MESC SPECIFICATION Revision: 15/08/94

SPE 60.32/069 Page 1 of 5

SPECIFICATION FOR PRESSURE TRANSMITTERS, ELECTRONIC, BLIND

GENERAL:

The pressure transmitter shall be of the direct electronic sensing type. The sensing
element shall be manufacturers standard. The diaphragm shall be hermetically
welded to the measuring element assembly which shall be suitable for operating
temperature limit -30 to 95 deg c, unless otherwise specified.

ENVIRONMENT CONDITIONS:

The pressure transmitter shall be suitable for operation in industrial, humid, saliferous
and sulphur containing surrounding atmosphere. Unless otherwise specified, the
outdoor location class shall comply with the requirements of Class D2, of IEC 654-1.

BODY:

No vent/drain connection(s) shall be present in the body.

Note: Plugging of these connections is not permitted.

OVERRANGE:

The measuring element shall be able to withstand a temporary/permanent


overpressure to at least 33% of the specified range limits without calibration shift.

MATERIALS:

All wetted parts, the diaphragm and body shall be as specified in the requisition/indent.

(C) For pressure transmitters of the differential body design, the blind body flange shall be
of AISI 316 type stainless steel, unless otherwise specified

(D)

Seal (between sensor assembly and body parts);


PTFE gaskets shall be applied as a standard, unless otherwise specified.

(C) Bolting (pressure containing);


The bolts and nuts shall be of austenitic stainless steel, hardness according to NACE
MR-01-75 (latest edition). Exact specification to manufacturer's standard, unless
otherwise specified in the requisition.

Note: Cadmium and zinc plating (galvanizing) of these bolts and nuts is not permitted.

Enclosure;
The transmitter enclosure material shall be of low copper aluminium or stainless steel
as specified in the requisition/indent.
MESC SPECIFICATION Revision: 15/08/94
SPE 60.32/069 Page 2 of 5

CONNECTIONS:

Process;
The process connection, with the exception of pressure transmitters of the differential
body design, shall be as specified in the requisition/indent.

For pressure transmitters of the differential body design, the process connection and
facing shall be compatible with din-19213, part 2,revision 1980 except for the
threading for the fixing bolts which shall be 7/16 in x 20 unf.
Orientation of the "process mounting side connection" of differential body design
pressure transmitters shall be such that facing the process connection side of the
transmitter, the "pressure" connection shall be on the right hand side.
"Opposite process mounting connection side" shall be blanked-off, tight to the rating of
the body, with blind oval (kidney) flanges. For the bolting arrangement, flange
thickness, gasket grooves and gasket for the kidney flanges refer MESC specification
609890.301

Electrical;
The electrical signal cable entry connection shall be as specified in the
requisition/indent.

Unused electrical connections shall be plugged-off with a recessed head screw in


compliance with the specified electrical safety. The screw material should be mild
steel for low copper aluminium transmitter electronics enclosures and stainless steel
for stainless steel enclosures.

The signal cable termination points shall be of the screw type.

Note: Transmitters which will have flying leads shall be provided with a junction box
for termination of these leads.

ELECTRONIC TRANSMISSION:

(C) The transmitter output signal shall be as specified.

The transmitter power supply voltage shall be 24 VDC, for 2 wire transmission system,
minimum power supply voltage 12.5 VDC.

The manufacturer should specify in his quotation the maximum allowable loop
resistance.

The transmitter output action shall be direct, unless otherwise specified. Direct or
reverse action signal output selection shall be available.

ELECTRICAL SAFETY:

The electrical safety "type of protection" shall be as specified in the requisition/indent.

ENCLOSURE:

The electronic enclosure shall be according to ip65 of IEC 529, as a minimum.

The finish of the aluminium enclosure should be manufacturer's standard, unless


otherwise specified.
MESC SPECIFICATION Revision: 15/08/94
SPE 60.32/069 Page 3 of 5

ELECTRONICS:

The transmitter electronics shall be solid-state.

Printed circuit board(s) should be of a replaceable modular construction, shall be


hermetically sealed or protected by a corrosion-resistant coating (tropicalized) and
vibration-free supported in case of plug-in type circuit boards.
Signal wiring terminals and electronics shall be housed in separate compartments, so
that the electronics remain sealed during electrical connection of the transmitter to the
signal cable.
The electronics system shall be provided with a reverse polarity protection circuit.

ADJUSTMENTS:

Zero and span shall be non-interacting easy accessible and continuously adjustable,
zero externally.
The external adjustment(s) should be provided with an environmental protection cover.

PERFORMANCE:

With reference to IEC 770, errors are expressed as a percentage of the calibrated
span, unless otherwise specified.

(C) The transmitter accuracy including combined effect of lineairity, hysteresis and
repeatability shall be as specified.

Dead Band;
The dead band shall be equal to or better than 0.05%.

Stability; (not including temperature/pressure effect)


The stability shall be better than +/-0.1% per 30 days of the minimum span.

Ambient Temperature Effect;


With reference to IEC 654-1, the rate of temperature change value shall be taken as
20 deg c per hour, unless otherwise specified.

The total dynamic effect of the temperature including span and zero error;
At maximum span, shall be equal or less than +/-1.5%.
At minimum span, shall be equal or less than +/-4.5%, unless otherwise specified.

Radio Frequency Interference;


With reference to IEC 801-3, for radio transmitters/receivers which have an
electomagnetic field with a strength of 10 vm in the frequency range between 20 and
1.000 mhz the total effect of the radio frequency interference shall be equal or less
than ?0.1% of the output span, with the transmitter enclosure cover in place.

RANGE/SPAN LIMITS AND CALIBRATION:

Measuring element range/span limits and calibrated range shall be as specified in the
requisition/indent.

RANGE ELEVATION: (IF APPLICABLE)

The transmitter range elevation shall be as specified in the requisition/indent.


MESC SPECIFICATION Revision: 15/08/94
SPE 60.32/069 Page 4 of 5

MARKING:

Transmitter body parts including blind (oval) flanges shall be marked in accordance
with the relevant material standards. Castings shall have the charge or heat number
cast in the material.

Transmitters which shall fulfil the NACE standard MR-01-75 requirements (all wetted
parts) shall be marked accordingly.

IDENTIFICATION:

The transmitter shall be provided with an identification plate, with all data clearly and
deeply stamped on a corrosion-resistant plate permanently attached to the transmitter
by means of rivets or pins. The following information shall be provided as a minimum;

- manufacturer's name or trade mark


- manufacturer's model number
- manufacturer's serial number
- body rating including units
- electrical safety "type of protection" and enclosure
- range including units of measure
- output signal including units

Notes:

1. Manufacturer's model number should include type of measuring element material


and type of fill fluid and if applicable the range elevation.

2. Electrical safety "type of protection" identification shall be identical to the one


specified in the requisition/indent.

3. The action of reverse acting transmitters shall be identified accordingly.

Each transmitter shall be provided with a stainless steel tag plate which shall be fixed
with a stainless steel wire to the transmitter. This plate shall show the purchaser's tag
number as stated in the requisition/indent.

FACTORY TESTING:

Each transmitter shall be subjected to a hydrostatic pressure test at minimum 1.25


times the body rating.

For NACE standard MR-01-75 requirements, the particular transmitter(s) shall be


subjected to a NACE hardness test (or test "samples" at the raw parts) on the body
parts and blind (oval) flanges (not measuring element).

Each transmitter shall be factory tested to meet the calibrated range requirements as
stated, calibration certificate shall be provided on purchasers request only. If the
calibrated range is not specified by the purchaser, the transmitter shall be calibrated at
the maximum pressure range.

FACTORY INSPECTION:

If specified in the purchase order the transmitter shall be inspected by the purchaser's
inspector before despatch. Unless otherwise specified, inspection by the purchaser
shall be restricted to the following:
MESC SPECIFICATION Revision: 15/08/94
SPE 60.32/069 Page 5 of 5

- visual examination and dimensional check of the process connection


- verification of testing as mentioned under factory testing
- verification of electrical safety "type of protection" certificate or declaration
- verification of material certificate (if applicable)
- verification of NACE standard MR-01-75 compliance for measuring element material
(if applicable)

CERTIFICATION:

In addition to the required "test and inspection documents" the manufacturer shall
supply a certificate stating that the transmitter complies in all respects with this MESC
description, the requisition/indent and the purchase order including the test
requirements, for the complete amount of transmitters per order.

TRANSPORT AND STORAGE:

All threaded holes shall be plugged-off with plastic caps/plugs.

GENERAL NOTES:

1. Mounting brackets shall be available as an option only.

NOTE: KEY

The following notations have been used in the margin as applicable:

(A) Added
(D) Deleted
(C) Changed