Sie sind auf Seite 1von 36

hydro unit booster systems

dp pumps

technical data
INDEX
Clean water:
In general 01

Features
Controls DPC, MC
04
06
Booster systems:
Controls HU1, MCF, MCJ
Controls Pico, Palm
07
08 high-tech solutions
Model key 09

Technical data
Eco Hydro 10
HU1 11
HU2/3 DPC 14
HU2/3/4 MC 18 Transparency with Stainless
HU2/3/4 MCF 22 Steel
HU2/3/4 MCJ 26 DP Pumps is market leader in the market
HU + plus + 29 of booster systems and has been for quite
Accessories 30
some time. By means of innovative,
Notes 33
customized solutions.
From our service organisation we have a
continuous feedback.
This, combined with optimal commitment of
the employees and the natural urge to
continuously improve, makes the
booster systems very reliable and service
friendly.

Compact assembly
Building costs and exploitation costs of
high-rises are constantly increasing and the
volume of technical areas in buildings are
decreasing because of this.
As market leader in the booster systems
we have defined a new standard, as of
today:
The compact Hydro-Unit with the new
DPVE vertical pump.
The complete unit is compact and service
friendly.

No corrosion means cleaner


dp pumps is ISO-9001 water
and ISO-14001 certified. A large part of the distribution of our
potable water is done by booster systems,
which up to now were exclusively done by
pumps, partially made of cast iron.
Cast iron corrodes and will therefore,
specially after a period of inactivity, intro-
duce calcium and rust into the water.

02
transparency with Stainless Steel

Because all wetted parts of the DPV(S)


pumps are fabricated in stainless steel,
this problem does not exist any more.

Tailor made units


Besides our standard program we can
of course be of service with advice and
the design of customized installations.
Our technical advisors and engineers
are at your disposal.

03
FEATURES
Controls

DP-Control for
standard operation

Megacontrol for
comfort enhancement
and process optimi-
zation.

Frequency converter
for modulating
operation.

Pico-server for
optimized telemetry

Basic
configurations
HU+plus+ for maximum
energy savings and
limitation of switching
differential.

Frequency control for


process optimization or
systempressure
stabilization.

Level control for an


integral process
control.

04
FEATURES
The "new standard" is a complete booster
system in accordance with all relevant demands
of NEN1006 and VEWIN.

Through the use of standard modular assembly


of the installation, it is expandable with all
available options, to an installation, which is
completely in agreement with the demands of
the end-user.
according to process specifications for the
industry.
according to comfort specifications for the
building industry.

dp pumps www.dp-pumps.com
05
DP control units:
Optimized control,
DPC
simple application
MC
DP-Control Megacontrol
Hydro-Unit HU DPC Hydro-Unit HU MC
Our DP-Control is used in (standard) booster The Megacontrol is developed for the electronic
systems equipped with 2 or 3 pumps. control of a (standard) booster system equip-
The control and the accessibility of the program ped with 1 up to 6 pumps.
have been set to the basic functions: the DP- The Megacontrol has extensive possibilities for
Control is not equipped with a display but uses control and signalization of:
a number of LEDs that indicate the status of the existing pressures and levels
the unit without having any specialized know- the pump(s)
ledge of the the frequency converter
program or the level in the buffer tank and the control of
the control. the inlet valve (valve open/shut or in a
The error proportional position)
signalization the status of the installation
is very sim- the inlet pressure
ple; it has
been divi-
ded into two
separate
signals:
'urgent' and 'not urgent'. Errors that reset them-
selves and errors of components of which there
are more than one (e.g. an error of the spare
pump) are indicated as '"not urgent'.

The DP-Control can be equipped with an


RS232-port so that you may receive more
detailed information when errors indications or
status controls are required. Errors, status and In this control module, only the basic opera-
control will be indicated by completely defined tions are pre-set. At location the parameters of
codes. the system will be set to the specific situation.
Via the keyboard and display all the variable
By means of the membrane switches on the configurations and parameters are changeable.
DP-Control, pumps can be tested and the By means of passwords, these values are
status of the pump can be defined secured at three different levels against 'tres-
(manual-off-automatic). passers'.

06
Installation variables:
no situation is the same
HU1
MCF
Hydro-Unit HU1 Hydro-Unit HU MCJ MCJ
1-pump control Hydro-Unit with Megacontrol
The HU1 is a booster system with only a single and jockey pump
pump. In certain cases it is permissible to The HU MCJ booster system is suitable for
install a booster system without a spare pump. applications with extreme capacity fluctuations.
The 1-pump control of the Hydro-Unit HU1 is This system is equipped with a jockey pump.
only meant to lengthen the life cycle of the It is also possible to add a spare jockey pump.
installation, as opposed to the advanced con- The jockey pump is a smaller pump with a
trol in the DP-Control and Megacontrol. lower capacity but with the same head of
pressure as the main pumps in the installation.
Hydro-unit HU MCF
One pressure transmitter controls all the
Hydro-Unit with Megacontrol and pumps. The jockey pump is started first to
frequency converter supply the regular water consumption.
This Hydro-Unit booster system is equipped When the water consumption surpasses the
with pumps with a standard IEC motor. capacity of the jockey pump, one or more of
By means of a frequency converter one of the the main pumps will start automatically.
pumps will have its speed controlled. The jockey pump is shut down simultaneously.
This offers the following advantages: If the water consumption reduces again, the
- a saving of costs through lower energy main pumps will shut down and the jockey
consumption pump takes over again.
- useable when the inlet pressure supplied by
the water company varies greatly The selection of the jockey pump is based
- an extremely constant system-pressure upon the expected capacity during the so-cal-
led 'low consumption hours'. The main pumps
The Hydro-Unit HU MCF is equipped with the are selected for the capacity and pressure
Megacontrol module. At the pressure side of necessary during the 'high consumption hours'.
the installation, a pressure transmitter is instal- The number of pumps in the installation divi-
led which offers an analogue signal to the ding the total volume, is based upon the
Megacontrol to indicate the system pressure. capacity and the requested reliability of the
If this deviates from the set pressure, the system.
speed of the pump is automatically adjusted.
The reaction speed, as well as the precision of
the control of the pump speed is done by
means of a P.I.D. control. This is integrated in
the software of the Megacontrol processor.
The processor defines which pump will be
adjusted and which pump will be set at a fixed
speed, all simultaneously.

dp pumps www.dp-pumps.com
07
Telemetry: distance is no problem
PICO Palm
Pico-Server Palm
Telemetry module for internet. Controlling the Megacontrol by PALM top.
The in-house developed telemetry module: the The control module Megacontrol has a
Pico-Server. standard communications port through which
By means of any PC, via the Internet or LAN, it information can be exchanged.
is possible to access a booster system with This exchange of data can be used to control
Megacontrol remotely (anywhere in the world). the installation with a hand-held, the PALM top.
This makes the control and set-up of a system With the PALM-top you can:
simple. Through looking at the graphic visuali- set up the Megacontrol easily
zation of the trends, the status of the installa- memorise the set-up for multiple systems
tion can be made totally visual: search for errors rapidly by using simple test
system pressure functions
inlet pressure generate graphs
level in the tank lookup error data
pump power output
position of the filling valve The biggest advantage of the PALM top is the
visualization, possible through the graphic
The Pico-server allows more things to be con- display.
trolled remotely: Also much attention has been given to the
visualization and alteration of the menu-driven functions, of which high user
configuration friendliness is the result. On the graphic display
downloading log files of the PALM top many characters can be visu-
treatment of errors. alized. This makes it possible for the PALM top
Technical to function in a non-western language.
specifications
The Pico-Server PALM-software
is a complete The accompanying
Internet server PALM software
based on a enhances the con-
Pentium 586 sin- trol and test functi-
gle board PC. ons of the
We deliver the Megacontrol.
Pico-Server complete with powersupply, The large display
modem (or LAN-connector) and RS 232-con- makes the parame-
nector to the Megacontrol. ter menu very clear
The whole unit is built into an industrial hou- and all parameter
sing. There are no minimal specifications for settings of the vari-
the Internet PC (an internet browser should be ous locations can
installed). be stored and loaded from the PALM memory.
The complete application software is generated Lots of time can be saved because one can
by the PICO, you don't have to install anything. intervene directly on the Megacontrol outputs
for simple field-tests and simulations. The pro-
gram is, as usual with PALM software, very
compact (programmed in C) and can be sent
easily by using e-mail.

08
MODEL KEY

HU 1 DPV 4-30 NO 5/4 35


HU 2 DPVE 2-40 DPC 1 35
HU 4 DPV 18-60 MCF 2 80

HU unit type HYDRO-UNIT

2 number of pumps

DPV 18-60 pump types

N standard version

controlled by
DPC
DP-Control
controlled by
MC
Megacontrol
controlled by Megacontrol
MCF
and frequencyconverter
controlled by Megacontrol
MCJ
and Jockey pomp
shut-off-and
2
non-return valves

80 header

dp pumps www.dp-pumps.com
09
ECO HYDRO
Eco Hydro-Unit
Hydro-Unit with 1 pump, type DPV 2 or
DPV 4 suitable for drinking water.
Installed with pressure / flow control.

The Hydro Unit booster set is a high grade


product, with all wetted parts made of
non-corrosive materials. The installation is
completely pre-fabricated, wired, pre-adjusted,
factory tested and ready for use.

Construction:
Unit specially constructed for drinking water
applications.

Options:
Different voltages, protection classes,
specifications of materials for pumps,
valves and manifolds. Specifications:
Control systems and numbers of Vertical multistage centrifugal pump,
pumps customer specified. type DPV2 or DPV4,
with built-in thermal protection switch with
manual reset.
Low pressure protection switch with
manual reset.
Throttle valve control with the
following functions:
immediate cut-in at pressure drop
delayed switch-off at pressure rise

A V H1
HU1 DPV2-20 MS R1" AISI304 R1" 479
HU1 DPV2-30 MS R1" AISI304 R1" 500
HU1 DPV2-40 MS R1" AISI304 R1" 545
HU1 DPV2-50 MS R1" AISI304 R1" 566
HU1 DPV4-20 MS R1" AISI304 R1" 479
HU1 DPV4-30 MS R1" AISI304 R1" 524

MS = Brass
ASIS304 = Stainless steel 304
A = Fittings
V = Piping

10
HU 1
Hydro-Unit
Hydro Unit with 1 pump and membrane
tank, suitable for drinking water.
Installed with time dependant
pressure control.
The Hydro Unit booster set is a high grade
product, with all wetted parts made of noncor-
rosive materials.
The installation is completely pre-fabricated,
wired, preadjusted, factory tested and
ready for use.

Construction:
Unit specially constructed for drinking water
Specifications:
applications.
Vertical multistage centrifugal pump, type DPV.
One spring-loaded non-return valve and one
Options:
shut-off valve.
Different voltages, protection classes,
Membrane tank suitable for drinking water.
specifications of materials for pumps,
Pressure reference switch with 30kPa (4.35psi)
valves and manifolds.
differential.
Control systems and numbers of
Pressure gauge, classe 1.6.
pumps customer specified.
The control panel has the following functions:
Thermal motor protection switch
Manual-0-automatic switch
Run-dry protection
Failure indication "thermally-off" and "no
water"
Adjustable run-on time

dp pumps www.dp-pumps.com 11
HU 1 N

MS = Brass
AISI316 = Stainless steel 316
A = Fittings
V = Piping

12
HU 1 N

MS = Brass
AISI316 = Stainless steel 316
A = Fittings
V = Piping

dp pumps www.dp-pumps.com
13
HU DPC

HYDRO-UNIT
Booster system with 2 or 3 pumps
provided with DP-Control.

The Hydro Unit booster set is a high grade


product, with all wetted parts made of non-
corrosive materials. The installation is
completely pre-fabricated, wired, preadjusted,
factory tested and ready for use.

Construction:
Specifications:
Unit specially constructed for drinking water
Vertical multistage centrifugal pumps,
applications.
type DPV.
Per pump one spring-loaded check-valve and
Options:
two shut-off valves.
Control panel equipped with
Headers for parallel configuration of the pumps.
tensionfree contacts for error
Membrane tank suitable for drinking water.
reporting, divided into "urgent" and
Pressure reference switch with 30kPa (4.35psi)
"non- urgent"
differential.
Different voltages, protection classes,
Pressure gauge, class 1.6.
specifications of materials for pumps,
The complete unit mounted on an epoxy
valves and manifolds.
covered base-plate.
Control systems and numbers of
pumps customer specified.
The control panel has the following functions:
door-interlocked mains switch
thermal motor protection switches
DP-Control microprocessor control module
with the following basic functions:
optimized pump change-over
automatic optimizing run-on time
24-hours exercise run
adjustable delay of run-dry protection
LED indication:
- pump on (per pump)
- pump failure (per pump)
- power available / pumps on stand-by

14
HU 2/3 DPVE 2/4 DPC

A V H1 H2 H3 L1 B1 B2 B3
HU 2 DPVE2 MS R1" Cu 35mm 998 90 90 520 163 210 148
HU 2 DPVE4 MS R1" Cu 35mm 998 90 90 520 163 210 148
HU 2 DPVE4 MS R1" Cu 42mm 998 90 90 520 166 210 151
HU 3 DPVE2 MS R1" Cu 42mm 998 90 90 740 166 210 151
HU 3 DPVE4 MS R1" Cu 42mm 998 90 90 740 166 210 151
HU 3 DPVE4 MS R1" Cu 54mm 998 90 90 740 172 210 157

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2 or 3 pumps, type DPVE 2 with
A = Fittings motors up to and including 0,75kW (1,0HP). DPVE
V = Piping 4 with motors up to and including 1,1kW (1.5HP).

dp pumps www.dp-pumps.com
15
HU 2/3 DPV 2/4/10/14/18 DPC

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2 or 3 pumps, type DPV 2, 4, 10, or
A = Fittings 18 with motors up to 2,2kW (3.0HP). DPV 14
V = Piping equipped with motor up to 1,5 kW (2.0HP).

16
HU 2/3 DPV 24/32/45 DPC

A V H1 H2 H3 L1 B1 B2 B3
HU 2 DPVF24 GY NW65 Cu NW80 1250 155 155 800 251 450 374
HU 2 DPVF32 GY NW65 Cu NW80 1250 155 155 800 251 450 374
HU 2 DPVF45 GY NW80 Cu NW100 1250 155 155 800 274 450 417
HU 3 DPVF24 GY NW65 Cu NW100 1250 155 155 1200 264 450 387
HU 3 DPVF32 GY NW65 Cu NW100 1250 155 155 1200 264 450 387
HU 3 DPVF45 GY NW80 Cu NW125 1250 155 155 1200 287 450 431

GY = Cast iron Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2 or 3 pumps, type DPVF 24, 32 or
A = Fittings 45 with motors up to and including
V = Piping 7,5kW (10.1HP).

dp pumps www.dp-pumps.com
17
HU 2/3/4/.. MC

Hydro-Unit
Booster system with 2, 3 or 4 pumps
provided with Megacontrol.

The Hydro Unit booster set is a high grade


product, with all wetted parts made of non-
corrosive materials. The installation is
completely pre-fabricated, wired, preadjusted,
factory tested and ready for use.

Construction:
Unit specially constructed for drinking water
applications.
Specifications:
Vertical multistage centrifugal pumps, type
DPV.
Options:
Per pump one spring-loaded check-valve and
Control panel equipped with
two shut-off valves.
tensionfree contacts for error
Headers for parallel configuration of the pumps.
reporting, divided into "urgent" and
Membrane tank suitable for drinking water.
"non- urgent"
Analogue pressure sensor for system pressure.
Different voltages, protection classes,
The complete unit mounted on an epoxy cov-
specifications of materials for pumps,
ered base-plate.
valves and manifolds
The control panel has the following functions:
Control systems and numbers of
Door-interlocked mains switch
pumps customer specified.
Thermal motor protection switches
Megacontrol microprocessor control module
with the following basic functions:
Optimized pump change-over
Continuously optimized pump run-on timer
Adjustable system pressure-loss correction
factor
24-hours exercise run
Adjustable delay of run-dry protection
Text display:
- actual system values (system-pressure,
pump load and water supply info)
- pump status (automatic, manual and dis
abled)
- run time (per pump)
- complete error interface (with help text)
- easy parameter menu structure (access
through password)
- communications port RS232 with PC-,
Palm- and Internet software

18
HU 2/3/4/.. DPV 2/4 MC

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPV 2 or 4
A = Fittings with motors up to and including 2,2kW (3.0HP).
V = Piping

dp pumps www.dp-pumps.com
19
HU 2/3/4/.. DPV 10/14/18 MC

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPV10, 14 or
A = Fittings DPV18 with motors up to and including 2,2kW
V = Piping (3.0HP).

20
HU 2/3/4/.. DPV 24/32/45 MC

A V H1 H2 H3 L1 B1 B2 B3
HU 2 DPVF24 GY NW65 Cu NW80 1550 155 155 1200 251 450 374
HU 2 DPVF32 GY NW65 Cu NW80 1550 155 155 1200 251 450 374
HU 2 DPVF45 GY NW80 Cu NW100 1550 155 155 1200 274 450 417
HU 3 DPVF24 GY NW65 Cu NW100 1550 155 155 1600 264 450 387
HU 3 DPVF32 GY NW65 Cu NW100 1550 155 155 1600 264 450 387
HU 3 DPVF45 GY NW80 Cu NW125 1550 155 155 1200 287 450 431
HU 4 DPVF24 GY NW65 Cu NW125 1550 155 155 2000 278 450 401
HU 4 DPVF32 GY NW65 Cu NW125 1550 155 155 2000 278 450 401
HU 4 DPVF45 GY NW80 AISI316 NW150 1550 155 155 2000 305 450 449

GY = Cast iron Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPVF 24, 32 or
AISI 316 = Stailess steel 316 45 with motors up to and including
A = Fittings 7,5kW (10.1HP).
V = Piping

dp pumps www.dp-pumps.com
21
HU 2/3/4/.. MCF

Hydro-Unit
Booster system with 2, 3 or 4 pumps
provided with frequency converter and
Megacontrol.

The Hydro Unit booster set is a high grade


product, with all wetted parts made of non-
corrosive materials. The installation is
completely pre-fabricated, wired, preadjusted,
Specifications:
factory tested and ready for use.
Vertical multistage centrifugal pumps, type DPV
Per pump one spring-loaded check-valve and
Construction:
two shut-off valves.
Unit specially constructed for drinking water
Headers for parallel configuration of the pumps.
applications.
Membrane tank suitable for drinking water.
Analogue pressure sensor for suction pressure.
Options:
The complete unit mounted on an epoxy
Control panel equipped with
covered base plate.
tensionfree contacts for error
reporting, divided into "urgent" and
The control panel has the following functions:
"non- urgent"
Door-interlocked mains switch
Different voltages, protection classes,
Thermal motor protection switches
specifications of materials for pumps,
Megacontrol microprocessor control module
valves and manifolds
with the following basic functions:
Control systems and numbers of
Optimized (speed controlled) pump change-
pumps customer specified.
over
Continuously optimized P.I.D. regulation for
system pressure stabilization
Adjustable system pressure-loss correction
factor
24-hours exercise run
Adjustable delay of run-dry protection
Text display:
- actual system values (system-pressure,
pump load and water supply info)
- pump status
(automatic, manual and disabled)
- run time (per pump)
- complete error interface (with help text)
- easy parameter menu structure (access
through password)
- communications port RS232 with PC-,
Palm- en Internet software
Frequency converter, type VLT2800, brand
Danfoss, for modulating all of the system
connected pumps.

22
HU 2/3/4/..DPV 2/4 MCF

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPV 2 or 4
A = Fittings with motors up to and including 2,2kW (3.0HP).
V = Piping

dp pumps www.dp-pumps.com
23
HU 2/3/4/.. DPV 10/14/18 MCF

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPV10, 14 or
A = Fittings DPV18 with motors up to and including 2,2kW
V = Piping (3.0HP).

24
HU 2/3/4/.. DPV 24/32/45 MCF

A V H1 H2 H3 L1 B1 B2 B3
HU 2 DPVF24 GY NW65 Cu NW80 1550 155 155 1200 251 450 374
HU 2 DPVF32 GY NW65 Cu NW80 1550 155 155 1200 251 450 374
HU 2 DPVF45 GY NW80 Cu NW100 1550 155 155 1200 274 450 417
HU 3 DPVF24 GY NW65 Cu NW100 1550 155 155 1600 264 450 387
HU 3 DPVF32 GY NW65 Cu NW100 1550 155 155 1600 264 450 387
HU 3 DPVF45 GY NW80 Cu NW125 1550 155 155 1200 287 450 431
HU 4 DPVF24 GY NW65 Cu NW125 1550 155 155 2000 278 450 401
HU 4 DPVF32 GY NW65 Cu NW125 1550 155 155 2000 278 450 401
HU 4 DPVF45 GY NW80 AISI316 NW150 1550 155 155 2000 305 450 449

GY = Cast iron Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPVF 24, 32 or
AISI 316 = Stainless steel 316 45 with motors up to and including
A = Fittings 7,5kW (10.1HP).
V = Piping

dp pumps www.dp-pumps.com
25
HU 2/3/4/. . MCJ

Hydro-Unit
Booster system with jockey pump
provided with Megacontrol.

The Hydro Unit booster set is a high grade


product, with all wetted parts made of non-
corrosive materials. The installation is
completely pre-fabricated, wired, preadjusted,
factory tested and ready for use.

Construction:
Unit constructed in accordance with NEN
1006 and supplementary requirements of Specifications:
VEWIN.WB 4.3 Vertical multistage centrifugal pumps, type DPV
Per pump one spring-loaded check-valve and
Options: two shut-off valves.
Control panel equipped with Headers for parallel configuration of the pumps.
tensionfree contacts for error Membrane tank suitable for drinking water.
reporting, divided into "urgent" and Analogue pressure sensor for system pressure.
"non- urgent" Analogue pressure sensor for suction pressure.
Different voltages, protection classes, The complete unit mounted on an epoxy
specifications of materials for pumps, covered base-plate.
valves and manifolds The control panel has the following functions:
Control systems and numbers of Door-interlocked mains switch
pumps customer specified. Thermal motor protection switches
Megacontrol microprocessor control module
with the following basic functions:
Jockey pump control
Optimized pump change-over
Continuously optimized pump run-on timer
Adjustable system pressure-loss correction
factor
24-hours exercise run
Adjustable delay of run-dry protection
Text display:
- actual system values (system-pressure,
pump load and water supply info)
- pump status
(automatic, manual and disabled)
- run time (per pump)
- complete error interface (with help text)
- easy parameter menu structure (access
through password)
- communications port RS232 with PC-,
Palm- and Internet software

26
HU 2/3/4/..DPV 10/18 MCJ

A A V H1 H2 H3 L1 B1 B2 B3
HU 2 DPV10 MS R6/4" DPV2 MS R1" Cu 54mm 1250 130 130 800 96 450 231
HU 2 DPV10 MS R6/4" DPV4 MS R5/4" Cu 54mm 1250 130 130 800 96 450 231
HU 2 DPV18 MS R2" DPV2 MS R1" Cu NW65 1250 140 140 800 137 450 292
HU 2 DPV18 MS R2" DPV4 MS R5/4" Cu NW65 1250 140 140 800 137 450 292
HU 3 DPV10 MS R6/4" DPV2 MS R1" Cu 54mm 1250 130 130 1200 96 450 231
HU 3 DPV10 MS R6/4" DPV4 MS R5/4" Cu 54mm 1250 130 130 1200 96 450 231
HU 3 DPV18 MS R2" DPV2 MS R1" Cu NW65 1250 140 140 1200 137 450 292
HU 3 DPV18 MS R2" DPV4 MS R5/4" Cu NW65 1250 140 140 1200 137 450 292
HU 4 DPV10 MS R6/4" DPV2 MS R1" Cu NW65 1250 130 130 1600 103 450 238
HU 4 DPV10 MS R6/4" DPV4 MS R5/4" Cu NW65 1250 130 130 1600 103 450 238
HU 4 DPV18 MS R2" DPV2 MS R1" Cu NW80 1250 140 140 1600 150 450 305
HU 4 DPV18 MS R2" DPV4 MS R5/4" Cu NW80 1250 140 140 1600 150 450 305

MS = Brass Dimensional sketch for Hydro-Unit booster set,


Cu = Copper equipped with 2, 3 or 4 pumps, type DPV 10 or
A = Fittings DPV 18 with motors up to and including 7,5kW
V = Piping (10,1HP).

dp pumps www.dp-pumps.com
27
HU 2/3/4/.. DPV 24/32/45 MCJ

A A V H1 H2 H3 L1 B1 B2 B3
HU 2 DPVF24 GY NW65 DPV14 MS R5/4" Cu NW80 1550 155 155 800 251 450 374
HU 2 DPVF32 GY NW65 DPV10 MS R6/4" Cu NW80 1550 155 155 800 251 450 374
HU 2 DPVF32 GY NW65 DPV18 MS R2" Cu NW80 1550 155 155 800 251 450 374
HU 2 DPVF45 GY NW80 DPV10 MS R6/4" Cu NW100 1550 155 155 800 274 450 417
HU 2 DPVF45 GY NW80 DPV18 MS R2" Cu NW100 1550 155 155 800 274 450 417
HU 3 DPVF24 GY NW65 DPV14 MS R5/4" Cu NW80 1550 155 155 1200 251 450 374
HU 3 DPVF32 GY NW65 DPV10 MS R6/4" Cu NW80 1550 155 155 1200 251 450 374
HU 3 DPVF32 GY NW65 DPV18 MS R2" Cu NW80 1550 155 155 1200 251 450 374
HU 3 DPVF45 GY NW80 DPV10 MS R6/4" Cu NW100 1550 155 155 1200 274 450 417
HU 3 DPVF45 GY NW80 DPV18 MS R2" Cu NW100 1550 155 155 1200 274 450 417
HU 4 DPVF24 GY NW65 DPV14 MS R5/4" Cu NW100 1550 155 155 1600 264 450 387
HU 4 DPVF32 GY NW65 DPV10 MS R6/4" Cu NW100 1550 155 155 1600 264 450 387
HU 4 DPVF32 GY NW65 DPV18 MS R2" Cu NW100 1550 155 155 1600 264 450 387
HU 4 DPVF45 GY NW80 DPV10 MS R6/4" Cu NW125 1550 155 155 1600 287 450 431
HU 4 DPVF45 GY NW80 DPV18 MS R2" Cu NW125 1550 155 155 1600 287 450 431

GY = Cast iron Dimensional sketch for Hydro-Unit booster set,


MS = Brass equipped with 2, 3 or 4 pumps, type DPVF 24, 32 or
Cu = Copper 45 with motors up to and including
A = Fittings 7,5kW (10.1HP).
V = Piping

28
HU + PLUS +
Hydro-Unit+plus+
For optimal energy savings.

Construction:
The tanks have been specially constructed
for their application in potable-water
installations and do not leave any taste,
color or smell in the medium. Through the
difference in switching-pressures of the
installation, it is guaranteed to totally refresh
the water, through the filling and emptying of
the tanks.

Specifications:
The most energy efficient system on the market
today can be created by adding two
membrane tanks.
Every second that the pump is running, the
maximum efficiency is used.
Various measurements have shown energy
savings of 30 to 40%.
We can send you these reports when on
request.
The nominal pressures remain constant and
are independent of the variations in the piping.
The switching on of more than one pump is
avoided at peak usage.
The Hydro-Unit+plus+ system is delivered
complete with connections, shut-off valves,
couplings and drain.
All standard, new and existing booster sets, are
easily upgraded with the Hydro-Unit+plus+ sys-
tem.
The Hydro-Unit+Plus+ system will be calculat-
ed and completely designed for the
specific application for each unit, by
our technical advisors.

Maattabel: Inhoud D H DN Werkdruk Gewicht


[l] [mm] [mm] ["] [kPa] [kg]
DE 60 45 409 740 1 1000 18
DE 80 60 480 730 1 1000 20
DE 100 75 480 840 1 1000 25
DE 200 150 634 980 5/4 1000 43
DE 300 200 634 1280 5/4 1000 48
DE 500 375 740 1485 5/4 1000 79

dp pumps www.dp-pumps.com
29
ACCESSORIES
Flexible couplings
The flexible couplings are specially designed
for drinking water applications and approved by
the drinking water laboratories on non toxico-
logical aspects.
Besides the absorption of vibrations it also
compensates pipe expansion due to tempera-
ture changes.

Rubber flexible couplings


flange connections

Rubber quality : EPC


Connections : PN10
Dimensions : NW40 to NW250
Max. working pressure : 1600 kPa
Max. temperature : 95C

Rubber flexible couplings


thread connections

Rubber quality : EPC


Connections : brass
Dimensions : 3/4" to 2"
Max. working pressure : 1200 kPa (3/4")
900 kPa (1")
900 kPa (5/4")
700 kPa (6/4")
700 kPa (2")
Max. temperature : 70C DN D LF E2
40 150 130 20
50 165 130 20
65 185 130 20
80 200 130 20
100 220 130 20
125 250 130 20
R L D 150 285 130 22
3/4" 212 50 200 340 130 22
1" 218 55 250 405 130 22
5/4" 226 66
6/4" 226 94
2" 235 105

30
ACCESSORIES

A B C
3/4" 212 20
1" 218 20
Stainless steel flexible couplings
5/4" 226 20
thread connections
6/4" 226 20
Steel quality :Stainless steel AISI 304
Connections :Stainless stee AISI 304 2" 285 25
Dimensions :3/4" to 2" male
Max. working pressure :1600 kPa
Max. temperature :90C

Pressure reducing valve


The reducing valve, type D is applicable for
reducing the pressure of cold and hot water up
to 70C.

50-200 kPa R 1/2" R 3/4" R 1" R 5/4" R 6/4" R 2"


[mm] 15 22 28 35 42 54
L 140 160 180 200 225 255
H (D 06 F & D 06 FH) 96 96 140 140 172 172
H (D 06 FN) 148 148 185 185 210 210
h (D 06 F) 58 58 88 88 126 126
h (D 06 FH & D 06 FN) 54 54 72 72 82 82

Type Dimensions Inlet pressure Outlet pressure


D06F- standard version 1/2", 3/4" max. 2500 kPa 150-600 kPa
1" t/m 2" max. 1600 kPa 150-600 kPa
D06FH- high outlet pressure 1/2" t/m 2" max. 1600 kPa 150-1200 kPa
D06FN- low outlet pressure 1/2" t/m 2" max. 1600 kPa 50-200 kPa

dp pumps www.dp-pumps.com
31
ACCESSORIES
Rubber pad
To fill out floor roughness and eliminate sound
transmission, it is essential to use "silent
blocks" or for bigger and heavier units rubber
pads.

Silent blocks
Rubber quality : NBR
Dimensions D x H : 40 x 50 mm 70 shore A
: 40 x 28 mm 55 shore A
Thread : M8

standard dimensions B x L

B = 400 mm L = 400 mm

B = 500 mm L = 1000 / 1250 / 1590 / 1910 mm Type H D L G

B = 650 mm L = 1250 / 1590 / 1910 / 2250 mm 70-40x50 50 40 15 M8


55-40x28 28 40 23 M8

32
NOTES

dp pumps www.dp-pumps.com
33
NOTES

dp-pumps reserves the right


to make modifications without
prior notice.
All specifications could be
subject to change.

34
NOTES

dp pumps www.dp-pumps.com
35
dp pumps

dp pumps
P.O.Box 28
2400 AA Alphen aan den Rijn
Holland

t +31 172 48 83 25
f +31 172 46 89 30

dp@dp-pumps.com
www.dp-pumps.com

97004419/04-03

Das könnte Ihnen auch gefallen