GENERAL NOTES

1. CONCRETE SHALL HAVE A


MINIMUM CHARACTERISTIC
STRENGTH OF 30N/mm
1b. CHARACTERISTIC STRENGTH
OF REINFORCMENT BE 500N/mm2
FOR A HIGH TENSILE.

3. CEMEMTN SHALL BE ORDINA-


RY PORTLAND TO BS. 12

A B C D E F 4. MAXIMUM AGGREGATE SIZE


SHALL BE 20mm AND IT SHALL
CONFORM TO BS 882
FFL 9.000
03-Roof Plan
5. COVER TO STRUCTURAL
MEMBERS SHALL BE AS
FOLLOWS:
i) SUB-STRUCTURE = 50mm
ii)COLUMN = 30mm
3000

iii) SLABS = 30mm


iv) BEAMS = 30mm
FFL 6.000
02-Second Floor(pent house) 6.LAP LENGTH SHALL NOT BE
LESS
THAN 50 X DIAMATER

7. ALL STRUCTURAL DRAWINGS


3000

SHOULD BE READ IN
CONJUCTION
FFL 3.000
WITH RELEVANT ARCHITECTURE
01-First floor plan DRAWINGS, MECHANICAL AND
ELECTRICAL DRAWINGS

8. STIRRUP HOOKS SHOULD BE


FIXED TO ALTERNATE ON
3000

OPPOSITE SIDES OF ALL


REINFORCMENT
FFL 0.000
0-Ground floor plan
9. ALL SURFACES OF
STRUCTURAL
1450

MEMBERS SHOULD BE
FFL -1.450 FURNISHED
00-foundation plan

10. WATERPROOFING
MEMBRANE
SHOULD BE INSTALLED FOR ALL
SLABS AT GRADE

11. CONTINUATION BARS FOR


COLUMNS SHOULD BE LAPED AT
THE POINT OF CONTRAFLEXURE
AND SHOULD ALSO BE CRACKED.

Section 1
1 1 : 50

No. Description Date PROPOSED


KNUST EXERCISE FILE 01
PATCADS Structural Solutions Ltd PROJECT CLIENT
G57/4 Giffard Road (Opp Trade Fair)
APPARTMENT
14-Mar-17 2:51:25 PM
POB CT6286, Accra-Ghana
T. +233 248 488 943 Date Project number Scale (@ A3)
E. mail: info.patcads@gmail.com 30/05/2014 Project Number 1 : 50
SHEET Drawn by DRWAING NUMBER REV
CODE STATUS SUITABILITY DESCRIPTION PURPOSE OF ISSUE
Author
SECTION 1-1 Checked by S.9
Checker

Das könnte Ihnen auch gefallen