MQM FTTH Project

OTDR Test Analysis and Technical Work


Flow Guidelines
Version 1
Cibubur - Bekasi and Depok

Date : 14 Dec 2013


Level 19 Floor
MQM Project Meeting Room www.huawei.com

Prepared by : Pak Rahim 85589


TD implementation
MQM FTTH project
Certified Professional Fiber To the Home
CHFP Fiber Council USA

Huawei Confidential
Training Objective:

To guide site engineer during OTDR fiber test at site


To give knowledge OTDR concept and know how to read OTDR
trace and witness OTDR test by sub con & MQM
To brief standard fiber setting, total loss accepted parameter and
rectify solution from OTDR result.
OTDR project work process and test result acceptance inspection
Brief of OTDR test result sample found and problem finding during
OTDR test done by subcon
To control OTDR test procedures to minimize error and time.

Huawei Confidential Page 2


MQM FTTH Project Acceptance Test
Test Specification Requirement: Revision
Link Optical Performance Test
OTDR Test
Optical Power Meter

Huawei Confidential Page 3


MQM FTTH Project Acceptance Test
Testing requirement
-
1. OTDR Test

2 ways

1. Both 1550nm and 1310nm wavelength.


2. (ODF to FDT) and (FDT-ODF) 2 ways

Huawei Confidential Page 4


MQM FTTH Project Acceptance Test
Testing procedures :
2. OTDR Test cluster

B C
1 way

1. To test OTDR both 1550nm and 1310nm wavelength.


2. FDT- FAT (B-C)

Huawei Confidential Page 5


MQM FTTH Project Acceptance Test protocol

OTDR setting parameter :


Date : must the real OTDR date with time.
1310nm : IOR : 1.46770
1550nm : IOR 1.46820.
Range OTDR must be 25% longer than actual distance
Pulse : 50ns -100ns;
Average time : 20s for feeder: 15 sec for cluster.
Splice loss Analysis thresholds : 0.01db; ORL : -65db; Reflectance
threshold: -65db
End of fiber threshold : 5-10db.

Huawei Confidential Page 6


MQM FTTH Project Acceptance Test
OTDR Testing Output Parameter Test Result
OTDR test data output
1.Date of test and time : real time
2.Testing direction ; exam : Bekasi OLT FDT1 Perum Jati
3.Fiber ID tested : core no
4.Wavelength tested : 1310 and 1550nm
5.Origin location and Destination location, cluster name.
6.Tester Name.
Measurement Parameters to cover
1.Fiber length (L) in km
2.Total Loss or cumulative loss
3.Fiber attenuation loss in dB/km
4.Splice loss < 0.08 dB. bothway
5.Optical Return Loss (ORL) at connector > 65dB.

Huawei Confidential Page 7


MQM FTTH Project Acceptance Test Protocol
OTDR Feeder Test Analysis documentation
Splice loss Calculation Table ( Feeder Link
OTDR Printout Presentation Sheet Splice Loss Measurement
(Result from OTDR)

Project Name : FTTH 300K HP Date Test : 27 August 2013


ACCEPTANCE TEST PROCEDURE
Region : Cibubur Link : OLT to FDT
TEST OTDR RESULT
From (A) : OLT Citra Indah Jonggol To (B) : FDT Bukit Gladiola
Origin Site Test Date :
Wavelength 1330/1550 Cluster : CABLE JOINT SPLICE
IOR : 1310nm : 1.46770 JOINT NO : 01 JOINT NO : 02 JOINT NO : 03
Fiber Qty/length Link : 1550nm : 1.46820
Distance (Km) Distance (Km) Distance (Km)
Splice Threshold : 0.01db
Test Result Reject/ Accepted Action : TO OTDR TO OTDR TO OTDR TO OTDR TO OTDR TO OTDR
SPAN SPAN SPAN
Cable
Capacity :
(A - B) (B - A) (A - B) (B - A) (A - B) (B - A)
5.242 2.919 2.323 5.242 3.930 1.312
TUBE CORE
SPLICE LOSS SPLICE LOSS SPLICE LOSS

NO COLOR NO COLOR Direction OTDR (dB) AVG LOSS Direction OTDR (dB) AVG LOSS Direction OTDR (dB) AVG LOSS
A-B -0.06 A- B 0.11 A- B
1 Blue -0.01 0.00
B-A 0.05 B- A -0.11 B- A
A-B A- B A- B
2 Orange
B-A B- A B- A
A-B A- B A- B
3 Green
B-A B- A B- A
A-B A- B A- B
4 Brown
B-A B- A B- A
A-B A- B A- B
5 Slate
B-A B- A B- A
B A-B A- B A- B
6 White
l B-A B- A B- A
1
u A-B A- B A- B
7 Red
e B-A B- A B- A
A-B A- B A- B
8 Black
B-A B- A B- A
A-B A- B A- B
9 Yellow
B-A B- A B- A
A-B A- B A- B
10 Purple
B-A B- A B- A
A-B A- B A- B
11 Pink
B-A B- A B- A
A-B A- B A- B
12 Aqua
B-A B- A B- A
A-B A- B A- B
13 Blue
B-A B- A B- A
A-B A- B A- B
14 Orange
B-A B- A B- A
A-B A- B A- B
15 Green
B-A B- A B- A
A-B A- B A- B
16 Brown
B-A B- A B- A
A-B A- B A- B
17 Slate
O B-A B- A B- A
Verify by SubCon Tester Huawei Site Engineer Huawei Manager R A-B A- B A- B
18 White
A B-A B- A B- A
2
Name N A-B A- B A- B
19 Red
G B-A B- A B- A
Date E A-B A- B A- B
20 Black
B-A B- A B- A
A-B A- B A- B
21 Yellow
B-A B- A B- A
Signature A-B A- B A- B
22 Purple
B-A B- A B- A
A-B A- B A- B
23 Pink
B-A B- A B- A
A-B A- B A- B
24 Aqua
B-A B- A B- A

Huawei Confidential Page 8


MQM FTTH Project Acceptance Test Protocol
OTDR Cluster Test Analysis
OTDR Printout Presentation Sheet Cable Measurement Table ( Distribution Link)
Splice Loss Measurement
(Result from OTDR)

Project Name : MQM FTTH PROJECT Date Test : 27 August 2013


ACCEPTANCE TEST PROCEDURE
TEST OTDR RESULT Region : CIBUBUR OLT : OLT East Cibubur
Cluster : Oma Indah Regency 2 & 2A Line No : LINE A

Origin Site Test Date :


Wavelength 1330/1550 Cluster : NO COLOR FAT NO. NO COLOR
OTDR Distance
(Km)
(B-C) total Span Loss (dB)
1310 nm 1550 nm
NO COLOR FAT NO. NO COLOR
OTDR Distance
(Km)
(B-C) total Loss (dB)
1310 nm 1550 nm

Fiber Qty/length Link : 1 Blue 1 Blue


2 Orange 2 Orange
3 Green 3 Green

Test Result Reject/ Accepted Action : 4


5
Brown
Slate S
4
5
Brown
Slate
B
6 White L 6 White
L
1 FAT 01 5 A FAT 05
U 7 Red 7 Red
T
E 8 Black 8 Black
E
9 Yellow 9 Yellow
10 Purple 10 Purple
11 Pink 11 Pink
12 Aqua 12 Aqua
1 Blue 1 Blue
2 Orange 2 Orange
3 Green 3 Green
4 Brown 4 Brown
O
5 Slate W 5 Slate
R
6 White H 6 White
A
2 FAT 02 6 I FAT 06
N 7 Red 7 Red
T
G 8 Black 8 Black
E
E
9 Yellow 9 Yellow
10 Purple 10 Purple
11 Pink 11 Pink
12 Aqua 12 Aqua
1 Blue 1 Blue
2 Orange 2 Orange
3 Green 3 Green
4 Brown 4 Brown
G
5 Slate 5 Slate
R R
6 White 6 White
3 E FAT 03 7 E FAT 07
7 Red 7 Red
E D
8 Black 8 Black
N
9 Yellow 9 Yellow
10 Purple 10 Purple
11 Pink 11 Pink
12 Aqua 12 Aqua
1 Blue 1 Blue
2 Orange 2 Orange
3 Green 3 Green
4 Brown 4 Brown
B B
5 Slate 5 Slate
R L
6 White 6 White
4 O FAT 04 8 A FAT 08
7 Red 7 Red
W C
8 Black 8 Black
N K
9 Yellow 9 Yellow
10 Purple 10 Purple
11 Pink 11 Pink
12 Aqua 12 Aqua

Verify by SubCon Tester Huawei Site Engineer Huawei Manager


Signatures:

Name Responsible Subcontractor Responsible Huawei Responsible Customer

Date Name: Name: Name:


ID: ID: ID:
Signature: Signature: Signature:

Signature Date: Date: Date:

Huawei Confidential Page 9


MQM FTTH Project Acceptance Test
OTDR Test Report submission
Any fiber found rejected/Fail need to be rectified first before submission .
Site engineer must checked and verify test result first before submitted.
Only the pass OTDR test result must be printed and submit.
All test result must be complied in the hard file with proper arrangement by
OTDR 1310nm and 1550nm must be separated.
Summary of OTDR must be on the top of OTDR test for final verification.
Only PASS result shall be burn in CD format

OTDR test report submission

1. Summary Splice Loss for feeder


2. OTDR test result A B and B A for 1310nm ( feeder)
3. OTDR test result A B and B A for 1550nm (feeder)
4. Summary Cable length & loss for cluster
5. OTDR B-C for 1310 and 1550nm ( cluster)

Huawei Confidential Page 10


OTDR and OPM Test Work Flow Process for
MQM FTTH project

Huawei Confidential Page 11


ATP Test Work Flow for MQM FTTH Project

Huawei Confidential Page 12


Detail OTDR Site Work Flow Process

Huawei Confidential Page 13


Technical -OTDR
OTDR Test Preparation

Test Gear requirement:


1. OTDR with 1550nm and 1310nm wavelength.
2. Patch cord jumper LC-APC(20m)
3. Proper test support required testing.(connector
examination scope, connector cleaning tool,
Isopropyl alcohol & dispenser, lint-free tissue.
Cletop etc)
4. OTDR power back up.

Documents required for OTDR


1. Draft as built cable drawing for testing.
2. OTDR Acceptance Form
3. FDT key
4. Berita Acara/ approved test permit.
5. Flash disk (result taken after test immediately)

Huawei Confidential Page 14


Test Preparation for OTDR test (Indonesia version)
Berikut adalah plan persediaan untuk OTDR untuk pengetahuan
Mohon bantuan Huawei RPM:
Mohon kabari site engineer Huawei PIC mesti turut serta dilapangan nanti untuk serta ujian
OTDR
Tes ini direkomen di mulakan di OLT dahulu dan kemudian di FDT.
Mohon diuruskan kuncinya di OLT dan FDT dari pihak MQM NOC
Masa tes yang baik pada waktu pagi. Kerana bisa diperbaiki pada hari yang sama jika ada
kerosakkannya.

Berikut adalah petunjuk dan cara cara persediaan untuk membuat kerja kerja OTDR.
Mohon bantuan Partner
OTDR material persediaan:
OTDR machine yg baik dan patch cord yg baru dan baik termasuk spare patch cord.
Cable skema drawing yang telah updated. sesuai dengan yang dipasang di lapangan seperti
closure yang di pasang dilapangan.
Sila bawa splice machine untuk repair sekali jika perlu dibaiki kerosakan denga segera
Sediakan alcohol 99% dan alat jointing kit jika perlu untuk baiki kerosakan
Mohon sediakan tenda payung pasar untuk tes di FDT. Kerana bacaan OTDR tidak kelihatan
sebabkan cahaya matahari.
Pastikan OTDR batteri cukup bekalan kuasa, bawa generator untuk standby OTDR battery
charge.
Ujian OTDR di berhentikan jika hujan turun deras

Huawei Confidential Page 15


Test Preparation for OTDR test (Indonesia version)
Standard work flow when to perform OTDR test

Cara cara OTDR yang standard:


Data mesin di ambil, model, serial number dan gambar. Catat nama OTDR tester, PT
subcon. BA di lapangan.
Membuat setting parameter di OTDR.setting. jika OTDR ada status PASS atau FAIL
harus di on untuk mengetahui status testnya.
OTDR tes harus mengikut turutan kabel yang pertama diikuti core kedua hingga
selesai. Tidak benar di selang seli core semasa tes. Masa tes mesti mengikut
settingnya.
Semua keputusan akan di ambil softcopynya setelah selesai untuk analisa dan
rumusan untuk di perbaiki.
Sekiranya terdapat kerosakkan dijumpai, fiber mesti diperbaiki terus supaya cepat
selesai.
Selesai di perbaiki , mesti di OTDR semula.
Kes 1 Jika ada kerosakan satu atau lebih core di splice closure dibuat, maka ujian
OTDR ulang harus dilakukan ke semua core tersebut.contoh : 96 core
Kes 2 jika kerosakkan di splice tray di OLT atau FDT; kesemua fiber di splice tray itu
harus di ulang tes.. 1-12 core.

Huawei Confidential Page 16


Test Preparation for OTDR test (Indonesia version)
Standard work flow when to perform OTDR test

OTDR Naming harus ditulis terang dengan informasi test dijalankan


1. Feeder:
OLT- FDT one way untuk 2 wavelength 1310 dan 1550nm
FDT- OLT one way untuk 2 wavelength 1310 dan 1550nm
Contoh nama test
GRAHA PRIMA RW.27, OLT FDT1 1310 - 01
GRAHA PRIMA RW.27 , OLT FDT1 1550 - 01
GRAHA PRIMA RW.27 , OLT FDT1 1330 - 02
GRAHA PRIMA RW.27 ,FDT1 OLT 1550 - 02
GRAHA PRIMA RW.27 , FDT1OLT 1310 - 03
GRAHA PRIMA RW.27 , FDT1 - OLT 1550 - 03

1. Cluster:
FDT FAT one way untuk 2 wavelength 1310 dan 1550nm
FAT FDT one way untuk 2 wavelength 1310 dan 1550nm.
Contoh:
GRAHA PRIMA RW.27. FDT - FAT A01 1310 -01
GRAHA PRIMA RW.27. FDT - FAT A01 1550 -01

GRAHA PRIMA RW.27. FAT - FDT A01 1310 -01


GRAHA PRIMA RW.27. FAT - FDT A02 1550 -01

Huawei Confidential Page 17


OTDR Test Performed 2

What to do before test:


Check OTDR model, serial Number Check
and tester name, Functional OTDR OTDR used

Check at ODF if test at ODF that all


fiber is termination, correct label
before test. If FDT, check cable
already terminated
Check the OTDR setting by asking Model
tester to set the standard Serial No

parameter before actual testing.


Check the patch cord or launch
cable are good. Clean the connector
with alcohol before connected to
ODTR.
All as built drawing and previous
self check OTDR result

Huawei Confidential Page 18


2
Test OTDR Procedure at ODF or FDT

Direction Test

When OTDR test perform, test must follow the sequence number start from Core 1, then core 2
until core 12 or finish. Do not jump the core. All test data such as cable name, OLT name, FDT
cluster name, wavelength, date & time must be saved in OTDR .

Huawei Confidential Page 19


OTDR Test Observation
When the OTDR test conducted
Observe the core tested and
save core in the OTDR is
correct and in follow sequence
.Do not skip the core.
Continuing test until finish.
Look to OTDR and observe on
the following events:
1.Distance is correct length
2.Total loss of the fiber.
3.Splice location

Note:
All termination fiber at ODF and OTDR fiber measurement on site training for
FDT must be tested except working new engineer
core. Do not remove working core.
Or remove the patch cord.

Huawei Confidential Page 20


Event need to focus

Example of High Loss found during OTDR test

High loss bending at 1.75km from FDT to OLT


Loss is 2.878 dB

Need to repair by subcon.

Total Length cable


Total Loss
4.68km
4.6db
Huawei Confidential Page 21
Event need to focus

Point No 2 is highest point =3db


Many loss found

Huawei Confidential Page 22


Test Result Analysis

When the OTDR test is


progressing and finished.
1) Focus on the length, high
loss and cut fiber events.
The location of closure
splice also need to identify
for splice loss calculation
2) Record only Fail status in
the OTDR form
3) Copy the test result
softcopy from OTDR to
external pen drive memory
by USB as referance
4) Use OTDR softcopy then
open the test result for
checking.

Huawei Confidential Page 23


OTDR Test Result Analysis.
This form is to collect fail status for analysis.
Loss Measurement
(Result from OTDR)
Total
Project Name MQM FTTH Project Date length: 4.68
How to fill: Region Bekasi North
Location (A) FDT 02 Bumi Lestri Location (B) OLT North Bekasi

During OTDR test : CABLE Feeder OTDR Loss Analysis


OTDR Limit Loss Max High High Loss Max High High Loss
TUBE CORE
2.47: 2.00
1310nm Loss Location 1550nm Loss Location
Only Fail Status is recorded and NO COLOR NO COLOR Direction Total Loss dB
km
Total Loss dB
km
Pass/Fail

A-B No reading No Reading


fill in this form as refrance for
Fail
1 Blue
B-A
A-B 14.48 2.97 1.75 4.616 2.87 1.75 Fail
repair .
2 Orange
B-A
A-B Ok Ok Pass
3 Green
Three data need to record: B-A
A-B No reading No Reading Fail
4 Brown
B-A
Core No; Max High loss and 5 Slate
A-B Ok Ok Pass
B-A
location of core problem B 6 White
A-B Ok Ok Pass
l B-A
1
u A-B Ok Ok Pass
7 Red
e
B-A
A-B Ok Ok Pass
The accepted OTDR loss limit 8 Black
B-A
A-B Ok Ok Pass
9 Yellow
can be to OTDR link loss budget B-A
A-B Ok Ok pass
10 Purple
plan loss document B-A
A-B Ok Ok Pass
11 Pink
B-A
A-B 2.93 0.35 1.75 Ok Fail
12 Aqua
B-A

This documents are for our


internal use between Huawei
and subcon purpose.

Huawei Confidential Page 24


OTDR test result How to fill explanation: Sample 1
Highest loss value and location Loss Measurement Only Fail result taken from OTDR
(Result from OTDR) test result
Total
Project Name MQM FTTH Project Date 10 Dec 2013 length: 4.68
Region Bekasi North
Location (A) FDT 02 Bumi Lestri Location (B) OLT North Bekasi
CABLE Feeder OTDR Loss Analysis
OTDR Limit Max High
Loss Max High High Loss
TUBE CORE 1310nm High Loss 1550nm
Loss Location
2.47: 2.00 Loss Location Pass/Fail
COLO
km km
NO R NO COLOR Direction Total Loss dB Total Loss dB
A-B No reading No Reading Fail
1 Blue
B-A
A-B 14.48 2.97 1.75 4.616 2.87 1.75 Fail
2 Orange
The B-A
OTDR A-B Ok Ok Pass
3 Green
B-A
limit loss
A-B No reading No result No Reading Fail
plan 4 Brown
B-A
A-B Ok Ok Pass
5 Slate
B-A
B A-B Ok Ok Pass
6 White
l B-A
1
u A-B Ok Ok Pass
7 Red
e B-A
A-B Ok Ok Pass
8 Black
B-A
A-B Ok Ok Pass
9 Yellow
B-A
A-B Ok Ok pass
10 Purple
B-A
A-B Ok Ok Pass
11 Pink
B-A
A-B 2.93 0.35 1.75 Ok Fail
12 Aqua
B-A

Huawei Confidential Page 25


OTDR Feeder Loss Plan The OTDR limit loss plan

This Excel document is created to find the maximum OTDR maximum limit loss for Cibubur, Depok and Bekasi Region.
This is to give easy reference for site engineer to know what is the maximum loss limit when conducted OTDR at site.

Below is how to estimate the OTDR test limit for 1310 and 1550nm when do OTDR at site

OTDR Feeder Loss Reference : Sample of North Bekasi


Feeder Planning
Link Loss OLT-FDT Loss OTDR Loss Limit
Feed Feeder Feeder
Feeder Clous Install loss (dB) loss (dB) loss (dB) loss (dB)
Feed er OLT
no Cluster Name OLT ure Closur
er Plann OTDR (dB)
(dB) e (dB)
Line ing Read 1310 1550 1310 1550
No.
Plan length Lengt
h Length 0.4 0.1 0.1 0.4 0.3 0.4 0.3
PERUM BUMI LESTARI North Line
39
RW 14 (1) Bekasi E 4.738 4.52 1 1 1 2.40 1.92 2.31 1.86
PERUM BUMI LESTARI North Line
40
RW 14 (2) Bekasi E 4.555 4.68 1 2 2 2.42 1.97 2.47 2.00

A B Planning loss value.

This value is taken from This value is taken from actual C


OTDR test result. when OTDR site closure installed OTDR loss limit as a
shown length on screen The engineer need to fill the reference value for site
The engineer need to fill the actual number of closure engineer when OTDR test for
length of fiber from the OTDR install at site by sub con feeder. If high than this ,it fail.
to this colum

Huawei Confidential Page 26


Rectification work.
After OTDR completed, only the fail result need to repair:
Site engineer need to keep one copy of this fail status for repair reference.
Coordinate with sub con repair team and plan rectification based on OTDR
fail result on length, core and fault location
Once the repair done, the new OTDR need to conduct again to ensure the
core fault below the loss limit.
If the core fault is on closure splice joint, all core need to test again: For
Pass core status: using real time OTDR to prove continues fiber.
The repair core get PASS must be saved in different folder and copy to pen
drive for site engineer reference.

Huawei Confidential Page 27


Print OTDR result and fill form

If all the core is PASS status, the OTDR test result can be
printed out and submit the softcopy to huawei.
The sub con need to fill the ATP OTDR form based on the
PASS OTDR test result.
The site engineer need to check and verify that all core tested
ate meet the requirement.

Huawei Confidential Page 28


OTDR documentation

Only the pass OTDR status need to print and submit to


Huawei
The ATP OTDR form need to fill and submit to Huawei
Document Manager :
1. Mba Aishah Cibubur region
2. Mba Violetta Depok and Bekasi region

All OTDR test result must be verify by site engineer and RPM.

Huawei Confidential Page 29


Reading OTDR guidelines

OTDR Trace Finding


Highlighted the problems finding for improvement

Huawei Confidential Page 30


Standard OTDR Trace Loss

Huawei Confidential Page 31


OTDR Standard Test Method
All sub con is recommended to use dummy fiber at least 2km for OTDR testing
as below:

Dummy 1 Dummy 2
2km 2km

Test Fiber

Huawei Confidential Page 32


SAMPLE OF OTDR TEST RESULT
COMMENTS AND RECOMENDATION

Huawei Confidential Page 33


Study Sample OTDR
Fibre start
Fibre end
A B REJECT Trace

Trace too small

Fiber reflectance bending/ high reflectance

Fiber end No information required

Fiber length
Attenuation Coefficient

Huawei Confidential Page 34


Study Sample OTDR

A Good Feeder OTDR B

Fibre start
Fibre end

Good reading with wide OTDR trace

All the trace must show all event splice, cable attenuation and total loss

Huawei Confidential Page 35


Study Sample OTDR

Connector loss
Small bend loss Loss Splice branch
Gain Splice Joint 1
Fibre end
Fibre start

Fibre test

All the trace must show all event splice, cable attenuation and total loss

Huawei Confidential Page 36


Study Sample OTDR
REJECT Trace
The trace is too narrow.

Distance range too long compare link length

Not experience tester

The section is not informative and not required to show?????.

Huawei Confidential Page 37


Study Sample OTDR
Rejected Trace due to losses
and length range

1 High loss
2 Trace too small

This part is not required to show.

Huawei Confidential Page 38


Study Sample OTDR
Reject

All trace are same but difference core

Fake OTDR test result finding

All same

Huawei Confidential Page 39


Study Sample OTDR
Reject

Wrong Date setting

Wrong Date setting : 5 January 2007

Huawei Confidential Page 40


Study Sample OTDR Reject

Very high bending at OLT


Cable bend : 3db loss =50% power loss

Huawei Confidential Page 41


High loss
Many high loss found clearly: should repair.

High loss 4 db ;very high

Huawei Confidential Page 42


Splice Joint Loss Calculation

Huawei Confidential Page 43


Concept Closure Joint location for 2 ways OTDR trace

OLT -FDT

0km 2.9km 5.7km


Joint 1 Joint 2 6.8km

OLT
FDT

6.8km 3.9km 1.1km 0km


FDT -OLT

Huawei Confidential Page 44


Sample how to add 2 ways OTDR for joint splice loss calculation from OTDR trace

ODF FDT

1.1km -0.11 db
2.9km
0.09db

5.7km
6.8km -0.05db 0.16 db
3.9km

6.8km

Huawei Confidential Page 45


Splice Joint Loss Calculation
How to calculate splice loss value in the form (A-B and B-A from OTDR trace)

Refer to the OTDR trace for both OLT-FDT and From FDT to OLT from page 45

TO OTDR TO OTDR TO OTDR TO OTDR


SPAN SPAN

(A - B) (B - A) (A - B) (B - A)
5.242 2.919 2.323 5.242 3.930 1.312
CORE
SPLICE LOSS Joint 1 SPLICE LOSS Joint 2

NO COLOR Direction OTDR (dB) AVG LOSS Direction OTDR (dB) AVG LOSS

A-B 0.06 A-B 0.16


1 Blue 0.01 0.05
B-A -0.05 B-A -0.11

For Joint 1
for Joint 2

Huawei Confidential Page 46


Document OTDR submission
The documents submitted should be proper oder and well organised.

1. Softcopy PASS status.


2. OTDR Hard copy Pass Status.

Softcopy :

Submit with following format :


Folder : Cluster name XXXX- Feeder : Cibubur: Oma Indah 2 -Feeder
Feeder OLTXXX -FDT XXXX : OLT CTRL FDT 01.
Folder 1310 : example core 1 12.
Folder 1550 : example core 1 12.
The test result wavelength must be separated.

Folder : Cluster name YYYY- Cluster : Cibubur : Oma Indah 2 - Cluster


Folder : FDT XX-FAT XX : FDT 01 FAT 01 15.
Folder 1310 : FAT 01
Folder 1550 : FAT 01

Huawei Confidential Page 47


Document OTDR submission
The documents submitted should be proper oder and well organised.

1. OTDR Hard copy Pass Status.

HardCopy:
Compile in Hard cover file.
Arrange with following format :
Folder : Cluster name XXXX- Feeder : Cibubur: Oma Indah 2 -Feeder
Feeder OLTXXX -FDT XXXX : OLT CTRL FDT 01.
Folder 1310 : example core 1 12.
Folder 1550 : example core 1 12.

The test result wavelength must be separated.

Folder : Cluster name YYYY- Cluster : Cibubur : Oma Indah 2 - Cluster


Folder : FDT XX-FAT XX : FDT 01 FAT 01 15.
Folder 1310 : FAT 01
Folder 1550 : FAT 01

Huawei Confidential Page 48


Document Arrangement layout

3
2
Cover 1
1

2 OTDR ATP Form


OTDR Test Result
3 OTDR hard copy Region
Cluster
1310
1550

Huawei Confidential Page 49


Thank you