Sie sind auf Seite 1von 4

Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Flow chart: Fixed column bases


This flowchart describes the design procedure for a fixed column base connection.

Start

Column dimensions
Design forces
Nc,Ed, Mc,Ed, Vc,Ed
Base plate Determine base plate dimensions
dimensions No based on design compression
known? force Fc,Ed
Concrete class
Base plate steel grade
Anchor bolt class
Yes

Base plate
dimensions

Anchor bolts Determine anchor bolt dimensions


dimensions No and base plate thickness for
known? design tension force Ft,Ed
This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

Anchor bolt
Yes diameter
Plate thickness

Verify joint for combined


SN043 5
MEd and NEd for all load
combinations

Mc,Ed Mj,Rd ? No Modify base design

SN021
Yes

SN037 Calculate shear


Fv,Rd
resistance

Modify base design for


No Vc,Ed Fv,Rd ?
shear resistance
Created on Monday, January 22, 2007

Yes

End

1
Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Determination of base plate dimensions, based on compression force

Start

Design forces at
column base
Concrete class

SN043 Calculate maximum


4.3 compression force acting Fc,Ed
on the foundation

SN043
Determine base plate Dimensions
4.3
dimensions tp, hp, bp
This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

Return
Created on Monday, January 22, 2007

2
Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Determination of anchor bolt dimensions

Start
Design forces at
column base

Base plate details


Concrete class
Bolt class

SN043 Calculate maximum


4.3 tensile force on the Ft,Ed
foundation
This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

SN043 Determine anchor bolt Bolt diameter


4.5.1, 4.5.2 dimensions and required Base plate
base plate thickness thickness tp

Return
Created on Monday, January 22, 2007

3
Flow chart: Fixed column bases

Flow chart: Fixed column bases


SF045a-EN-EU

Quality Record
RESOURCE Title Flow chart: Fixed column bases

Reference(s)
ORIGINAL DOCUMENT
Name Company Date
Created by Ivor Ryan CTICM 07/02/2006
Technical content checked by Alain Bureau CTICM 07/02/2006
Editorial content checked by
Technical content endorsed by the
following STEEL Partners:
1. UK G W Owens SCI 23/5/06
2. France A Bureau CTICM 23/5/06
3. Sweden B Uppfeldt SBI 23/5/06
4. Germany C Mller RWTH 23/5/06
5. Spain J Chica Labein 23/5/06
Resource approved by Technical
G W Owens SCI 21/8/06
This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement

Coordinator
Created on Monday, January 22, 2007

Das könnte Ihnen auch gefallen