Beruflich Dokumente
Kultur Dokumente
Value
mapping:
0: 0.0 dB
1: 0.5 dB
ExternalUtra timeToTrigge RNC Time long -1..15
nCell r1a between
detection of
event 1a
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
-1 means
that cell-
level
configuration
for this cell is
disabled.
Value
mapping:
-1:
UeMeasCon
trol::timeToT
rigger1a and
UeMeasCon
trol::reportin
gRange1a is
used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
RemoteUtra reportingRan RNC Threshold long 0..29
nCell ge1a used for
addition-
window in
evaluation
criteria for
event type
1a.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
When
setting
reportingRan
ge1a, the
following
dependency
must be
considered:
0 <=
reportingRan
ge1a +
reportingRan
ge1aOffsetS
econdary
<=29.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
RemoteUtra timeToTrigge RNC Time long -1..15
nCell r1a between
detection of
event 1a
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
-1 means
that cell-
level
configuration
for this cell is
disabled.
Value
mapping:
-1:
UeMeasCon
trol::timeToT
rigger1a and
UeMeasCon
trol::reportin
gRange1a is
used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
UeMeasCon hysteresis1a RNC Hysteresis long 0..15
trol used in
addition-
window in
evaluation
criteria for
event 1a to
avoid ping
pong effects.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0 : 0.0dB (no
hysteresis)
1 : 0.5dB
...
15 : 7.5dB
Unit: dB
UeMeasCon reportingInte RNC Interval of long 0..7
trol rval1a event-
triggered
periodical
reporting in
case of 'cell
addition
failure' or
'cell
replacement
failure'.
Indicates the
interval in
seconds of
periodical
reporting
triggered by
event 1a.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0 : No event-
triggered
periodical
reporting
1 : 0.25 s
2 : 0.5 s
3:1s
4:2s
UeMeasCon reportingRan RNC Used by UE long 0..29
trol ge1a functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
. Threshold
used for
addition-
window in
evaluation
criteria for
event type
1a.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
...
6: 3.0 dB
..
29: 14.5 dB
Unit: dB
UeMeasCon reportingRan RNC Used by UE long -20..20
trol ge1aOffsetS functions for
econdary intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
on
Secondary
UL
frequency.
System
constant for
the reporting
range for the
secondary
event 1a,
defining an
offset to be
added to the
reporting
range for the
(primary)
event 1a.
Reporting
range for
secondary
event 1a =
reportingRan
ge1a +
reportingRan
ge1aOffsetS
econdary
Value
mapping:
UeMeasCon timeToTrigge RNC Time long 0..15
trol r1a between
detection of
event 1a
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
4 : 60 ms
5 : 80 ms
6 : 100 ms
7 : 120 ms
8 : 160 ms
9 : 200 ms
10 : 240 ms
11 : 320 ms
12 : 640 ms
13 : 1280
ms
14 : 2560
ms
UeMeasCon w1a RNC 15 : 5000
Weight long 0..20
trol factor to
include
active set
cells other
than the
best in
evaluation
criteria for
event 1a.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
UtranCell reportingRan RNC Threshold long 0..29
ge1a used for
addition-
window in
evaluation
criteria for
event type
1a. Used by
UE functions
for intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
When
setting
reportingRan
ge1a, the
following
dependency
must be
considered:
0 <=
reportingRan
ge1a +
reportingRan
ge1aOffsetS
econdary
<=29.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
...
UtranCell timeToTrigge RNC Time long -1..15
r1a between
detection of
event 1a
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
-1 means
that cell-
level
configuration
for this cell is
disabled.
Value
mapping:
-1:
UeMeasCon
trol::timeToT
rigger1a and
UeMeasCon
trol::reportin
gRange1a is
used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
ExternalUtra reportingRan RNC Threshold long 0..29
nCell ge1b used for
drop window
in evaluation
criteria for
event 1b.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
...
6: 3.0 db
..
29: 14.5 dB
Unit: dB
ExternalUtra timeToTrigge RNC Time long -1..15
nCell r1b between
detection of
event 1b
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
-1 means
that cell-
level
configuration
for this cell is
disabled.
Value
mapping:
-1:
UeMeasCon
trol::timeToT
rigger1b and
UeMeasCon
trol::reportin
gRange1b is
used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
RemoteUtra reportingRan RNC Threshold long 0..29
nCell ge1b used for
drop window
in evaluation
criteria for
event 1b.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
...
6: 3.0 db
..
29: 14.5 dB
Unit: dB
RemoteUtra timeToTrigge RNC Time long -1..15
nCell r1b between
detection of
event 1b
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
-1 means
that cell-
level
configuration
for this cell is
disabled.
Value
mapping:
-1:
UeMeasCon
trol::timeToT
rigger1b and
UeMeasCon
trol::reportin
gRange1b is
used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
UeMeasCon hysteresis1b RNC Hysteresis long 0..15
trol used in the
drop window
in evaluation
criteria for
event type
1b. Used by
UE functions
for intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0 : 0.0 dB
(no
hysteresis)
1 : 0.5 dB
...
15 : 7.5 dB
Unit: dB
UeMeasCon reportingRan RNC Used by UE long 0..29
trol ge1b functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
. Threshold
used for
drop window
in evaluation
criteria for
event 1b.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
...
10: 5.0 dB
..
29: 14.5 dB
Unit: dB
UeMeasCon timeToTrigge RNC Time long 0..15
trol r1b between
detection of
event 1b
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
4 : 60 ms
5 : 80 ms
6 : 100 ms
7 : 120 ms
8 : 160 ms
9 : 200 ms
10 : 240 ms
11 : 320 ms
12 : 640 ms
13 : 1280
ms
14 : 2560
ms
UeMeasCon w1b RNC 15 : 5000
Weight long 0..20
trol factor to
include
active set
cells other
than the
best in
evaluation
criteria for
event 1b.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
UtranCell reportingRan RNC Threshold long 0..29
ge1b used for
drop window
in evaluation
criteria for
event 1b.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
.
Value
mapping:
0: 0.0 dB
1: 0.5 dB
...
6: 3.0 db
..
29: 14.5 dB
Unit: dB
UtranCell timeToTrigge RNC Time long -1..15
r1b between
detection of
event 1b
and sending
of the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
-1 means
that cell-
level
configuration
for this cell is
disabled.
Value
mapping:
-1:
UeMeasCon
trol::timeToT
rigger1b and
UeMeasCon
trol::reportin
gRange1b is
used
0 : 0 ms
1 : 10 ms
2 : 20 ms
3 : 40 ms
UeMeasCon hysteresis1c RNC Used by UE long 0..15
trol functions for
intra-
frequency
measureme
nt reporting
(in
CELL_DCH)
. Hysteresis
used in
replacement
threshold in
evaluation
criteria for
event 1c to
avoid ping
pong effects.
Value
mapping:
0: 0.0 dB
(no
hysteresis)
1: 0.5 dB
2: 1.0 dB
..
15: 7.5 dB
Unit: dB
UeMeasCon reportingInte RNC Interval of long 0..7
trol rval1c event-
triggered
periodical
reporting in
case of 'cell
addition
failure' or
'cell
replacement
failure'.
Indicates the
interval in
seconds of
periodical
reporting
triggered by
event 1c.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0: No event-
triggered
periodical
reporting
1: 0.25 s
2: 0.5 s
3: 1 s
4: 2 s
UeMeasCon timeToTrigge RNC Time long 0..15
trol r1c between
detection of
event 1c and
sending of
the
measureme
nt report.
Used by UE
functions for
intra-
frequency
measureme
nt reporting
in
CELL_DCH.
Value
mapping:
0: 0 ms
1: 10 ms
2: 20 ms
3: 40 ms
4: 60 ms
5: 80 ms
6: 100 ms
7: 120 ms
8: 160 ms
9: 200 ms
10: 240 ms
11: 320 ms
12: 640 ms
13: 1280 ms
14: 2560 ms
15: 5000 ms
The value 0
means
infinity.
Unit: dB
Resolution:
3
Unit: dB
UtranRelatio hcsSib11Co RNC Specifies the long 0..0 2..2 3..3
n nfig.tempora value of the 4..4 6..6 8..8
ryOffset2 Information 10..10
Element 12..12
Temporary_
offset2 for a
neighbouring
cell in
System
information
Block 11.
For the
description
of this
Information
Element,
see 3GPP
TS 25.331.
The value 0
means
infinity.
Unit: dB
Resolution:
N/A
Unit: dB
UeMeasCon event1dRnc RNC Offset added long -25..25
trol Offset to the cell
measureme
nts received
in event 1a
and/or event
1c
measureme
nt reports,
when
determining
whether to
trigger event
1d-RNC.
Received 1a
/ 1c event
reports
proposing to
add a cell to
the active
set, where
the
proposed
cell does not
have the
capabilities
required to
provide the
same level
of service as
the existing
cells in the
active set,
are only
considered if
adding this
offset to the
UeMeasCon event1dRnc RNC Number of long 0..60
trol Threshold consecutive
times that
event 1a
and/or event
1c
measureme
nt reports
must be
received
proposing to
add a
particular
cell to the
active set,
where the
proposed
cell does not
have the
capabilities
required to
provide the
same level
of service as
the existing
cells in the
active set.
Once the
threshold is
reached,
event 1d-
RNC will be
triggered.
This will
cause a
reconfigurati
UeMeasCon hsHysteresis RNC on based on long
Hysteresis 0..75
trol 1d value for
event 1D for
HS
connections.
Unit: dB
UeMeasCon hsTimeToTri RNC Sets the long 0..0 10..10
trol gger1d Event 1D 20..20
Time to 40..40
Trigger value 60..60
specific for 80..80
HS 100..100
connections 120..120
Unit: ms 160..160
200..200
240..240
320..320
640..640
1280..1280
2560..2560
5000..5000
Value
mapping:
0: 0.0 dB
(no
hysteresis)
1: 0.5 dB
2: 1.0 dB
...
15: 7.5 dB
Unit: dB
UeMeasCon timeToTrigge RNC Time long 0..15
trol r1d between
detection of
event 1d
and sending
of the
measureme
nt report.
Value
mapping:
0: 0 ms
1: 10 ms
2: 20 ms
3: 40 ms
4: 60 ms
5: 80 ms
6: 100 ms
7: 120 ms
8: 160 ms
9: 200 ms
10: 240 ms
11: 320 ms
12: 640 ms
13: 1280 ms
14: 2560 ms
15: 5000 ms
Default ValueRecommended
CPI ReferencAccess Mandatory Persistent Notification Sequence
0 Read/Write N Y Y N
-1 Read/Write N Y Y N
0 Read/Write N Y Y N
-1 Read/Write N Y Y N
0 0 76/1553- Read/Write N Y Y N
HSD 101
02/10
3 3 76/1553- Read/Write N Y Y N
HSD 101
02/10
6 6 76/1553- Read/Write N Y Y N
HSD 101
02/10
-2 Read/Write N Y Y N
11 11 76/1553- Read/Write N Y Y N
HSD 101
02/10
0 0 76/1553- Read/Write N Y Y N
HSD 101
02/10
0 6 76/1553- Read/Write N Y Y N
HSD 10102
-1 -1 76/1553- Read/Write N Y Y N
HSD 10102
0 Read/Write N Y Y N
-1 -1 76/1553- Read/Write N Y Y N
HSD 101 02
0 Read/Write N Y Y N
-1 -1 Read/Write N Y Y N
0 0 76/1553- Read/Write N Y Y N
HSD 101
02/10
10 10 76/1553- Read/Write N Y Y N
HSD 101
02/10
12 12 76/1553- Read/Write N Y Y N
HSD 101 02
0 0 76/1553- Read/Write N Y Y N
HSD 101
02/10
0 10 76/1553- Read/Write N Y Y N
HSD 10102
-1 -1 76/1553- Read/Write N Y Y N
HSD 10102
2 2 76/1553- Read/Write N Y Y N
HSD 101
02/10
3 3 76/1553- Read/Write N Y Y N
HSD 101
02/10
11 11 76/1553- Read/Write N Y Y N
HSD 101
02/10
71/1553- Read/Write N Y Y N
HSD 101
02/7
0 0 71/1553- Read/Write N Y Y N
HSD 101
02/7
0 0 71/1553- Read/Write N Y Y N
HSD 101
02/7
0 0 71/1553- Read/Write N Y Y N
HSD 101
02/7
0 0 71/1553- Read/Write N Y Y N
HSD 101
02/7
0 0 71/1553- Read/Write N Y Y N
HSD 101
02/7
0 2 76/1553- Read/Write N Y Y N
HSD 101
02/10
4 2 76/1553- Read/Write N Y Y N
HSD 101
02/10
10 10 76/1553- Read/Write N Y Y N
HSD 101
02/10
640 640 76/1553- Read/Write N Y Y N
HSD 101
02/10
15 15 76/1553- Read/Write N Y Y N
HSD 101
02/10
14 14 76/1553- Read/Write N Y Y N
HSD 101
02/10
Change Take Network EntitFeature Nam Feature NumbBulkCM MO CBulkCM Para Initial Tuning RN Optimization
Ongoing vsDataExter reportingRan
connections nalUtranCell ge1a
(next
reconfigurati
on where a
Measureme
nt Control
message for
Soft/Softer
Handover
purpose is
sent)
Ongoing vsDataExter timeToTrigge
connections nalUtranCell r1a
(next
reconfigurati
on where a
Measureme
nt Control
message for
Soft/Softer
Handover
purpose is
sent)
Ongoing RNC in Pool FAJ 121
connections 2096
(next
reconfigurati
on where a
Measureme
nt Control
message for
Soft/Softer
Handover
purpose is
sent)
Ongoing RNC in Pool FAJ 121
connections 2096
(next
reconfigurati
on where a
Measureme
nt Control
message for
Soft/Softer
Handover
purpose is
sent)
Ongoing RNC Soft/Softer FAJ 121 127 vsDataUeMe hysteresis1a N Intermediate
connections Handover R2 asControl
(next switch and Cell Re-
to selection
CELL_DCH) [basic]
Ongoing RNC Soft/Softer FAJ 121 127 vsDataUeMe reportingInte N Intermediate
connections Handover R2 asControl rval1a
(next switch and Cell Re-
to selection
CELL_DCH) [basic]
Ongoing RNC Soft/Softer FAJ 121 127 vsDataUeMe reportingRan N Basic
connections Handover R2 asControl ge1a
(next switch and Cell Re-
to selection
CELL_DCH) [basic]
Ongoing EUL Multi- FAJ 121
connections Carrier 1491
(next switch
to
CELL_DCH)
Ongoing RNC Soft/Softer FAJ 121 127 vsDataUeMe timeToTrigge N Advanced
connections Handover R2 asControl r1a
(next switch and Cell Re-
to selection
CELL_DCH) [basic]