The document summarizes an issue with the magnetic bearing regulation in TruFlow lasers with an IMC15 controller. Mecos developed a dongle plug solution that solves the sporadic calibration, test, and position errors. Starting in November 2012, the dongle plug replacement part set was distributed to subsidiaries and representatives to retrofit lasers with IMC15 serial numbers up to and including AAZUO during regular service missions. The dongle plug solves the problem for damaged IMC15s but has no effect on newer IMC15s starting with serial number AAZUP.
The document summarizes an issue with the magnetic bearing regulation in TruFlow lasers with an IMC15 controller. Mecos developed a dongle plug solution that solves the sporadic calibration, test, and position errors. Starting in November 2012, the dongle plug replacement part set was distributed to subsidiaries and representatives to retrofit lasers with IMC15 serial numbers up to and including AAZUO during regular service missions. The dongle plug solves the problem for damaged IMC15s but has no effect on newer IMC15s starting with serial number AAZUP.
The document summarizes an issue with the magnetic bearing regulation in TruFlow lasers with an IMC15 controller. Mecos developed a dongle plug solution that solves the sporadic calibration, test, and position errors. Starting in November 2012, the dongle plug replacement part set was distributed to subsidiaries and representatives to retrofit lasers with IMC15 serial numbers up to and including AAZUO during regular service missions. The dongle plug solves the problem for damaged IMC15s but has no effect on newer IMC15s starting with serial number AAZUP.
Service news Series The supplier Mecos solved the problem in January
2010. For the IMC15 starting with AAZUP, the
problem no longer occurs. Date: 2013-02-08 Source: TCHB550lr, 2012-09-10 Contact person: SCC CO2 laser
IMC15: Error in the regulation of the
magnetic bearing
Lasers TruFlow Laser with IMC15 (magnetic bearing and
motor controller): TruFlow 3200-6000 V0 TruFlow 8000-15000, large product group TLF 2400t 5000t with LSM and retrofitted IMC15 Dongle plug CCK1 Fig. 65235 TLF 6000t 12000t with LSM and retrofitted IMC15 Measures Mecos developed a dongle plug which solves this required problem. Starting in November 2012, Sales is Problem The following errors occur sporadically: sending, bit by bit, the "dongle plug replacement part set" in sufficient quantity to all subsidiaries and At the start or at the self test of the IMC15: representatives. Calibration error (not calibrated). As soon as the replacement part sets are Errors with the self test drive (DrivePerm). available, in the course of service missions which Magnetic bearing position or integrator error take place anyway: (XFlt and/or ItFlt). 1. Shut down the laser and turn off the main Position error and field weakening error (XFlt + switch. DrFldWk). 2. Plug the dongle plug CCK1 into the free socket Internal under-voltage error (U15N_UN or "X1 ECA6/CAN" in the housing of the IMC. U15P_UN). Duration: ca. 20 min. Cause Defective electronic component in the sensor This measure can also be performed by the circuit of the magnetic bearing regulation. The customer. The retrofit instructions come with the problem first occurs after an operating time of replacement part set. about 4 years. This applies to IMC15 up to and The dongle plug solves the problem for IMC15s including serial number AAZUO. which are already damaged. i1088en.docx 1 If the dongle plug is unintentionally plugged into a new IMC15 (starting with serial number AAZUP) because it has no effect on the function. Mecos will bear the material costs. The TRUMPF subsidiary or the agency which performs the measure bears all of the costs.
SIS The project "IMC dongle plug CCK21" (ID 31123)
has been placed in the SIS. Document your measures in SIS or contact: service.scc-co2-laser@de.trumpf-laser.com.