Sie sind auf Seite 1von 8

SENTRON SLVB Fusible Bus Plug

busway
SYSTEMS
Siemens is proud to introduce the NEW SENTRON SLVB BUS PLUG
The Right Plug for Demanding Applications

Dual stab busway interlock prevents installation or removal of the bus plug
with the switch in the ON position.

Dual door interlocks prevent cover from being opened when the switch
in the ON position and prevent switch from being turned ON when the is
cover is open.

Secure bolt-on mounting.

Spring loaded pad lockable latch to prevent unauthorized access.

Heavy duty, double breaking rotary switch fast, positive, and reliable for
severe applications.

Direct drive mechanism the operating handle mounts directly to the switch
mechanism for fewer moving parts.

Replacement parts many components can be replaced from a stock of


easy-to-install replacement parts.

Rugged, easy-to-grip handle.

Highly visible ON/OFF indication.

Handle lockout design provides for up to three padlocks.

Compact footprint for either horizontal SLVBH or riser


SLVBR applications.

Hook stick operable.

We have streamlined the design to


minimize footprint and maximize
capability. Rigidity and safety features
have been enhanced. Enhanced
features at a reduced price. For
demanding applications, you can
be assured the NEW SENTRON SLVB
BUS PLUG will perform.
Catalog Numbering System

S L V B R 3 2 1 0 G

Plug Type
SL = Sentron II
Heavy Duty Fusible Switch
VB
Orientation
R = Riser
H = Horizontal
Configuration (Poles/Wires)
3 = 33W
4 = 34W
5 = 34W 200% Neutral
Voltage
2 = 240V
6 = 600V
Max Ampere Rating
1 = 30A
2 = 60A
3 = 100A
4 = 200A
5 = 400A*
6 = 600A* * Available March 2006
IP Rating
0 = IP40
4 = IP55
Ground Designation
G = Internal Ground
IG = Isolated Ground
SENTRON SLVB Wall Clearance and Bus Plug Dimensions

Horizontal Application

Riser Application
Wall Clearance and Bus Plug Dimensions Horiz. (in/mm)
Dim. No Cradle
30 60 100 200 400/600*
A 13.13(333) 13.13(333) 13.13(333) 14.68(372)
B 13.86(352) 14.86(377) 15.86(402) 22.86(580)
C 7.96(202) 7.96(202) 7.96(202) 10.58(268)
D 15.89(403) 16.68(423) 17.68(449) 24.66(626)
E 2.67(67) 2.67(67) 2.67(67) 2.67(67)
F 6.19(157) 7.19(182) 8.19(208) 15.19(385)
G 20.39(517) 20.39(517) 20.39(517) 24.76(628)
H 13.09(332) 13.09(332) 13.09(405) 16.55(420)
J 2.65(67) 2.65(67) 2.65(67) 3.40(86)
K 2.18 (55) 2.18(55) 2.18(55) 3.18(80)
L 2.65(67) 2.65(67) 2.65(67) 2.65(67)
M 15.07(382) 15.07(382) 15.07(382) 16.82(427)

Wall Clearance and Bus Plug Dimensions Riser (in/mm)


Dim. No Cradle
30 60 100 200 400/600*
A 10.13(257) 10.13(257) 11.13(282) 14.68(372)
B 13.86(352) 14.86(377) 15.86(402) 22.86(580)
C 7.96(202) 7.96(202) 7.96(202) 10.58(268)
D 15.89(403) 16.68(423) 17.68(449) 24.66(626)
E 2.38(60) 2.38(60) 3.38(85) 4.75(120)
F 4.06(103) 4.06(103) 4.06(103) 6.44(163)
G 17.39(441) 17.39(441) 18.39(467) 24.76(628)
H 13.09(332) 13.09(332) 13.09(332) 16.55(420)
J 2.65(67) 2.65(67) 2.65(67) 3.40(86)
K 2.18 (55) 2.18(55) 2.18(55) 3.18(80)
L 3.55(90) 3.55(90) 3.55(90) 3.55(90)
M 12.07(306) 12.07(306) 13.07(331) 16.82(427)

* Available March 2006


Standard Fusible Bus Plug Ratings
Plug-In-units Fused Sw. Fuse Fuse Kits Max. Short Circuit
Series Max. Rating Class R Fuse Kits T Fuse Kits Current Rating
SLVB_21 30A, 240V H,K,R HR21 200KA, 240V,3-ph
SLVB_61 30A, 600V H,K,R,J HR612 200KA, 600V,3-ph
SLVB_22 60A, 240V H,K,R HR612 200KA, 240V,3-ph
SLVB_62 60A, 600V H,K,R,J HR62 200KA, 600V,3-ph
SLVB_23 100A, 240V H,K,R,J,T HR63 200KA, 240V,3-ph
SLVB_63 100A, 600V H,K,R,J,T HR63 HT63 200KA, 600V,3-ph
SLVB_24 200A, 240V H,K,R,J,T HR64 HT24 200KA, 240V,3-ph
SLVB_64 200A, 600V H,K,R,J,T HR64 HT64 200KA, 600V,3-ph
SLVB_25 400A, 240V H,K,R,J,T HR656 200KA, 240V,3-ph
SLVB_65 400A, 600V H,K,R,J,T HR656 200KA, 600V,3-ph
SLVB_26 600A, 240V H,K,R,J,T HR656 200KA, 240V,3-ph
SLVB_66 600A, 600V H,K,R,J,T HR656 200KA, 600V,3-ph

Standard Fusible Bus Plug Horsepower Ratings


240V, 240V, 480V, 600V
Plug-In-units Fused Sw. 1Phase 3Phase 3Phase 3Phase The SENTRON SLVB BUS PLUG meets all UL and
Series Max. Ratings Std. Max. Std. Max. Std. Max. Std. Max. CSA standards to assure reliable performance
SLVB_21 30A, 240V 1.5 3.0 3.0 7.5 in all environments. The installer and end user
will appreciate NEW features like Highly Visible
SLVB_61 30A, 600V 5.0 15.0 7.5 20.0
Position Indicator, Dual Stab Busway Interlocks,
SLVB_22 60A, 240V 3.0 10.0 7.5 15.0 Dual Cover Interlocks, and Bolt-on Mounting.
SLVB_62 60A, 600V 15.0 30.0 15.0 50.0
SLVB_23 100A, 240V 7.5 15.0 15.0 30.0 SENTRON SLVB Fusible Bus Plugs are available
in 30, 60, 100, 200, 400, and 600 amp ratings
SLVB_63 100A, 600V 25.0 60.0 30.0 75.0
(compatible with H, R, T, K and J fuses).
SLVB_24 200A, 240V 15.0 25.0 60.0
SLVB_64 200A, 600V 50.0 125.0 60.0 150.0 Available March 2006
SLVB_25 400A, 240V 15.0 50.0 125.0
SLVB_65 400A, 600V 100.0 250.0 125.0 350.0
SLVB_26 600A, 240V 15.0 75.0 200.0
SLVB_66 600A, 600V 150.0 400.0 200.0 500.0

Fusible Switch Plug, Load Lugs, and Knockouts


Ampere Ground Lug Neutral Lug Phase Lug Knockout Sizes
Rating Cu/A Cu/AI Cu/AI In.(mm)
30 #14-1/0 #14-2 #14-2 7/8(22), 1 1/8(29), 1 3/8(35), 1 3/4(44), 2(51), 2 1/2(64)
60 #14-1/0 #14-1/0 #14-2 7/8(22), 1 1/8(29), 1 3/8(35), 1 3/4(44), 2(51), 2 1/2(64)
100 #14-1/0 #14-1/0 #14-1/0 7/8(22), 1 1/8(29), 1 3/8(35), 1 3/4(44), 2(51), 2 1/2(64)
200 #14-1/0 #6-300MCM #6-300MCM 1 3/8(35), 1 3/4(44), 2(51), 2 1/2(64), 3(76)
400 #6-350MCM (2)1/0-250MCM or (2)1/0-250MCM or 7/8(22), 1 1/8(29)
(1)1/0-750MCM (1)1/0-750MCM
600 #6-350MCM (4)1/0-250MCM or (4)1/0-250MCM or 7/8(22), 1 1/8(29)
(2)1/0-750MCM (2)1/0-750MCM
Horizontal Applications
SLVBH

Horizontal Fusible Bus Plug Dimensions and Weights (Enclosure Only)


Ampere Dimensions Inches (mm) Weight
Rating A B C D max. E F J K lbs (kg)
30 13.13(333) 13.86(352) 7.96(202) 2.60(66) 6.18(156) 2.66(67) 2.65(67) 2.06(52) 23.5(10.66)
60 13.13(333) 14.86(377) 7.96(202) 2.60(66) 7.18(182) 2.66(67) 2.65(67) 2.06(52) 25.5(11.56)
100 13.13(333) 15.86(402) 7.96(202) 2.60(66) 8.18(207) 2.66(67) 2.65(67) 2.06(52) 28.0(12.70)
200 14.88(377) 22.86(850) 10.58(268) 2.60(66) 15.88(403) 2.66(67) 3.40(86) 3.06(77) 49.0(22.22)
*400
*600
* Available March 2006
Riser Applications
SLVBR

Riser Fusible Bus Plug Dimension and Weights (Enclosure Only)


Ampere Dimensions Inches (mm) Weight
Rating A B C D max. E F J K lbs (kg)
30 10.13(257) 13.86(352) 7.96(202) 5.25(133) 2.74(69) 2.36(59) 2.65(67) 2.06(52) 26.5(12.02)
60 10.13(257) 14.86(377) 7.96(202) 5.25(133) 2.74(69) 2.36(59) 2.65(67) 2.06(52) 28.5(12.92)
100 11.13(282) 15.86(402) 7.96(202) 5.25(133) 7.74(196) 3.36(85) 2.65(67) 2.06(52) 30.0(13.60)
200 14.88(377) 22.86(580) 10.58(268) 5.90(149) 5.11(129) 4.74(120) 3.40(86) 3.06(77) 48.5(21.99)
*400
*600
* Available March 2006
Siemens Energy & Automation, Inc.
3333 Old Milton Parkway
Alpharetta, GA 30005

1-800-964-4114
info.sea@siemens.com

www.sea.siemens.com

2005 Siemens Energy & Automation, Inc. All Rights Reserved.


Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective
companies. Specifications are subject to change without notice.

BUBR-PLUGAP-1205 New 5M1205B&A Printed in USA