Beruflich Dokumente
Kultur Dokumente
Standards
Listings National Electrical Code
(NEC) OFCR, FT-4
Design and Test Criteria UL-1666 and CSA FT-4 (for
riser and general building
applications); ICEA S-104-
696
Ripcord
FR / UV-Resistant
Outer Jacket
FR / UV-Resistant
Inner Jacket
Dielectric Central
Element
Dielectric Strength and
Water-Swellable Yarns
Water-Swellable
Tape
Tight-Buffered
Fiber
Interlocking
Armor
FREEDM One Unitized Interlocking Armored Riser FREEDM One Unitized Interlocking Armored Riser
Cables, 48 Fibers Cables, 48 Fibers
Ripcord
FR / UV-Resistant
Outer Jacket
Interlocking
Armor
Dielectric Central
Element
Tight-Buffered
Fiber
Water-Swellable
Tape
Dielectric Strength and
Water-Swellable Yarns
FREEDM One Unitized Interlocking Armored Riser FREEDM One Unitized Interlocking Armored Riser
Cables, 144 Fibers Cables, 144 Fibers
Specifications
Temperature Range
Storage -40 C to 70 C (-40 F to 158 F)
Installation -10 C to 60 C (14 F to 140 F)
Operation -40 C to 70 C (-40 F to 158 F)
* Note: Corning recommends storing indoor/outdoor cable in a proper temperature environment prior to installation to allow the cable temperature to meet instal-
lation temperature range specifications for best installation results.
Fiber Count Nominal Outer Min. Bend Min. Bend Weight Number of Subunit Dia-
Diameter Radius Instal- Radius Ope- Fibers per meter
lation ration Subunit
23.7 mm 356 mm 237 mm 368.7 kg/km 4.40 mm
36 6
(0.93 in) (14.0 in) (9.3 in) (247.8 lb/1000 ft) (0.17 in)
26.2 mm 393 mm 262 mm 468.5 kg/km 4.40 mm
48 6
(1.03 in) (15.5 in) (10.3 in) (314.8 lb/1000 ft) (0.17 in)
27.4 mm 411 mm 274 mm 494.8 kg/km 5.55 mm
72 12
(1.08 in) (16.2 in) (10.8 in) (332.5 lb/1000 ft) (0.22 in)
Fiber Count Nominal Outer Min. Bend Min. Bend Weight Number of Subunit Dia-
Diameter Radius Instal- Radius Ope- Fibers per meter
lation ration Subunit
26.2 mm 393 mm 262 mm 474.56 kg/km 7.00 mm
96 24
(1.03 in) (15.5 in) (10.3 in) (318.9 lb/1000 ft) (0.27 in)
31.3 mm 469.5 mm 313 mm 672.70 kg/km 7.00 mm
144 24
(1.23 in) (18.5 in) (12.3 in) (452.0 lb/1000 ft) (0.27 in)
Chemical Characteristics
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Transmission Performance
Multimode
Fiber Core Diameter (m) 62.5 50 50 50 50
OM4 Extended
Fiber Category OM1 OM2 OM3 OM4
Distance
Fiber Code K T T T T
Performance Option Code 30 31 80 90 91
Wavelengths (nm) 850/1300 850/1300 850/1300 850/1300 850/1300
Maximum Attenuation (dB/km) 3.4/1.0 2.8/1.0 2.8/1.0 2.8/1.0 2.8/1.0
Serial 1 Gigabit Ethernet (m) 300/550 750/600 1000/600 1000/600 1100/600
Serial 10 Gigabit Ethernet (m) 33/- 150/- 300/- 550/- 600/-
Min. Overfilled Launch (OFL)
200/500 700/500 1500/500 3500/500 3500/500
Bandwidth (MHz*km)
Minimum Effective Modal
220/- 950/- 2000/- 4700/- 5350/-
Bandwidth (EMB) (MHz*km)
* 50 m multimode fiber (OM3/OM4/OM4+) meets 0.75 ns optical skew when used in all Corning Plug and Play/EDGE systems solutions.
* 50 m multimode fiber (OM4) T90 10 Gigabit Ethernet distance assumes 1.0 dB maximum total connector/splice loss.
* 50 m multimode fiber (OM4) T91 10 Gigabit Ethernet Distance assumes 0.7 dB maximum total connector/splice loss.
Single-mode
Fiber Name SMF-28e fiber SMF-28 Ultra fiber
Fiber Category G.652.D G.652.D/G.657.A1
Fiber Code E Z
Performance Option Code 31 31
Wavelengths (nm) 1310/1383/1550 1310/1383/1550
Maximum Attenuation (dB/km) 0.65/0.65/0.50 0.65/0.65/0.50
Ordering Information | Note: Contact Customer Care at 1-800-743-2675 for other options.
) $
Note: This cable is available in 12 different jacket colors blue, orange, green, brown, slate, white, red, black, yellow, violet, rose and aqua. The colored jacket
allows for easy visual identification of the cables while still providing all of the required environmental protection of an indoor/outdoor cable jacket. Black is the
standard jacket color using the part numbers shown here. Contact Customer Care at 1-800-743-2675 to order other color options.
Notes