Sie sind auf Seite 1von 52

BILL No.

4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

Supply and installation of all the following Plumbing System Works,


including, but not limited to, testing, balancing and commissioning, builder's
works (sleeves, opening, supports, accessories, etc.), reinforced concrete
pads, vibration isolation, blocking, seams, sealants, neoprene, gaskets,
connection to all other related project phases, operation and maintenance
manuals, guarantee, for all required system equipment and materials, as per
contract documents, drawings and specifications.

SANITARY FIXTURES

Sanitary fixtures complete with mixers angle valves, flexible


connections, P or S traps, strainers, and all fittings and accessories
complete as specified and as shown in the drawings., all to the approval
of the Engineer:

A European Water Closet (Type WC-1), with flush valve, seat and cover,
ablution hose and all accessories complete as required and as specified.

B European Water Closet (Type WC-2), with flush valve, seat and cover,
ablution hose and all accessories complete as required and as specified.

C Lavatory (Type LAV-1), complete with mixers & all accessories complete as
required and as specified.

D Lavatory (Type LAV-2), complete with mixers & all accessories complete as
required and as specified.

E Lavatory (Type LAV-3), complete with mixers & all accessories complete as
required and as specified.

F Lavatory (Type LAV-4), complete with mixers & all accessories complete as
required and as specified.

Project No. JE-1257


Volume III 4/22/1
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

G Lavatory (Type LAV-5), complete with mixers & all accessories complete as
required and as specified.

Project No. JE-1257


Volume III 4/22/2
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SANITARY FIXTURES (Cont)

H Lavatory (Type LAV-6), complete with mixers & all accessories complete as
required and as specified.

H.1 Lavatory (Type LAV-7), complete with mixers & all accessories
complete as required and as specified.(Mentioned in Expansion Building)

H.2 Janitor Sink, including mixers and all necessary accessories, complete as
required.(Mentioned in Medical Logistic Building)

J Tubs (Type SHT), including shower mixer and all necessary accessories
complete as required.

K Wall mounted Concealed shower, including shower mixer and all necessary
accessories complete as required.

L Scrub sink (Type SCR-1), including mixers and all necessary accessories,
complete as required.

M Ablution faucet (Mentioned in the drawings for plumbing draings no


(1257B01-P101dwg)

Project No. JE-1257


Volume III 4/22/3
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/4
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION

Supply, Test and Install Soil, Waste and Vent Pipe including pipe markings,
sleeves, openings, blocking seams, sealants, bases (if required) with all
necessary fittings, brackets, hangers, supports & fixing accessories builders
work related to Plumbing works complete as specified and as shown in the
drawings.

Soil and Waste pipes (HDPE) laid underground, including excavation and
backfilling, etc. complete as specified and as shown in the drawings.

A 200 mm diameter

B 150 mm diameter

B.1 125 mm diameter (Refer to item no B page: 3 in Oncology Building)

C 100 mm diameter

D 80 mm diameter

D.1 50 mm diameter (Mentioned in Expansion Building)

Soil and Waste pipes (CAST IRON Epoxy Coated) laid under tiles, above
ceilings, in shafts and in walls, etc. complete as required

E 200 mm diameter

F 150 mm diameter

F.1 125 mm diameter (Refer to item no F page: 3 in Oncology Building)

G 100 mm diameter

Project No. JE-1257


Volume III 4/22/5
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

H 80 mm diameter

J 50 mm diameter

Project No. JE-1257


Volume III 4/22/6
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

SOIL AND WASTE PIPES INSTALLATION FOR O.R.S AND PROCEDURE ROOMS

Soil and Waste pipes (Double Wall Containment pipe system for drainage
pipes . PE 100 outer pipe and PE Inner pipe) with leak detection system,
laid above ceilings, in shafts and in walls, etc. complete as required

1.A 100 mm diameter

2.A 80 mm diameter

3.A 50 mm diameter

Vent Pipes (CAST IRON Epoxy Coated) laid under tiles, above ceilings, in
shafts and in walls, etc. complete as required

A 150 mm diameter

B 125 mm diameter

C 100 mm diameter

D 80 mm diameter

E 50 mm diameter

Pressure pipes (Cement Lined Ductile Iron) laid under tiles, at ceiling, in
shafts and in walls, etc., complete as required..

F 150 mm diameter

G 100 mm diameter

Project No. JE-1257


Volume III 4/22/7
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

G.1 50 mm diameter

Project No. JE-1257


Volume III 4/22/8
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

STORM WATER DRAINAGE PIPES

Rain Water Pipes (CAST IRON Epoxy Coated) laid under tiles, above
ceilings, in shafts and in walls, etc. complete as required

G.2 250 mm diameter (Refer to item no H page: 4 in Oncology Building)

H 200 mm diameter

J 150 mm diameter

K 100 mm diameter

L 125 mm diameter

M 80 mm diameter

N 50 mm diameter

Project No. JE-1257


Volume III 4/22/9
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/10
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

Rain Water pipes (CAST IRON Epoxy Coated) laid underground, including
excavation and backfilling.

1.A 300 mm diameter

A 250 mm diameter (Refer to item no A page: 2 in CUP Parking Building )

B 200 mm diameter (mentioned but at high level H/L pipes)

C 150 mm diameter (Mentioned in CUP Parking Building )

D 100 mm diameter

Project No. JE-1257


Volume III 4/22/11
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/12
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

ACCESSORIES

Soil and Waste pipes accessories, including Stainless steel cover, adaptors
and traps for floor drains, all necessary accessories and connections
complete as required, as shown on drawings and as specified.

1.A Ceiling Cleanout, size 250 mm diameter.

2.A Ceiling Cleanout, size 200 mm diameter.(Refer to item no A page: 5 in


Oncology Building)

3.A Ceiling Cleanout, size 150 mm diameter.(Refer to item no A page: 5 in


Oncology Building)

4.A Ceiling Cleanout, size 125 mm diameter.(Refer to item no A page: 5 in


Oncology Building)

A Ceiling Cleanout, size 100mm diameter.

B Ditto, but size 80mm diameter.

C Ditto, but size 50mm diameter.

C.1 Floor Cleanout, size 300 mm diameter.

C.2 Floor Cleanout, size 250 mm diameter. (Refer to item no D page: 5 in


Oncology Building)

D Floor Cleanout, size 200mm diameter.

D.1 Floor Cleanout, size 150 mm diameter. (Compartive to item no D page: 5


in Oncology Building)

E Ditto, but size 100mm diameter.

F Ditto, but size 80mm diameter.

Project No. JE-1257


Volume III 4/22/13
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

G Ditto, but size 50mm diameter.


H Grade Cleanout, size 150mm diameter.

J Wall Cleanout, size 100mm diameter.

Project No. JE-1257


Volume III 4/22/14
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

ACCESSORIES (Cont)

K Floor Drain type "A", size 50mm diameter.

L Floor Drain type "B", size 100mm diameter.

M Floor Drain type "C", size 100mm diameter.

N Grade Cleanout (GCO), 250 mm Diameter,(Refer to item no H page: 5 in


Oncology Building)

O Grade Cleanout (GCO), 200 mm Diameter,(Refer to item no H page: 5 in


Oncology Building)

P Roof Vent Cap, size 125mm diameter.

Q Roof drains, size 100 mm diameter.

R Ditto, but size 80 mm diameter.

S Planter drains, size 100 mm diameter.

Project No. JE-1257


Volume III 4/22/15
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/16
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

ACCESSORIES (Cont)

A Planter drains, size 50 mm diameter.(Refer to item no Q page: 5 in


Oncology Building)

B Down Spout, size 80 mm diameter.(Refer to item no N page: 8 in


Expansion Building)

C Sand Trap,size 600 mm x 600 mm x 1000 mm

D Combination main roof and over flow drains type with low silhouette
dome and double top set ,(deck plate, RD (1A,1B)(Refer to item no O
page: 5 in Oncology Building)

E Combination main roof and over flow drains type with low silhouette
dome and double top set ,(deck plate, RD (2A,2B)(Refer to item no O
page: 5 in Oncology Building)

F Floor drains, FD-1, size 50 mm diameter.(Mentioned in Medical Logistic


Building )

G Floor drains, FD-1, size 80 mm diameter.(Mentioned in Medical Logistic


Building but 75 mm diameter)

H Floor drains, FD-3, size 50 mm diameter.

J Floor drains, FD-7, size 80 mm diameter.

K Roof Vent Cap, size 100 mm diameter.(Mentioned in CUP Parking


Building )

L Roof Vent Cap, size 80 mm diameter.

M Roof Vent Cap, size 50 mm diameter.(Mentioned in Expansion Building )

Project No. JE-1257


Volume III 4/22/17
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/18
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

SOIL, WASTE AND VENT PIPES INSTALLATION (Cont)

SUBMERSIBLE DRAINAGE PUMPS

Submersible Drainage Pumps, including short length piping, vent pipe


with insect screen, valves, strainers, flexible connection all accessories,
within the chamber, stainless steel chain & steel rail, wiring, controls,
complete as required, as shown on drawings and as specified.

A Submersible pumps (in sump pit 1), capacity 70 GPM, 36 ft head approx.
grinder type (1 duty & 1 standby).

B Submersible pumps (in sump pit 3), capacity 100 GPM, 36 ft head approx.
grinder type (1 duty & 1 standby).

C Submersible pumps (in Lift Station LS-X1), capacity 165 GPM, 36 ft head
approx. grinder type (2 duty & 1 standby).

D Submersible pumps (WSP-1,2), capacity 7.2 l/s, 15 m


head approx.(1 duty & 1 standby).(Refer to item no B
page: 6 in Oncology Building)

E Submersible pumps (WSP-3,4), capacity 6.3 l/s, 15 m


head approx.(1 duty & 1 standby).(Refer to item no B
page: 6 in Oncology Building)

F Submersible pumps (FWSP-1,2), capacity 3.8l/s, 15 m head approx.(1 duty


& 1 standby).(Refer to item no A page: 6 in Medical Logestic Building)

G Single Sump Pump (EL-SP-ON 01,02,03), capacity 1.9


l/s, 15 m head approx.(Refer to item no C page: 6 in
Medical Logestic Building)

Project No. JE-1257


Volume III 4/22/19
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/20
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

WATER SUPPLY

Supply, Install and Test Cold and Hot water pipework including pipe
markings, sleeves, openings, blocking seams, sealants and base (if required)
with all necessary fittings, brackets, supports, hangers & fixings accessories,
builders work related to system complete as specified and as shown in the
drawings.

Cold water supply pipes (HDPE), laid underground, including excavation


and backfilling, etc. complete as specified and as shown in the drawings.

A 160 mm diameter.

Cold water supply pipes (Hard Copper tube) with soldered joints above
false ceilings, walls, in shafts, etc. Including all necessary fittings and
accessories, complete as required, as shown on drawings and as specified.

B 15 mm diameter.

C 22 mm diameter.

D 28 mm diameter.

E 35 mm diameter.

F 42 mm diameter

G 54 mm diameter.

H 67 mm diameter.

J 76 mm diameter.

J.1 92 mm diameter.(Refer to item K,Page-7, Oncology Building)

K 108 mm diameter.
Project No. JE-1257
Volume III 4/22/21
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

L 133 mm diameter.

M 155 mm diameter.(Mentioned in Expansion Building but 159 mm is the


standard size)

Project No. JE-1257


Volume III 4/22/22
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

WATER SUPPLY (Cont...)

A Allow for the Connection of Cold water supply pipes (Hard Copper tube)
with soldered joints to Oncology Building and Site Loop Including
additional pipe length with all necessary fittings and accessories, complete
as required, as shown on drawings and as specified

Hot water supply and return pipes (Hard Copper tube) with soldered joints
above false ceilings, walls, in shafts, etc. Including all necessary fittings
and accessories, complete as required, as shown on drawings and as
specified.

B 15 mm diameter.

C 22 mm diameter.

D 28 mm diameter.

E 35 mm diameter.

F 42 mm diameter

G 54 mm diameter.

H 67 mm diameter.

J 76 mm diameter.

J.1 92 mm diameter.(Refer to item, K,page-8,Oncology building)

K 108 mm diameter.

Project No. JE-1257


Volume III 4/22/23
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

L Allow for the Connection of Cold water supply pipes (Hard Copper tube)
with soldered joints to Oncology Building and Site Loop Including
additional pipe length with all necessary fittings and accessories, complete
as required, as shown on drawings and as specified

Project No. JE-1257


Volume III 4/22/24
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

WATER SUPPLY (Cont...)

Hot water supply and return pipes Insulation (12mm thick Euroflex)
Including all necessary fittings and accessories, complete as required, as
shown on drawings and as specified.

A 15 mm diameter.

B 22 mm diameter.

C 28 mm diameter.

D 35 mm diameter.

E 42 mm diameter

F 54 mm diameter.

Hot water supply and return pipes Insulation (32mm thick Rigid Fiberglass
with Aluminum foil) Including all necessary fittings and accessories,
complete as required, as shown on drawings and as specified.

G 67 mm diameter.

H 76 mm diameter.

J 90 mm diameter.

J.1 92 mm diameter.(mentioned in oncology Building)

K 110 mm diameter.

L 108 mm diameter.(Mentioned in Expansion Building)

Project No. JE-1257


Volume III 4/22/25
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/26
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

WATER SUPPLY (Cont...)

Cold and Hot water pipes accessories Including all necessary fittings,
complete as required, as shown on drawings and as specified.

A Ball valve, 15 mm diameter

B Ditto but 22 mm diameter

C Ditto but 28 mm diameter

D Ditto but 35 mm diameter

E Ditto but 42 mm diameter

F Ditto but 54 mm diameter

G Ditto but 63 mm diameter

H Ditto but 76 mm diameter

J Ditto but 90 mm diameter

K Ditto but 110 mm diameter

L Gate Valve, OS & Y Type, 54 mm diameter

M Ditto but 110 mm diameter

N Ditto but 133 mm diameter

O Balancing Valve 54 mm diameter

P Hose bibb , fixing to 22 mm diameter pipe.

Q Shock Hammer arrestors (SHA)

Project No. JE-1257


Volume III 4/22/27
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

R Electronic Trap Primer Manifold (TP)

Project No. JE-1257


Volume III 4/22/28
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

WATER SUPPLY (Cont...)

Accessories (Cont...)

A Gate valve, 15 mm diameter,Mentioned in Medical Logistic Building

B Gate valve, 22 mm diameter,Mentioned in Medical Logistic Building

C Gate valve, 28 mm diameter,Mentioned in Medical Logistic Building

D Gate valve, 35 mm diameter,Mentioned in Medical Logistic Building

E Gate valve, 42 mm diameter,Mentioned in Medical Logistic Building

F Gate valve, 54 mm diameter,Mentioned in Oncology Building

G Gate valve, 67 mm diameter(Refer to item no D.1 page: 9 in Medical


Logestic Building)

H Gate valve, 76 mm diameter(Refer to item no D.1 page: 9 in Medical


Logestic Building)

J Gate valve, 92 mm diameter(Refer to item no D.1 page: 9 in Medical


Logestic Building)

K Gate valve, 108 mm diameter,Mentioned in Oncology Building

L Gate valve, 133 mm diameter,Mentioned in Oncology Building

Automatic Air Vent (AAV), 28 mm diameter,Mentioned in Medical Logistic


M
Building but size is not mentioned

Project No. JE-1257


Volume III 4/22/29
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

N Globe valve, 15 mm diameter,Mentioned in Medical Logistic Building

Project No. JE-1257


Volume III 4/22/30
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

WATER SUPPLY (Cont...)

Accessories (Cont...)

A Globe valve, 22 mm diameter(Refer to item no E page: 9 in Medical


Logestic Building)

B Globe valve, 35 mm diameter(Refer to item no E page: 9 in Medical


Logestic Building)

C Globe valve, 42 mm diameter(Refer to item no E page: 9 in Medical


Logestic Building)

D Check valve, 15 mm diameter,Mentioned in Expansion Building

E Check valve, 22 mm diameter,Mentioned in Expansion Building

F Check valve, 35 mm diameter,Mentioned in Expansion Building

G Check valve, 42 mm diameter,Mentioned in Expansion Building but 40 mm


diameter

H Water hammer arrestors, 15 mm diameter,Mentioned in Medical Logistic


Building

J Water hammer arrestors, 28 mm diameter,Mentioned in Medical Logistic


Building

K Water hammer arrestors, 35 mm diameter,Mentioned in Medical Logistic


Building

L Back water valve, 54 mm diameter

M Back water valve, 35 mm diameter

N Back water valve, 22 mm diameter


Project No. JE-1257
Volume III 4/22/31
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/32
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

COMPRESSED AIR PIPEWORKS

Supply, Install and Test Compressed Air pipework for Laboratory and Health
care Facilities including pipe markings, sleeves, openings, blocking
seams, sealants and bases (if required) with all necessary fittings,
brackets, supports, hangers and fixing accessories complete as required, as
shown in the drawings and as specified.

Medical Air pipes (Copper, Type L, Seamless) above false ceilings, in


walls, in shafts, etc. Including all necessary fittings and accessories,
complete as required, as shown on drawings and as specified.

A 12 mm diameter.

B 15 mm diameter.

C 22 mm diameter.

D 28 mm diameter.

E 35 mm diameter.

F 42 mm diameter

G Allow for the Connection of Medical Air pipes to Oncology Building


Including additional pipe length with all necessary fittings and accessories,
complete as required, as shown on drawings and as specified

Project No. JE-1257


Volume III 4/22/33
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/34
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

COMPRESSED AIR PIPEWORKS (Cont.)

Surgical Air pipes (Copper, Type L, Seamless) with soldered joints above
false ceilings, walls, in shafts, etc. Including all necessary fittings and
accessories, complete as required, as shown on drawings and as specified.

A 12 mm diameter.

B 22 mm diameter.

C 28 mm diameter.

D Allow for the Connection of Surgical Air pipes to Oncology Building


Including additional pipe length with all necessary fittings and accessories,
complete as required, as shown on drawings and as specified

Nitrous Oxide (N2O) pipes (Copper, Type L, Seamless) above false


ceilings, in walls, in shafts, etc. Including all necessary fittings and
accessories, complete as required, as shown on drawings and as specified.

E 15 mm diameter.Mentioned in Expansion Building

F 22 mm diameter.Mentioned in Expansion Building

G Allow for the Connection of Nitrous Oxide (N2O) to Oncology Building


Including additional pipe length with all necessary fittings and accessories,
complete as required, as shown on drawings and as specified

Project No. JE-1257


Volume III 4/22/35
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/36
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

COMPRESSED AIR PIPEWORKS (Cont.)

Anaesthetic Gas Scavenging System (AGSS) pipes (Copper, Type L,


Seamless) above false ceilings, in walls, in shafts, etc. Including all
necessary fittings and accessories, complete as required, as shown on
drawings and as specified.

A 28 mm diameter.(Mentioned in Expansion Building )

B 35 mm diameter.(Mentioned in Expansion Building )

C 42 mm diameter.(Mentioned in Expansion Building )

D Allow for the Connection of Anaesthetic Gas Scavenging System (AGSS)


to Oncology Building Including additional pipe length with all necessary
fittings and accessories, complete as required, as shown on drawings and as
specified

Project No. JE-1257


Volume III 4/22/37
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/38
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

MEDICAL VACCUM PIPEWORKS

Supply, Install and Test Medical Vacuum pipework for Laboratory and
Health care Facilities including pipe markings, sleeves, openings,
blocking seams, sealants and bases (if required) with all necessary
fittings, brackets, supports, hangers and fixings accessories complete as
specified and as shown in the drawings.

Medical Vaccum pipes (Copper, Type L, Seamless) above false ceilings,


in walls, in shafts, etc. Including all necessary fittings and accessories,
complete as required, as shown on drawings and as specified.

A 15 mm diameter.

B 22 mm diameter.

C 28 mm diameter.

D 35 mm diameter.

E 42 mm diameter

F 67 mm diameter.

F.1 76 mm diameter,(Mentioned in Expansion Building )

G Allow for the Connection of Medical Vaccum pipes to Oncology Building


Including additional pipe length with all necessary fittings and accessories,
complete as required, as shown on drawings and as specified

Project No. JE-1257


Volume III 4/22/39
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/40
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

MEDICAL GAS PIPEWORKS (Cont.)

Medical Oxygen gas pipes (Copper, Type L, Seamless) above false


ceilings, in walls, in shafts, etc. Including all necessary fittings and
accessories, complete as required, as shown on drawings and as specified.

A 12 mm diameter.

B 15 mm diameter.

C 22 mm diameter.

D 28 mm diameter.

E 35 mm diameter.

E.1 42 mm diameter.(Mentioned in Expansion Building )

F Allow for the Connection of Medical Vaccum pipes to Oncology Building


Including additional pipe length with all necessary fittings and accessories,
complete as required, as shown on drawings and as specified

Medical Nitrous oxide, Oxygen & Carbon di oxide gas Piping accessories
Including all necessary fittings, complete as required, as shown on
drawings and as specified.

G Ball valve, 15 mm diameter

H Ball valve, 22 mm diameter

J Ditto but 28 mm diameter

K Ditto but 35 mm diameter

L Capped End (sizes as per the drawings)


Project No. JE-1257
Volume III 4/22/41
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/42
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

MEDICAL GAS PIPEWORKS (Cont.)

Accessories (Cont.)

A Lockable ball valve, 15 mm diameter,(Mentioned in Oncology Building )

B Lockable ball valve, 22 mm diameter,(Mentioned in Oncology Building )

C Lockable ball valve, 28 mm diameter,(Mentioned in Oncology Building )

D Lockable ball valve, 35 mm diameter,(Mentioned in Oncology Building )

E Lockable ball valve, 42 mm diameter,(Refer to item no. K page: 14 in


Oncology Building)

F Regulating valve (RV), 28 mm diameter

G Regulating valve (RV), 35 mm diameter

Project No. JE-1257


Volume III 4/22/43
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/44
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

MEDICAL GAS PIPEWORKS (Cont.)

AREA VALVE SYSTEM UNITS

Zone Service Unit and Alarm Panel for medical gases including all
necessary fittings, complete as required, as shown on drawings and as
specified.

A AVSU 1

B AVSU 2

C AVSU 3

Medical Warning and Alarm System

D Supply, Install, Test and Commisioning of Medical Alarm System For


Medical Gases Includes Master Pannel, Area Alarm, Control Wires,
Pressure Sensors, Power Supply, End of Line Components, Transmitter,
Repetor Pannels in Engineering Office,Plant to Alarm Interfaces to
Complete the Job.

Wall Mounted Medical Gas Outlets

E Supply, install, wall mounted medical GasesOutlet & Piping accessories


the and all outlets related to patients room are including in the bedhead
units and paum

F N2O outlet,Mentioned in Expansion Building

G O2 outlet ,Mentioned in Expansion Building

H Medical Air outlet ,Mentioned in Expansion Building

J Medical Vacuum outlet, Mentioned in Expansion Building

Project No. JE-1257


Volume III 4/22/45
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

K Anaesthetic Gas Scavenging System outlet,Mentioned in Expansion


Building

Project No. JE-1257


Volume III 4/22/46
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

PLUMBING SYSTEM

MEDICAL VACUUM EQUIPMENT

Supply, Install and Test Medical Vacuum Equipment for Laboratory and
Health care Facilities including valves, gauges, controls, reinforced
concrete base, vibration isolators and all necessary fittings, supports &
fixings accessories complete as required , as shown in the drawings and
as specified.

A Medical Vacuums, Ref - VAC-ONC, capacity of 1520 l/m free air


asprirated including valves , 4 no of vacuum pumps , 2 no of Recever
(4000 L volume) and all necessary accessories, complete as required,
as shown on drawings and specified.

Anaesthetic Gas Scavenging System Equipments

Supply, Install, Test and Commissioning of Medical Anaesthetic


Equipment according to HTM-02 01 Requirements , With Fully
automatic operation with Duplex Lateral Chanel Exhaust Meter And to
be Able to Discharge Polluted Air Out Side Building including valves,
gauges, controls,Bacterial Filters, Drain reinforced concrete base,
vibration isolators and all necessary fittings, supports & fixings
accessories complete as required , as shown in the drawings and as
specified.

B Anesthetic Gas Scavenging System, Ref - AGSS-ONC capacity of , 840


l/ m (net plant output) including valves and all necessary accessories,
complete as required, as shown on drawings and specified.(Refer to
item no. E page: 30 in Expansion Building )

Project No. JE-1257


Volume III 4/22/47
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/48
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

CIVIL WORKS RELATED TO PLUMBING

Manhole catch basin including excavation, backfill, concrete works,


water proofing, manhole cover and frame, ladders and other accessories,
etc., complete as specified and as shown in the drawings.

A Lift Station No. 1, LS-X1, 2500mm x 4916.7mm x 4550mm

B Sump Pit (1) - 2m x 2m x 2.5m

C Sump Pit (2) - 2m x 2m x 2.5m

D Sump Pit (3) - 2m x 2m x 2m

E Trench Drain with Grating Cover, 455mm wide x 7585mm long

F Sump Pit (1) , 2 m x 2 m x 2.7 m(refer to item no. B page: 16 in Oncology


Building )

G Sump Pit (2) , 2 m x 2 m x 1.9 m(Refer to item no. B page: 16 in Oncology


Building )

H Sump Pit (16) , 1.5 m x 1.5 m x 1.5 m (Mentioned in CUP Parking


Building )

J Elevator Pit (7) , 0.6 m x 0.6 m x 0.6 m(Refer to item no. B page: 16 in
Oncology Building )

K Elevator Pit (8),0.6 m x 0.6 m x 0.6 m(Refer to item no. B page: 16 in


Oncology Building )

L Sand Trap,size 600 mm x 600 mm x 1000 mm

Project No. JE-1257


Volume III 4/22/49
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Project No. JE-1257


Volume III 4/22/50
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

BILL No. 3
DIVISION 22 - PLUMBING

Project No. JE-1257


Volume III 4/22/51
KFSH & RC
B01 - Oncology Bldg.
BILL No. 4
DIVISION 22
PLUMBING

Item Description

Carried to Summary

Project No. JE-1257


Volume III 4/22/52
KFSH & RC
B01 - Oncology Bldg.

Das könnte Ihnen auch gefallen