Sie sind auf Seite 1von 1

ACI-318 08

f'c = 28 Mpa fy = 413 Mpa


TENSION STEEL COMPRESSION HOOKED

Diameter
Bar Size
Straight Development SPLICES STEEL DEVELOPMENT

(mm)
MIN

Bar
C/C SP. Other Bars Top Bars CLASS A CLASS B ALL BARS
DEVELOP SPLICE
(ld) (ld) Other Bars Top Bars Other Bars Top Bars (ldh)
#3 75mm 360 mm 470 mm 360 mm 470 mm 470 mm 600 mm 180 mm 310 mm 180 mm 9.5
#4 75mm 480 mm 620 mm 480 mm 620 mm 620 mm 800 mm 240 mm 380 mm 240 mm 12.7
#5 100mm 600 mm 770 mm 600 mm 770 mm 770 mm 1000 mm 300 mm 470 mm 300 mm 15.9
#6 100mm 710 mm 930 mm 710 mm 930 mm 930 mm 1200 mm 360 mm 560 mm 360 mm 19.1
#7 150mm 1030 mm 1330 mm 1030 mm 1330 mm 1330 mm 1730 mm 420 mm 660 mm 420 mm 22.2
#8 150mm 1170 mm 1520 mm 1170 mm 1520 mm 1520 mm 1980 mm 480 mm 750 mm 480 mm 25.4
#9 200mm 1320 mm 1710 mm 1320 mm 1710 mm 1710 mm 2220 mm 540 mm 840 mm 540 mm 28.6
#10 250mm 1460 mm 1900 mm 1460 mm 1900 mm 1900 mm 2470 mm 600 mm 940 mm 600 mm 31.8
#11 250mm 1610 mm 2090 mm 1610 mm 2090 mm 2090 mm 2710 mm 660 mm 1030 mm 660 mm 34.9

Sec 12.2 Development of deformed bars and deformed wires in tension


No.6 and smaller bars and No.7 and larger
deformed wires bars
Clear spacing of bars or wires being developed or spliced
not less than db, clear cover not less than db, and stirrups
or ties throughout ld not less than the code minimum. fy*a*b*db fy*a*b*db
or 2.1**f'c 1.7**f'c
Clear spacing of bars or wires being developed or spliced not
less than 2db and clear cover not less than db.
other cases fy*a*b*l*db 3fy*a*b*l*db
1.4f'c 1.1f'c
Using clause of Sec 12.2.1, ld shall not be less than 300mm.

For top bars:


a= 1.3 (Sec 12.2.4(a))
1.5 (for epoxy-coated bars or wires with cover <3db, or clear spacing <6db)
1.2 (for all other epoxy-coated bars or wires)
b= 1.0 (for uncoated reinforcement)
but, a*b 1.7
= 1.0 (for normal weight concrete)

For other bars:


a= 1.0 (Sec 12.2.4(a))
1.5 (for epoxy-coated bars or wires with cover <3db, or clear spacing <6db)
1.2 (for all other epoxy-coated bars or wires)
b= 1.0 (for uncoated reinforcement)
but, a*b 1.7
= 1.0 (for normal weight concrete)

Sec 12.15 Splices of deformed bars and deformed wire in tension


Splice = 1.0 * ld (for Class A splice)
= 1.3 * ld (for Class B splice)
= 300 mm (minimum splice length)

Sec 12.3 Development of deformed bars and deformed wires in compression


ldc = 0.24*fy*db
*f'c

Sec 12.16 Splices of deformed bars in compression


Splice = 0.071*fy*db (fy 420 MPa)
= (0.13*fy-24)*db (fy > 420 MPa)
= 300 mm (minimum splice length)

Sec 12.5 Development Length of Standard Hooks, ldh


ldh = 0.24*e*fy*db (shall not be less than 8db and 150mm)
*f'c

e = 1.0 (for uncoated Grade60 Bars)


= 1.0 (for normal weight concrete)
f'c = 28 MPa
fy = 413 MPa

Sec 12.5.3(a): 1.0 (Applicable modification factor)