -- Min. 6.31 Kg/m 3 %

Results are
Yield Stress / Proof Stress 0.2 %
5 IS - 1608 416 -- -- Min. 415 N/mm2 Conformed as
(N/mm2)
per IS-1786

6 Ultimate Stress (N/mm2) IS - 1608 512 -- -- Min . 485 N/mm2

7 Elongation ( % ) IS - 1608 17.60 -- -- Min. 14.5 %

8 Bend IS - 1599 No Crack -- --


Should not show any
transverse Crack
9 Rebend IS - 1786 No Crack -- --

* The test result relates to the sample(s) supplied by the client/agency. for MAP Technical Consultancy
NOTES

* The Results / Reports are issued with specific understanding that MAP will not
in way be involved in acting following interpretation of the test results.
* The Results / Reports are not supposed to be used for publicity. Authorised Signatory