Beruflich Dokumente
Kultur Dokumente
Coefficient of an Orifice
By: Grant Brown, Ellie Honious, Robert Means, and Mark Stamper
Density :
3
Pump 400 < < 1000
(V) Diameter of orifice (cm):
2 < D < 10
Pressure h
Transducer
(P) d
2
C = 1.0
C=0
2
=
( )2
2
=
(
2
)2
2
2
= 0.5
2
Design-phase uncertainty budget for an
experiment to determine coefficient of discharge.
Parameters Represented Value Uncertainty UMF RSSC (%) UPC (%)
Density 930.00 1.12E+02 0.5 6.02% 36.47%
3
3
Volumetric Flow 1.69E-03 - 1 6.00% 36.21%
Pressure 3
h 0.303 > 103 > 547
Transducer
(P) d
75.6 > () > 1000
Orifice Take Density
Sample () 0.826 > () > 11.0
Backup Slides
Pressure Sensor
Uncertainty
DRE Derivation
1
=
= = = =
1 2
P
1 2
= =
1 2
2 = =
2
1
1 2 = P
2 2
2 =
2
= P
Uncertainty Budget
Represented Relative
Parameters Uncertainty Reasoning UMF RSSC (%) UPC (%)
Value Uncertainty
DRE Scale and
Density 930.00 1.12E+02 12.04% 0.5 6.02% 36.47%
3 Graduated Cylinder
Volumetric Flow
3 1.69E-03 - Pump Accuracy 6.00% 1 6.00% 36.21%
1
= = 0.1 = 0.05
2 2
=
2
2
0 > D > 15.0cm
2
Density Uncertainty
=
2 2
2 = 2
+ 2
2
2
= 2
+
1
=
= 2
2 2
1 2 2
= + + 2 2
Density Uncertainty
1
Cont. = 0.2 = 0.1
2
2 2 1
1 2 2
2 = 1 = 0.5
= + + 2 2
= 1
= 930 = 0.93 for vegetable oil
3
2 2
1 9.3
= 0.52 + 12 + 0.12
10 102
= 0.112 = 112.19
Pressure Sensor Uncertainty
= 4.9
4.5
= = 0.00229
1960
= 1.5% + 3
0.005
= = 2.177
0.00229
= 2 + 2 + 2