HD 044 HD 064
Flangeable
Operating pressure up to 500 bar
Nominal flow rate up to 105 l/min
40.30-4e
Description
Characteristics
Hydraulic fluids
Mineral oil and biodegradable fluids
Operating pressure p [bar]
Temperature range
-30 C ... +100 C (temporary -40 C ... +120 C)
D1 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at = 35 mm2/s (0 = casing empty) at nominal flow
1,5 12
HD044 3 1+3+5
10
2 6
4
p [bar]
p [bar]
1,0 8
5 4 2
1 6
6
0,5 4
0 2
Q [l/min] [mm2/s]
D2 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at = 35 mm2/s (0 = casing empty) at nominal flow
1,5 12
HD064 1+3 5 6
3 10
p [bar]
4 2
p [bar]
1,0 8
1 4 6 6
2 5
0,5 4
0 2
Q [l/min] [mm2/s]
x ss nt
g r. D b y -pa me
o . i a i t y o f e l e
e e n ed c re lte
r r
rat p se urve ss se capa A/B ssu t fi icato
o w r o / c e g n p r e e n ind
l fl re d m D finen oldin io ng em . rks
No
. na u
mi ress iagra ilter ect cki mbo
l
lac rt No t ing
t t-h nn p igh gg ma
Par N o P d F D i r C o C ra Sy R e Pa We Clo Re
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11 12
HD 044-183 27 D1/1 5EX2 5,2 15 - 7 V3.0510-13 3,4 1
optional 2
HD 064-183 50 D2/1 5EX2 8,7 15 - 7 V3.0520-131 4,6 optional 2
Optical or electrical indicators are available to monitor the clogging condition of the element. If the indicator should be already mounted onto the filter
head use the abbreviation M behind the part number of the indicator. The printed order acknowledgements show both items separately.
Order example: The filter HD 064-156 has to be supplied with optical clogging indicator - response pressure 5,0 bar
1
Element differential pressure stable up to 160 bar
2
Clogging indicator is obligatory
Dimensions
Minimum distance
from ferromagnetic
parts: 7 mm
Measurements
Type A/B C D E F G H I K L M N O P Q R S T U V
electr. / opt.
HD 044 15 23,5 145 26 49 83 66 70 36 58 12,5 118,5 48 90 17 13 16 106 / 79 45 2
HD 064 15 23,5 241 26 49 83 66 70 36 58 12,5 118,5 48 90 17 13 16 106 / 79 45 2
Symbols
1 2 3 4 5 6 7
Spare Parts
3
The functions of the complete filters as well as the outstanding features
of the filter elements assured by ARGO-HYTOS can only be guaranteed if
original ARGO-HYTOS spare parts are used.
Quality Assurance
Quality management according to DIN EN ISO 9001 ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and
To ensure constant quality in production and operation, ARGO-HYTOS dirt-holding capacity)
filter elements undergo strict controls and tests according to the following ISO 23181 Determination of resistance to flow fatigue using high
ISO standards: viscosity fluid
ISO 2941 Verification of collapse/burst pressure rating Before release into the series production the filter casing is tested for fati-
ISO 2942 Verification of fabrication integrity (Bubble Point Test) gue strength in our pressure pulse test rig. Various quality controls during
ISO 2943 Verification of material compatibility with fluids the production process guarantee the leakfree function and solidity of our
filters.
Our engineers will be glad to advise you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.