Invisible Fastening with Adhesive

The panels can be fastened invisibly on a metal substructure using negative effect on the adhesion. All the recommendations from the
adhesive. The quality of the adhesive connection depends on the adhesive manufacturer must be followed to ensure the best adhe-
external conditions. Moist, cold or dusty surroundings can have a sion.

Adhesive fastening

Download

4
2

VRC structure
1) Masonry
2) Thermal Separator
3) Wall bracket
4) Bracket screw
5) Vertical profile
6) Adhesive & laying tape
7) fibreC panel

52
Planning Details

Substructure Preparations / processing


Exclusively metal substructure. The bonding must be vertical.
The subconstruction and the reverse of the plate must be
Fastening ground.
The Sika Tack Panel system manufactured by Sika with the licence The subconstruction must be cleaned with a special cleaner
Z-10.8-408 or equivalent must be used as an adhesive bonding (205) appertaining to the system. Drawing-out time 10 minutes
mount. As a general rule, the manufacturers processing guidelines The reverse of the plate must be dusted and must not be
must be observed. Only certified firms may perform adhesive work cleaned with the cleaner (205) in any circumstances.
on the Sika Tack Panel system. The subconstruction and the reverse of the panel must be
primed. Drawing-out time 30 minutes
The weather-related principles must be complied with during the Caution the panels may not be stored vertically during the
works: drawing-out time.
Processing temperature: 5C 35C After the preliminary work, bonding can be performed in
Maximum air humidity 75% accordance with the processing guidelines of the adhesive
The temperature of the subconstruction must be at least 3C manufacturer.
above the dew point temperature.
Joint
Joint width at least 8 mm.

Mount and edge distances

1,9

Fastening
1,8

1,7

1,6
Distance between supports (m)

1,5

1,4

1,3

1,2

1,1

1,0

0,9

0,8

0,7

0,6

0,5

0,4

0,3

0,2
0,00 0,50 1,00 1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00

Wind Load (kn)


13 mm 10 mm 8 mm

The maximum installation height is 22 m. In principle, the relevant country guidelines must be observed.

Multiple field plate Single field plate

l l

Mount and edge distances


d horizontal mount distance
d d b
b Maximum plate breadth 1200 mm
l Maximum plate length 3600 mm

53
Vertical joint Window embrasure

Internal corner External corner

Legend

A) fibreC cladding panel


B) Laying tape
C) Cladding adhesive

1) Masonry
2) Fastening Dowel
3) Thermal Separator
4) Wall bracket
5) Insulation
6) Fastening srew
7) Vertical profile
Note
8) Ventilation space All the visualisations in the brochure are schematic representations of the system and structural-physical requirements and project
details are not included in the data.