Sie sind auf Seite 1von 3

(1) Keyboard

Numerical und function keys for


(4) Cuvette tower
For load of 45 cuvettes: enough
(6) Liquid handling
x-y-z high speed robotic system
(7) Pump/syringe
Maximum volume: 2500 l Innovation in
easy controlling of the instrument,
as well quick setup of all individual
for 270 tests, continuous loadable with special Cap Piercing probe,
Level sense.
Minimum volume: 3 L
Long life syringe
Coagulation
tests. Easy to replace and maintain
(5) Printer (back side)
Thermal printer for quick printout
(2) Grafic display of results, system analysis, test (8) Rinse container (back side)
128 x 128 dot matrix setups etc. Containing 1,25 Liter high quality
Blue backlight rinse solution for flushing the
probe after each pipette circle. Special features of the Coatron A6:
(1 tank ~ 1500 PT)
(3) Cuvette waste drawer Measurement
Removable waste drawer for fast Clotting, chromogenic, immunological
removing of used cuvettes (9) Reagent block Quarter test volume (75L)
17 positions heated high speed testing
12 positions cooled Biphasic waveform analysis
Profile testing in batch or random access
Single or double determination
(10) System block Automatic reflex testing
5 positions heated at 37C
for Buffers, Clean solution and Sample
Flush position for the probe, inside 3 x 15 primary tubes
and outside.Separate STAT Positive sample identification (ID and rack position ) with barcode
4 Cap Piercing for BD Vaccutainer or Sarstedt Monovette.
position for immediate Emergency
5 Micro tubes like Eppendorf 2mL for pediatric samples
Emergency STAT position
(11) Sample racks Sample continous loading in random access mode
8
3 racks with 15 positions each,
suitable for most common primary System
tubes. Every position have 6 optic channels at 405nm with auto light sensing and extraneous
individual bar code for positive light elimination to reduce interferences such like bilirubin or
7 sunlight.
sample identification
High-precision XYZ pipetting system with liquid level sensor
Long living and flexible Cap Piercing needle
(12) Barcode Integrated laser barcode reader for samples and reagent
6 Laser Barcode Scanner Bi-directional Interface for PC-Link to LIS.
for quick and accurate Optional trolley to enlarge the waste management
identification of all Integrated graphical thermal printer
Common Barcodes 34 heated and cooled positions for reagents, controls, buffers
9
Integrated drawers for consumables
System configuration as OPEN or CLOSED
(13) Liquid waste drawer
12 Contain container for collection Quality Control
liquid waste Onboard positions for up to 4 control plasma.
Volume: 1,25 Liter max. Auto QC flagging for errorneous results
One click report with Levey-Jennings graph and Westgard analysis
LOT. number ( control + reagent) specific QC analysis is possible
Optionally: Trolley
For mobile usage and enlarged Software
11 waste management (big box for An intuitive TECO familiar graphical user interface.
used cuvettes and large container Multi language dialogue (English, German, Spanish, Italian a.o.)
for liquid waste) Free programmable test protocols to change or adapt new tests
Calculation of activity %, INR, Ratio, g/L, mg/dL and more.
13 Calibration curve can be identified with up to 6 points per test.
Lift-up plate for sample
1 preparation (more work area) Simple firmware update
10
20 Moveable plate for easy Special Functions
0 replacement of box and container Automatic plasma dilutions up to 1:100
2 Automatic test calibration routines
Additional drawer for accessories Automatic test skip, if reagent run out.
and spare parts Full database for patient history.
3 Patient monitoring for long time periods
Reaction curve monitoring

Economic
Quarter test volume to 75% cost savings.
Reagent dead volume is below 200 L
Very economic consumption of rinse and cleaning solution.
All critical system parameters are monitored and make the
Instrument nearly free of service.
Innovation in

Coatron A6 Coagulation

Fully automated Hemostasis Analyzer

Made in Germany
REF: 80 920 00

Clotting, chromogenic,
immunological

DTI & DXI (e.g. Hirudin,


Dabigatran, Fondaparinux)
and Thrombin generation
measurement

Fully automated 6 channel


Coatron A6 random access analyser

High throughput
Tests on board: Technical specification Optional available
PT Trolley (for enlarged waste
Up to 75% lower running costs
APTT Dimension management)
( quarter volume, low service)
TT 85 x 60 x 70 cm Complete Cover protection
Fibrinogen Clauss and derived TECAM PROLIS required for bi
45 patient and 33 reagent
Factor II Weight directional ASTM interface to
positions
Factor V 40 kg LIS
Factor VII
Patient continuous loading
Factor VIII Power input
Factor IX 90-240 Vac / 50-60 Hz Delivery package
Autoskip and reflex testing
Factor X 1 Coatron A6
Factor XI Ambient conditions 1 Power cord
Database for up to 1 Mio
Factor XII 18C 30C 100 Cuvettes, 6 pos/ea
results (including reaction
Protein C 20% - 80% r.H. 10 Reagent container 22,5
curve)
Protein S no direct sunlight 10 Reagent tubes 13
LA Screen (DRVVT) 10 Plasma tubes 16
One click result reports
LA Confirm (DRVVT) 4 Magnetic stirrer
Activated Protein C resistance 1 Rinse Solution, 1,25L
One click quality control
Heparin 1 Clean solution, 50mL
reports with Levey-Jennings
Antithrombin 1 Thermal paper roll
graph and Westgard analysis
D-Dimer 1 Waste container
1 Reagent adapter 22,5
Integrated laser barcode
In preparation: 2 Plasma adapter 16
reader for samples and
PEGX chrom for DXaI 1 Operation manual
reagents
ECAH chrom for DTI 1 CE Conformity declaration
THRO (Thrombin generation) 1 Service CD
Multi languages
1 Download cable
Calculated units 1 Screw driver, small
Cap piercing
Activity %, Ratio, Polish ratio, INR 1 Flat wrench, size 8
(ISI system or INR calibration
Reaction curve monitoring
curve), g/L, mg/dL, ng/L, ng/mL,
g/L, IU/mL
Bi-directional ASTM interface
(RS232 or network)

System monitoring for reagent,


consumables and service.

Very compact but robust


TECO Medical Instruments,
construction with small
Production + Trading GmbH
footprint.
Dieselstr. 1
D-84088 Neufahrn NB.
System works with any
Germany
reagent, but can be configured
Fon: +49-8773-70780 0
as closed
Fax: +49-8773-70780 29
Email: info@teco-gmbh.com
Web: www.teco-gmbh.com
TECAM PROLIS Innovation in
For Microsoft WindowsTM XP/Vista Coagulation
Software For TECO Coatron A4/A6 Analyzer

New features for Coatron A4/A6


Intuitive and easy one click operation
Database up to 1 Mio results
Worklist management
Bidirectional ASTM interface to LIMS
Multi-lingual (Chinese+ Russian included)
Recommended system requirements: Flexible multi filter
Reaction curve display
Microsoft XP, CPU 1.5 GHZ, 1GB RAM, Graphic Combine every data field:
Powerful filter and patient report engine
1280x1024 PID=1234+ Date=today + Test=FIB + Result<
QC with Levey-Jennings and Westgard rules
200mg/gL + Reagent LOT = 1234 + etc)
Support instruments
Coatron A4/A6 and OEMs Filter Presets:
TECAM PROLIS is a perfect and user friendly tool to
Today; last 7, 15, 30, 180, 360 days; morning,
combine laboratory data management, quality control
Instrument Interface afternoon; only QC etc.
and research purpose in one. The Worklist management
allows defining orders much faster and flexible then on Serial RS232, 115000 Baud, 8,1,N
Bidirectional for results, including reaction curve and Statistical analyse for QC or patients
the instrument itself. Powerful filter functions will help to
orders. Filter any data (e.g. Patient XYZ, only PT, last
create any report. Levey-Jennings graph and West gard
30days), and visualize them with Levey Jenning
analysis are used for quality control monitoring. An
ASTM Interface diagram with one click. Analyse data with
ASTM interface is included, which allows to link over LAN
Protocol: ASTM E1381-94; E1394-97 Westgard Multirules. Define QC or Patient ranges.
network with the laboratory information system.
Communication: TCP/IP (network, LAN)
Bidirectional for results, including reaction curve and Research
orders. Curve analysis, Tecmoni transmission, Export data,
Receive results from instrument including the reaction
TECAM: grids, charts, curves to PDF, XLS, TXT or HTML file
RESULT - DATABASE curve which will help to validate before saving them into
- WORKLIST the database. Intuitive handling
Instrument
(RS232)
- REPORTS ASTM
One click principle for data collection, filtering, Tecmoni transmission
ORDER - STATISTICS RESULT
LIMS reporting or QC This tools allows to visualize all optic channels in
- RESEARCH
- QC
ORDER
real-time. It is perfect for enhanced curve analysis
Multi lingual and used in many research laboratories. With
English, Spanish, Italian, Portuguese, Russian, Greek, Tecmoni the reaction curves can also sent back to
Chinese, further languages possible. instrument. Especially for developing new test
application and instrument firmware, this will save
Database a lot of reagent and time.
Manage over 1Mio results and patient information in
one database. Security
Operator can login as Administrator or user in
Data fields for: order to control and manage the database with
Date, patient (Id, name, sex, birth, bed, station), different access rights
test, results (s, %, INR), reaction curve, Flags, error,
comment, reagent-LOT, patient-memo, analyser SN., Online update
Create or receive orders from LIMS and send them to ranges (QC + normal)
instrument.
Database functions:
Create, Switch, Backup, Compress, Import, Export,
Replace or fill data,

Complete Traceability by one click


Review for Date, PID, Test, and QC by one click

Reporting
Make reports by one click. Use multi-filter or presets
to generate specific reports (e.g. show results of
specific patient of all PT within the last 30 days)

Worklist management
Create, load, save, repeat, receive and send. Positive
patient identification by barcode validation. USB
barcode scanner supported. Up to 3 different profiles.
Max 8 tests per profile. Preset for up to 6 different QC
samples.
Create reports with a click. Powerful filter functions will Results can be displayed in a Levey-Jennings graph and
help to select just specific results. (e.g. day report, analysed with Westgard rules. This tool can be used for
report the last 30 days of patient xyz, report all D-Dimer QC but also for powerful patient monitoring (e.g. last 30
results of last year which are positive) PT of patient)

Das könnte Ihnen auch gefallen