ITS-90 FIXED-POINT CELLS

Once manufactured, all Hart cells are


tested and supplied with an assay of

Primary Standards
metal-sample purity. Every traditional size
ITS-90 cell further undergoes more rigor-
ous testing in our primary standards lab
where we realize melt-freeze curves and
perform a detailed slope analysis to con-
firm cell purity. If you want more data,
well give you an optional intercomparison
with our own reference cells.

Gallium Cells
Gallium cells are a great reference for
validation of instruments subject to drift
(like SPRTs) and theyre important for cal-
ibrating sensors used near room or body
temperatures, in environmental monitor-
ing, and in life sciences applications.
Hart makes two traditional-size gallium
cells. The Model 5943 Gallium Cell is
sealed in a stainless steel envelope. High
purity gallium (99.99999%) is enclosed in
a plastic and metal shell. The stainless steel
container is then filled with pure argon gas
ITS-90 Fixed-Point Cells at one standard atmosphere at the melt-
Best cell uncertainties commercially available ing-point temperature.
Gallium expands on freezing by 3.1%,
Every ITS-90 fixed point available from mercury to copper
requiring the cell to have flexible walls.
Plateaus last days (gallium for weeks and TPW for months) Unlike some manufacturers cells, which
Manufactured and tested by Harts primary standards scientists are made from PTFE enclosure materials,

H art scientists have designed and tested


ITS-90 fixed-point cells for many
years. Not only do we manufacture all the
Harts metal freeze-point cells are the
culmination of more than 20 years of pri-
mary standards experience. No other com-
major fixed points, our metrologists have pany has as much experience in the devel-
written extensively on the theory and use of opment of metal fixed-point cells as Hart.
cells and have created new designs cover- Thats why youll find Hart cells in many
ing a range of applications no other com- national metrology institutes around the
pany can match. world.
Our testing of fixed-point cells is also Each Hart cell is carefully constructed
unmatched. The scope of our accreditation in our ultra-clean, state-of-the-art lab, us-
includes the testing of ITS-90 fixed-point ing high-density, high-purity graphite cru-
cells. Each cell may be purchased with this cibles containing metal samples with pu-
intercomparison option, which includes rity of at least 99.9999% (six 9s) and in
comparing the equilibrium value of your many cases 99.99999% (seven 9s). The
cell against that of a reference Hart cell. crucible is enclosed within a sealed quartz
glass envelope that is evacuated and
Traditional Freeze-Point Cells back-filled with high-purity argon gas. A
If you want true primary temperature special sealing technique is used to seal the
standards capability, you want metal cell at the freezing point. We measure and
freeze-point cells that are very close to the record for you the precise pressure of the In addition to our stainless steel-encased gallium cell, the Model
theoretical freezing temperature and provide argon gas to ensure the most accurate cor- 5903 Gallium Cell, enclosed in traditional Pyrex glass, offers pla-
plateaus that are both stable and long lasting. rections for pressure. teaus that can last for weeks when maintained in a Hart metrology
bath.

www.hartscientific.com 21
ITS-90 FIXED-POINT CELLS

Specifications
Primary Standards

Assigned Outside Inside Total Outside Cell Uncertainty Certification


Model Fixed Point Style Value (C) Diameter Diameter Cell Height Depth (mK, k=2) (mK, k=2)
5900 Mercury Stainless Steel 38.8344 31 mm 8.2 mm 470 mm 200 mm 0.2 0.25
5903 Gallium Traditional Quartz Glass 29.7646 42 mm 8 mm 300 mm 150 mm 0.08 0.1
5904 Indium Traditional Quartz Glass 156.5985 48 mm 8 mm 285 mm 195 mm 0.7 0.7
5905 Tin Traditional Quartz Glass 231.928 48 mm 8 mm 285 mm 195 mm 0.5 0.8
5906 Zinc Traditional Quartz Glass 419.527 48 mm 8 mm 285 mm 195 mm 0.9 1.0
5907 Aluminum Traditional Quartz Glass 660.323 48 mm 8 mm 285 mm 195 mm 1.3 1.8
5908 Silver Traditional Quartz Glass 961.78 48 mm 8 mm 285 mm 195 mm 2.4 4.5
5909 Copper Traditional Quartz Glass 1084.62 48 mm 8 mm 285 mm 195 mm 10.1 12.0
5910 Gold Traditional Quartz Glass 1064.18 48 mm 8 mm 285 mm 195 mm 2.5 4.5
5924 Indium Open Quartz Glass 156.5985 50 mm 8 mm 596 mm 195 mm 0.7 0.7
5925 Tin Open Quartz Glass 231.928 50 mm 8 mm 596 mm 195 mm 0.5 0.8
5926 Zinc Open Quartz Glass 419.527 50 mm 8 mm 596 mm 195 mm 0.9 1.0
5927A-L Aluminum Open Quartz Glass (long) 660.323 50 mm 8 mm 696 mm 195 mm 1.3 1.8
5927A-S Aluminum Open Quartz Glass (short) 660.323 50 mm 8 mm 596 mm 195 mm 1.3 1.8
5928 Silver Open Quartz Glass 961.78 50 mm 8 mm 696 mm 195 mm 2.4 4.5
5929 Copper Open Quartz Glass 1084.62 50 mm 8 mm 696 mm 195 mm 10 12.0
5943 Gallium Stainless Steel 29.7646 38.1 mm 8.2 mm 250 mm 168 mm 0.1 0.1

Certifications at lower uncertainties are available for national laboratories.

Depth is measured from the bottom of the thermometer well to the top of the pure reference material.

our cells dont need pumping and refilling ature on the ITS-90, and theyre
because theyre not gas permeable. In fact, inexpensive to own and use.
we guarantee our cells will maintain their Hart makes three traditional size TPW
uncertainty of < 0.1 mK for at least five cells (see page 18) that have been repeat-
years. Realization and maintenance of the edly proven in national labs to surpass their
cell is automated with our Model 9230 published uncertainty specification of
Maintenance Apparatus (see page 32). This 0.0001C. Ice mantles may be formed us-
apparatus will provide melting plateaus up ing dry ice, LN2, or immersion freezers and
to eight days and a convenient control to can last for up to two months when main-
automatically achieve a new melt plateau tained in our 7012 or 7312 baths.
each week with an investment of just five
minutes. Never has the maintenance of a Open Metal Cells
world-class gallium cell been easier. Made from the same materials and with
Harts 5903 is sealed in a borosilicate the same manufacturing techniques as their
glass envelope, uses similar manufacturing sealed counterparts, Harts new series of
techniques, and provides similar low un- open metal fixed-point cells include a
certainties; and when maintained in a Hart high quality valve for connecting to a pre-
Model 7012 or 7312 maintenance bath, cision pressure-handling system within
your melting plateaus will last as long as 14 your lab. Using such a system, the cell can
daysthats days, not hours. be evacuated, charged and purged several
times with a pure inert gas, then charged
Water Cells again to a regulated pressure level while
While simple ice baths are often used as measurements are made with the cell.
a calibration point at 0C, their limitations Once assembled and tested, each Hart
include gradients, purity problems, repeat- ITS-90 open cell further undergoes more
ability issues, and variances in construction rigorous testing in our lab, unlike cells Open cells allow users to minimize the uncertainty from pressure
and measurement techniques. Triple point from some manufacturers who provide corrections by regulating cell pressures themselves.
of water cells not only solve these prob- their open cells as a kit of parts, without any
lems, they represent the most used temper- test data.

22 (800) 438-4278
ITS-90 FIXED-POINT CELLS
Because open cells allow users to mea- Direct Comparison of Hart Scientific Ga Cell (s/n Ga-7010)
sure the pressure within the cell, uncertain- with NIST Reference Ga Cell (Ga 98-1)

Primary Standards
ties due to pressure corrections may be 1.118 101 5
minimized. Use of open cells is now being
suggested by the CCT, and open cells can
be used for demanding temperature-ver- 1.118 101 3

sus-pressure applications as well as preci-


NIST Ga 98-1,
sion SPRT calibrations. set #1
1.118 101 1 0.10 mK
The height of these cells has been ex- Hart Ga-7010,

W(Ga)
set #1, -0.07 mK
tended to allow easy access to the gas valve NIST Ga 98-1,
set #2
while the cells are in use. Pure quartz-wool 1.118 100 9
Hart Ga-7010,
insulation and four high-purity graphite set #2, -0.05 mK

discs prevent heat loss from the metal sam-


1.118 100 7
ple to the pressure regulation system while
optimizing vertical temperature gradients
within the cell. Each cell has an outside di- 1.118 100 5
ameter of 50 mm and a height of 600 mm 0 1 2 3 4 5 6 7
number of readings
(silver and copper cells are 700 mm tall).
When it comes to primary temperature
standards, Hart supplies more equipment Direct Comparison of Hart Scientific Sn Cell (s/n Sn-8014)
than all of our competitors put together. If with NIST Reference Sn Cell (Sn 88A)
1.892 591 2
your goal is to reduce uncertainty, start by
buying from the company that supports its
1.892 591 0
products better than any other metrology
company in the world. Why trust your pri-
1.892 590 8
mary standards to any other company? NIST Sn 88A,
set #1
1.892 590 6 Hart Sn 8014,
W(Sn)

0.27 mK set #1, -0.25 mK


NIST Sn 88A,
1.892 590 4 set #2
Hart Sn 8014,
set #2, -0.24 mK
1.892 590 2
Technical Tip
1.892 590 0
What Is the Uncertainty of My Cell?
Fixed-point cells are artifact standards, which 1.892 589 8
embody reproducible physical phenomena. The un- 0 1 2 3 4 5 6 7

certainty associated with these artifacts can be number of readings

viewed in two ways.


The first way is the theoretical uncertainty based
on the purity of the constituent components only. Un-
Ordering Information
certainty computed in this manner can be considered 5900 Mercury Cell, Stainless Steel 5925 Tin Cell, Open Quartz Glass
an ideal view. Because these purity figures are often 5903 Gallium Cell, Traditional Pyrex Glass 5926 Zinc Cell, Open Quartz Glass
not based on traceable measurements, their value in
5904 Indium Cell, Traditional Quartz Glass 5927A-S Aluminum Cell, Open Quartz Glass, Short
the calibration laboratory is questionable.
5905 Tin Cell, Traditional Quartz Glass 5927A-L Aluminum Cell, Open Quartz Glass, Long
The second way is the tested or guaranteed un-
certainty, which represents observed performance 5906 Zinc Cell, Traditional Quartz Glass 5928 Silver Cell, Open Quartz Glass
under real (not ideal) conditions. These figures repre- 5907 Aluminum Cell, Traditional Quartz Glass 5929 Copper Cell, Open Quartz Glass
sent what has actually been observed in the labora- 5908 Silver Cell, Traditional Quartz Glass 5943 Gallium Cell, Stainless Steel
tory and what can be expected in use. Although the 5909 Copper Cell, Traditional Quartz Glass 1904-X Accredited Cell Intercomparison
theoretical uncertainty may be useful, the actual un-
5910 Gold Cell, Traditional Quartz Glass 2931-LG Protective Wood Case, traditional cells
certainty is what influences our measurements.
Harts published specs are guaranteed and can 5924 Indium Cell, Open Quartz Glass
Read about our calibration training
be verified through an optional accredited certifica- courses on page 153.
tion in our primary temperature lab.