Sie sind auf Seite 1von 11

List of Figures

Figure 1: The Petlyuk Column Configuration

No need of figure 1, remove

Figure 2: Divided Wall Column (DWC)

1
Figure 3: Algorithm for DWC design

2
What is brute force optimization?? Remove that word

Figure 4: Composition profile vs Tray position in first column of conventional distillation system

Change this figure, because side is not white

Figure 5: Shortcut Sloppy Configuration

No need of figure 5,

3
Figure 6: Process flow sheet of DWC after rigorous simulation in HYSYS

Figure 7: Temperature and Composition Profile vs. Tray Position for DWC Pre-fractionator (BTX mixture F2)

Change with white color side

4
Figure 8: Temperature and Composition Profile vs. Tray Position for DWC Main Column (BTX mixture F2)

Change with white color side

F1: Feed Mixture: (0.40, 0.20, 0.40)

Vapor flow = 120 kgmole/h

Liquid flow = 64.69 kgmole/h

Reboiler duty = 1506 kW

Optimal value

Vapor flow = 117 kgmole/h

Liquid flow = 71 kgmole/h

Reboiler duty = 1322 kW

Figure 9: Internal flow distribution effect on DWC Reboiler duty: BTX mixture (F1)

Make the table for data not in side box

5
F2: Feed Mixture: (0.33, 0.33, 0.34)
4000
Vapor flow = 125.4 kgmole/h
3500

3000 Liquid flow = 72.68 kgmole/h


Rebq

2500
Reboiler duty = 1483 kW
2000

1500 Optimal value


1000
160 Vapor flow = 123 kgmole/h
90
140 85
75
80 Liquid flow = 74 kgmole/h
120 70
65
60
Vapor101 out
100 55
Liquid101 out
Reboiler duty = 1470 kW

Figure 10: Internal flow distribution effect on DWC Reboiler duty: BTX mixture (F2)

Make the table for data not in side box

6
F3: Feed Mixture: (0.15, 0.70, 0.15)

Vapor flow = 90.32 kgmole/h

Liquid flow = 45.03 kgmole/h

Reboiler duty = 1277 kW

Optimal value

Vapor flow = 88.3129 kgmole/h

Liquid flow = 52.0347 kgmole/h

Reboiler duty = 12491 kW


Reb Q

Figure 11: Internal flow distribution effect on DWC Reboiler duty: BTX mixture (F3)

7
Make the table for data not in side box

Figure 12: Composition profile of DWC main column (20% lower energy): BTX mixture F2

8
2300
1550

2100 1530

1900 1510

Reboiler Duty (kW) Reboiler Duty (kW)


1700 1490

1500 1470

1300 1450
2 4 6 8 10 12 14 16 18 31 32 33 34 35 36 37 38 39 40

Feed Tray Location S ide Product Draw Tray Location


(1) (2)

Figure 13: Reboiler duty vs. (1) feed stage location and (2) Side draw location

Put the figures separately

1500

1480

1460
Reboiler Duty (kW)

1440

1420
25 26 27 28 29 30 31 32 33 34 35

Height of Dividing Wall (Trays )

Figure 14: Effect of wall height on reboiler duty

9
Product Purity vs. Reflux Ratio
1

0.9

0.8

0.7
Product Purity (mole fraction)
Benzene Toluene p-Xylene

0.6

0.5

0.4
2 3 4 5 6

Reflux Ratio

Figure 15: Effect of reflux ratio on DWC product purities

Product Purity vs. Feed Tray Location

0.98

0.96

0.94

Product Purity Benzene Toluene p-Xylene


0.92

0.9

0.88

0.86
7 8 9 10 11 12 13 14 15

Feed Tray Location

Figure 16: Effect of feed tray location on DWC product purities

10
Product Purity vs. Reboiler Duty

0.95

0.9

0.85
Product Purity (mole fraction)
Benzene Toluene p-Xylene

0.8

0.75

0.7
1300 1350 1400 1450 1500 1550 1600 1650 1700

Reboiler Duty (kW)

Figure 17: Effect of Reboiler duty on product purities

11