Sie sind auf Seite 1von 3

Design of 180MW Steam Power Plant

PUMP SELECTION

Condensate Pump

The flow rate of the condensate from the condenser will be increased by 5%
as an allowance. The capacity of the condensate pump will be

Ccp = 878,895 x 1.05

Ccp = 922,840 lb per hr

Ccp = 1846 GPM

For the developed head,

Deaerator Pressure with 10% = 54.12


allowance =49.2X1.10 psia
Assuming Piping Pressure Drop =10 psi

=64.12
Total psia

=0.7382
Less Condenser Pressure psia
=63.4
Total psia

=146.4
Converting into Head (ft of water) ft.

From TORISHIMA PUMPMFG. CO., LTD pump catalog the following pump has
been chosen;

Brand: Torishima Pumps

Model: CPCN (End- Suction Volute Pump)

Pump Selection 24
Design of 180MW Steam Power Plant

Boiler Feed Pump

The flow
rate of the

water from the


deaerator will be increased by 5% as an allowance. The capacity of the boiler
feed pump will be

Cbfp = 107,140 x 1.05

Cbfp = 1,215,900 lb per hr

Cbfp = 2432 GPM

For the developed head,

= 1996.17
Boiler Pressure with 10% allowance =1814.7X1.10 psia
Assuming Piping Pressure Drop =10 psi

=2006.17
Total psia

Less Deaerator Pressure =49.2 psia


=1956.97
Total psia

=4520.6
Converting into Head (ft of water) ft.

From TORISHIMA PUMPMFG. CO., LTD pump catalog the following pump has
been chosen;

Pump Selection 25
Design of 180MW Steam Power Plant

Pump Selection 26