GENERAL NOTES: THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL STANDARD DETAILS &

SPECIFICATIONS. ALL DIMENSIONS TO BE VERIFIED ON SITE. DO NOT SCALE FROM THIS DRAWING.
ALL WORKS TO COMPLY WITH CURRENT BUILDING REGULATIONS.

NOTES
HAZARD IDENTIFICATION LEGEND PSH
R 10 R9 R8 R7 R6 R5 R4 R3 R2 R1 HAZARD IDENTIFICATION CONTROL AND
(if none state 'none relevant') MITIGATION MEASURES

THIRD FLOOR IV IV IV IV IV IV IV
NONE RELEVANT
DRV DRV DRV DRV DRV DRV DRV
TYPICAL DOMESTIC
IV IV IV IV IV IV IV WATER SERVICES TO
BATHROOMS

NOTE:
Hazards listed above are only those considered
significant risks and:
(0.27 kg/s) a) not likely to be obvious to a competent contractor or
other designers:
(0.35 kg/s) b) unusual; or
SECOND FLOOR c) likely to be difficult to manage effectively
IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV
The above should be read in conjunction with additional
DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV information contained in the
Pre - Construction information documentation.
IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV
1. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT

SPECIFICATIONS.

2. ALL INFORMATION AND LAYOUT ON THIS DRAWING IS SUBJECT TO SITE


DIMENSION CHECKS. DO NOT SCALE FROM THIS DRAWING.
(0.27 kg/s) (0.45 kg/s)
3. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
(0.35 kg/s) FIRST FLOOR (0.47 kg/s) 4. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATION OR
IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV RELATED DOCUMENT, THE ENGINEER SHALL BE NOTIFIED IN WRITING
FOR VERIFICATION OF DISCREPANCY.
DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV
(0.5 kg/s) DESIGN/DEVELOPMENT.
IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV
(0.6 kg/s)

R1
(0.45 kg/s) (0.27 kg/s)

(0.47 kg/s) (0.35 kg/s) R2

GROUND R3
FLOOR
IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV
DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV DRV R4
PRV

PRV

PRV

PRV
IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV IV

R5
(0.5 kg/s) (0.33 kg/s)
BASEMENT

PRV

PRV

PRV

PRV

PRV
PRV

PRV
PRV

PRV

PRV

PRV

PRV
PRV

PRV

PRV
PRV

PRV
PRV

PRV
(0.6 kg/s) (0.43 kg/s)
R6
DRV

DRV

DRV

DRV
DRV

DRV

DRV

DRV

DRV
DRV
IV

IV

IV

IV

IV

IV

IV

IV
IV

IV

IV

IV

IV

IV

IV

IV

IV

IV
IV

IV
R7

IV PRV PRV IV
SERVICES CONTINUES TO SERVICES CONTINUES TO SERVE R8
SERVE ALL GUESTROOMS, DRV DRV THE CONFERENCE
SERVICES ANDTO
CONTINUE
MAIN KITCHENS,
SERVICES PUBLIC
CONTINUE SERVE WESTHALL,
BANQUETING WING TOILETS
KITCHENAND
AREASTO
AND BOHFINAL
SERVE AREAS IN
RISER IV PRV PRV IV KITHCENS. R9
MANOR SECTION OF THE
HOTEL.
(0.45 kg/s)

PRV

PRV
R10

(0.49 kg/s)
(4.80 kg/s) KEY PLAN

DRV
IV

IV
(0.57 kg/s)
C1 CONTRACT ISSUE 15.04.16 SF
(0.80 kg/s) PF
SERVICES TO BOH GG
WC'S, NEW SPA, AND
CHANGING AREAS
T1 ISSUED FOR TENDER 03.12.15 GHC
DP
CAC

REV. DESCRIPTION DATE DRN/CHK/APD

STR FC FC STATUS:

(6.56 kg/s) SV SV CONTRACT ISSUE


CLIENT:
DOMESTIC WATER PIPEWORK RUNS AT HL SPARE DHW SECONDARY
WITHIN BASEMENT CORRIDOR CIRCULATION PUMP
MOUNTED ON UNISTRUT
FRAME
LSV MANDEVILLE
1000 L
DHWS
1000 L
DHWS
HOTEL
IV CALORIFIER IV CALORIFIER
IV (NC)
25% 25%
IV MCW
MCW
AAV MCW AAV
DUTY DUTY
PRV DCV LSV PRV DCV LSV
IV DCV S IV DCV S PSH Consulting
LONDON:
DC
LS DC
LS ELECTRONIC WATER SV SV One Berkeley Street, Mayfair, London, W1J 8DJ. Tel: 0207 016 9580
S S CONDITIONER WITH BYPASS
INSULATED GRP WATER STORAGE SCREENED INSULATED GRP WATER STORAGE WOKINGHAM:
CISTERN WRAS: OVERFLOW AND CISTERN WRAS: LSV (NC) 6 Alexandra Court, Wokingham, Berkshire, RG40 2SL. Tel: 0118 977 4747
SCHEDULE 2, SECTION 7 WARNING SCHEDULE 2, SECTION 7
6 HOURS STORAGE PROPOSED 6 HOURS STORAGE PROPOSED Email: info@pshconsulting.co.uk
SCREENED IV IV
FULLY SELF DRAINING, FULLY SELF DRAINING,
OVERFLOW AND
(4.75 kg/s) Web: www.pshconsulting.co.uk
INTERNALLY FLANGED EXTERNALLY FLANGED
WARNING
3000LITRES IV (NO) IV (NO) 3000LITRES IV (NO)
500mm 500mm
ASSESSORS CIBSE
IV (NC) DC BMS
DC DC DC DC
PROJECT TITLE:
M EXISTING PRIMARY METER TO BE TO BMS THE CONTRACTOR IS RESPONSIBLE FOR CARRYING OUT
MAINTAINED AT BOUNDARY AND
SECONDARY METER INSTALLED IN
THE TANK ROOM WITH BMS
DC
IV (NC)
VALIDATIONS ON EXISTING DOMESTIC WATER SERVICES, TO
ENSURE ADEQUATE PIPE SIZING TO ALL AREAS. SECONDARY
PENDLEY MANOR HOTEL
PULSED OUTPUT.
IV (NO) PIPE SIZING TO ALL AREAS SHALL BE VALIDATED AND STRIPED
WHERE POSSIBLE AND THERMAL INSULATION TO BE INSTALLED
REFURBISHMENT
ON ALL NEW AND RETAINED PIPEWORK. VALIDATION RESULTS
IV FC TO BE ISSUED TO ENGINEER PRIOR TO STRIPPING OUT TO
DC P
ENSURE PIPE SIZING AND FLOW RATES ARE REFINED TO DRAWING TITLE:

EXISTING INCOMING SUPPLY TO


BE RETAINED AND MAIN SUPPLY
TANK SUPPORTED TO
ENSURE FULLY
VSD
TO LTHW
REFLECT ACTUAL DIMENSIONAL CAPACITY.
DOMESTIC WATER SERVICES
PIPEWORK REROUTED TO SERVE
STORAGE TANKS.
FLOODED PUMP
SUCTION
P
FC IV PRV
P
BTCW
IV
PRESSURISATION
UNIT REFER SCHEMATIC
IV IMPORTANT NOTE:
DC ALL NEW AND EXISTING (RETAINED) PIPEWORK TO BE
THERMALLY INSULATED.
SECONDARY PIPEWORK DISTRIBUTION ROUTES AND SIZES
TANK ROOM (MIDDLE BASEMENT SPACE) ARE INDICATIVE AND WILL BE VERIFIED ON SITE DURING HARCOURT PLANT ROOM DATE: SCALE: DRAWN: CHECKED: APPROVED:
CONSTRUCTION PERIOD PRIOR TO STRIP OUT.
MECHANICAL CONTRACTOR TO DEVELOP INSTILLATION NOV '15 NTS@A1 SF OD GG
DRAWINGS PRIOR TO STRIP OUT FOR APPROVAL BY
PROJECT No: DRAWING No: REVISION:
ENGINEER.
2719 MS-002 C1
PAPER SIZE = ISO:A1 (841x594mm)