Sie sind auf Seite 1von 24

Company Name

Equipment
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture
CHECK LIST FOR MOBILE ASPHALT PAVER

S| CHECK ITEM BA N GOO REMA


N D A D RK
1 STRUCTURE
2 WHEEL NUTS
3 TYRES
4 TRANSMISSION
5 ENGINE SOUND
6 GOVERNOR
7 FUEL GUAGE
8 OIL LEVEL GUAGE
9 RADIATION
10 CONTROL MECHANISM
11 TEMPRATURE GUAGE
12 ELECTRIC DEVICES
13 PIN, SHAFTS, LOCKING DEVICES
14 BRAKE AND CLUTCH SYSTEM
15 BRAKE LEFT
16 TRAFIATORS
17 SPEEDOMETER
18 REVERSE LIGHT
19 REARE LIGHT
20 HEAD LIGHT
21 PARKING LIGHT
22 HORN
23 REVERSE ALARM
24 AUGER
25 FLOW GATES
26 OPERATORS CABIN
27 SLAT CONVEYOR
28 HOPPER WINGS
29 SLAT FEEDERS
30 SCREED VIBRATOR
31 OVER HEAD PROTECTION
32 PANEL INSTRUCTION
33 HOPPER GATES
34 SCREADERS SCREWS
35 WHEELED TRACKS
36 SCREED HEATER
37 SCREED PLATES
38 OSCILLATING SCREED
39 VIBRATING COMPACTOR
40 SHUTTLE BUGGY
41 INSURANCE CERTIFICATE
42 COMPETENCE PERMIT
43 SURVEY CERTIFICATE
CHECKLIST FOR MOBILE BACKHOE

Company Name
Equipment
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S| CHECK ITEM BA N GOOD REMAR


N D A K
1 START|STOP SWITCH
2 LIFTING|TILTING OPERATION
3 TRACKS |TIRES
4 ANCHOR PINS
5 ENGINE CONDITION
6 BATTERY CONDITION
7 REVERSE ALARM
8 ENGINE COVERS
9 LIGHTS
10 HORN
11 SIDE MIRRORS BRAKE
12 OPERATORS COMPARTMENTS
13 OPERAORS STEP
14 OPERATORS SEAT
15 SEAT BELT
16 WIPER
17 SAFE WORKING LOAD (SWL)
18 BOOMING SLEWING OPERATION
19 OUTRIGGERS
20 OTHERS SPECIFY
21 OPERATORS COMPETENCE CERT
22 DRIVERS LICENSE
23 SURVEY CERTIFICATE
24 SPDC DRIVING PERMIT
25 MAINTENANCE RECORD
26 MAINTENANCE CHART
27 LOG 174 NON HAZ REQUIREMENTS
28 NO OIL |FUEL LEAKS
29 FUEL | OIL SPILL CONTAINMENT
30 LEAK FREE EXHAUST
31 FIRE RESISTANT FUEL LINES
32 FUEL TANK ISOLATION| CUT OFF VALVE
33 FRAS COOLING FAN BELT
34 NON METALLIC COOLING FANS
35 FULLY CHARGED, SECURED BATTERY
36 PROPER ELECTRICAL CONNECTIONS
37 AIR INLET SHUTDOWN VALVE
38 EMERGENCY STOP
39 IOG 174 ZONE:2 REQUIREMENTS
40 SURFACE TEMPRATURE LESS THAN 250C
41 INLET FLAME ARRESTER (FLAME TRAP)
42 INLET AIR SHUT OFF VALVE ACTIVATES ON
43 HIGH EX TEMP
44 ENGINE SPEED
45 HIGH COOLANT TEMP
46 LOW LUB OIL PRESSURE
47 EXHAUST SPARK ARRESTER NO|WIRE|
EN|USDA
48 NON ELECTRICAL STARTING
49 ZONE:2 CERTIFIED ELECTRICAL EQUIPMENT

CHECKLIST FOR MOBILE WATER DRILLING


Company Name
Equipment
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/N CHECK LIST BA NA GOO REMA


D D RK
START/STOP SWITCH
ELECTRICAL CABLES
BATTERY TERMINAL/BASE
GUARDS FOR ROTATING PARTS
RAMS OUTRIGGERS
DRAIN TAP
PUMP ISOLATION DEVICE
HOSES/COUPLINGS
CONTROL LIVERS
HOISTING OPERATION WELDED JOINTS
GENERAL MAST/STAND STRUCTURE
BRAKES
SAFTY CLIPS/PINS
ANCHOR POINTS
BOLTS/NUTS
DEAD LINE STABILIZER
SAFETY LATCH
SWL
OTHERS SPECIFY
DOCUMENTATON
MAINTENANCE PLAN/RECORD
OPERATORS COMPETENCE
SLING/ROPE CERTIFICATION
SURVEY CERTIFICATE
NDT CERTIFICATE
IOG 174 NON HAZ REQUIREMENTS
NO OIL/FUEL LEAK
LEAK FREE EXHAUST
FUEL/OIL SPILL CONTAINMENT
FIRE RESISTANT FUEL LINES
FUEL TANK ISOLATION/ CUT OFF VALVE
FITTED FREE
FRAS COOLING FAN BELT
FULLY CHARGED,SECURED BATTERY
PROPER ELECTRICAL CONNECTIONS
ELECTRICAL BONDING /2X6MM WIRE BONDS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP

IOG 174 ZONE-2 REQUIREMENS


SURFACE TEMPRATURE LESS THAN
250C/INSULATED EXUST
INLET FLAME ARRESTER (FLAME TRAP)
AUTO SHUT DOWN OR FULLY < MANNED>
INLET AIR SHUT OFF VALVE ACTIVATES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LUB OIL PRESSURE
EXHAUSTSPARK ARRESTER , NO / WIRE / EN
/ USDA
NON ELECTRICAL STARTING
NON METLLIC RDIATOR FAN
ZONE- 2 CERTIFIED ANCILLARY EQUIPMENT
AND GAUGES

CHECKLIST FOR MOBILE POWER PACK


Company Name
Equipment
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK LIST BA N GOO REMAR


N D A D K
START/STOP SWITCH
BATTERY/TERMINALS/CLAMPS
CONNECTING WIRES
GUARD FOR ROTATING PARTS
FAN BELT
FUEL LINE
FUEL/TANK COVER
RADIATOR COVER
METAL WORK BONDING SECURED
CONDITION OF DRUM
SAFETY CATCH PINS
WIP CHECK
WORKING PRESSURE
MAX WORKING PRESSURE
PRESSURE GAUGE
DRAIN-TAP
HOSE
PRESSURE RELIEIF VALVE
CONTROL VALVE
CLIPS AND COUPLINGS
OPERATORS CABIN
CONDITION OF WIRE LINES
OVERALL APPEARANCE/HOUSE KEEPING
PURE EXTINGUISHER

DOCUMENTATION
MAINTENANCE RECORD
CALIBRATION CERT
SURVEY CERTIFICATE

IOG 174 NON HAZ REQUIREMENT


NO OIL/FUEL LEAK
LEAK FREE EXHAUST
FUEL/OIL SPILL CONTAINMENT
FIRE RESISTENT FUEL LINES
FUEL TANK ISOLATION / CUT OFF VALVE
FITTED FREE
FRAS COOLING FAN BELT
FULLY CHARGED,SECURED BATTERY
PROPER ELECTRICALCONNECTIONS
ELECTRICAL BONDING / 2x6mm WIRE BONDS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP

IOG 174 ZONE -2 REQUIREMENTS


SURFACE TEMPRATURE LESS THAN
250C/INSULATED EXHUST
INLET FLAME ARRESTER (FLAME TRAP)
AUTO SHUT DOWN OR FULLY MANNED
INLET SHUT OFF VALVE ACTIVATES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LOB OIL PRESSURE
EXHAUST SPARK ARRESTER/LAGGING
NON ELECTTRICAL STARTING
NON METALIC RADIATOR FAN
ZONE -2 CERTIFIED ANCILLARY EQUIPMENT
AND GUAGES

CHECKLIST FOR MOBILE WHEEL LOADER


Company Name
Equipment
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECKLIST BA NA REMA
N D GOOD RK
START/STOP SWITCH
SEAT/SEAT BELT
BRAKE
HOOD
OPERATORS FLOOR/STEP
BATTERY/TERMINAL
LIFTING/TILING OPERATION
HYDROLIC HOSE
HORN
SIDE MIRROR
LIGHTS
TYRE CONDITION
REVERSE ALARM
ENGINE SIDE COVERS
FIRE EXTINGUISHER
SAFE WORKING LOAD (SWL)

DOCUMENTATION
SURVEY CERTIFICATE
OPERATORS COMPETENCE CERT.
DRIVING LICENCE
SPDC DRIVING PERMIT
MAINTENANCE RECORD
MAINTTENANCE CHART

IOG 174 NON HAZ REQUIREMENTS


NO OIL/FUEL LEAK
FUEL / OIL SPILL CONTAINMENT
LEAK FREE EXHAUST
FIRE RESISTANT FUEL LINES
FUEL TANK ISOLATION/ CUT OFF VALVE
FRAS COOLING FAN BELT
NON METALLIC COOLING FANS
FULLY CHARGED, SECURED BATTERY
PROPER ELECTRICAL CONNECTIONS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP

IOG 174 ZONE -2 REQUIREMENTS


SURFACE TEMPERATURE LESS THAN 250c
INLET FLAME ARRESTER (FLAME TRAP)
INLET AIR SHUT OFF VALVE ACTIVATES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LUB OIL PRESSURE
EXHAUST SPARK ARRESTER NO / WIRE / EN /
USDA
NON ELECTRICAL STARTING
ZONE -2 CERTIFIED ELECTRICAL EQUIPMENT

CHECK LIST FOR MOBILE PIPE LAYER / SIDE BOOM

Company Name
Equipment
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK LIST BA N GOO REMA


N D A D RK
START/STOP SWITCH
OPERATORS CABIN
ENGINE CONDITION
HORN
BACK UP ALARM
ENGINE SIDE COVERS
SAFE WORKING LOAD (SWL)
SLING /WIRE ROPE
BOOM
HOOK
HOIST LIMIT SWITCH
SAFETY LATCH
BRAKES
OPERATORS STEP
GUARD FOR ROTATING PARTS
FIRE EXTINGUISHER

DOCUMENTATION
SURVEY CERTIFICATE
OPERATORS COMPETENCE CERT
DRIVING LICENSE
SPDC DRIVNG PERMIT
MAINTENANCE RECORD
MAINTENANCE CHART

IOG 174 NON HAZ REQUIREMENTS


NO OIL / FUEL LEAKS
FUEL / OIL SPILL CONTAINMENT
LEAK FREE EXHAUST
FIRE RESISTANT FUEL LINES
FUEL TANK ISOLATION / CUT OFF VALVE
FRAS COOLING FAN BELT
NON METALLIC COOING FANS
FULLY CHARGED , SECURED BATTERY
PROPER ELECTRICAL CONNECTIONS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP

IOG 174 ZONE-2 REQUIREMENTS


SURFACE TEMPERATURE LESS THAN 250c
INLET FLAME ARRESTER (FLAME TRAP)
INLET AIR SHUT OFF VALVE ACTIVITIES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LUB OIL PRESSURE
EXHAUST SPARK ARRESTER No/ Wire / EN /
USDA
NON ELECTRICAL STARTING
ZONE -2 CERTIFIED ELECTRICAL EQUIPMENT

CHECKLIST FOR MOBILE OXY-ACETYLENE WELDER

Company Name
Equipment Name
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK ITEMS BA N GOO REMA


N D A D RK
CYLINDERS
KEPT UPRIGHT
CORRECTLY LABELLED
VALVES ARE CLEAN AND UN-DAMAGED

REGULATORS
PRESSURE ADJUSTMENT WORKING
INLET PRESSURE INDICAOR WORKING
MAIN INLET LAVE IS OPERATING
OUTLET PRESSURE INDICATOR WORKING
OUTLET PRESSURE CONTROLLABLE
ALL CONTROLLERS ARE REMAIN IN
INTENDED POSITION
UNDAMAGED AND WELL KEPT
AGE AS PER THE DATE STAMP(caution if
over 5yrs and discard over 10yrs)

BULLNOSE
FACE AND THREAD UNDAMAGED
WELL CONNECTED

FLASHBACK ARRESTER
UNDAMAGED AND NOT OVER 5YEARS OLD
SUITABLE PRESSURE RATING
MAXIMUM REVERSE FLOW WITH 5 PSL
NO FORWARD FLOW UNDER 17 PSL

ANY LEAKS
CYLINDER /REGULATOR JOINT
CYLINDER VALVE
REGULATOR OUTLET
GAUGES NECK AND BODY
REGULATOR BODY
DOCUMENTATION
MAINTENANCE RECORD
MAINTENANCE CHART
COMPETENCE ASSURANCE OF OPERATOR
OUTLET CONNECTION
THREAD UN-DAMAGED
NO DEPOSITE OF CLOGGGING

PRESSURE RELIEF VALVE


FITTED OR NOT

GAUGES
STAYS FIRM LY CONNECTED AND UN-
DAMAGED
CONNECTED TO THE CORRECT PRODUCT
SCALE IS APPROPRIATE
NEEDLE STARTS FROM ZERO
SMOOTH MOVEMENT

TORCH
BOTH INLETS ARE CLEARLY IDENTIFIABLE
BOTH INLETS ARE INDEPENDENTLY
CONTROLLABLE
NO PHYSICAL DAMAGED

HOSES
APPROPRIATE COLOUR CODING
NO CRACKS,DAMAGES OR JOINTS
AGE OF THE HOSE
NO LEAKS FROM CONNECTIONS

CARRIAGE
CYLINDERS SECURELY MOUNTED
CAN REMAIN UP-RIGHT SAFELY
CAN BE MOVED EASILY

CHECKLIST FOR MOBIL BATCHING PLANT

Company Name
Equipment Name
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK ITEM BA N GOO REMA


N D A D RK
START/STOP SWICTH
BELT CONVEYOR
BELT SWITCH OFF
SAFETY SWITCH FOR BELT
RUBBER BELT
COMPRESSOR/PRESSURE GAUGE
PRESSURE SAFETY VALVE
HOSES
SAFETY PINS
DRIVING DRUM
DISCHARGE VALVES
ELECTRICAL CONNECTIONS
CONTROL CABIN
EMERGENCY SHUT OFF LEVER
GUARDS FOR ROTATION PARTS
FIRE EXTINGUISHER
PUMPS

DOCUMENTATION
OPERATORS COMPETENCE CERT.
CALIBRATION CERT.
MAINTENANCE RECORD
MAINTENANCE CHART

IOG 174 NON HAZ REQUIREMENTS


NO OIL/ FUEL LEAKS
LEAK FREE EXHAUST
FUEL/OIL SPILL CONTAINMENT
FIRE RESISTANT FUEL LINES
FUEL TANKS ISOLATION/CUT OFF VALVE
FRAS COOLING FAN BELT
FULLY CHARGED,SECURED BATTERY
PROPER ELECTRICAL CONNECTIONS
ELECTRICAL BONDING / 2x6mm WIRE BONDS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP
IOG 174 ZONE-2 REQUIREMENTS
SURFACE TEMPERATURE LESS THAN
250c/INSULATED EXHAUST
INLET FLAME ARRESTER (FLAME TRAP)
AUTO SHUT DOWN OR FULLY MANNED
INLET AIR SHUT OFF VALVE ACTIVATES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LUB OIL PRESSURE
EXHAUST SPARK ARRESTER - NO / WIRE /
EN /USDA
NON ELECTRICAL STARTING
NON METALLIC RADIATOR FAN
ZONE -2 CERTIFIED ANCILLARY EQUIPMENT
AND GAUGES

CHECKLIST FOR MOBILE CHAINSAW


Company Name
Equipment Name
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK ITEM BA N GOO REMA


N D A D RK
START/STOP SWITCH (CLEARLY MARKED)
SPEED CONTROL SWITCH (THROTLE)
GAUGES
COUPLINGS
PROTECTIVE GUARDS
FRONT HANDLE CHAIN GUARD
REAR HANDLE CHAIN GUARD
GENERAL APPEARANCE
SPARK PLUG /CABLES
NOISE LEVEL
HANDLE FITTING (NON-VIBRATING)
TOOL KITS
EXHAUST CONDITION
MANUFACTURERS LABEL
FUEL TYPE (PETROL/DIESEL)
FIRE EXTINGUISHER
FIRST AID BOX
FACE VISOR

DOCUMENTATION
MAINTENANCE RECORD
MAINTENANCE CHART
SURVEY CERTIFICATE
SPDC COMPETENCE ASSURANCE OF
OPERATOR

IOG 174 NON HAZ REQUIREMENTS


NO OIL/FUEL LEAKS
LEAK FREE EXHAUST
FIRE RESISTANT FUEL LINES
FUEL TANK ISOLATION / CUT OFF VALVE
FRAS COOLING FAN BELT
EMERGENCY STOP
IOG 174 ZONE-2 REQUIREMENTS
SURFACE TEMPERATURE LESS THAN 250C
INLET FLAME TRAP
INLET AIR SHUT OFF VALVE ACTIVATES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLENT TEMP
LOW LUB OIL PRESSURE
EXHAUST SPARK ARRESTER NO / WIRE / US /
EN
NON ELECTRICAL STARTING

CHECK LIST FOR MOBILE INSPECTION OF SAND BLASTING


Company Name
Equipment Name
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK ITEM BA N GOO REMA


N D A D RK
START/STOP SWITCH
MOUNTAIN BASE
PROTECTIVE GUARD
TORCH / NOZZLE
DEAD MAN SWITCH
TEMPERATURE RECORDER
DRAIN TAP
SAND BLAST HOSES
HOSE LOCKING DEVICES
HOSE CONNECTORS
EARTH WIRE
SAFE WORKING PRESSURE
PRESSURE GAUGE
TRIGGER SAFETY CATCH
RELIEF VALVE
WHIP CHECK
AIR VALVE
NO AIR ,FUEL & OIL LEAKAGE
SAND BLASTING GUN
SAND BLASTER NOZZLE
SAND BLASTER FILTER
MEDIA VALVE (GRIFTS & VALVES )
MOISTURE SEPARATOR
SAND BLASTING HELMET, & HOOD
SAND BLASTING SUITS & CAPES
APPEARANCE ( HOUSE KEEPING )
OTHER SPECIFY

DOCUMENTATION
MAINTENANCE RECORD/CHART
OPERATORS COMPETENCE CERT
SURVEY CERTIFICATE
CHECK LIST FOR MOBILE INSPECTION OF PILLING

Company Name
Equipment Name
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK ITEM BA N GOO REMA


N D A D RK
START/STOP SWITCH
SPEED CONTROL UNIT
OIL LEAKAGE
EMERGENCY STOP
COUPLINGS
HYDRAULIC HOSES
SLINGS/CABLES
CHAIN BLOCK
PROTECTIVE GUARDS
GENERAL STRUCTURE (APPEARANCE)
FIRE EXTINGUISHER
OPERATORS CABIN
ENGINE CONDITION
HORN
OTHERS-SPECIFY

IOG 174 NON HAZ REQUIREMENTS


NO OIL/ FUEL LEAKS
FUEL / OIL SPILL CONTAINMENT
LEAK FREE EXHAUST
FIRE RESISTANT FUEL LINES
FUEL TANK ISOLATION / CUT OFF VALVE
FRAS COOLING FAN BELT
NON METALLIC COOLING FANS
FULLY CHARGED, SECURED BATTERY
PROPER ELECTRICAL CONNECTIONS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP

IOG 174 ZONE -2 REQUIREMENT


SURFACE TEMPERATURE LESSS THAN 250c
INLET FLAME ARRESTER (FLAME TRAP)
INLET AIR SHUT OFF VALVE ACTIVITES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LUB OIL PRESSURE
EXHAUST SPARK ARRESTER - NO /WIRE / EN /
USDA
NON ELECTRICAL STARTING
ZONE 2 CERTIFIED ELECTRICAL EQUIPMENT

DOCUMENTATION
MAINTENANCE RECORD
MAINTENANCE CHART
SURVEY CERTIFICATE
CRANE PRE-MOB STATUS
OPERATORS COMPETENCE CERT

CHECKLIST FOR MOBILE BULLDOZER

Company Name
Equipment Name
Make
Model
Rated Capacity
Serial Number
Inspection Date
Registration Number
Year Of Manufacture

S/ CHECK ITEM BA N GOO REMA


N D A D RK
START/STOP
ENGINE SIDE COVER
GUARD FOR ROTATING PARTS
RADIATOR
TRACKS
SEAT/SAET BELT
HOOD
HYDRAULIC LINE
BRAKE
HORN
BATTERY/ TERMINALS
HYDRAULIC RAMS
REVERSE ALARM
FUEL TANK COVER
OTHER SPECIFY

IOG 174 NON HAZ REQUIREMENT


NO OIL / FUEL LEAKS
FUEL / OIL SPILLCONTAINMENT
LEAK FREE EXHAUST
FIRE RESISTANT FUEL LINES
FUEL TANK ISOLATION / CUT OFF VALVE
FRAS COOLING FAN BELT
NON METALLIC COOLING FANS
FULLY CHARGED, SECURED BATTERY
PROPER ELECTRICAL CONNECTIONS
AIR INLET SHUTDOWN VALVE
EMERGENCY STOP

IOG 174 ZONE-2 REQUIREMENTS


SURFACE TEMPERATURE LESS THAN 250c
INLET FLAME ARRESTER (FLAME TRAP)
INLET AIR SHUT OFF VALVE ACTIVATES ON
HIGH EX TEMP
ENGINE SPEED
HIGH COOLANT TEMP
LOW LUB OIL PRESSURE
EXHAUST SPARK ARRESTER -NO / WIRE / EN /
USDA
NON ELECTRICAL STARTING
ZONE -2 CERTIFIED ELECTRICAL EQUIPMENT

DOCUMENTATION
OPERATORS COMPETENCE CERT.
DRIVING LICENSE
SPDC DRIVING PERMIT
MAINTENANCE RECORD
MAINTENANCE CHART

Das könnte Ihnen auch gefallen