Size and Weight: 5.000'' 19.50 ppf 0.

362'' wall IEU


Grade: G-105
Drill Pipe Performance Sheet Range: 2
Asset Number: WS41-30 Tool Joint: 6.625'' x 3.250'' NC50

Pipe Body: Tubular Assembly:


Nominal Ultra Class Premium
100% RBW 95% RBW 90% RBW 80% RBW Adjusted Weight (lbs/ft): 24.11 Fluid Displacement (gal/ft): 0.37
Approximate Length (ft): 31.5 Fluid Displacement (bblsl/ft): 0.0088
OD (in): 5.000 4.964 4.928 4.855
Wall Thickness (in): 0.362 0.344 0.326 0.290 Box TJ Length (in): 12 Fluid Capacity w/IPC (gal/ft): 0.70
Nominal ID (in): 4.276 4.276 4.276 4.276 Pin TJ Length (in): 9 Fluid Capacity w/IPC (bbls/ft): 0.0167

Tensile Strength (lbs): 553,832 524,087 494,558 436,149 Upset Type: IEU Fluid Capacity w/o IPC (gal/ft): 0.71
Torsional Strength (ft-lbs): 57,633 54,478 51,354 45,199 Max Upset OD (in): 5.125 Fluid Capacity w/o IPC (bbls/ft): 0.0169
Drift Size (in): 3.125
Burst Capacity (psi): 13,304 14,444 13,684 12,163
Collapse Capacity (psi): 12,999 11,963 10,913 8,765

18
0

Note: These are OEM values that may vary with actual values due to mill tolerances, IPC tolerances, OEM rounding, and other
Notes: Body properties are calculated based on uniform OD and wall thickness. factors. Pipe is purchased at a guaranteed 95% RBW. IPC is applied to a nominal thickness of 0.009''. Pipe will have an ID of
Burst capacity for Nominal (100% RBW) based on 87.5% RBW per API. 4.218'', which is smaller than pipe purchased at 87.5%.

Connection: NC50 Elevator Shoulder:


TJ OD (in): 6.625
TJ ID (in): 3.250
MYS (ksi): 120 Maximum MUT (ft-lbs): 30,700 Smooth Edge Height (in): 3/32
Tension at Shoulder Separation @ Max MUT (lbs): Tensile Limited Smooth Edge OD (in): 6.812
Tension at Connection Yield @ Max MUT (lbs): 1,117,600 SE Elevator Shoulder Capacity (lbs): 1,658,000

Minimum MUT (ft-lbs): 25,600 Nominal TJ OD (in): 6.625


Tension at Shoulder Separation @ Min MUT (lbs): 1,132,000 Nominal TJ OD Elevator Shoulder Capacity (lbs): 1,440,200
Tension at Connection Yield @ Min MUT (lbs): 1,250,000
Assumed Elevator Bore (in): 5.250

N/A Tool Joint Torsional Strength (ft-lbs): 51,200


N/A Tool Joint Tensile Strength (lbs): 1,250,000
Note: Elevator capacity based on assumed elevator bore, no wear factor, and contact stress of 110, 100 psi. An increased
Note: MUT values are based on a friction factor of 1.0. There is no published pressure rating for this connection. elevator shoulder OD increases elevator capacity without affecting make-up torque.

The technical information containted herein, including the product performance sheet and other attached documents, has been extracted from information available from the manufacturer and is for reference only and not a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical
information. Workstrings International cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various
inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operation limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices,
and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

www.workstringsinternational.com 30-Nov-15
Download the Workstrings International Pipe Specification App on the App Store or Google Play
Operational Limits of Drill Pipe
Connection NC50 Tool Joint OD (in) 6.625 Tool Joint ID (in) 3.250 Tool Joint Specified Minimum 120,000
Yield Strength (psi)

Pipe Body 80 % Inspection Class Pipe Body OD (in) 5 Wall Thickness (in) 0.362 Pipe Body Grade G-105

(ft-lbs) (ft-lbs)

(ft-lbs) (lbs) (lbs) (lbs) (ft-lbs) (lbs) (lbs) (lbs)

0 436,100 436,100 1,117,600 0 436,100 436,100 1,132,000

435,900 1,117,600 1,300 436,000 436,000 1,132,000


1,600 435,900
435,100 1,117,600 2,700 435,400 435,400 1,132,000
3,200 435,100
4,800 433,700 433,700 1,117,600 4,000 434,400 434,400 1,132,000

6,400 431,800 431,800 1,117,600 5,300 433,100 433,100 1,132,000

8,000 429,300 429,300 1,117,600 6,600 431,500 431,500 1,132,000

9,600 426,200 426,200 1,117,600 8,000 429,300 429,300 1,132,000

11,200 422,500 422,500 1,117,600 9,300 426,800 426,800 1,132,000

12,800 418,300 418,300 1,117,600 10,600 424,000 424,000 1,132,000

14,400 413,400 413,400 1,117,600 11,900 420,800 420,800 1,132,000

407,900 1,117,600 13,300 416,800 416,800 1,132,000


16,000 407,900
401,700 1,117,600 14,600 412,800 412,800 1,132,000
17,600 401,700
19,200 394,800 394,800 1,117,600 15,900 408,300 408,300 1,132,000

20,800 387,200 387,200 1,117,600 17,200 403,300 403,300 1,132,000

22,400 378,800 378,800 1,117,600 18,600 397,500 397,500 1,132,000

23,900 370,200 370,200 1,117,600 19,900 391,600 391,600 1,132,000

25,500 360,100 360,100 1,117,600 21,200 385,200 385,200 1,132,000

27,100 349,100 349,100 1,117,600 22,500 378,300 378,300 1,132,000

28,700 336,900 336,900 1,117,600 23,900 370,200 370,200 1,132,000

323,300 1,117,600 25,200 362,100 362,100 1,132,000


30,300 323,300

Connection
Make-up Torque Range

(ft-lbs) (lbs)

25,600 1,132,000
26,200 1,158,500
26,700 1,180,600
27,300 1,207,200
27,900 1,233,700
28,400 1,242,800
29,000 1,210,200
29,600 1,177,500
30,100 1,150,300
30,700 1,117,600
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.

Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

06-17-2015

Das könnte Ihnen auch gefallen