Sie sind auf Seite 1von 12

Organic Jeans Ltd.

Immediate Prop Calculation

1
Organic Jeans Ltd.

1 Immediate prop calculation


Minimum live loads on floor are 40 psf.

Different column in different position as shown in Fig:1 bellow and their loads on different floor is calculated
without any factor & relevant existing column capacity and required number of prop is as follows

Fig1: Load test column layout plan

2
Organic Jeans Ltd.
Load carrying capacity of existing column

Load carrying capacity of column in different floor are calculated as follows

Fig2: Load carrying capacity calculation of existing column at ground floor level

Table: 1 Load carrying capacity (KN) of existing column at different level is as follows

Level Ground floor 1st floor 2nd floor 3rd floor


Existing Column 764.9 1238 1265 1046
load carrying
capacity (KN)

3
Organic Jeans Ltd.
Table:2 Load on different column and relevant load carrying capacity & required prop (if any) calculation are as follows

3rd Floor
Load Carry
Requires Required out by
Item Column Capacity of Provide
Notation's Floor Load FoS Propping Number Of Existing FoS Remarks
Code Capacity Propping Props
Load Props Column and
Props
(DD+LL)-KN KN KN KN Nos Nos KN
iv = (i x 1.25
i ii iii = (ii/i) v vi = (iv/v) vii viii ix = (viii/i)
- ii)
A1,
Props not
CL1 A7,F1,F2,F3,F5, 20.8 1046 50.29
required
F6,F7
A2,A3,A4,A5,,A6
Props not
CL2 ,B1,B7,C1,C7,D1 50 1046 20.92
required
,D7, E1,E7,F4
E2,E3,E5,E6,D6, Props not
CL3 40 1046 26.15
C6 required
B2,B3,B4,B5,B6,
Props not
CL4 C2,C3,C4,C5,D2 92 1046 11.37
required
,D3,D4,D5,E4
2nd Floor
Load Carry
Requires Required out by
Item Column Capacity of Provide
Notation's Floor Load FoS Propping Number Of Existing FoS Remarks
Code Capacity Propping Props
Load Props Column and
Props
(DD+LL)-KN KN KN KN Nos Nos KN
iv = (i x 1.25
i ii iii = (ii/i) v vi = (iv/v) vii viii ix = (viii/i)
- ii)
A1,
Props not
CL1 A7,F1,F2,F3,F5, 115 1265 11.00
required
F6,F7
A2,A3,A4,A5,,A6
Props not
CL2 ,B1,B7,C1,C7,D1 269 1265 4.70
required
,D7, E1,E7,F4

4
Organic Jeans Ltd.
E2,E3,E5,E6,D6, Props not
CL3 229 1265 5.52
C6 required
B2,B3,B4,B5,B6,
Props not
CL4 C2,C3,C4,C5,D2 583 1265 2.17
required
,D3,D4,D5,E4

1st Floor
Load Carry
Requires Required out by
Item Column Capacity of Provide
Notation's Floor Load FoS Propping Number Of Existing FoS Remarks
Code Capacity Propping Props
Load Props Column and
Props
(DD+LL)-KN KN KN KN Nos Nos KN
iv = (i x 1.25
i ii iii = (ii/i) v vi = (iv/v) vii viii ix = (viii/i)
- ii)
A1,
Props not
CL1 A7,F1,F2,F3,F5, 197 1238 6.28
required
F6,F7
A2,A3,A4,A5,,A6
Props not
CL2 ,B1,B7,C1,C7,D1 489 1238 2.53
required
,D7, E1,E7,F4
E2,E3,E5,E6,D6, Props not
CL3 847 1238 1.46
C6 required
B2,B3,B4,B5,B6, -
CL4 C2,C3,C4,C5,D2 989 1238 1.25 -1.75 586 0.00298634 2 2410 2.44
,D3,D4,D5,E4 8

5
Organic Jeans Ltd.
Ground Floor
Load Carry
Requires Required out by
Item Column Capacity of Provide
Notation's Floor Load FoS Propping Number Of Existing FoS Remarks
Code Capacity Propping Props
Load Props Column and
Props
(DD+LL)-KN KN KN KN Nos Nos KN
iv = (i x 1.25
i ii iii = (ii/i) v vi = (iv/v) vii viii ix = (viii/i)
- ii)
A1,
Props not
CL1 A7,F1,F2,F3,F5, 308 764.9 2.48
required
F6,F7
A2,A3,A4,A5,,A6
0.33719676
CL2 ,B1,B7,C1,C7,D1 712 764.9 1.07 125.1 371 2 1506.9 2.12
5
,D7, E1,E7,F4
E2,E3,E5,E6,D6, 2.07911051
CL3 1229 764.9 0.62 771.35 371 3 1877.9 1.53
C6 2
B2,B3,B4,B5,B6,
2.80687331
CL4 C2,C3,C4,C5,D2 1445 764.9 0.53 1041.35 371 4 2248.9 1.56
5
,D3,D4,D5,E4

6
Organic Jeans Ltd.
1.1 Props load bearing capacity calculation

Fig:3 Prop load carrying capacity calculation at ground floor level

Table: 1 Load carrying capacity (KN) of Propping at different level is as follows

Level Ground floor 1st floor 2nd floor 3rd floor


Propping load 436 586 595 532
carrying capacity
(KN)

7
TITLE : Proping Details

PROJECT :

CONSULTANT :

EMKAY ENTERPRISES LTD.


IMMIDIATE PROPING LAYOUT PLAN
(GROUND FLOOR)
IMMIDIATE PROPING LAYOUT PLAN
(1st FLOOR)
IMMIDIATE PROPING CONNECTION
IMMIDIATE PROPING SECTION
DETAILS

Das könnte Ihnen auch gefallen