Sie sind auf Seite 1von 4

FAN COIL

Four-way cassette fan coil


MODEL FCB-034BCN2B* FCB-051BCN2B* FCB-068BCN2B* FCB-085BCN2B* FCB-102BCN2B*
H 340 510 680 850 1020
Air volume m/h M 280 420 560 700 840
L 210 300 420 520 620
H 2700 3550 4270 4980 5810
Cooling capacity W M 2354 3074 3675 4356 4943
L 2014 2660 3258 3696 4230
200-1200CFM H 4180 5660 6800 8100 9450
FCB 340-2380m3/h
Heating capacity W M 3511 4753 5848 7208 8315
L 3009 4075 5032 6155 7182
Power input W H 37 52 62 71 80
H 28 37 40 36 41
Noise level dB(A) M 26 32 31 32 35

FOUR-WAY CASSETTE FAN COIL Water flow l/min


L 24
7.7
28
10.2
23
12.3
28
14.4
31
16.7
Water pressure drop KPa 10 16 24 28 38
Net weight kg 21.5 21.5 21.5 33 33

HIGH EFFICIENCY Gross weight

Water inlet/outlet connection pipe


Condensate water connection pipe
kg 26.5 26.5

25
26.5
3/4" internal thread
42

20
42

External dimension(L*W*H) mm 570/570/260 840/840/204


Stylish and fashionable design
Trendy curves and contours
Beautiful curvy shapes MODEL FCB-136BCN2B* FCB-170BCN2B* FCB-204BCN2B* FCB-238BCN2B*
Pearl white piano lacquer nish panel H 1360 1700 2040 2380
Air volume m/h M 1120 1400 1650 1960
L 840 1000 1250 1480
H 7600 9200 11200 12600
New 360Smart Flow Cassette Cooling capacity W M 6579 8215 9663 11162

Unique 360 eight way air outlet, no blind spot L 5585 7132 8500 9763
H 12200 14800 18130 19950
Innovative 4 motors ,Independent air ow control M
Heating capacity W 11223 12727 15773 17356

FAN COIL
6 position blade adjustment L 9638 10952 14645 14962
Power input W H 115 152 180 228
H 44 48 50 52
High vertical air ow
Noise level dB(A) M 40 40 42 48
3.5m super high vertical air ow
L 34 33 34 43

Water flow l/min 21.8 26.4 32.1 36.2

Healthy function Industry leading super slim height Water pressure drop KPa 33 40 40 50
Net weight kg 37.5 37.5 42 42
Pre-set fresh air inlet can introduce the outside fresh air The new cassette height is only 204mm (3HP), Increase kg
Gross weight 47 47 52 52
into the room , improve the indoor air quality.(optional) your head room space
Water inlet/outlet connection pipe 3/4" internal thread
Fresh air Condensate water connection pipe 20
inlet
External dimension(L*W*H) mm 840/840/246 840/840/288

1. Cooling conditions: DB temperature=27C WB temperature=19.5C water IN=7C water IN/OUT Diff=5C.


2. Cooling conditions: DB temperature=21C water IN=60C.
204mm 3. The dats is subject to change without notice in order to update the design.
4. *Models are under development, data is pending
Ceiling concealed type (Standard type) specication
MODEL FCE-034BCN2A FCE-051BCN2A FCE-068BCN2A FCE-085BCN2A FCE-102BCN2A
H 340 510 680 850 1020
Air volume m/h M 290 430 580 720 850
L 230 340 460 560 680
H 2120 3040 3900 4820 5950
Cooling capacity W M 1781 2621 3354 4193 5296
L 1484 2215 2886 3519 4463
H 3534 4750 6300 7940 9800
200-1200CFM
FCE 340-2380m3/h
Heating capacity W M 2969 3990 5418 7067 8624
L 2544 3420 4662 6034 7448
H 24 32 50 61 81
Power input W
SH 42 50 65 95 110
SH 37 38 41 44 45
H 35 36 37 41 43
dB(A)

CEILING CONCEALED FAN COIL


Noise level
M 28 29 31 32 35
L 22 22 24 25 26
Water flow l/min 6 9.1 12.5 14 16.2
Water pressure drop KPa 10 16 18 23 35
Net weight kg 11.5 12 14.5 16 16.5
Gross weight kg 13 14 17 18.5 19
Fan coil unit is mainly composed of centrifugal fan, motor and evaporator Water inlet/outlet connection pipe 3/4" internal thread
Condensate water connection pipe 3/4" external thread
It is widely used in the eld such as hotel, restaurant, hospital, exhibition hall, oce building, industrial building, domestic External dimension(L*W*H)
mm 655/466/220 975/466/220
building, etc. It will provide you comfortable environment. (exclusive of drain pipe length)

Shipping dimension(L*W*H) mm 686/503/250 1006/503/250


Technical Features & Benets (Standard type)
MODEL FCE-136BCN2A FCE-170BCN2A FCE-204BCN2A FCE-238BCN2A
H 1360 1700 2040 2380
Air volume m/h M 1120 1420 1700 1980
L 880 1110 1320 1580
H 8300 9480 11720 13130
Cooling capacity W M 7138 8437 10314 11686
Luck button fan blower case Knock down V-shape drain pan Take out exchanger Fan motor
L 6059 7110 8790 9848
H 12755 15600 18700 21360
Security and reliability, long life High eciency, sucient energy Heating capacity W M 11735 13416 16269 18583

FAN COIL
Each set of fan coil evaporator will be tested leakage by pressure; The seamless pipe cross the slit n aluminum foil, then be L 10076 11544 14025 16020

enlarged by the mechanical device to make the copper pipe H 120 148 178 198
water inlet/outlet connection pipe adopts brass forging Power input W
and the aluminum foil together, which will get the higher SH 135 183 210 260
structure, reliable and endurable; the V-shape drain pan is made
SH 46 48 48 49
by mold and then treated with paint; It can be easily knocked eciency and sucient heating/cooling capacity.
H 43 46 48 48
down and installed on site; motor is equipped with the rolling Noise level dB(A)

bearing, The motor is equipped the rolling bearing, no need to


Universal application M 35 36 36 37
L 27 28 28 29
add oil, and its life can be up to 60,000 hours. Central axis of 1.The unit adopts the drawable heat exchanger, convenient Water flow l/min 23 26 34 38
motor has been thermal rened and surface anti-corrosion to maintain; optional left or right water inlet type, exible Water pressure drop KPa 46
35 38 39
installation; optional static external pressure 12Pa or 30Pa to
treated. Net weight kg 26 26.5 31 31
meet the personalized requirement. Gross weight kg 29 29.5 34.5 34.5
Large air volume and low noise level 2.The unit thickness is only 220mm, convenient for Water inlet/outlet connection pipe 3/4" internal thread
installation. Condensate water connection pipe 3/4" external thread
The unit adopts the locked type scroll casing, convenient
External dimension(L*W*H)a 1405/466/220 1665/466/220
to be taken down; Less space occupation (exclusive of drain pipe length)
mm

multiple-blade fan. There will be multiple combinations by Shipping dimension(L*W*H) mm 1436/503/250 1696/503/250
The total 9 models adopt 4 type dimension and the height of
the fan and the motor to meet the dierent requirements.
ceiling concealed duct type fan coil is only 220mm , saving
1. Cooling conditions: DB temperature=27C WB temperature=19.5C water IN=7C water IN/OUT Diff=5C.
space greatly. 2. Cooling conditions: DB temperature=21C water IN=60C.
3. The left water outlet type or right water outlelunit can be changed on site according to the actual repuirement.
4. The static pressure 12Pa and 30Pa can be selected freely accoring to the actual requirement.
5. The dats is subject to change without notice in order to update the design.
FAN COIL
Fan Coil Unit Diamension Fan Coil Unit Wiring Diagram
Water outlet& inlet mark

Fan coil wiring diagram

Super speed
High speed

Capacitance
Water inlet Water oulet Middle speed
(3/4Internal thread) (3/4Internal thread)
Motor 2 Low speed

Olivine
Earth wire

Super speed Red Super speed


High speed Blue

Capacitance
High speed
Middle speed
Black
Drain connectionn Motor 1 Middle speed
(3/4"External thread)
ead Low speed Orange
Low speed
Yellow
Neutral wire

The hoisting ring 4-1222 1.The connection between low, middle, high, super high speed on the terminal and
fan coil controller.
2.When ESP of air outlet is 12Pa, please connect low, middle, high speed terminal to
fan coil controller; when ESP is 30Pa, please connect middle, high, super high
Unit dimension diagram(mm)
Model Weight(kg) speed termial to fan coil controller, or users can adapt accordingly.
A B C
3.There are no moter No. 2 and corresponding wiring for single motor fan coil.
FCE-034BCN2A 624 508 478 11.5
FCE-051BCN2A 624 508 478 12
FCE-068BCN2A 944 808 778 14.5
FCE-085BCN2A 944 808 778 16
FCE-102BCN2A 944 808 778 16.5
FCE-136BCN2A 1374 1238 1208 26

FAN COIL
FCE-170BCN2A 1374 1238 1208 26.5
FCE-204BCN2A 1634 1498 1468 31
FCE-238BCN2A 1634 1498 1468 31

Das könnte Ihnen auch gefallen