Sie sind auf Seite 1von 4

EL: extremely low MH: medium high

VL: very low VH: very high


ML: medium low EH: extremely high
N: normal

T EL VL ML N MH VH EH
H
EL EL EL VL VL ML ML N

VL EL VL VL ML ML N MH

ML VL VL ML ML N MH MH

N VL ML ML N MH MH VH

MH ML ML N MH MH VH VH

VH ML N MH MH VH VH EH

EH N MH MH VH VH EH EH

Average Weighted:
n

f Center
P= i=1 n

f
i=1
1) T= 35 oC
H= 100%
number of rules triggered (n)= 1
If temperature is normal and humidity is extremely high
then power is very high.
N (T) = 1 AND EH (H) = 1 VH (P) = 1
12.5
P= =2.5 kw
1

2) T=45
H= 75%
number of rules triggered (n)= 2
If temperature is medium high and humidity is medium
high then power is medium high.
MH (T) = 1 AND MH (H) = 0.78571 MH (P) = 0.78571

If temperature is medium high and humidity is very high


then power is very high.
MH (T) = 1 AND VH (H) = 0.2142 VH (P) = 0.2142
0.78572+0.21422.5
P= =2.107 kw
0.7857+0.2142

3) T= 50
H= 50%
number of rules triggered (n)= 4
If temperature is medium high and humidity is medium
low then power is normal.
MH (T) = 0.5 AND ML (H) = 0.5714 N (P) = 0.5

If temperature is very high and humidity is medium low


then power is medium high
VH (T) = 0.5 AND ML (H) = 0.5714 MH (P) = 0.5

If temperature is medium high and humidity is normal


then power is medium high.
MH (T) = 0.5 AND N (H) = 0.4285 MH (P) = 0.4285

If temperature is very high and humidity is normal then


power is medium high.
VH (T) = 0.5 AND N (H) = 0.5 MH (P) = 0.4285
0.52+ 0.51.5+ 0.428522
P= =1.8653 kw
0.52+0.42852

Mean of two max:


1C + 2C
P=
2

1) P=2.5 kw
0.78572+0.21422.5
2) P= 2
=1.0534 kw

0.52+ 0.51.5
3)
P= =0.875 kw
1

2.5
2.10
1.72

Das könnte Ihnen auch gefallen