Sie sind auf Seite 1von 23

THE JLAH TEPEFACTION REGENERATION

ADSORPTION TYPE DRYER

Operation and maintenance manuals

HANGZHOU JIALONG AIR EQUIPMENT CO., LTD.


2014
Catalogue

1. Introduction........................................................................................................1

2. Overview of working principle.......................................................................... 2

3.Technologic Flow................................................................................................. 3

4. Technical Parameter...........................................................................................4

5.Control System.................................................................................................... 5

6.System Disposition..............................................................................................6

7.Operation.............................................................................................................7

8.Breakdown and Settlement................................................................................9

9.Main parts and wearing parts list.................................................................... 11

10. Preventive maintenance and project list......................................................13


Hangzhou Jialong Air Equipment Co., Ltd

1. Introduction
Hangzhou Jialong Air Equipment Co., Ltd. is specialized in the production of compressed
air dryer manufacturers, pivotal in the air purification industry, also enjoys a high reputation
in the majority of users. In order to further expand the market, to meet user requirements,
my company to absorb advanced technology to digest foreign nineties adsorption dryer, fully
draw on the experience of the development of the domestic like product launched the
JLAH-type micro-thermal regeneration sucking machine to the majority of users.
The JLAH-type micro heat regenerative dryers has
been in hot pursuit of international advanced
technology, continue to provide customers with higher
technological content, the better the product. In
October 2002, Jialong company signed a long-term
cooperation agreement with Japan's largest
compressed air after-treatment equipment
manufacturers (Ocean NPS Giken Co., Ltd.), The Japan
Ocean Giken Co., Ltd. was established in 1974, with
strong technical strength and advanced manufacturing
level, Jialong company backed by the Japanese Ocean
Giken powerful technology strength , product quality
and technology has reached advanced domestic level,
and increasingly close and reached the international
advanced level.
The main content of this manual is to guide users
how to properly use the equipment and do general
maintenance work. Aims to extend the useful life of
equipment, reduce equipment failures, in order to
ensure the quality of compressed air. Read this manual
before using the equipment must be in accordance with the instructions, operation and
maintenance, and avoid equipment failure.

User if not in this manual operation and do general maintenance, and the
Company makes no warranty liability.

1 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

2. Overview of working principle


It conducts absorption drying of compressed air through self-heating and slight-heating
regeneration method under principle of temperature-pressure swing adsorption. It has
Heating-less regeneration (PSA) adsorption type dryer structure is simple, high degree of
automation a, Less air consumption than hot regeneration (TSA )dryer,, the depth of the
advantage of desorption. To avoid Heating-less regeneration (PSA) adsorption type dryer big
air consumption, frequent switching and hot regeneration (TSA )dryer structure is complex
the power consumption of the big weakness, the comprehensive index has obvious
advantages.
The double-tower structure is used in The JLAH Adsorption Type Dryer: one tower
absorbs moisture in the air at air inlet pressure and low temperature, part of the dry air in
another tower regenerate the absorbent in the absorbing tower in the condition of low
pressure and high temperature. After a set time, the two towers exchange to ensure the
continuous supplying of the dry compressed air. The actual running procedure of each tower
is divided into 3 stages: absorb regenerate re-pressurize(include heat and cool
regenerate).
The function of users manual is to guide the users how to used this equipment
correctly and make daily maintenance. Users should read this manual fluently before using.

2 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

3.Technologic Flow
The JLAH-Type dryers process flow diagram,Shown in the following diagram.
The compressed air enters into Tower A through IA, then the air is desiccated. The
desiccated air goes to the outlet from CA, and part of the air is separated as the regenerating
air before going to the outlet, after the flow control by RV, then it goes to B from OB after
heated by H. There is moisture absorbed in the last half period in B. The regenerating
air .brings all these moisture and eliminated by RB and MF. It is the heat reg The JLAH-Type
dryers process flow diagram,Shown in the following diagram eneration stage. After a set
time, H cut, then the regenerating air cool Tower B for the next half-period. It is the cool
regeneration stage. Then, RB closes, Tower B begins to raise the pressure till the pressure of
two towers is balanced. It needs time to raise the pressure to ensure the balance of pressure
of two towers. Otherwise, it would cause the pressure undulating in the outlet. After half
recycling period, IA closes and IB opens. Concerning the time of the procedure that the valve
need, RA open again after 6 seconds. Now Tower B begins to dry air, and the Tower A enters
the regeneration status, thus an exchange has been finished. After half period working, the
Tower B returns to the regeneration status. This period is a recycling time.
In a recycling period, each absorbing tower passed 3 stages: absorb regenerate
(include heat and cool regenerate) re-pressurize. The procedure is controlled by Siemens
LOGO!PLC.

Air outlet Air outlet

Air inlet Air inlet


A tower drying, B tower regenerating B tower drying, A tower regenerating

3 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

4. Technical Parameter
Table 1 Basic technical parameters
(The actual project drawings shall prevail)
JLAH1050
3
Normal inlet flow (Nm /min) 34
Inlet presurre Bar 7
Inlet temperature () 45
Consumption of regenerated ai 4-8 Inlet air flow
Presure loss Bar 0.3-0.4
Dew-point of gas in the exit () -20~-45
Regenerating way Heat regeneration
2 towers exchange and continue working, the exchange
Working way
cycle is 120min
Operating way Fully-automatic PLC program control
Power supply 380V / 50Hz /3PH
Heater power (kW) 8

Weight ( kg) ~1000

L 2062

Outside size (mm)


W 950
LengthWidthHeight
H 2370

Air inlet/outlet connection DN80 Flange

Note:
1Intake air flow rate is defined as the intake pressure of 7Bar, the temperature was 38 C, the inlet air
relative humidity is 100% of the import condition saturated compressed air is converted to an absolute
pressure of 1 Bar, the temperature was 20 C of the predetermined conditionsdryer into the volume of air
flow, the same below
2The regeneration gas consumption varies according to the size of the inlet air pressure, high pressure,
gas consumption is small; pressure is low, the gas consumption of large
3Inlet / Outlet flange welded flange sudden panel equipped with metric pipe, flange standard for the
Ministry of Chemical Industry Standard HG20592
4Dimensions are subject to change without notice
5The table pressure If not specified, all refer to gauge pressure, the same below

4 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

5.Control System
The system program is reached by PLC. The system work Periodic Table are shown in
Table 2. The entire system of electrical wiring diagram see attached page.

Table 2 Periodic Table


Working
1/2 period (60 min) 1/2 period (60 min)
period
I II III IV
Time
6s 29min54s 28min30s 1min30s 6s 29min54s 28min30s 1min30s
Time Heat Cool Pressur
Tower A Dry
delay regenerate regenerate e filling
Time Heat Cool Pressur
Tower B Dry
delay regenerate regenerate e filling

Control system

Photos are for reference only, specific in kind prevail

5 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

6.System Disposition
In order to ensure the quality of compressed air after the treatment by the dryer and to
prolong the lifetime of dryer, the following items should be concerned in the installation:
1) Pre-filter should be installed in the entrance of the dryer to deal with the liquid water,
solid particle and oil aerosols. If the liquid water enters directly into the absorbing tower, it
would badly damage the running condition of the dryer to greatly raise the dew point in the
outlet and even make failure operation of the dryer. And the oil aerosols will extremely
pollute the absorbent: not only raise the dew point, but also shorten the life time of the
absorbent. To lengthen the service life of the filter, it is recommended that the user from
coarse to fine filtering and summarized the way to filter configuration.
Recommended configuration the Company production of Grade 9 filter as a coarse filter,
After the filtered with a filter, compressed air content of solid and liquid particles 3m,
the oil mist residual content 5ppm.
At level Grade 9 filter after , the recommended configuration the company produces the
Grade 5 filter as oil filter After the filtered with a filter ,compressed air content of solid and
liquid particles 0.01 u m, oil mist residual content of 0.01 PPM.
2).The rubbing of the absorbent will bring some dust. To ensure the clean of the air,
normally we should install post-filter. According to the different requirement of the quality
degree of the compressed air, users could dispose different post-filter. For the higher using
requirement, you could add other filters behind this filter.
We recommend you JHF7-grade filter. After the filtered with a filter, compressed air
content of solid and liquid particles 1 m, the oil mist residual content 1ppm.
3). User should put in by-pass valve, closing valve and releasing valve in the system
disposition to ensure the successive gas supplying in the lower reaches when it is in the
maintenance.
4). Reliable ground-connection set is necessary to be put in this equipment.

Figure II System Configuration Diagram

6 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

7.Operation
7.1 Open the equipment
7.1.1 Close the air exit valve, releasing valve set by the user and open the by-pass valve,
slowly open the air inlet valve set by the user in order to raise the pressure of the dryer to
working level; adjust the pressure regulator valve in the front of pneumatic valve to regulate
the pressure around 2 Bar and lock.
7.1.2 Open the switch in the panel of controller to power on the dryer.
7.1.3 Slowly open the air outlet valve after several minutes normal running of the dryer.
7.1.4 Close the by-pass valve of the dryer.
7.2 Shut the equipment
7.2.1 Close the switch in the panel of controller to power off the dryer.
7.2.2 Disconnect the circuit breaker in the electrical box, The dryer is powered off. Power
LED off
7.2.3 Close the air inlet and outlet valve of the dryer.
7.2.4 Slowly open the releasing valve till the pressure of the two towers is zero.
7.3 Maintenance
7.3.1 Filter regulator outlet pressure is not in the normal range, the Pressure regulating knob
need to adjust the filter regulator adjustment method: pull up the
upper part of the filter regulator knob clockwise rotation pressure,
counterclockwise rotation decompression, and so reach the desired pressure
reduction knob lock(0.4Mpa). Users should regularly is cleaning the filter
regulator filter body, in order to ensure the quality of the air cleaning
method: rotate and pull down the lower body of the bayonet cup, with a
neutral detergent solution to clean the filter and cups. Filter regulator for
automatic drainage way, users should install drainage pipes to the
appropriate location. (Filter regulator is usually placed in the electrical box
below.)
7.3.2 Regeneration gas is too big or too small, need to adjust gas regulating
valve. Adjust when a time turning a twice regulate dryer running two cycles
and then as the case may be adjusted. The regeneration gas control valve is
usually located in the top of the device. (JLAH-10, and the following models
of micro gas regulating valve.)
7.3.3 Regeneration gas heating temperature is too high or too low, the need
to adjust the heating temperature setting upper and lower limits. The lower
limit adjustment: temperature controller (tipping the electrical box door)
panel switch switch to the lower limit position (when the lower limit set value), with a small
screwdriver to rotate the lower limit regulation switch will be located set temperature to
normal, clockwise to increase the temperature on the contrary reduce, adjust the switch
reversal measurement file upon completion the ceiling set adjustment: Refer to the lower
limit of the adjustment. Temperature setting: the lower limit of 80 C, the upper limit of
7 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

120 C.
7.3.4 While the dryer is in work, the pressure of the regenerating tower should not surpass
0.2 Bar. If it surpasses this value, the valves maybe no have malfunction, or the muffler jam.
The muffle should be taken apart immediately to clean the clog. If it is badly jammed and not
capable to clean, the muffler should be changed.
7.3.5 Dryer after running for some time, the dry bed sink slightly to check and supplement or
replace the desiccants. Desiccants should be screened prior to loading, remove the dust and
make it uniform particles.
7 3 6 Regularly check the work of each valve and seal state.
7.3.7 Regularly check the electrical components are in good contact, often clear the inside
and outside of the dust distribution box.
7 3 8 Runtime muffler sometimes a small amount of drainage, which is a normal
phenomenon, such as the massive drainage please refer to the failure and exclusion

8 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

8.Breakdown and Settlement

Appearance of
No. Analysis of Reason Settlement
breakdown
No current input. Check the voltage.

Power switch malfunction. Change the switch.


Turn the Switch, the
1
dryer doesnt work. Breaker isnt open. Change the breaker.
Electrical equipment is Check connection or change
fault. the electrical equipment
Air flow surpasses the Change the dryer with more
maximum. capacity.

Absorbent is out of date. Change the absorbent.


The dew-point is too Change the absorbent after
2 Absorbent is polluted.
high. checking of the pre-filter.

The pressure of air is too


Raise the air pressure or
low or the temperature is
lower the temperature.
too high.

Working pressure has The regeneration valve is Check and repair the
not reached the not closed tightly. regeneration valve.
3
working level while The dried compressed air is Reduce the output of the
pressure filling. too much. dried compressed air.
The muffle is jammed. Clean or change the muffler.

The pressure of the The regeneration valve has Check and repair the
4 regeneration tower is not been open totally. regeneration valve.
higher than 0.2 Bar.
The sealing of the check Check and repair check
valve is not good. valve.

Exhaust valveRA\RB fault Repair or replacement


can not open

Controlling the exhaust


Run when the two valve of the Replace the solenoid valve
5 towers were pressure electromagnetic valve
(not switch) failure
The controller does not
Replacement or contact
output the program does
manufacturers
not or hardware problem
9 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

Pressure relief valve


Adjust the pressure
pressure too
Replacing the switching
Switching valve fault
valve
Control intake valve IA, IB
Replace the solenoid valve
solenoid valve fault
The controller does not
Run time muffler output the program does Replacement or contact
6 manufacturers
exhaust is big not or hardware problem
Foreign body stuck check
Repair or replacement
valve or fault
Off small and then angry
Get angry too big
valves

Pre-filter drainage poor Shimizu drain or replace

The muffler when Regeneration gas is too Increase renewable gas


7 running a large small
number of drainage
Regeneration temperature Increase the regeneration
is too low temperature

Clogging of the filter Replace the filter


Equipment runtime element
8
pressure drop
Equipment leak Eliminate leak

10 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

9.Main parts and wearing parts list


Compressed air dryer parts list

Project Part Name Drawing No. Unit Qty Remarks
No. Specifications
Y Y type filtering ball
1 JAL23D991 pcs 3
valve Wearing parts

2 Automatic drainer JAL21D200 pcs 3
Wearing parts
JLF9F1050 Pre Consumable
3 JAL55E981D pcs 2
filter parts
JLF5F1050 Oil Consumable
4 JAL25E711D pcs 2
element filter parts
JLF7F1050 Dust Consumable
5 JA35E876D pcs 2
element filter parts
Consumable
parts(Using
6 JAL31A091 Kg 700
Super special adsorbent 8000-16000 hours to
check & replacement)

7 Silencer JAL29A758 pcs 2
Wearing parts

8 Diffuser JAL27A327 pcs 4 Wearing parts(When
replacing adsorbent)
Pneumatic Preparation
9 JAL37A132 pcs 2
control valve IN parts

Pneumatic Preparation
10 JAL39A889 pcs 2
control valve OUT parts
Preparation
11 Electromagnetic valve JAL27D873 pcs 4
parts
Preparation
12 JAL33D632 pcs 1
Filter pressure reducing valve parts
Exhaust gas check
13 JAL32A661 pcs 2
valve
Regeneration of
14 JAL32A789 pcs 2
check valve
15 Air pressure gauge JAL28D307 pcs 2
PLC The
16 PLC program controller JAL24C879 pcs 1
Containing procedures
PLC The PLC
17 expansion modules JAL24C709 pcs 1
Containing procedures
18 Temperature probe JHL30M pcs 1
19 Changeover switch JHL30MZHKG pcs 1
()Indicator lamp
20 JHL30MZSD pcs 3
red green yellow
Electric heater
21 JHL30 pcs 1
core
The temperature
22 JAL22C110 pcs 1
controller
11 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

Remark
In order to ensure the long-term and stable operation of the equipment, please prepare some spare parts,
such as: Y type filtering ball valveAutomatic drainerPre filterOil element filterDust element filter
Super special adsorbentSilencerDiffuser

12 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

10. Preventive maintenance and project list



Commodity
No. Maintenance cycle time The main work content
Specifications

Y
1. Confirm if the drainage is unobstructed,
Y type filter ball valve Daily check
cleaning strainer if necessary
(
)

Confirm if the drainage is unobstructed,
floating ball
2. cleaning strainer if necessary (suggest
automatic drainage Daily check
installation manual drainage bypass
device
pipeline in front of the automatic drainage
device)
4000-8000H

3. Check once per
Air filter Replace filter element of air filter once
4000-8000H
8000H
4.
adsorbent Check once per 8000H Check the adsorbent, replace if necessary

8000H
5. Each replacement of adsorbent should
Air diffuser Check once per 8000H
replace the diffuser meanwhile
0.4Mpa

6. Filter relief pressure Check the pressure setting, adjust to
Once a week
valve 0.4Mpa

80 150
Check the heater temperature setting
7.
Heater temperature Once a week limits, minimum general conditions is 80
, 150 is maximum



Cleaning the
8. Wipe the dust and oil outside the
appearance of Once a week
equipment
equipment


9. Cleaning the Electrical Blowing the dust on the electrical box
Once a week
box bottom and electric component

10.

13 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

Compressed air dryer performance guarantees

1 Running Reliability Assurance


The company not only has senior technical staff, but also has a strong ability to
develop actual experienced technical team, in the production of a set of the complete work
process card and corporate standards.

2the assurance of the ability to adapt to the Variable Work Condition


The Company dryer is designed according to the actual situation of our climate.

2 This product uses standard: JB/T 10532-2005 Adsorption compressed air dryers for
general useQ / HJL 002-2012Enterprise standard.

Thank you for using the dryer for the production. The quality of the products will give
your company a very good value for money and a good product. Addition to provide the best
after-sales service, the company also continued to study the development of compressed air
purification products; such as: efficient compressed air-cooler, the air tank, efficient oil
removal and efficient level filter, main production pressure swing adsorption nitrogen,
oxygen plant, if necessary, please contact the company.
If you are in the installation, use the company's products, If you have any questions or
unknown place, please call the communication links, we will be the fastest and best way to
serve you!

14 / 15
Please consider the environment before printing this document
Hangzhou Jialong Air Equipment Co., Ltd

Quality Assurance book

1. Hereby warrant dryer manufactured by the Company in Miho period, under normal
circumstances, such adverse circumstances, be borne by the company responsible for
the free repair, but your organization must be in accordance with the provisions of the
Company Manual, to do regular maintenance.
2. Dryer conditions, must be in compliance with the request of the Company, subject to
change, notify our service personnel to come forward to discuss treatment, in order to
maintain the efficiency and life of the machine.
3. The company will provide you with the relevant technical information, for you to make
the most perfect after-sales service to ensure your satisfaction.

15 / 15
Please consider the environment before printing this document
We always strive to provide users with more clean compressed air

HANGZHOU JIALONG AIR EQUIPMENT CO.LTD


Address: NO.168,Wuxing village,Qiaosi Street, Yuhang District, Hangzhou, China
Tel: 0571-85365111
Fax: 0571-85365000
Server:400-103-8600
Post code: 310001
E-Mail:13588827999@163.com
http://www.jialongequip.com.cn

CompressedAirF ilter

Operationandmaintenancemanuals






HANGZHOUJIALONGAIREQUIPMENTCO.,LTD.
2014
Hangzhou Jialong Air Equipment Co., Ltd

1.ProductBriefing
For the compressed air filters, all the filtration cores refer to the originalstate products by the
worldfamous Hangzhou Jialong Company and the shells of the filters are designed according to the
prototypeofJialongCompany,includingfivegradesofGrade9,Grade7,Grade5,Grade3andGrade1,
etc.bydifferentdegreesoffiltrationprecision.
Thecompressedairrunsintothefilterandremoveseffectivelythecontaminantssuchasmoisture,
dustandoilfume,etc.inthecompressedair,thusthecompressedairismadecleananddrytoimprove
the reliability of the pneumatic equipment and the quality of the product. As the filtration cores of
HANKISON Company are constructed with multilayer filter bed, their extremely high dust containing
capacity,higheffectivenessandlonglifespanhavebeenunanimouslyrecognizedintheworldcompressed
air purification equipment domain. The filters made by our company are simple in structure, easy for
filter cores to be mounted and dismantled and secured in operation performance. We provide the
following5gradesoffiltersforyourselection.

2.Filterspecification
HF9(JLF9)GradeMainPipelineFilterElement

Removablestainlesssteelmeshcore,Separationof10 ormoresolidandliquidparticlesbycentrifugal

force

Replaceableglassfiberfilter3 ormoresolidandliquidparticlescompletely,Thegravityactionbrings

thewateratthebottomofthefilteranddischargethewater.

1ppmoilmistresidualcontent

HF7(JLF7)GradeMainPipelineFilterElement

Corrosionprotectionforinnerandouterlayeroffilterelement

Multilayerglassfiberfilterssolidandliquidparticleswhichismorethan1

Epoxy laminated glass polyester layer protection fiber coalescence of oil mist and filtration of solid

particles

HF5(JLF5)GradeMainPipelineFilterElement

Filterelementinnerandouterlayerofcorrosionprotection

Multilayerglassfiberandmicrofiber,Largeparticlefilter,forthenextphaseoftheprefilteringcomposite

fiberlayerfurthercoalescencemicrooilmistlayertightlyattachedspongenet

Remove0.01ormoresolidandliquidparticles,remove99.99+%microoilmist,oilmistresidualcontent

is0.01ppm

1/3
Pleaseconsidertheenvironmentbeforeprintingthisdocument
Compressed air dryer operation instructions

3.Installationanddeployment

1.1 For the convenience of operation and replacement for maintenance, the filter should be installed
accordingtothepipelineindicatedinthechartontheright:
1.2Thedeploymentofthefiltercanrefertothepatternindicatedinthefollowingchart

2/3
Pleaseconsidertheenvironmentbeforeprintingthisdocument
Compressed air dryer operation instructions

4.Modelandmaintenance

3.1Thefiltersmadebyourcompanyaretheequipmentthattakesthecompressedairasthemedium.Itis
strictlyforbiddentorunothermediadirectlyintothefilter.Payspecialcarenottoexceedthespecified
maximumwork.Takespecialcarenottoexceedthespecifiedmaximumworkconditionatuse.
3.2Thefiltrationprecisionofthecompressedairfilterisdeterminedundercertaincondition.Theinletair
qualityhasobviousinfluenceovertheoperationeffectoftheprecisionfiltercores.Whennecessarythe
proper prep0sitive filter should be added to make the pretreatment of the inlet air quality. The filter
deploymentandinstallationshouldfollowtheJLF9JLF7JLF5JLF3JLF1sequence.Otherwisethe
filtrationeffectwillnotbereachedandthelifespanofthefiltercoreswillbereducedbybigmargin.
3.3Thefiltercoreistheprincipalpartofthefilter.Thepressuredropatthefilterinletandoutletshould
becheckedregularlyatwork.Whenpressuredropreacheshigherthan0.7Bar,thentheworklifespanof
the filter core is nearly at the end and the filter or the filter core must be replaced in time (The initial
pressuredropofasinglefiltercoreisabout(0.10.2)Bar.
3.4Should be resistant to chemical causticity. Generally the compressed air does not contain any
contaminantsharmfultofiltercores.However,somehydrocarbonspecies,acidspecies,alkalispeciesand
some special chemical substances may enter into the filter through compressor under the special
circumstances.
3.5Filter must raise or reduce pressure slowly at operation and dismantling of the filter should be
performedunderthepressurefreecondition.
3.6Replacementoffiltercores: Shouldtakecareduringdismantlingormountingthefiltercore.Should
notholdthefiltercorebarrelwithhandtoavoidthesurfacefiltermaterialofthefiltercorefrombeing
damaged.
3.7For the filters equipped with manual sewerage, should not open the sewerage under the pressure
situation (The filter mounted with automatic sewerage will automatically discharge the accumulated
waterinthefilterbarrel).
3.8Shouldnotselectfilterbythediameterofthefittingpipe,whiletheairtreatmentcapacityandthe
usagepressureshouldbetakenforselectingafilter.
3.9Bystrictlyfollowingtheaboveconditions,theuselifespanoftheHF9,HF7,HF5,andHf3typesoffilter
coresinthisseriescanreachover8000hoursandthatofHF1typeoffiltercoreswillbe2500hours(Itis
takentobetheworklifespanlimitwhentheworkpressuredropofasinglefiltercorereaches0.7Bar).


Theoperatingpressureis0.71.0MPa,belongtospecialoperatingpressure.
Alarm:
1 Pleasedontchangethedraintimethatwassetted.
2Pleaseattentiondraindirectionwheninstallorganofcatchwater,forfearthehighpressureairto
harmpeopleifdraining.
3Suggestuseof4000hourstoreplacethefilterelement.

3/3
Pleaseconsidertheenvironmentbeforeprintingthisdocument

HANGZHOUJIALONGAIREQUIPMENTCO.LTD
Address:NO.168,Wuxingvillage,QiaosiStreet,YuhangDistrict,
Hangzhou,China
Tel:057185365111
Fax:057185365000
Server:4001038600
Postcode:310001
EMail:13588827999@163.com
http://www.jialongequip.com.cn

Das könnte Ihnen auch gefallen