5-66 API STANDARD 650

Table 5.13aDimensions for Roof Manholes (SI)


Dimensions in millimeters

Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 Column 8 Column 9


Diameter of
Outside
Diameter Diameter Hole in Roof
Diameter Diameter of
Size of of Cover of Bolt Number Plate or
of Neck Reinforcing
Manhole Plate Circle of Bolts Diameter of Gasket Reinforcing
IDa Plate
DC DB Plate
Inside Outside DR
DP

500 500 660 597 16 500 660 524 1050

600 600 762 699 20 600 762 625 1150


--```,,,``````,`,,,`,,,,,```,`,,-`-`,,`,,`,`,,`---

a Pipe may be used for neck, providing the minimum nominal wall thickness is 6 mm (ID and Dp shall be adjusted accordingly.)

NOTE See Figure 5.18.

Table 5.13bDimensions for Roof Manholes (USC)


Dimensions in inches

Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 Column 8 Column 9


Diameter of
Outside
Diameter Diameter Hole in Roof
Diameter Diameter of
Size of of Cover of Bolt Number Plate or
of Neck Reinforcing
Manhole Plate Circle of Bolts Diameter of Gasket Reinforcing
IDa Plate
DC DB Plate
Inside Outside DR
DP

20 20 26 231/2 16 20 26 205/8 42

24 24 30 271/2 20 24 30 245/8 46
a Pipe may be used for neck, providing the minimum nominal wall thickness is 1/4 in. (ID and Dp shall be adjusted accordingly.)

NOTE See Figure 5.18.

b) For anchored tanks, except those designed to F.1.3, the pressure relief devices shall be adequate to prevent
internal pressure from exceeding the tank design pressure as determined in F.4.1 (subject to the limitations in
F.4.3, as applicable).

c) For tanks designed to F.1.3 (anchored tanks), the pressure relief devices shall be adequate to prevent internal
pressure from exceeding the design pressure specified by the Purchaser.

5.8.5.4 The filling and emptying rates are specified on the Data Sheet, Line 7. See the Data Sheet, Table 3 for
venting devices, which shall be specified by the Purchaser and verified by the Manufacturer.

5.8.5.5 All free vents shall be provided with corrosion-resistant coarse-mesh bird screens of a maximum opening
size of (19 mm [3/4 in.] nominal opening). It is recommended that in areas where snow drifting or icing may be an
issue, special attention to vent details (such as profile, diameter, capacity, arrangement, or increased screen size)
should be made. In these situations the Purchaser shall specify modified venting requirements based on anticipated
needs for a specific environment. The smallest dimension of the opening in any mesh used for bird screen is the
governing size for the opening.

5.8.5.6 Flanged roof nozzles shall conform to Figure 5.19 and Table 5.14a and Table 5.14b. Slip-on flanges and
weld neck flanges shall conform to the requirements of ASME B16.5 for Class 150 plate-ring flanges shall conform to

Copyright American Petroleum Institute


Provided by IHS under license with API Licensee=Techint S.A./5938621100, User=Vanoli, Ariel
No reproduction or networking permitted without license from IHS Not for Resale, 05/03/2013 13:46:43 MDT
WELDED TANKS FOR OIL STORAGE 5-67

16-mm (5/8-in.) diameter bolts in 20-mm (3/4 in.)


diameter holes (see Table 5-13a and Table 5-13b
for number of bolts; bolt holes shall straddle
centerlines)

A 150 mm (6 in.) A

6 mm (1/4 in.) cover plate


150 mm (6 in.)

6 mm (1/4 in.)
cover plate 6 mm

--```,,,``````,`,,,`,,,,,```,`,,-`-`,,`,,`,`,,`---
(1/4 in.)
DC
DB 6 mm (1/4 in.)
16 mm (5/8 in.)
diameter rod
5 mm (3/16 in.)
Alternative Flange Detail
75 mm (3 in.) 150 mm
(6 in.)
1.5 mm (1/16 in.) 6 mm (1/4 in.)
thick gasket

Reinforcing plate Axis always or 150 mm (6 in.) min


vertical
(1
6 mm /4 in.) 6 mm (1/4 in.) 5 mm (3/16 in.)
6 mm (1/4 in.)

ID
Roof plate
DP
DR

Section A-ARoof Manhole With Reinforcing Plate

Alternative Neck-to-
Roof-Plate Joint

6 mm (1/4 in.)
6 mm (1/4 in.)

Roof plate
ID
DP

Base For Roof Manhole Without Reinforcing Plate

Figure 5.16Roof Manholes (see Table 5.13a and Table 5.13b)

Copyright American Petroleum Institute


Provided by IHS under license with API Licensee=Techint S.A./5938621100, User=Vanoli, Ariel
No reproduction or networking permitted without license from IHS Not for Resale, 05/03/2013 13:46:43 MDT