1 MM FLUSH MOUNT PRODUCT DIMENSIONS


CAVITY TEMPERATURE SENSOR BODY
SENSOR
TSFM01K

SENSOR HEAD

The 1 mm cavity temperature TSFM01K1


analyzes temperature variation inside the mold
cavity. The TSFM01K1 is designed for use
with RJG, Inc.s Lynx Quad Temperature Module
LSQTTBKwhich receives input from up to four
thermocouplesand the eDART.
CABLE LENGTH

TECHNICAL SPECIFICATIONS The TSFM01K1 sensor wire is available


in three lengths, and can be shortened or
The TSFM01K1 sensor head is made of lengthened appropriately for each application.
stainless steel, and can be contoured, angled, Length must be longer than needed to assure
and/or textured to match the cavity, The sensor s proper installation without tension on the lead
metalsheathed wire allows the sensor to work in wire.
mold temperatures of up to 752 F (400 C).
Part Number Length
Sensing Element Type K Thermocouple TSFM01K.5m 19.685 (0.5 m)
Sensor Temp 0707 F 0375 C TSFM01K1m 39.370 (1.0 m)
Accuracy 1.5C TSFM01K2m 78.740 (2.0 m)
Sensor Temp 707752 F 375400 C
Accuracy 0.4 % of reading
Sensor Max Temp 752 F 400 C
CABLE LENGTH
Cable Max Temp 428 F 220 C
RJG, INC. | www.rjginc.com | 231.947.3111
SENSOR INSTALLATION WIRING

RETAINING NUT INSTALLATION Negative (-) White


The sensor is retained in the mold inside a sleeve. Positive (+) Green
(Refer to figure below left.) The sensor tip length
is machinable, but a depth of 0.122 (3.1 mm) is
MACHINING
recommended. Use the provided installation tool
to thread the retaining nut firmly in place. Use the If the cavity must be surfaced or contoured, use
provided removal tool to remove the sensor if the following specifications to machine the sensor
required. head. The minimum tip dimension cannot be less
than 0.120 (3.05 mm). Failure to comply will
RETAINING SLEEVE INSTALLATION result in damage to the thermocouple junction.
The sensor is retained in the mold by a nut.
Dry Grind (per pass) 0.0127 mm 0.0005
(Refer to figure at below right.) The sleeve can
be trimmed from the sensor cable side onlydo Contour 0.3 mm 0.011811
not trim the sleeve from the sensor body side. Angle 5 0.45 mm 0.017716
Do no overcompress the sensor body. Use the
provided removal tool to remove the sensor if
required.

1 Cavity 1 A cable channel of 0.188 X 0.188 (4.775 mm X


4.775mm) can be milled through to the mold surface;
2 Sensor Pocket break all corners to avoid damage to cable. Use cable
putty to retain cable.
3 Cable Channel 1 2 If installed (retaining nut installation only).
4 Sensor 3 If installed (retaining sleeve installation only). Maximum
sleeve length is 3.937 (100 mm).
5 Retaining Nut 2,4 4 A minimum steel thickness of 0.433 (11 mm) is
6 Retaining Sleeve 3,4 required.

InstallationRetaining Nut InstallationRetaining Sleeve

Trim from this side only.

5
2 2 6
4 3 4 3

1 1

Tools
RJG, INC. | www.rjginc.com | 231.947.3111