design a cyclone to recover solids from a process gas stream. The anticipated particle size distribution
The density of thebparticles 2500 kg/m3, and the gas is essentially nitrogen at 150 0C.
The stream volumetric flow rate is 10000 m3/h, and the operation is at atmospheric preassure. An 85
solution
As 30 % of the particle are below 10 m, the high-efficiency design will be required to give the specifi
flow rate
density
flow rate
area of inlet duct, at 15 m/s
from figure 10.44a
duct area
so, Dc
this is clearly too large compared with the standard design diameter of 0,203 m.
try four cyclones in parallel,
Dc=
flow rate per cyclone
Density of gas at 150 0C
The performance calculations, using this scaling factor and figure 10.45a, are set out in Table 10.12
The collection efficiencies shown in column 4 of the table were read from Figure 10.45 at the scaled pa
The overall collection efficiency satisfies the specified solida recovery
The proposed design with dimensions in the proportions given in Figure 10.44a is shown in Figure 10.4
50 0 10
50 40 15
40 30 10
30 20 10
20 10 25
10 5 20
5 2 6
2 0 4
u1 15 m/s
area of exit pipe= 90856.4814814815 mm2
u2 7.6 m/s
50 40 30 20 10
90 75 65 55 30
2.78 m3/s
0.19 m2
(0,5*Dc)*(0,2*Dc)
1.361 jauh dari standar Dc1
0.68 680.41
2500 m3/h
0.81 kg/m2
0.023 cp(mNs/m)
1.85
mm2
mm2
53.3865578318 mm H2O
5 2
10 4