Sie sind auf Seite 1von 6

srimallikarthik@gmail.

com
Sri Malli Karthik G Mob: 9902357239

EXPERIENCE SUMMARY

3 Years experience in Software & Hardware design and development of EMBEDDED systems
in Medical Domain.

 Experienced in all phases of Product development life cycle, including


Requirements analysis, Software design, Hardware development, Component
sourcing, System testing, System integration, IEC / UL standards compliance
testing, Test plan preparation.
 Exposure to product safety standards (IEC 60601-1) and CMMI quality process
model (SEI-CMMI Level5).
 Exposure to the design and architecture of real-time systems.
 Versed in risk management (ISO14971) and Usability (IEC60601-1-6).
 One patent received

HARDWARE PLATFORMS
Micro-Processors / Micro-Controllers
 Motorola-MC9S12A64
 AMD-AM188ER
 Atmel ATmega-640
 TI-MSP430
 OMAP3530

Peripherals: UARTS,I2C,SPI, RTC, SRAM, FLASH & EEPROMs

SOFTWARE
Design Methodology: SSAD and OOAD
Languages : C, C++
OS: Win CE, VxWorks

TOOLS
Compilers
 Metrowerks Code Warrior
 Paradigm C++ Pro
 IAR Embedded Workbench
 AVR Studio
 Visual Studio 2005

Design / Development Tools


 MS Visio, System Architect, Enterprise Architect

Page 1 of 6
Configuration tools
 MS Visual Source Safe.
 Splice-M
Others
 Lab Tool & SME EEPROM programmers
 Matlab
 MS Project
 HW: Logic Analyzer, Function Generator & CROs

PROFESSIONAL EXPERIENCE

Organization: L&T EmSyS (Embedded Systems & Software), Mysore


Job profile
As a Software Designer and Developer since June 2007, involved with following activities:
1. Sleek Monitor: 18-May-10 – till date
The purpose of the project is to design and develop software for a 10 channel multi-
parameter patient monitoring system for continuous monitoring of the physiological parameters 3/5L
ECG/12L ECG, RESP, NIBP, 2 TEMP, SPO2, CO2, 4 IBP, CO/NICO, ST Analysis, Arrhythmia detection and
interface to Thermal recorder, CNS, AGM 55 and USB storage device.
The PMS shall be a partially modular system, with in built parameters (ERTNS2P) and with an option to
plug any 3 externally parameter modules like CO2, 2IBP, CO, NICO, SpO2. The user interface shall be
designed for easy navigation using Touch screen and optical encoder based navigation.
The system shall have waveform and digital data display, 240 Hrs parameter trend, alarm detection
and indication capability. Remote viewing facility also shall be provided. The system shall have a 15”
display of 1024X768 resolution size.
Responsibilities:
 Developer
 Firmware development in C++
 Development of Recall Trend
 Development of Online Trend
Team Size : 13
Controller : OMAP3530
Language Used : C++
Design Methodology : Object Oriented Analysis and Design
Compiler : Visual Studio 2005
Tools used : Enterprise Architect

Major Contributions:
 BSP Modifications for 1-wire EEPROM, UARTs
 Trend module modifications for Sleek Design

Page 2 of 6
2. TC-Module: 15-April-09 – 18-May-2010
Complete product development. To make a module to measure Transcutaneous CO2,
Transcutaneous O2 and SPO2 and communicates to a Patient Monitoring System using a standard
protocol. Development of a PC side Application software for testing and debugging which acts as the
PMS. Development of PC side software for service personnel for field debugging and software
upgradation.
Responsibilities:
 Developer
 Firmware development in C++, Board bring-up & Testing
 Development of detailed Software and Hardware requirements from System Requirements
Specification
 Exploring and including safety and performance standards as applicable to the product
 Co-ordinate with PCB vendors, Cable harness manufacturers and component vendors for
procurement of the same
 Main Board Hardware development & Testing
 Co-ordination between teams
 Certification of the product (under IEC 60601 for FDA & CE)
 Risk Management Activities (IEC-14971)
 Product Usability Analysis and Design (IEC60601-1-6)
 Co-ordinate with the Mechanical Team for the mechanical designs and implementations
 Inventory management and monitor during the project
 Risk analysis and FMEA
 Testing for conformance to identified safety and performance standards.
 Preparation of Product and Technical file for CE marking
 Responsible for Pilot lot production
 Transfer of design to Production

Page 3 of 6
Team Size : 13 (Hardware: 3, Firmware: 2, Application: 3, Mechanical: 3, PSU: 2)
Controller : ATmega640 (Atmel)
Language Used : C++
Design Methodology : Object Oriented Analysis and Design
Compiler : IAR Embedded Workbench
Tools used : Enterprise Architect

Major Contributions:
 Main Board design
 Peripheral driver module for software (C++)
 EMI/EMC Testing and problem solving
 On-time delivery of prototypes

2. Comet-E: 1-July-08 – 10-Feb-09


To make a stand alone ECG for Comet-P which supports SPO2.
Responsibilities:
 Developer
 Implementation of Online Trend
 Making the Product work as stand alone for SPO2

Team Size : 7
Controller : AM188ER (AMD)
Language Used : C++
Design Methodology : Object Oriented Analysis and Design
Compiler : Paradigm C++ Pro
Tools used : System Architect, Font Generator

Major Contributions:

 ECG Module software: ECG Waveform plotting, Communication protocol implementation


and Alarm Handling.
 120 Minutes Online trend implementation
 Skyline 55 Interface

3. Comet-P: 1-Feb-08 - 15-Apr-08


To make a stand alone SPO2 for Comet-BP which supports both SPO2 and NIBP.
To add online trend of SPO2 and PR on the Front screen.

Page 4 of 6
Responsibilities:
 Developer
 Implementation of Online Trend in Comet-BP
 Making the Product work as stand alone for SPO2.

Team Size : 3
Controller : AM188ER (AMD)
Language Used : C++
Design Methodology : Object Oriented Analysis and Design
Compiler : Paradigm C++ Pro
Tools used : System Architect, Font Generator

Major Contributions:

 90 Minutes Online Trend implementation


 Thermal Recorder interface

4. Micromon - NxT: November 2007- December 2007

To incorporate Heart rate Trend in the existing Micromon-NT.

Responsibilities:
 Tester
 Testing Micromon – NxT for Implementation of Online Trend.

Team Size : 3
Controller : MC9S12A64 (Motorola)
Language Used : C
Compiler : Metrowerks Code Warrior

Major Contributions:
 Delivered the product on time with no defects reported from customer.
 Received the Best integrated Team award

Page 5 of 6
QUALIFICATION

2001 S.S.C
St.Mary’s E.M High school
% marks: 82
2001-2004 Diploma in Electronics & Communications
S.V.G.Polytechnic (Tirupathi)
% marks: 80.4
2004-2007 Bachelor of Engineering (Electronics & Communication Engineering)
S.V. Engineering College (Jawaher lal Nehru Technological University)
% marks: 73

Pursuing Master of Science in embedded system design with Manipal University, Bangalore

PERSONAL DETAILS

Date of Birth : 09-March-1986


E-mail Address : srimallikarthik@gmail.com
Contact number : +919902357239

Permanent address : 16-4-1444,


Harinathpuram,
Nellore (dt), A.P,
INDIA.

Page 6 of 6